You are on page 1of 4

24 Hrs NPT Notification Report

Rig Name: Rig 75 Client: PDO NPT Location: Rig Floor


Date of Event : 11-Apr-17 Time: 17:30 Hrs NPT Number: (Rig #/Year/Incident Number) 75/ 17/ 1
Activity At Time Of Event: Tripping Of Drill String Other (Please Specify) Cir & Reciprocate Prior t
Time since last minor (intermediate) service 6-Apr-17 Time since last major service New
Date & Time Event Started (MM/DD/YYYY TIME) 11/4/2017 17:30 PM Date & Time Event Ended (MM/DD/YYYY TIME) 12/4/20
Total Time Lost Due to Event 9 Hrs
Event Severity
Type of NPT NPTR Catatagory Operational (Down Time) System Drilling_System Equipment
Minor
NPT Owner
Manufacturer HH Model Number JC- 70 DB Serial Number JC 10
TP
04/ 11/2017 17:30 Hrs.

On 11th April at 17:30 Mabrook SW2. Circulating & Reciprocating string at 4770 M. Prior to Cut Core.Driller informed Ch Mech & Tool Pusher, a
DW crown block saver engaged. Checked Driller side upper limit crown block saver sensor *OK*. Noticed DW Toggle valve tilted. Clearance bet
Toggle valve and drum wire wound had sufficient clearance & there was no chance to hit the Toggle. Observed Fast line had come out from gro
Toggle valve. Immediately set Slips in Rotary & slack off WOS 189 Tons.

The following for Minor (between 1-3 hrs.) and Moderate (between 3-12 hrs.) Severity only.
Parts Required/Approximate Cost of Parts Used for Repairs USD
Technician Required/Approximate Cost of Technician USD
Logistics Required /Approximate Cost of Logistics USD
Cost of loss Revenue USD 0.00
Toal Cosat of Event USD 0.00
Immediate causes: Underlying / Root Causes
DW crown block saver engaged. Invistigation under process
Noticed Drill line fast end came out, first 4 wraps became loose on Drum

Corrective and Preventive Action (To be uploaded in INTELEX): CA or PA Responsible Person Department
Apply Baker Lock on end of Fast line, installed Additional Clamp on end. PA TP Drilling
Stopped application of Dope on Drill line spooler guide bars, instead using PA TP Drilling
light coat of lubricant oil.

Initial Learning from :


1.Do not ignore any kind of alarm / notification
2..Install Additional retention clamp on fast line end
3.Follow the routine checks on each equipment as instructed in the Check list.
4.Do not apply dope on drill line spooler guide bars, instead use Thin coat of lubricant oil.
5.Take immediate action by following HSE procedure.
6

Photo #1 Photo # 2

DRL-PR-001-FM-01-01
Photo #1 Photo # 2

* Note: Mandatory attach at least two pictures of the Event/Equipment


* Lateral Learning slide to be completed and approved.

Distribution List: CEO, DCEO, DS, HSE Manager, Senior HSE advisor, BD Manager and Quality Dept.

DRL-PR-001-FM-01-01
Floor
/ 17/ 1
ate Prior to Coring.
New Rig
12/4/2017 2:30AM

pment

JC 10 - 006

l Pusher, about the


rance between
t from groove & hit

00
00

Action date
11/4/2017
11/4/2017

DRL-PR-001-FM-01-01
DRL-PR-001-FM-01-01

You might also like