You are on page 1of 1

BLOK DIAGRAM FURNACE 15F-102 (SUPERHEATER STEAM), UNIT RCU

(Tanggal 1/8/17)

Flue Gas
Flue gas
Panas yang hilang
Steam In T = 304,450C
flow = 146,03 Ton/h CO2
T = 260,00 oC H2O
O2
P = 44,00 Kg/cm2
N2
Steam
Economizer

Steam
Furnace
Fuel Gas Steam
15F-102
Steam Out
Kondisi Fuel Gas flow = 146,03 Ton/h
Udara suplai T = 327,57 oC
T = 33,67 oC T = 320C P = 44,00 Kg/cm2
flow = 1097,98 NM3/h Rh = 80 %
GHV = 1967,796 Kj/kg O2 Excess = 4,04%
NHV = 1770,09 Kj/kg O2 = 21%
T.MW = 15,40 Kg/Kmol N2 = 79%
SPGR = 0,531

Komposisi Fuel Gas


CH4 = 41,02% C4H10 (i) = 0,91%
C2H6 = 5,31% C4H10 (n) = 1,33%
C2H4 = 0,08% C5H12 (i) = 0,34%
C3H8 = 3,01% C5H12 (n) = 0,15%
C3H6 = 0,75% C6H14 = 0,18%
C4H8 = 0,10% CO = 0,21%
C4H8 (cis) = 0,09% CO2 = 3,59%
C4H8 (1+i) = 0,17% H2 = 38,91%
C4H8 (trans) = 0,12% N2 = 3,73%
Total = 100 %