Professional Documents
Culture Documents
Analiza I Proracun Kombinovanog Rezima Rada Ejektora I Centrifugalne Pumpe PDF
Analiza I Proracun Kombinovanog Rezima Rada Ejektora I Centrifugalne Pumpe PDF
Abstract.Major facilities substations is: centrifugal pumps, ejectors (water power stations),
heat exchanger water to water, traps dirt, heat accumulators, dearatori, control and regulation
of different fittings and pipe thermal insulation.Ejectors due to its simple construction, they
found large use in thermal water networks that are connected to the heating system.The paper
analyzes the combined ejector mode, and centrifugal pumps, depending on the heat capacity
of heating systems. Analyzed three modes of the system, as follows:working together ejectors
and centrifugal pumps (mode 1); ejector for a pump is switched off (mode 2);ejector pump is
off and running (mode 3). Are analyzed and calculated the basic structural and hydraulic
characteristics of the ejector.
1
Povratak na sadržaj
ΔPS f ⎡ ⎛ 1 ⎞ u2 f
(
= ϕ12 1 ⎢2 ⋅ ϕ 2 + ⎜⎜ 2 ⋅ ϕ 2 − 2 ⎟⎟ ⋅ ⋅ 1 − 2 − ϕ 32 ⋅
(ρ + u ) ⋅ (1 + u ) ⋅ f1 ⎤ =
) ⎥
ΔPR f3 ⎣ ⎝ ϕ4 ⎠ ρ f2 ρ f3 ⎦
(1)
d ⎡ ⎛ 1 ⎞ u 2 (d1 d 3 ) 2 (ρ + u ) ⋅ (1 + u ) d1
⎤
2
( )
2 2
= ϕ12 1
⎢ 2 ⋅ ϕ + ⎜
⎜ 2 ⋅ ϕ − ⎟ ⋅ ⋅ − 2 − ϕ ⋅ ⎥
ϕ 2 ⎟⎠ ρ 1 − (d1 d 3 ) ρ
2 2 2 4 2 3 2
d ⎣
3 ⎝ d3 ⎦
• PR
toplotno opterećenje grejnog sistema QGR za projektnu temperaturu spoljneg
PR
vazduha t SP ;
• PR
temperatura razvodne vode t RW PR
pri spoljnoj projketnoj temperaturi t SV ;
• PR
temperatura mešane vode t MW PR
pri spoljnoj projketnoj temperaturi t SV ;
• PR
temperatura posle sistema grejanja t PW PR
pri spoljnoj projketnoj temperaturi t SV ;
• gubitak pritiska u sistemu grejanja pri razmatranom režimu rada sistema ΔPT ;
QGRPR
QGRPR PR
G2 t RW − t MW
PR
G1 = (2); G = (3); G = G = G − G (4); u = = (5)
(
c ⋅ t RW
PR
)
− t PW
PR 3
(
c ⋅ t MW
PR
)
− t PW
PR 2 IN 3 1 PR
G1 t MW − t PW
PR
( )
Provodnost a kg s ⋅ Pa 0,5 ili otpor 2
S (Pa ⋅ s
kg 0,5 ) , sistema grejanja izračunava se po
G3 1 Δp 1
izrazu: a = = ; (6) S SG = 2T = 2 (7)
ΔpT S SG G3 a
2
Povratak na sadržaj
Pri proračunu optimalnog preseka ejektora veličina n nije unapred data . Predhodno se zadaje
njena vrednost a zatim se posle koriguje vrednost f 3 f1 . Iz zajedničkog rešavanja jednačine
(1) i (7) bez predhodnog proračuna optimalnog odnosa ( f 3 f1 )op dobija se:
ΔpS ρ ⋅ ϕ12 ⋅ ϕ 23
= (9)
ΔpR ( ) ( )
2 − ϕ 32 ⋅ (1 + u ) ⋅ (ρ + u ) − 2 ⋅ ϕ 2 − 1 ϕ 42 ⋅ u 2 ⋅ n
Δp S ρ ϕ2 1+ u
= 2 ⋅ ϕ12 ⋅ ϕ 2 ⋅ ⋅W3 ⋅ (1 + W2 ⋅ u ) − W22 ⋅ ρ ⋅ 12 − W32 ⋅ (2 − ϕ 32 )⋅ ⋅ ρ ⋅ ϕ12 (10)
Δp R ρ +u ϕ4 ρ +u
ϕ 22 ⋅ ϕ 42 ⋅ u ϕ 2 ⋅ (1 + u )
W2OP = (11); W3OP = (12)
(2 − ϕ 3 )⋅ (1 + u ) ⋅ (ρ + u ) − u ⋅ ϕ 2 ⋅ ϕ 4
2 2 2 2
(2 − ϕ 3 )⋅ (1 + u ) ⋅ (ρ + u ) − u 2 ⋅ ϕ 22 ⋅ ϕ 42
2
Smenom izraza (11) i (12) u izrazu (9) i nakon sređivanja imamo da je odnos:
ΔpS ϕ 22 ⋅ ϕ12 ⋅ ρ
= (13)
ΔpR (2 − ϕ32 )⋅ (1 + u ) ⋅ (ρ + u ) − u 2 ⋅ ϕ 22 ⋅ ϕ 42
Iz jednačina (11) i (12) proizilazi da je optimalni odnos površina ( f1 f 3 )op jednak izrazu:
f1 ϕ2 ⋅ ρ
= (14)
f 3 (2 − ϕ 3 ) ⋅ (1 + u ) ⋅ (ρ + u ) − u 2 ⋅ ϕ 22 ⋅ ϕ 42
2
Na osnovu jednačina (7) i (14) možemo zaključiti da smo primenom osnovne jednačine (9)
izbegli veličinu n . Na osnovu jednačine (1) dobijaju se jednačine za proračun optimalnog
odnosa poprečnih površina ejektora bezdifuzora i postignutog pada pritiska u ejektoru:
f1 ϕ2 ⋅ ρ f1 ϕ2 ⋅ ρ
= (15); =
(
f 3 2 ⋅ (ρ + u ) ⋅ (1 + u ) − 2ϕ 2 − 1 ϕ 42 ⋅ u 2 ⋅ n) f 3 2 ⋅ (ρ + u ) ⋅ (1 + u ) − u 2 ⋅ ϕ 22 ⋅ ϕ 42
(16);
Δp S ρ ϕ12ϕ 23 Δp S ρ ϕ12ϕ 23
= (17); = (18);
Δp R 2 ⋅ (1 + u ) ⋅ (ρ + u ) − (2 ⋅ ϕ 2 − 1 ϕ 42 )⋅ u 2 ⋅ n Δp R 2 ⋅ (1 + u ) ⋅ (ρ + u ) − u 2 ⋅ ϕ 22 ⋅ ϕ 42
3
Povratak na sadržaj
Δp3
=
( )
2 − ϕ32 (1 + u )(ρ + u ) − 2ϕ 2 − 1 ϕ 42 u 2 n
(19);
Δp3
=
( )
2 − ϕ 32 (1 + u )(ρ + u ) − u 2ϕ 22ϕ 42
(20)
( )
ΔpS 2(1 + u )(ρ + u ) − 2ϕ 2 − 1 ϕ 42 u 2 n ( ΔpS )
2(1 + u )(ρ + u ) − u 2ϕ 22ϕ 42
lim(Δp3 ΔpS ) =
(2 − ϕ ) − ϕ
2
3
2
2 ⋅ ϕ 42
=
0,37662
= 0,3174 ,
u →∞ 2 − ϕ ⋅ϕ 2
2
2
4 1,1866
Iz gore navedenog se može utvrditi , pad pritiska koji se realizuje ejektorom bez difuzora
manji je od pada pritiska kod ejektora sa difuzorom za vrednost od 33-60%. Polazeći od
jednačina (7) do (20) može se izvesti jednačina za određivanje optimalnog odnosa ( f 3 f1 )opt
u funkciji zadanog odnosa raspoloživog pada pritiska i razlike koju stvara ejektor . Za ejektore
sa difuzorom i bez difuzora imamo sledeće odnose optimalnih odnosa:
Δp r Δp Δpr Δp
( f3 f1 )opt = ϕ12 ⋅ ϕ 2 = 0,88 ⋅ r (21); ( f3 f1 )opt = ϕ12 ⋅ ϕ 2 = 0,88 ⋅ r (22);
Δp S Δp S ΔpS ΔpS
m1 v1
f1 = (22)
ϕ1 2 ⋅ Δpr
Rešavanjem jednačina (7) ,(8) i (22) , odnosno (8) ,(15) i (22) dobija se jednačina za proračun
optimalnog poprečnog preseka komore za mešanje ejektora:
(2 − ϕ ) − (2ϕ ) (1 + uu)(ρ + u )
2
u2
2
− 2 ϕ 42 n 0,595 − 0,3906n
f 3opt =
3 2
=
(1 + u )(ρ + u ) (23)
2S mr v s S mr v s
(2 − ϕ )− ϕ ϕ (1 + uu)(ρ + u )
2
u2
2 2 2
0,595 − 0,407
f 3'opt =
3 2 4
=
(1 + u )(ρ + u ) (24)
2 S mr v s S mr v s
u2 u2
595 − 407 595 − 407
f '
=
(1 + u )2 (24a) odnosno d 3' opt = 1,1287
4 (1 + u )2 (24b)
3opt
S mr S SG
4
Povratak na sadržaj
20 5,05
f 3opt = (24b) odnosno prečnik komore mešanja je d 3opt = (24c)
S mr S mr
ΔpS = S mr ⋅ m1 ⋅ (1 + u ) ⋅ vS2
2
(25)
2ϕ 2 f 3
f 1opt = =
⎡ ⎛ u ⎞ 1 f3 ⎤
2
(1 + u )⎢2S mr f 3 ρ + u + 2 − ϕ 32 ρ + u − 2ϕ 2 − 1 ϕ 42
2
ρρ 3 1 + u
( )
ρ (1 + u )
( ) ⋅ ⎜⎜ ⎟⎟ ⎥
⎢⎣ ⎝ ρ + u ⎠ ρ f 2 ⎥⎦
(26)
f3
=
⎡ 2
⎤
(1 + u )2 ⎢0,001026 ⋅ S mr ⋅ f 32 + 0,61 − 0,4n ⋅ ⎛⎜ u ⎞⎟ ⎥
⎢⎣ ⎝ 1 + u ⎠ ⎥⎦
d3
d 1OP = (27)
2
⎛ u ⎞
(1 + u ) 0,00063 ⋅ S mr ⋅ d 34 + 0,61 − 0,4 ⋅ n ⋅ ⎜ ⎟
⎝1+ u ⎠
G12 G12
Δpr = = (31) (28) G1 = 1110 ⋅ d14 ⋅ Δpr = 33.32 ⋅ d12 ⋅ Δpr (29)
⎛ π ⋅ d12 ⎞
2
1110 ⋅ d14
2 ⋅ ϕ ⋅ ⎜⎜
2
1 ⎟⎟ ⋅ ρ r
⎝ 4 ⎠
Na osnovu formule (28), na slici 2 je prikazana zavisnost protoka od pada pritiska i prečnika
mlaznice.
5
Povratak na sadržaj
8,00
30,000
7,00
25,000
6,00 0,015
0,015 20,000 0,02
D1opt (m m )
5,00
D1op(m m )
0,02
0,025
4,00 0,025 15,000
0,03
0,03
3,00 0,035
0,035 10,000
2,00 0,04
5,000
1,00
0,000
0,00
0 20000 40000 60000 80000 100000 120000 140000 160000 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5
Ssg(Pa*s^2/m^6) U
(W ) , temperature vode t PW
14
PR PR PR PR 0
13 QGR , t RW , t MW
pad pritiska u grejnom sistemu ΔpS (Pa) pre
12
6 11
10
2 ⋅ G1 G1 − B + B2 − 4 ⋅ A ⋅ C
d1 = = (30) u= (31)
4 2 ⋅ ϕ12 ⋅ π 2 ⋅ ρ r ⋅ Δp r 4 1110 ⋅ Δp r 2⋅ A
B ⎛ 1 ⎞ f ⎛ f B⎞
Pri ćemu je : B = 2 ⋅ (2 − ϕ 32 ) + 2 ⋅ S SG ⋅ ρ ⋅ f 32 ; A = [ ] − ⎜⎜ 2 ⋅ ϕ 2 − 2 ⎟⎟ ⋅ 3 ; C = −⎜⎜ 2 ⋅ ϕ3 3 − ⎟⎟ ;
2 ⎝ ϕ4 ⎠ f 2 f1 2 ⎠
⎝
PR
t RW + u ⋅ t PW
PR
Efektivna potrošnja i temperatura mešne vode je : G3 EF = G1 ⋅ (1 + u ) , t MW
EF
= (32)
1+ u
2.ANALIZA REŽIMA ZAJEDNIČKOG RADA EJEKTORA I PUMPE
U pojedinim slučajevima na grejnim sistemima može maći primena spajanja nisko naporne
pumpe na usisnoj strani ejektora. Principijelna šema i dijagram promene pritiska rada
ejektora i centrifugalne pumpe prikazana je na slici 3.
6
Povratak na sadržaj
Sr
B
; AEJ = EJ − ϕ12 ⋅ ⎜⎜ 2 ⋅ ϕ 2 − 2 ⎟⎟ ⋅ 1 ;
2 ϕ4 ⎠ f3 ⋅ f 2
(34)
⎝ f3 ⎠ ⎝
S 1 SUCP ⎛ f B ⎞
A = AEJ + SG + ; CEJ = −⎜⎜ 2ϕ12ϕ 2 1 − EJ ⎟⎟
S r 1 − Δp0 Δp ISEJ S r ⎝ f3 2 ⎠
S Δp0 Δp ISEJ
C = C EJ + SG −
S r 1 − Δp0 Δp ISEJ
[
GR = (Δp ISEJ − Δp0 ) S R − u 2 ⋅ SUCP ( )] 0,5
(35)
7
Povratak na sadržaj
S SG SUCP 2 ⋅ S SG S
A = AEJ + + ; B = BEJ + ; C = C EJ + SG ; (36)
Sr Sr Sr Sr
[ (
GR = Δp ISEJ S R − u 2 ⋅ SUCP )]
0,5
(37)
2.3. Analiza režima rada bez ejektora radi samo centrifugalna pumpa (režim 3)
Potrošnja vode u sistemu grejanja pri isključenju ejektora iz sistema izračunava se po izrazu:
G R = [Δp0 (S EJ + S SG + SUCP )]
0,5
(38)
d0
Dužina konusnog dela igle u mlaznici pri potpunom
zatvaranju i dužina koničnog dela igle unutar mlaznice
jednake su izrazima:
Z l1
l l1 = (d 0 − d1 ) 2tgα ; l = l1 + z ()
1 1
ϕ1 = =
1 2 ⋅ E ⋅ l ⋅ f12 1 d 0 − d1 + 2 ⋅ z ⋅ tgα
− − 0,032386 ⋅ E ⋅ d14 ⋅
ϕ2
1, POC d ek5, 25 ϕ2
1, POC (z ⋅ sin α )5, 25
8
Povratak na sadržaj
4.ZAKLJUČAK
Na osnovu izvedenih izraza možemo reći sledeće: sa povećanjem otpora sistema
grejanja optimalni prečnik mlaznice ostaje konstantan, to jest ne zavisi od otpora sistema
grejanja; sa povećanjem koeficijenta injekcije optimalni prečnik mlaznice ejektora
opada.Nagli pad je između vrednosti koeficijneta injekcije 0 i 1. Između vrednosti
koeficijenta injekcije 1 i 4 opadanje vrednosti koeficijenta injekcije je sporije; sa povećanjem
ugla mlaznice α vrednosti brzinskog koeficijenta se ne menjaju, preciznije, promena je
toliko mala (oko 2%) da se može zanemariti; zavisnost masenog protoka od veličine pada
pritiska i prečnika mlaznice prikazana je na slici 2.Dijagram zajedničkog rada ejektora i
centrifugalne pumpe je prikazan na slici 3.
5.OZNAKE
Δp0 -pad pritiska stvoren centrifugalnom pumpom pri nultoj potrošnji, Pa ; SUCP -unutrašnji
otpor centrifugalne pumpe u jednačini karakteristike ove pumpe, Pa ⋅ s 2 kg 2 ; GCP , Gr -
Δp
potrošnja vode kroz pumpu i mlaznicu ejektora, kg s ; S CG = SG -otpor sistema grejanja,
GSG
Δp 1
Pa ⋅ s 2 kg 2 ; S r = 2r = -otpor mlaznice ejektor , Pa ⋅ s 2 kg 2 ; S EJ -otpor
Gr 2 ⋅ ϕ1 ⋅ f12 ⋅ ρ r
2
ejektora , Pa ⋅ s 2 kg 2 ;
6.LITERATURA
[1]N.M.Zinger: Gidravličeskie i tepolovie režimi teplofikacionjih sistem, Moskva,
Energoatomizdat, 1986
[2] Sokolov,E.J., Zinger.N.M.: Struinje aparati, Energija, str. 288. , Moskva,1970.
[3] Bajmak ,Š.:Doktorski rad , Priština , 1994
[4]Berman ,D.L.: Harakteristiki vodjanjih strujnjih nasosov (elevator) i ih rasčet,
Teploenergetika No.8, str.32-35, 1985
[5] Berman,D.L., Efimočkin, G.I.: Metodika rasčeta vodostrujnogo ežektora, Teploenergetika
, 1964. No.8, str. 92-94 , 1985
[6]Limajev B.F.:Gidrostrujinje nasosi i ustanovki , Mašinostrojenije, str.256.Lenjingrad 1988
[7]Sokolov , E.J.: Savremennie problemi teplifikacii , Energetika ,1979, No.4.str 47-56
[8]Bajmak , M.Š.:Snabdevanje industrijskih objekata vodenom parom , Monografija.
Univezitet u Prištin, 2011.
9