JOB NO.
Southern Region Houston, Texas BY DATE:
CHKD. DATE:
PAGE REV.
CLIENT AND LOCATION Atofina, Beaumont, Texas
UNIT Sulfox
ITEM Trunnion loads on base ell at node 425. Ceasar calculation 25-007
8" Sch 40s elbow with type 7 trunnion.
TRUNNION OR OTHER CYLINDRICAL ATTACHMENTS TO PIPE
SUSTAINED INPUT
Header Pipe: Reinforcing Pad:
Outside Diameter D (in.) 8.625 Reinforcing Pad thickness (in.) 0
Wall Thickness (in.) 0.322 Note 3
Corrosion Allowance (in.) 0 Note 4 Wall Thickness + Pad Thk - Corrosion t (in.) 0.322
Trunnion:
Outside Diameter d (in.) 6.625 Notes:
Wall Thickness (in.) 0.28 1. All stress values below are given in lbs/in2.
Length of Trunnion L (in.) 22.4 Note 5 2. All load values below are given in lbs.
Weld Size (in) 0.148 3. If line is existing, check against actual wall thickness
as reported by plant inspection.
Applied Loads (lbs) and Moments (in-lbs): 4. If line is existing, use corrosion allowance as reported by
plant inspection, or use original corrosion allowance as
Longitudinal Moment ML (in - lbs) 0 reported in original pipe specification, whichever is greater.
Circumfrential Moment Mc (in - lbs) 0 5. Length of trunnion determined from outside wall of run pipe to
Axial Force on Trunnion W (lbs) 2525 to contact with grade or centerline of support beam.
Design Pressure P (psi) 64
Design Temperature (F) 200
Allowable Stresses:
Hot Allowable Stress (psi) 16700
Cold Allowable Stress (psi) 16700
EQUATIONS
Longitudinal Circumfrential Axial
ML Mc W
f L= 2 f c= f a=
2
( /4)d ( /4 )d 2 (d /2)
1.17f ( D/2) P( D/2 ) 1 . 17 f ( D /2) P( D /2 ) 1 .17 f ( D /2 ) P( D/2)
S L= + Sc= + S A= +
t1 .5 2t t 1 .5 t
t 1. 5 t
Rev.6
SUSTAINED CALCULATIONS
NOTE: IF ANY FAILURES RESULT BELOW, THE PIPING LOADS MUST BE ADJUSTED AND THEN RE-CALCULATED
Longitudinal Evalvuation
Note: Expansion Load case gives the same result as Sustained Case. No evaluation is necessary.
Circumferential Evaluation
fcs = 0
Sustained Load Case (Mc)
Localized Load f2 = 1.5(fcs) f2s = 0 Sc2s = 857 < 1.5 Sh = 25,050 PASS
Localized Load f2 =1.5( fc + fa) f2Ma = 182 Sc2Ma = 3,277 < 1.5 Sh = 25,050 PASS
f r = f 2L + f 2C fr = 0
Axial Evaluation
f s L
f s = f 2L +f 2c fs = 0 S b= Sb = 0 < Sh = 16,700 PASS
Zt
Trunnion Section Modulus
Weld Resulant Force
D 4 d 4
Z t=
32 ( D ) Zt = 8.5
f F= f 2L+f 2c +f 2a
fF = 121
Rev.6
CALCULATIONS AND SKETCHES
JOB NO. 0
Southern Region Houston, Texas BY 0 DATE: ###
CHKD. DATE:
PAGE REV.
CLIENT AND LOCATION Atofina, Beaumont, Texas
UNIT Sulfox
ITEM Trunnion loads on base ell at node 425. Ceasar calculation 25-007
8" Sch 40s elbow with type 7 trunnion.
TRUNNION OR OTHER CYLINDRICAL ATTACHMENTS TO PIPE
EXPANSION INPUT
Header Pipe: Reinforcing Pad:
Outside Diameter D (in.) 8.625 Reinforcing Pad thickness (in.) 0
Wall Thickness (in.) 0.322 Note 3
Wall Thickness + Pad Thk t (in.) 0.322
Trunnion:
Outside Diameter d (in.) 6.625 Notes:
Wall Thickness (in.) 0.28 1. All stress values below are given in lbs/in2.
Length of Trunnion L (in.) 22.4 Note 5 2. All load values below are given in lbs.
Weld Size (in) 0.148 3. If line is existing, check against actual wall thickness
as reported by plant inspection.
Applied Loads (lbs) and Moments (in-lbs): 4. If line is existing, use corrosion allowance as reported by
plant inspection, or use original corrosion allowance as
Longitudinal Moment ML (in - lbs) 16970 reported in original pipe specification, whichever is greater.
Circumfrential Moment Mc (in - lbs) 16970 5. Length of trunnion determined from outside wall of run pipe to
Axial Force on Trunnion W (lbs) 340 to contact with grade or centerline of support beam.
Design Pressure P (psi) 64
Design Temperature (F) 200
Allowable Stresses:
Hot Allowable Stress (psi) 16700
Cold Allowable Stress (psi) 16700
EQUATIONS
Longitudinal Circumfrential Axial
ML Mc W
f L= 2 f c= 2
f a=
( /4)d ( /4 )d 2 (d /2)
1.17 f ( D/2) P( D/2) 1 . 17 f ( D/ 2) P( D/ 2 ) 1 .17 f ( D /2 ) P( D/2)
S L= + Sc= + S A= +
t1 .5 2t t 1 .5 t t 1.5 t
Rev.6
EXPANSION CALCULATIONS
NOTE: IF ANY FAILURES RESULT BELOW, THE PIPING LOADS MUST BE ADJUSTED AND THEN RE-CALCULATED
Longitudinal Evalvuation
Note: Expansion Load case gives the same result as Sustained Case.
Circumferential Evaluation
Expansion Load Case (Mc) fcE = 492
Localized Load fcE = fc
ScE = 7,403 < 1.5 Sh = 25,050 PASS
f r = f 2L + f 2C fr = 696
Axial Evaluation
fa = 16
f s L
f s = f 2L +f 2c fs = 696 Sb= Sb = 1,836 < Sh = 16,700 PASS
Zt
Trunnion Section Modulus
Weld Resulant Force
4 4
Zt=
32 D(
D d
) Zt = 8.5
f F= f 2L+f 2c +f 2a
fF = 696