You are on page 1of 2

Rev.No.

Date Responsible
Flow Measurement with Prandtl Tube
4 Sept 09 BES

Nhà máy Xi-măng Tafico Tafico - 471-FN1 inlet Anemometer and Prandtl Tube
Measurements (Rev 4, 2009).xls
Bộ phận Công nghệ sản xuất

Plant Tafico Altitude 25 m


Measuring point loc471-FN1 inlet Ambient pressure 1,010 mbar
Date 16/10/2018 4:20 PM
Remarks

Geometry of Gas Duct Gas Properties


Round ( 8 points ) Static pressure in duct (+/- -7.16 mbar
Circular cross section Absolute static gas pressu 1,003 mbar
Diameter 490 mm Temperature in duct 35.1 °C

Conc. Density
[vol-%] [kg/Nm3]
Cross section 0.189 m2 O2 21.0 1.429
CO2 0.0 1.964
H2O 0.0 0.804
Selected Instrument N2 (sum calc.) 79.0 1.257

Prandtl- or S-Tube (mbar) Average gas density [kg/Nm3] 1.293


[kg/m3] 1.134
Calibration factor 1

Position Axis 1 Axis 2 Average


Measurement Diameter move in move out move in move out corrected Dp
[mm] [mbar] [mbar] [mbar] [mbar] [mbar] [mbar]
1 16 6.70 6.70 2.588
2 51 6.04 6.04 2.458
3 95 6.19 6.19 2.488
4 158 5.76 5.76 2.400
5 332 5.98 5.98 2.445
6 395 6.10 6.10 2.470
7 439 5.70 5.70 2.387
8 474 6.30 6.30 2.510

Average of 8 measuring points 2.47

Gas velocity in the duct 32.77 m/s


Measured gas flowrate 22,250 m3/h
19,520 Nm3/h
6.8

6.6

6.4

6.2

5.8

5.6
Column
G
Column
F
5.4

5.2
1 2 3 4 5 6 7 8

You might also like