You are on page 1of 1

ISP~I

............. .....
,
SHANMUGHA PRECISION FORGING
NON - CONFORMANCE REPORT
NCR No.: NCR/EI0/ 15 Date: 13 -05-2010

Stage: ~Omiy Inprocess / Final / Customer Complaint

Supplier Name: Supplier DC No : 24 Dt.12.05.2010


Jayam Engineering Tools
GRIN: 162 Dt.13.05.2010
Part No./Rev: 2025872 / 02 Part Name: Bolt GL 312-PF M30

Total Qt}. : 494 Nos Samnle Qtv : 25 Nos


SL. No. Feature Inspected Non-Conformance Identified
\.

1 Dia 6 f7 (-0.01 / -0.022 ) 5.991 - 5.995 - 6 Nos.


2 0.5 +/-0.10 0.53 - 0.61
3 45° +/- 30' 41 ° - 49°
4 0.5 +/-0.10 0.61 - 0.65
5 45° +/- 30' 43° - 47°
6 Visual Step Noticed on Chamfer Both ends

Root Cause:

Action Plan Target Date

-;
Disposition Action : Rejected due to Chamfer Value: 5112/-

Accepted
r: Rejected ::>1 Rework
I Concession 1 Quorantined
(Hold)

Prepared by: 'n./l- Approved by : flY


Name: Shivakumar Name: Sundar.D

Form No:NCR/Ol/RO