You are on page 1of 8

COLUMN DESIGN SOFTWARE

RECTANGULAR COLUMNS WITH UNEVEN BARS


Developed by Ryan Darwin, March 2012

Dimensions: Reinforcing bars on each face:


Width, bx = 1000 mm x - direction: Number Size (mm) Tension side by Compression side
Breadth, by = 1000 mm Tension side = 10 36
Concrete cover = 75 mm Compression side = 5 36
y - direction = 3 28 bx
Materials: y
Concrete, fc' = 28 MPa Steel ratio rg = 1.896% x
Steel rebar, fy = 414 MPa Tie diameter = 16 mm

Number of Load Cases (maximum = 5) = 2

20000
18000
16000
Pu Mux fMn D/C Ratio Remarks
14000
Case 1 3000 4000 3542.4 1.129 Fail!!!
12000 Case 2 2000 2000 3619.9 0.552 Safe!
10000 Case 3 1 1 3550.4 0.000 Safe!
8000 Case 4 1 1 3550.4 0.000 Safe!
Case 5 1 1 3550.4 0.000 Safe!
6000
4000
2000 Note: Press <Ctrl+P> to print.
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
COLUMN DESIGN SOFTWARE
RECTANGULAR COLUMNS WITH UNEVEN BARS
Developed by Ryan Darwin, March 2012

Dimensions: Reinforcing bars on each face:


Width, bx = 800 mm x - direction: Number Size (mm) Tension side by Compression side
Breadth, by = 1000 mm Tension side = 10 25
Concrete cover = 75 mm Compression side = 8 25
y - direction: 4 25 bx
Materials: y
Concrete, fc' = 28 MPa Steel ratio rg = 1.595% x
Steel rebar, fy = 390 MPa Tie diameter = 16 mm

Number of Load Cases (maximum = 5) = 2

14000

12000
Pu Mux fMn D/C Ratio Remarks
10000
Case 1 3000 4000 2401.5 1.249 Fail!!!
Case 2 2000 2000 2245.6 0.891 Safe!
8000
Case 3 1 1 1990.0 0.001 Safe!
6000 Case 4 1 1 1990.0 0.001 Safe!
Case 5 1 1 1990.0 0.001 Safe!
4000

2000
Note: Press <Ctrl+P> to print.
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
COLUMN DESIGN SOFTWARE
RECTANGULAR COLUMNS WITH UNEVEN BARS
Developed by Ryan Darwin, March 2012

Dimensions: Reinforcing bars on each face:


Width, bx = 250 mm x - direction: Number Size (mm) Tension side by Compression side
Breadth, by = 1000 mm Tension side = 5 28
Concrete cover = 75 mm Compression side = 5 28
y - direction: 5 28 bx
Materials: y
Concrete, fc' = 28 MPa Steel ratio rg = 4.926% x
Steel rebar, fy = 390 MPa Tie diameter = 16 mm

Number of Load Cases (maximum = 5) = 2

7000

6000 Pu Mux fMn D/C Ratio Remarks


Case 1 3000 4000 1170.0 3.419 Fail!!!
5000
Case 2 2000 1000 1315.2 0.760 Safe!
4000 Case 3 1 1 1523.5 0.001 Safe!
Case 4 1 1 1523.5 0.001 Safe!
3000 Case 5 1 1 1523.5 0.001 Safe!

2000
Note: Press <Ctrl+P> to print.
1000

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
COLUMN DESIGN SOFTWARE
RECTANGULAR COLUMNS WITH UNEVEN BARS
Developed by Ryan Darwin, March 2012

Dimensions: Reinforcing bars on each face:


Width, bx = 600 mm x - direction: Number Size (mm) Tension side by Compression side
Breadth, by = 1200 mm Tension side = 7 28
Concrete cover = 75 mm Compression side = 5 28
y - direction: 6 28 bx
Materials: y
Concrete, fc' = 28 MPa Steel ratio rg = 2.053% x
Steel rebar, fy = 390 MPa Tie diameter = 16 mm

Number of Load Cases (maximum = 5) = 2

14000

12000
Pu Mux fMnx D/C Ratio Remarks
10000
Case 1 990.16 1292.6 2792.8 0.463 Safe!
8000 Case 2 522.04 2595.06 2760.6 0.940 Safe!
Case 3 1 1 2701.5 0.000 Safe!
6000 Case 4 1 1 2701.5 0.000 Safe!
Case 5 1 1 2701.5 0.000 Safe!
4000

2000
Note: Press <Ctrl+P> to print.
0
0 500 1000 1500 2000 2500 3000 3500
COLUMN DESIGN SOFTWARE
AR COLUMNS WITH UNEVEN BARS
eveloped by Ryan Darwin, March 2012

Compression side