Professional Documents
Culture Documents
Software
GRAVIMAX Series 18
Software version for PP220: 3.21.70
Software version for PP420: 3.22.70
This training manual is copyrighted material. All rights reserved, including those for translation, reprinting,
presentation, removal of figures and tables, transmission via radio or television, microfilming, or other means
of duplication, as well as storage in data processing systems, or any other use in whole or in part of this
document.
Wittmann Kunststoffgerte GmbH reserves the right to make changes to any part of this training manual with
prior notice.
This training manual was carefully prepared; however Wittmann GmbH assumes no liability for any errors or
any direct or indirect harm resulting from use of this training manual.
Recipe management
Configuration Menu
View
Components 1 - 4
Components 5 - 8
The main window shows the general operation of
the blender. All functions are performed by touch-
ing the display.
The main menu shows a list of all components
(including those who are not used). To switch the
Date/Time view between the components 1-4 and 5-8, press
Recipe name User the button Components 1 - 4 or Components 5 -
8. Following parameters are displayed for each
component:
Play
Pause
Stop
Icon Remarks
Hopper Starting with 1 depend-
number ing on the machine up
to index number 8
Color code:
yellow = VIRGIN
orange = REGRIND
4. Use the numbers for the input, and the 2.2.1 Information
symbols for:
The display will show a page of information.
Confirm input
Delete input
Leave input
Press .
Date/Time
Substance bulky of the last
components name material autotuning
Regrind-mode Number of
active batches
Note for the creation of new recipes that calcula- With the automatic recipe changeover a change
tion formula, see 3.2 Calculation formula. between several recipes can be performed.
From an external device (eg. injection molding
machine) the desired recipe is selected. Driven by
Second recipe electrical inputs the GRAVIMAX control selects the
The second recipe function is used to allow for desired recipe.
continuous production with regrind material. A level
sensor in the regrind material hopper, located in
the clip-on corner window will monitor the level of The activation from the automatic recipe
regrind in the material hopper. If there is enough changeover can only be performed by a
regrind material, a "High Recipe" will be activated service technician from Wittmann.
which will dispense a higher Regrind percentage. If In order to use the automatic recipe changeover, a
there is not enough regrind material available, the user Tester must activate the check box Rec-
4. Confirm with .
Edit material:
1. Press .
2. Edit parameters.
If the automatic recipe changeover is activated,
second recipe (High Recipe, Low Recipe) 3. Put the weight back with .
cannot be used!
1. Press or to
load recipe from the blender in the graph-
ical user interface.
2.6.2 Interfaces
In the interface menu all the settings for connec-
tions and locations are determined.
To switch between the sub-menus, use or .
In this menu you will find all information about the File Destination:
FTP connection. It is possible to change the pass- Enter the path in which the batch history has to be
word, IP address and port. saved.
2.6.3 Mixer
In this menu all settings for the mixing process can
be set.
Timing:
Mixer Timing can be selected between four set-
tings:
Continous Mixing:
The mixing process is carried out continuously,
regardless of whether material is present or not.
Past Mixing:
With file upload, you can save four different files After the regular mixing, a second mixing process
(batch history, alarm history, parameter file, recipe of the granulate in the ball mixer is carried out.
file) in the given bath.
Stop Sensor Mixing:
This item can only be selected by the user groups
2.6.2.7 A. Bradley Communication Tester and Service.
In this menu you can activate a communication to There is no mixing process started, although the
a Alan Bradley control. This allows data to be sensor detects material in the mixing bin.
written and read simultaneously. Pneumatic Mixer:
Defined a pneumatically driven mixing motor.
Enable to this option, an additional option Pulse
Time is displayed. In the Pulse Time the time is
adjusted, which lies between the mixing passages.
2.6.4 Component
Please refer to 2.5 Recipe Management and the
following subsections.
2.6.5 Parameter
In the parameter menu, you can choose between
the various components and thus define the pa-
rameters for each component specifically.
4. Press .
5. Remove the calibration weight.
The calibration is now completed.
2. Confirm with .
2. Press .
Depending on the selected model, the number of
settings and the main window on the display will
change.
Number of Users
Define the number of users.
Auto Logout Time
If no more entries made, the user should be logged
out after this time.
For the user Service, the time is irrelevant, he will
never be logged out.
Extern Demand Sensor
To maintain an external level of material under the
blender.
3. Change the desired parameters.
Other Settings
Here you can define the language and the weight
unit.
5. Confirm the changes with .
or