Serviceability Girder Stresses: General Case

Harbour Link - New Harbour Bridge 3 lane option

Span = 40 D= 2.70 m
Midspan Stresses Gross Properties
Effective Section
A 11.5000 m^2 Ag 12.8500 m^2
I 11.300 m^4 Ig 12.800 m^4
Y girder 1.046 m top Ytop 1.019 m top
Y girder 1.654 m bot Ybot 1.681 m bot

Prestressing Force for one Strand 108 kN 0.59 fpu


No of strands / tendon 19
Force in tendon 2052 kN
Stressing
No of tendons in top flange 23
distance tendond centroid from bot of girder 2.49 m
No of tendons in bot flange 14
distance to girder centroid from bot of girder 0.31714286 m
Distance to stressing centroid from bot of girder 1.668 m
Distance to stressing centroid from N/A (e) -0.013 m (postive measured towards top flange)

Total Prestressing Force 75924 kN

Midspan Stress
Stress Stress
Combination Girder Girder
Bottom Top
MPa MPa

Combination 1A 0
Flexure DL+LLxI 35035 -5.13 3.24
use effective section properties
Shortening Tension -0.04 -0.04 -0.04
Shortening Bending -0.08 0.15
SUB TOTAL -5.24 3.35

Prestressing P/A 5.91 5.91


use gross section properties Pe/Z -1022 0.13 -0.08

Differential Temp 0.00 0.00

SUB TOTAL 6.04 5.83

TOTAL 0.80 9.18


ALLOWABLE STRESS : Tension=0MPa, Compression=27.0 MPa (fci=45)

382911262.xls Page 1 08:54:44 03/30/2018


Negative Moment
Effective Span = 40 D= 2.70 m
Gross Properties Pier Stresses
Effective Section
Ag 12.8500 m^2 A 9.4000 m^2
Ig 12.800 m^4 I 9.000 m^4
Ytop 1.019 m top Y girder 1.096 m top girder
Ybot 1.681 m bot Y girder 1.604 m bot

Prestressing Force for one Strand 108 kN 0.59 fpu


No of strands / tendon 19
Force in tendon 2052 kN
Stressing
No of tendons in top flange 31
distance tendond centroid from bot of girder 2.39 m
No of tendons in bot flange 10
distance to girder centroid from bot of girder 0.21 m
Distance to stressing centroid from bot of girder 1.86073171 m
Distance to stressing centroid from N/A (e) 0.179 m (postive measured towards top flange)

Total Prestressing Force 84132 kN

Stresses Over Pier


Critical Stress Stress
Class Combination Moment Girder Girder
Bottom Top
KNm MPa MPa

Combination 1A
DL+LLxI -59586 10.62 -7.26

Shortening Tension -0.04 -0.04 -0.04


Shortening Bending 0.08 -0.15
SUB TOTAL 10.66 -7.45

P/A 6.55 6.55


Pe/Z 15096 -1.98 1.20

Differential Temp 0.00 0.00

SUB TOTAL 4.56 7.75

TOTAL 15.22 0.30


ALLOWABLE STRESS : Tension=0MPa, Compression=27.0 MPa (fci=45)

382911262.xls Page 2 08:54:44 03/30/2018


Top slab Layer
Layer No of 5/19 Area Y AxY
1 23 43700 2490 1.09E+08
2 4 7600 2240 1.70E+07
3 4 7600 1990 1.51E+07
4 0 0 1570 0.00E+00

Total 31 58900 1.41E+08


Distance to centroid measured from girder underside
= 2393.2258

Bottom slab Layer


Layer No of 5/19 Area Y AxY
1 10 19000 210 3.99E+06
2 2 3800 460 1.75E+06
3 2 3800 710 2.70E+06
4 0 0 0.00E+00

Total 14 26600 8.44E+06


Distance to centroid measured from girder underside
= 317.14286