You are on page 1of 23

Steel Beam Colum Design

WORKSHOP BUILDING
RING 3,5m

Design Data
Using WF Section 200.100.8.5,5
W = 21.30 kg/m h = d - 2(tf+r) Sy = 27 cm3
A = 27.16 cm2 = 184 mm iy = 2.22 cm
d = 200.00 mm Ix = 1840 cm 4

tw = 5.50 mm Sx = 184 cm3 J= 43450.33 mm4


bf = 100.00 mm ix = 8 cm Iw = 1.2349E+10 mm6
tf = 8.00 mm Sy = 27 cm3 fy = 240 Mpa
Iy = 134 cm 4

Lb = 3.5000 m
Nu = 6397 N
Mux = 4606300 Nmm
Muy = 3600000 Nmm
Cb = 2.58
Zx = 200152 mm^3
fr = 70 Nmm

Bending Capacity Control Based on Local Buckling Condition


- Flange Compactness Control

10.9735

28.3777

bf/2tf = 6.25

Compact Section
Mp = 48036480 Nmm
= 48.03648 kNm

Mr = = 31280000 Nmm
= 31.28 kNm
Moment capacity based on flange local buckling condition =
For Compact Section:

= 48.03648 kNm
For Non Compact Section:

= 52.5841298298 kNm
For Slender Section:

= 644.85376 kNm

Hence for compact flange section, moment capacity based on flange local buckling condition shall be:

48.03648 kNm

- Web Compacness Control

= 108.444

108.4435336938

= = 164.60179

d/tw = 36.36364

Compact Section
Moment capacity based on web local buckling condition =
For Compact Section:

= 48.03648 kNm

For Non Compact Section:

= 69.5436525841 kNm

For Slender Section:


= 640.916203125 kNm

Hence for compact web section, moment capacity based on web local buckling condition shall be:

48.03648 kNm

Moment capacity based on local buckling condition =


48.03648 kNm

Major Axis Bending Capacity Control Based on Lateral Torsional Buckling Condition

1127.911485889 mm
1.1279114859 m
16581.28780951

0.0001032932

3748.1266 mm
3.7481266 m

Lp < Lb < Lr Medium Span Beam

- For short span beam :


Mn = Mp = 48036480 Nmm
= 48.03648 kNm

- For medium span beam :

31280000 Nmm
31.28 kNm

84796315.2409959 Nmm
= 84.796315241 kNm

Use = 48.03648 kNm

- For Long Span Beam :

8.8573E+07 Nmm
88.5731758926 kNm

Use = 48.03648 kNm

Hence for medium span beam, moment capacity based on lateral torsional buckling condition shall be:
48.03648 kNm

Hence bending capacity of the section shall be:


48.03648 kNm
alpha 0.5
d' 192
cw 1.2288E+10
dition shall be:
dition shall be:
Steel Beam Colum Design
Berau Bridge
Cantilever

Design Data
Using WF Section 200.100.8.5,5
W = 0.00 kg/m h = d - 2(tf+r) Sy = 112 cm3
A = 61.46 cm2 = 328 mm iy = 4.00 cm
d = 350.00 mm Ix = 13123 cm 4

tw = 7.00 mm Sx = 750 cm3 J= 104985110.70 mm4


b = 175.00 mm ix = 15 cm
tf = 11.00 mm Sy = 112 cm3 fy = 410 Mpa
Iy = 983 cm4

Lb = 0.5000 m
Nu = 2093 N
Mux = 46843 Nmm
Muy = 0 Nmm
Cb = 1.228
Zx = 840847 mm^3
fr = 130 Nmm

Bending Capacity Control Based on Local Buckling Condition


- Flange Compactness Control

= 24.6932

= 30.8665

bf/tf = 15.90909

Compact Section
Mp = 344747270 Nmm
= 344.74727 kNm

Mr = = 209972000 Nmm
= 209.972 kNm
Moment capacity based on flange local buckling condition =
For Compact Section:

= 344.74727 kNm
For Non Compact Section:

= 536.52219434 kNm
For Slender Section:

= 790.39983 kNm

Hence for compact flange section, moment capacity based on flange local buckling condition shall be:

344.74727 kNm

- Web Compacness Control

Ny = Ag x fy = 2519860 N
φNy = 2267874 N
Nu / φNy = 0.00092 < 0.125

82.7587

57.5125

= 32.842

82.7587365837

= = 125.84953

d/tw = 50

Compact Section
Moment capacity based on web local buckling condition =
For Compact Section:

= 344.74727 kNm

For Non Compact Section:

= 447.206927563 kNm

For Slender Section:


= 1330.22328988 kNm

Hence for compact web section, moment capacity based on web local buckling condition shall be:
344.74727 kNm

Moment capacity based on local buckling condition =


344.74727 kNm

Major Axis Bending Capacity Control Based on Lateral Torsional Buckling Condition

= 2423.218839283 mm
2.4232188393 m

= 61209.486 mm
61.209486 m

Lb<Lp Short Span Beam

- For short span beam :


Mn = Mp = 344747270 Nmm
= 344.74727 kNm

- For medium span beam :

209972000 Nmm
209.972 kNm

428764185.480309 Nmm
= 428.7641854803 kNm

Use = 344.74727 kNm

Hence for short span beam, moment capacity based on lateral torsional buckling condition shall be:
344.74727 kNm

Hence bending capacity of the section shall be:


344.74727 kNm

Minor Axis Bending Capacity Control

Mn = fy x Sy = 46079900 Nmm
46.0799 kNm

Axial Capacity Control


k = 1
Lx = 0.5 m
Ly = 0.5 m

3.422313

12.5

12.5

0.18024

for

0.9667

0.0406092

Use ω = 0.9667142706

2606623.359871 N
2606.623359871 kN

Bending and axial interaction control

0.000945 < 0.2

for

for

0.0010787519 OK

N/A N/A
dition shall be:
on shall be:
Steel Beam Colum Design
WORKSHOP BUILDING
RING 3,5m

Design Data
Using WF Section 200.100.8.5,5
W = 56.60 kg/m h = d - 2(tf+r) Sy = 145 cm3
A = 72.16 cm2 = 378 mm iy = 4.48 cm
d = 400.00 mm Ix = 20000 cm 4

tw = 7.00 mm Sx = 1010 cm3 J= 218169.33 mm4


bf = 200.00 mm ix = 17 cm Iw = 5.4854E+11 mm6
tf = 11.00 mm Sy = 145 cm3 fy = 240 Mpa
Iy = 1450 cm 4

Lb = 12.0000 m
Nu = 6397 N
Mux = 4606300 Nmm
Muy = 3600000 Nmm
Cb = 2.58
Zx = 1105847 mm^3
fr = 70 Nmm

Bending Capacity Control Based on Local Buckling Condition


- Flange Compactness Control

10.9735

28.3777

bf/2tf = 9.090909

Compact Section
Mp = 265403280 Nmm
= 265.40328 kNm

Mr = = 171700000 Nmm
= 171.7 kNm
Moment capacity based on flange local buckling condition =
For Compact Section:

= 265.40328 kNm
For Non Compact Section:

= 275.538764359 kNm
For Slender Section:

= 1673.0549 kNm

Hence for compact flange section, moment capacity based on flange local buckling condition shall be:

265.40328 kNm

- Web Compacness Control

Ny = Ag x fy = 1731840 N
φNy = 1558656 N
Nu / φNy = 0.0041 < 0.125

107.22

75.068

= 42.9256

107.219587208

= = 164.10188

d/tw = 57.14286

Compact Section
Moment capacity based on web local buckling condition =
For Compact Section:

= 265.40328 kNm

For Non Compact Section:

= 347.895625089 kNm

For Slender Section:


= 1416.03345482 kNm

Hence for compact web section, moment capacity based on web local buckling condition shall be:
265.40328 kNm

Moment capacity based on local buckling condition =


265.40328 kNm

Major Axis Bending Capacity Control Based on Lateral Torsional Buckling Condition

2276.145701253 mm
2.2761457013 m

11033.1210311

0.0005067276

6472.3593 mm
6.4723593 m

Lb > Lr Long Span Beam

- For short span beam :


Mn = Mp = 265403280 Nmm
= 265.40328 kNm

- For medium span beam :

171700000 Nmm
171.7 kNm

124524655.861417 Nmm
= 124.5246558614 kNm

Use = 124.5246558614 kNm

- For Long Span Beam :

1.8165E+08 Nmm
181.6495818772 kNm

Use = 181.6495818772 kNm


Hence for long span beam, moment capacity based on lateral torsional buckling condition shall be:
181.6495818772 kNm

Hence bending capacity of the section shall be:


181.6495818772 kNm

Minor Axis Bending Capacity Control

Mn = fy x Sy = 34800000 Nmm
34.8 kNm

Axial Capacity Control

k = 1
Lx = 3.5 m
Ly = 3.5 m

20.95808

78.125

78.125

0.86189

for

1.3985

0.9285644

Use ω = 1.398485394

1238368.314298 N
1238.368314298 kN

Bending and axial interaction control


0.006077 < 0.2

for

for

0.1332934944 OK

N/A N/A
dition shall be:

You might also like