Professional Documents
Culture Documents
Pw =h1 x t4 x Fy x 2
Pc = B1 X t1 x 2
Ps = 0.85 x Fc’ x bs x ts
Pt 16800000 N
Pw 38833080 N
Pc 6300000 N
Prb 0 N
Prt 0 N
Ps 26190625 N
i. jika di web
55633080.22 > 32490625 di web
Dcp = 792.6094264 mm
= + − + [ + + + ]
2
Mp 94886538269 N.mm
▪ Yield Moment(My) (AASHTO LRFD Bridge, 2012, D6.2.2)
① Yield Moment of Top Flange
MD1 MD2 + MAD 2.440E+10 2.284E+10 MAD
Fy = + = + + = 350
S Top S Top(3n) S Top(n) 1.113E+08 3.549E+08 3.926E+08
MAD = 2.487E+11 N·mm
MyTop = MD1 + MD2 + MAD = 2.960E+11 N·mm
▪ Flexural Resistance of Composite compact section (AASHTO LRFD Bridge, 2012, 6.10.7.1.2)
ⅰ. Nominal Flexural Resistance in a continuous span
Mn1 = 1.3 Rh · My = 85897647173.611 N·m
ⅱ. Nominal Flexural Resistance by D p
D p > 0.1D t therefore,
Dp
Mn2 = Mp ( 1.07 - 0.7 ) = 77378839138.130 N.mm
Dt
▪ Check Flexural Resistance of Composite compact section (AASHTO LRFD Bridge, 2012, 6.11.7.1)
in which :
Muy = 76237686000.000 N·mm
Фf = 1.000
Ratio = 0.985252
2) Shear Resistance (AASHTO LRFD Bridge, 2012, 6.10.9)
▪ Ratio of the shear-buckling resistance to the shear yield strength, C (AASHTO LRFD Bridge, 2012, 6.10.9.3.2)
▪ Web Classification
Longitudinal Stiffener :
Transverse Stiffener :
Transverse Spacing = 2000.0 mm < 3D = 8411.4 mm
So, this web is considered stiffened web
D E·k
= 155.766 > 1.40 √ = 128.863
tw Fyw
therefore,
1.57 ·( E·k )=
C = 2
0.677
( D ) Fyw
tw
▪ Nominal Resistance of Stiffened interior Webs (AASHTO LRFD Bridge, 2012, 6.10.9.3.2)
Vp = 0.58Fyw · D · =
tw 11383.393 kN
2D · tw
= 0.825 ≤ 2.500
( bfc · tfc + bft · tft )
therefore,
0.87(1-C)
Vn = V p[ C+ d0 2
]= 10905.132 kN
√ 1+( )
D
V ui = 3824.552 ≤ Фv · V n = 10905.132 kN ...... OK
in which :
Фv = 1.000
Ratio = 0.3507112