Design Forces
∑dn= 8128 mm
h1= 1227 mm
hn= 408 mm
γr = 1.25 for flush connections
Maxial= P/2*(h-tf)
= 0 kNm
M= M+Maxial
= 1989 kNm
Mu= 1.5*(M+Maxial)
= 2984 kNm
Flange Force, Ff= M/(h-tf)
= 1505 kN
1. required bolt dia, db,req
= (2*Mu /(∏*φ*Ft*∑dn))^0.5
= 19.9 mm
Acceted, db = 20 mm
s= 1/2*(bp*g)^0.5
= 81 mm
pf = 60.00 mm ≤s 60.00 mm = pf, use
Y= bp/2*(h1/pf+h2/s)+2/g*(h1*(pf+0.75pb)+h2*(s+0.25*pb)) + g/2
= 22111 mm
Pt= ∏*db *Ft/4
2
= 247 kN
φMnp= φ(2*Pt*(∑dn))
= 868 kNm
tp,reqd = sqrt(1.1*γr*(φMnp)/(φb*Fpy*Y))
= 15.0 mm
Use, tp = 16.0 mm
3. Check for Shear
4. Weld design
a) Top Flange to end plate weld
Dreqd= Ff/((2*(bf -tf)-tw)*0.928)
= 19.2
Use 20 /16 inch
AISC, Table 1D
-7.713 ### 0.1753 44.0
Nominal Dia
BoltNominal
Allowable Shear
of Bolt (A325N)
ShearArea
Stress (Spec -- TableJ3.2)
( mm()Kips( )sq in) ( ksi)