You are on page 1of 5

REVISION CERTIFICATE REV. NO.

DATE JO/EWO DESCRIPTION ENG’G CERT PMT OPRNS

DATE
DATE
DATE
DATE
THIS INDICATES THAT REV. NO ___C______
OF THIS DRAWING IS COVERED, FOR ALL REVISED & RE-ISSUED FOR
C 07/10/2015 BI-10-01055-0004 RKM VGD TBD TBD
DESIGN

APPROVAL/CERTIFICATION REQUIREMENTS
30% DRC/OTHER COMMENTS

AGENCY

OPER-TBD
PROJECT

R. MATLANI
B 09/04/2013 BI-10-01055-0004 INCORPORATED AND ISSUED FOR RM VRD TBD TBD

SAPMT-TBD
ENGINEER
ENGINEER

CERTIFIED
BY DRAWING COMPLETION CERTIFICATE

DISCIPLINE

K. PERIASAMY

V DESHPANDE

OPERATIONS
DESIGN

CONSTRUCTION
07/10/2015
07/10/2015
07/10/2015
(DCC) NO. _________ A 04/15/2013 BI-10-01055-0004 ISSUED FOR REVIEW VRS VRD TBD TBD

JAZAN
TANKS

JAZAN REFINERY & MARINE TERMINAL


NORTH TANK FARM AND LOADING ARM FACILITIES
MECHANICAL DATA SHEET FOR ISOMERATE STORAGE

DAT
DWG. TYPE

SAUDI ARABIA
FOR

15-July-2015

J60
PLANT NO.

JO / EWO:
J60-D-0241/0242

Issued for 90% Design Review

D
INDEX
MECHANICAL DATA SHEET
SAUDI ARABIAN OIL COMPANY

ISOMERATE STORAGE TANKS

REFERENCE FEED DATA SHEET NO. : J60-D-VE-526293 REV C3

DOC.

BI-10-01055-0004
VE-754749

5
1
of
SHT.
NORTH TANK FARM AND LOADING ARM FACILITIES

C
REV.
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Saudi Aramco SDS-ME-09528 (05/2005)

SAUDI ARAMCO

UNTIL CERTIFIED AND DATED


USED FOR CONSTRUCTION
THIS REVISION IS NOT BE
SAUDI ARAMCO STORAGE TANK DATASHEET (API 620 STORAGE TANK) (NOTE 1.7) Date: 07/10/2015

THIS DRAWING AND THE INFORMATION CONTAIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
GENERAL INFORMATION (TO BE COMPLETED BY PURCHASER)
REVISION DESCRIPTION

1. PURCHASER/AGENT SAUDI ARAMCO


ADDRESS JAZAN
REVISED & RE-ISSUED FOR DESIGN

CITY STATE ZIP CODE PHONE


2. USER
3. ERECTION SITE: NAME OF PLANT JAZAN REFINERY & TERMINAL PROJECT
LOCATION JAZAN, SAUDI ARABIA
4. TANK NO. J60-D-0241/0242 NOMINAL CAP. C 15,009 m3 NET WORKING CAP. 12,139 m3
3 3
5. PUMPING RATE: IN 295 m /HR. OUT 520.5 m /HR.
JOB ORDER/EWO NO.

o
6. MAXIMUM OPERATING TEMPERATURE 43 C
BI-10-01055-0004

o
7. PRODUCT STORED ISOMERATE DESIGN SPECIFIC GRAVITY 0.642 AT 43 C
07/10/2015
DATE

o
DESIGN METAL TEMPERATURE 75 (NOTE 1.2) C VAPOR PRESSURE 12,237 mm WATER
8. CORROSION ALLOWANCE: SHELL 3.2 mm ROOF 3.2 mm
(NOTE 1.4 ) BOTTOM 3.2 mm STRUCTURAL (ROOF) 3.2 mm
REV.NO

n
9. SHELL DESIGN: (NOTE 1.5 & 1.7) BASIC STANDARD 620
-0.0029
. DESIGN PRESSURE 0.5 / -0.0025 bar g

10. ROOF DESIGN: n BASIC STANDARD API 620 DOME ROOF


07/10/2015
BY/DATE
OTHER

11. ROOF DESIGN INFORMATION:


N/m2
CONST. AGENCY/DATE OPERATIONS/DATE

UNIFORM LIVE LOAD 1,200


o REQUIRED (SAUDI ARAMCO)

N/m2
REVIEW FOR KEY DRAWINGS

SPECIAL LOADS (PROVIDE SKETCH) NA


TBD

INSULATION LOAD NA N/m2


o
MAXIMUM DESIGN ROOF TEMPERATURE 75 (NOTE 1.2) C

GASES IN THE VAPOR SPACE NOTE 8 OF SHEET 5 OF 5


SAPMT-TBD

12. EARTHQUAKE DESIGN n YES o NO (APPENDIX L) ROOF TIE RODS (5.10.4.5) o YES n NO
SEISMIC ZONE (NOTE 1.1) IMPORTANCE FACTOR C 1.5

ZONE FACTOR (NOTE 1.1) SITE COEFFICIENT (NOTE 1.1)


CERTIFIED/DATE

VGD/07/10/2015

13. WIND LOAD: VELOCITY 45.83 (NOTE 1.3) m/sec


DESIGN CERTIFICATION
( DESIGN AGENCY )

PROVIDE INTERMEDIATE GIRDER n YES o NO *


14. ENVIRONMENTAL EFFECTS: MAXIMUM RAINFALL 90 mm / day
TOTAL SNOW ACCUMULATION N/A mm
RKM/07/10/2015
ENGG./DATE

15. SIZE RESTRICTIONS: MAXIMUM DIAMETER 29.5 m. MAXIMUM HEIGHT 22 m.

16. FOUNDATION TYPE: o EARTH n CONCRETE RINGWALL o OTHER

ENGINEERING NOTES:
1.1 SHORT PERIOD ACCELERATION (Ss)= 43.5%g, 1SEC. PERIOD ACCELERATION (S1)= 12.4%g ,SITE CLASS D AS PER SAES-A-112
C & SUG III AS PER API 620 .
1.2 MINIMUM DESIGN METAL TEMPERATURE IS 16˚C.
APPROVAL AND CERTIFICATION REQUIREMENTS,

1.3 WIND DESIGN PER ASCE 7-05, EXPOSURE CATEGORY = C, IMPORTANCE FACTOR 1.15.
PER SAEP-334, UNDER DRAWING COMPLETION
THIS REVISION NO. C IS COVERED FOR ALL

1.4 ALL WETTED C.S. INTERNAL SURFACES SHALL HAVE 3.2 MM CORROSION ALLOWANCE ON BOTH SIDES.
REVISION VALIDATION

1.5 SHELL COURSE SHALL BE FLUSHED STACKED ON THE INSIDE SURFACE.


1.6 ANNULAR PLATE MATERIAL SHALL BE SAME AS BOTTOM SHELL COURSE PLATE MATERIAL.
1.7 SI UNITS SHALL BE FOLLOWED.
1.8 MINIMUM SHELL COURSE WIDTH SHALL BE 1800 MM
1.9.DESIGN
DESIGNLIFE
LIFEOF
OFTHE
THEEQUIPMENT
EQUIPMENTSHALL
SHALLBE
BE25
25YEARS.
YEARS.

* TO BE FILLED BY TANK MANUFACTURER


CERTIFICATE NO.

MECHANICAL DATA SHEET FOR ISOMERATE STORAGE TANKS DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT. NO. REV. NO.

NORTH TANK FARM AND LOADING ARM FACILITIES DAT


J60 D VE-754749 2
JAZAN REFINERY & MARINE TERMINAL of C
JAZAN SAUDI ARABIA JO / EWO: BI-10-01055-0004
5
Saudi Aramco SDS-ME-09528 (05/2005)

SAUDI ARAMCO

UNTIL CERTIFIED AND DATED


USED FOR CONSTRUCTION
THIS REVISION IS NOT BE
Date: 07/10/2015

THIS DRAWING AND THE INFORMATION CONTAIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
CONSTRUCTION DETAILS (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER)
REVISION DESCRIPTION

1. MANUFACTURER C HIDADA CONTRACTING COMPANY LIMITED


ADDRESS P.O.BOX -11809
REVISED & RE-ISSUED FOR DESIGN

CITY INDUSTRIAL CITY STATE JEDDAH ZIP CODE 21463 PHONE +966 12 6374450 / 6360501
SERIAL NO. CS-13138-10 / 11
2. FABRICATOR C HIDADA CONTRACTING COMPANY LIMITED
ADDRESS P.O.BOX -11809
CITY INDUSTRIAL CITY STATE JEDDAH ZIP CODE 21463 PHONE +966 12 6374450 / 6360501
SERIAL NO. CS-13138-10 / 11
JOB ORDER/EWO NO.

3. MATERIAL SPECIFICATIONS: C SHELL A 516 GR. 70


BI-10-01055-0004

ROOF A 516 GR. 70


07/10/2015
DATE

BOTTOM (NOTE 1.6) A 516 GR. 70


STRUCTURAL A 36
4. NO. OF SHELL COURSES C 11
REV.NO

5. PLATE WIDTHS AND THICKNESS (INCLUDING CORROSION ALLOWANCE), IN mm. C


1. W 2380 x 27 THK 5. W 2380 x 19 THK 9. W 1800 x 12.5 THK
2. W 2380 x 24.5 THK 6. W 2300 x 17 THK 10. W 1800 x 11.5 THK
3. W 2380 x 22.5 THK 7. W 1800 x 15.5 THK 11. W 600 x 52 THK
07/10/2015
BY/DATE
OTHER

4. W 2380 x 20.5 THK 8. W 1800 x 14 THK


6. TANK BOTTOM: PLATE THICKNESS 10 mm n LAP o BUTT SEAMS
C
SLOPE SEE SHEET 5 OF 5 mm/m. o TO n FROM CENTER
7. MINIMUM WIDTH AND THICKNESS OF BOTTOM ANNULAR PLATES, IN mm.: C W755 x 13 THK
C
CONST. AGENCY/DATE OPERATIONS/DATE

8. ROOF-TO-SHELL DETAIL API 620 Figure 5-6 ,Detail-f


9. INTERMEDIATE WIND GIRDER? o YES n NO TOP WIND GIRDER FOR USE AS WALKWAY? o YES n NO
o REQUIRED (SAUDI ARAMCO)

C
REVIEW FOR KEY DRAWINGS

TBD

10. ROOF TYPE: C o SUPPORTED n SELF-SUPPORTED o FLOATING


SLOPE OR RADIUS R29500 mm C (DOME ROOF)

11. ROOF PLATE: THICKNESS 11 mm n LAP o BUTT JOINT


C
12. PAINT: ( NOTE 16,18 &20 ) SHEET 5 OF 5
SHELL / ROOF C EXTERIOR? n YES o NO INTERIOR? n YES o NO
SAPMT-TBD

SURFACE PREPARATION REFER PROJECT SPEC.J60-A-VE-755085 / 755086 & SAES-H-001


BOTTOM UNDERSIDE? n YES o NO INTERIOR? n YES o NO

SURFACE PREPARATION REFER PROJECT SPEC.J60-A-VE-755085 / 755086 & SAES-H-001


STRUCTURAL STEEL EXTERIOR? n YES o NO INTERIOR? n YES o NO
CERTIFIED/DATE

SPECIFICATION REFER PROJECT SPEC.J60-A-VE-755085 / 755086 & SAES-H-001


VGD/07/10/2015

13. TANK BOTTOM COATING: INTERIOR? n YES o NO MATERIAL


DESIGN CERTIFICATION
( DESIGN AGENCY )

APPLICATION SPECIFICATION REFER PROJECT SPEC.J60-A-VE-755085 / 755086 & SAES-H-001


14. INSPECTION BY: SHOP BY TANK MANUFACTURER FIELD BY TANK MANUFACTURER

15. WELD EXAMINATION: RADIOGRAPH AS PER API 620, 32-SAMSS-006 & SAES-W-017
RKM/07/10/2015
ENGG./DATE

SUPPLEMENTARY LIQUID PENETRANT OR ULTRASONIC


16. FILMS AS PER SAES-W-017 PROPERTY OF AS PER CONTRACT

17. LEAK TESTING: BOTTOM AS PER API 620 & 32-SAMSS-006 ROOF AS PER API 620 & 32-SAMSS-006
SHELL AS PER API 620 & 32-SAMSS-006

18. MILL TEST REPORTS: REQUIRED? n YES o NO


PLATE AS PER EN 10204 TYPE 3.1 STRUCTURAL SHAPES EN 10204 TYPE 3.1/2.1

19. PURCHASER REFERENCE DRAWING SHEET 5 OF 5


APPROVAL AND CERTIFICATION REQUIREMENTS,
PER SAEP-334, UNDER DRAWING COMPLETION
REVISION VALIDATION

THIS REVISION NO. C IS COVERED FOR ALL

20. TANK SIZE: DIAMETER 29.5 m HEIGHT 22 m

21. DATE OF STANDARD 620 EDITION/REVISION ELEVENTH EDITION FEB 2008 + ADDENDUM 3 MAR 2012

ENGINEERING NOTES: REFER SHEET 2 AND 5


TBD - TO BE DECIDED LATER
CERTIFICATE NO.

MECHANICAL DATA SHEET FOR ISOMERATE STORAGE TANKS DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT. NO. REV. NO.

NORTH TANK FARM AND LOADING ARM FACILITIES DAT 3


J60 D VE-754749
JAZAN REFINERY & MARINE TERMINAL of C
JAZAN SAUDI ARABIA JO / EWO: BI-10-01055-0004
5
Saudi Aramco SDS-ME-09528 (05/2005)

SAUDI ARAMCO

UNTIL CERTIFIED AND DATED


USED FOR CONSTRUCTION

THIS DRAWING AND THE INFORMATION CONTAIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
THIS REVISION IS NOT BE
Date: 07/10/2015
APPURTENANCES (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER)
REVISION DESCRIPTION

1. STAIRWAY STYLE: C n CIRCULAR o STRAIGHT ANGLE TO HORIZONTAL AS PER DEGREES


REVISED & RE-ISSUED FOR DESIGN

(NOTE 10 & 13) LADDER YES SAES-B-054


2. WALKWAY: WIDTH 760 mm LENGTH 92000 mm
C
(NOTE 10 & 13)
3. DRAWOFF SUMP: STANDARD AS PER API 620 SPECIAL
4. BOLTED DOOR SHEET? o YES n NO
5. SCAFFOLD HITCH C
JOB ORDER/EWO NO.

6. INTERNAL PIPING: SWING LINE NA SUCTION LINE NA


BI-10-01055-0004

HEATING COIL SURFACE AREA mm2


07/10/2015
DATE

7. ROOF DRAIN: HOSE JOINTED


SIPHON
REV.NO

8. NO. AND SIZE OF SHELL MANHOLES SEE SHEET 5 OF 5

9. NO. AND SIZE OF ROOF MANHOLES SEE SHEET 5 OF 5


07/10/2015
BY/DATE
OTHER

10. SHELL NOZZLES: (SEE FIGURE 5-8 AND CLAUSE 5.19 OF API 620) *

FLANGED THREADED ORIENTATION HEIGHT FROM


MARK SIZE SERVICE
SGL DBL SPL A B C D E N=0 BOTTOM
CONST. AGENCY/DATE OPERATIONS/DATE
o REQUIRED (SAUDI ARAMCO)
REVIEW FOR KEY DRAWINGS

TBD

REFER SHEET 5 OF 5 FOR DETAIL


SAPMT-TBD
CERTIFIED/DATE

VGD/07/10/2015
DESIGN CERTIFICATION
( DESIGN AGENCY )

11. ROOF NOZZLES, INCLUDING VENTING CONNECTION: *


RKM/07/10/2015
ENGG./DATE

ORIENTATION DISTANCE
MARK SIZE FLANGED THREADED REINFORCEMENT SERVICE
N=0 FROM CENTER

REFER SHEET 5 OF 5 FOR DETAIL


APPROVAL AND CERTIFICATION REQUIREMENTS,
PER SAEP-334, UNDER DRAWING COMPLETION
REVISION VALIDATION

THIS REVISION NO. C IS COVERED FOR ALL

REMARKS:TANK MANUFACTURER TO ENSURE THAT STRESSES AT TANK NOZZLE DUE TO PIPING LOADS AS PER PROJECT SPECIFICATION
ARE WITHIN THE ALLOWABLE LIMIT.

* TO BE FILLED IN BY THE TANK MANUFACTURER


CERTIFICATE NO.

MECHANICAL DATA SHEET FOR ISOMERATE STORAGE TANKS DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT. NO. REV. NO.

NORTH TANK FARM AND LOADING ARM FACILITIES DAT 4


J60 D VE-754749
JAZAN REFINERY & MARINE TERMINAL of C
JAZAN SAUDI ARABIA JO / EWO: BI-10-01055-0004
5
BY TANK MANUFACTURER

SET PRESSURE OF PVRV (Bar g)=0.365 /-0.002 C


NO. DESCRIPTION QTY ORDER No. DESIGN AND CONSTRUCTION NOTES
SET PRESSURE OF EMERGENCY HATCH (Bar g)= AS PER API620 SEC.-9 ISOMERATE STORAGE TANKS 2 1. SERVICE ISOMERATE - HC
1 BOTTOM PLATES 2. CAPACITY: NOMINAL 15,009 m³ C NET WORKING 12,139 m³
SHELL PLATES COURSES, #1 #2 #3 3. MAX. PUMPING RATE - IN = 295 m³/hr OUT = 520.5 m³/hr
2 #4 #5 #6 #7 #8 #9 #10 #11 #12 TANK MANUFACTURER SHALL MARK EACH UNIT WITH ORDER No. AND ITEM No.
BEVELING IN ACCORDANCE WITH DC-950014-001
3 DOME ROOF WITH SUPPORTS. SPECIFICATIONS AND STANDARDS:
32-SAMSS-006 MANUFACTURE OF LOW PRESSURE TANKS
34-SAMSS-319 RADAR TANK GAUGING EQUIPMENT
BOTTOM APPURTENANCES SAES-A-112 METEOROLOGICAL AND SEISMIC DESIGN DATA
4 WATER DRAW-OFF SUMP 1 SAES-B-054 ACCESS, EGRESS AND MATERIALS HANDLING FOR
5 DRIP RING PLANT FACILITIES
6 PIPE INTERNALS (DIFFUSER & DOWN COMERS) SUPPORTS SAES-D-100 DESIGN CRITERIA OF ATMOSPHERIC AND LOW
7 BEARING PLATES PRESSURE TANK.
8 ANNULAR RING SAES-H-001 COATING MATERIAL SELECTION AND APPLICATION
REQUIREMENTS FOR INDUSTRY PLANTS & EQUIPMENT
SHELL APPURTENANCES AND ACCESSORIES SAES-J-300 LEVEL
9 WELDED SHELL NOZZLE SAES-J-600 PRESSURE RELIEF DEVICES
10 WELDED SHELL NOZZLE SAES-M-001 STRUCTURAL DESIGN CRITERIA FOR NON-BUILDING
11 WELDED SHELL NOZZLE STRUCTURES
12 WELDED SHELL MANWAY SAES-W-017 WELDING REQUIREMENTS FOR API TANKS
13 WELDED SHELL MANWAY SAES-X-600 CATHODIC PROTECTION OF PLANT FACILITIES.
14 WIND GIRDER (AS REQUIRED AS PER DESIGN) SAES-L-109 SELECTION OF FLANGES, STUD BOLTS AND GASKETS
15 GAUGER'S PLATFORM (FOR PIPING REFERENCE ONLY)
16 ELECTRICAL CABLE SUPPORTS SAES-A-004 GENERAL REQUIREMENTS FOR PRESSURE TESTING
17 DELETED C SAES-B-005 SPACING & DIKING FOR ATOMOSPHERIC & LOW- PRESSURE TANKS
18 STAIRWAYS, PLATFORM AND HANDRAILS. SAES-Q-005 CONCRETE FOUNDATIONS
19 ANCHOR CHAIRS( AS REQUIRED PER DESIGN) SAUDI ARAMCO STANDARD DRAWINGS:
20 DELUGE SYSTEM AA-036322-001 ANCHOR BOLT DETAILS (INCH AND METRIC)
AA-036355-001 IMPRESSED CURRENT TANK BOTTOM CATHODIC
ROOF APPURTENANCES AND ACCESSORIES C AA-036504-001 ASSEMBLY AND DETAILS OF GAGE WELL AND
21 ROOF NIPPLE/ NOZZLE GUIDE POLE FOR FLOATING ROOF TANKS
22 WELDED ROOF MANWAY AB-036003-001 MANWAYS AND VENTS FOR TANKS
23 WELDED ROOF MANWAY AB-036387-001 TANKS GROUNDING
24 CIRCULATION VENTS DC-950014-001 BEVELING DETAILS FOR TANKS
25 VAPOUR TIGHT GAUGE HATCH DC-950103-001 STANDARD CIRCUMFERENTIAL STAIRWAY FOR FLOATING
26 PIPE DRAIN ROOF TANKS
27 LIQUID LEVEL INDICATOR C DELETED
28 EMERGENCY VENT (HATCH) AC-036630-001 INSTALATION OF JACK SCREW FOR FLANGED JOINTS
29 ROOF CENTER PIN FOR PAINTERS CABLE PROJECT SPECIFICATIONS:
30 ROOF PLATFORM AND HANDRAILS FOR INSTRUMENTS AND GAUGES J95-A-VE-758384 SPECIFICATION FOR ALLOWABLE NOZZLE LOADS
31 ANTI ROTATION DEVICE J60-A-VE-755085 SPECIFICATION FOR EXTERNAL PAINTING
32 ANTISTATIC CABLE / SHUNTS J60-A-VE-755086 SPECIFICATION FOR INTERNAL LINING
33 DELUGE SYSTEM

QTY = 2 HOLD(S): NIL C

ENGINEERING NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS, UNLESS OTHERWISE NOTED. MATERIAL SPECIFICATION (TANK MANUFACTURER TO CONFIRM)
SR. ASME B16.5 / 2. TANK SHALL BE PROVIDED WITH FOLLOWING INTERNALS AS A MINIMUM: NOZZLE NECK A 106 Gr. B/ A 516 GR 70
NOZZLE MARK NO SIZE (NB) QTY PROJECTION ELEVATION REMARKS
NO. B16.47 SERIES A - VORTEX BREAKER. BOLTING (INT/EXT) A 193 Gr. B8 , A 194 Gr. 8 / A 193 Gr.B7, A 194 Gr.2H
C 1 ISOMERATE INLET N1 16" 300# WNRF 1 $ $ C - CATHODIC PROTECTION LUGS. NOZZLE FLANGES (ASME/API) A 105
2 ISOMERATE OUTLET N2 18" 150# WNRF 1 $ $ WITH VORTEX BREAKER - DRAW-OFF SUMP. R.F.PAD SAME AS SHELL / ROOF PLATE
3 MINIMUM RECYCLE N3 8" 150# WNRF 1 $ $ - DIP PIPES. INTERNAL PIPES A 106 Gr.B
C 4 NITROGEN/VAPOR RECOVERY INLET N4 8" 150# WNRF 1 $ $ - INTERNAL PIPES FOR LEVEL GAUGES AND TEMPERATURE SENSOR. ATTACHMENTS(INT/EXT) A 516 GR 70
C 5 PRESSURE VACCUM RELEIF VENT N5A /B/ C 12"/6"/12' 150# WNRF 3 $ $ 3. THE FOLLOWING EXTERNAL ITEMS SHALL BE PROVIDED AS A MINIMUM: PLATFORM/STAIRWAY A 36
6 UTILITY CONNECTION N6 3" 150# WNRF 1 $ $ - GROUNDING LUGS 4-OFF MINIMUM. SPIRAL WOUND GRAPHITE FILLED SS 316 WINDING
GASKET (ASME NOZZLES)
7 TEMPERATURE SENSOR N8 2" 150# WNRF 1 $ $ WITH STILL WELL - NAMEPLATE AND ITS BRACKET. WITH & SS 316 INNER RING & CS OUTER RING.
8 LEVEL TRANSMITTER N9 8" 150# WNRF 1 $ $ WITH STILL WELL - PIPE SUPPORTS, CLIPS, LADDERS, PLATFORMS AND SPIRAL STAIRWAYS. GASKET (NOZZLE) CNAF
C 9 LEVEL TRANSMITTER N10 4" 150# WNRF 1 $ $ WITH STILL WELL - BLIND FLANGE, GASKET, BOLTING AND DAVITS FOR MANWAYS. FITTINGS A 234 WPB
10 SAMPLE CONNECTIONS N12 (A-L) 2" 150# WNRF 12 $ $ - RADAR GAUGE ASSEMBLY.
11 DEWATERING CONNECTION N13 4" 150# WNRF 1 $ $ WITH SUMP - EXTERNAL CATHODIC PROTECTION LUGS.
12 GAUGE HATCH N14 8" 150# WNRF 1 $ $ WITH STILL WELL, NOTE 11 4. APPURTENANCES ARE PRELIMINARY AND SHALL BE CONFIRMED BY TANK MANUFACTURER.
13 MANWAY (ROOF) MH1 (A/B) 24" 150# WNRF 2 $ $ NOTE 20, WITH COVER & HINGE 5. UPWARD SLOPED BOTTOM PLATE SHALL HAVE 1:120 SLOPE TOWARDS THE PERIPHERY. REQUISITION NO: J60-D-VE-754795
14 MANWAY (SHELL) MH3 (A/B) 24" 150# WNRF 2 $ $ NOTE 20, WITH COVER & DAVIT 6. ANCHOR BOLTS SHALL BE DESIGNED BASED ON AA-036322-001 BY TANK MANUFACTURER VENDOR: HIDADA CONSTRACTING COMPANY LIMITED - K.S.A
C 15 PRESSURE TRANSMITTER N19 (A - C) 2" 150# WNRF 3 $ $ AND SCOPE OF SUPPLY BY OTHERS.
C 16 EMERGENCY HATCH MH5 (A/B) 24" 150# WNRF 2 $ $ NOTE 12, 22 7. ALL REMOVABLE INTERNALS SHALL PASS THROUGH MANWAY INTERNAL DIAMETER. REVISION VALIDATION
17 LEVEL TRANSMITTER N22 4" 150# WNRF 1 $ $ WITH B/F & INT. FLG. 8. NITROGEN BLANKETING SHALL BE PROVIDED IN THE VAPOUR SPACE. THIS REVISION NO. C IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
18 TRANSFER PUMP INLET N21 4" 150# WNRF 1 $ $ CONNECTION FOR VACUUM TRUCK 9. TANK MANUFACTURER TO PROVIDE ANCHOR BOLT SIZES & LAYOUT AND PRIMARY LOADS REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATION NO:
19 SPARE NOZZLE N24 6" 150# WNRF 1 $ $ WITH BLIND FLANGE FOR FOUNDATION.
10 STAIRWAYS SHALL BE PROVIDED WITH STRINGERS AND HANDRAILS ON BOTH SIDES. REVIEW FOR KEY DRAWINGS OTHER
11. GAUGE HATCH SHALL BE PROVIDED WITH SELF CLOSING (SLOT DIPPING) NON-SPARKING COVER. (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
12. EMERGENCY HATCH SHALL BE DESIGNED AS PER API-2000 FIRE CASE FLOW REQUIREMENT AND ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATION/DATE BY/DATE
FOR INSIGNIFICANT BACK PRESSURE
13 ALL STAIRWAYS & WALKWAY SHALL BE IN ACCORDANCE WITH SAES-M-001, SAES-B-054 & 32-SAMSS-006. REV. NO. DATE ENGG REVISION DESCRIPTION
14 ADDITIONAL REQUIREMENT FOR EMERGENCY VENTING SHALL BE CONSIDERED BY TANK
MANUFACTURER AS PER API 2000 C 07/10/2015 RKM REVISED & RE-ISSUED FOR DESIGN

C $ REFER DRAWING No.: 2018IK060030-MS-J60-D-B-EQD-1011 / 1111 15 PAINTING SYSTEM SHALL BE CONFIRMED LATER. THIS DRAWING IS NOT TO BE USED FOR
JOB ORDER / EWO NO.: BI-10-01055-0004 CONSTRUCTION UNTIL CERTIFIED AND DATED
16 ALL FASTENERS SHALL BE COATED WITH FLUORO POLYMER AS PER 7.1 G OF SAES-H-001 .
17 DRIP RING SHALL BE SUPPLIED BY TANK MANUFACTURER. SAUDI ARABIAN OIL COMPANY
23. INSPECTION AND TESTING REQUIREMENT AS PER FORM 175-324900 & API 620. 18 DRIP RING SHALL BE PAINTED AS PER CL 5.11.5.1 OF 32-SAMSS-006 MECHANICAL DATA SHEET FOR ISOMERATE STORAGE TANKS DRAWING TYPE DAT
24. IF SP. GRAVITY OF HYDRO TEST WATER IS MORE THAN 1.0, SAME SHALL BE SPECIFIED IN GA DRAWING 19 DELETED NORTH TANK FARM AND LOADING ARM FACILITIES
AS DESIGN CONDITION BY TANK MANUFACTURER (COMPLYING TO CL.8.4.4.OF SAES-D-100). 20 LONGITUDINAL WELDS OF NOZZLES AND MANWAY NECK FABRICATED FROM PLATE SHALL BE JAZAN REFINERY & MARINE TERMINAL
TEST HEIGHT MAY BE LOWERED TO LIMIT THE INDUCED STRESSES WITHIN APPLICABLE API CODE ALLOWABLE STRESSES. FULLY RADIOGRAPHED. JAZAN SAUDI ARABIA
C 25. PAINTING AND COATING SHALL BE AS PER CORROSIVE INDUSTRIAL ATMOSPHERIC EXPOSURE. 21 DELETED PLANT NO. INDEX DRAWING NUMBER SHT. NO REV NO.
C 22 TANK MANUFACTURER TO CONFIRM SIZE & QTY.
J60 D VE-754749 5 OF 5 C

ISOMERATE STORAGE TANKS


P&ID REFERENCE NO : J60-A-VA-748640-073 / 074 (J60-D-0241/0242)