Preservation of idle equipment installed in the plant involves safeguarding unattended and
inactive equipment from deterioration during their down period, generally above one month
arising out due to the reasons like feed problems, haulage problem, major repairs, revamps,
modifications, retrofitting, etc. Deterioration of equipment during periods of idling is usually
caused by conditions entirely different from those that exist during operation. Many deposits
formed during operations turn usually corrosive under shutdown conditions.
Moisture, oxygen, dirt, dust, ultraviolet rays, extreme pressure and temperature, corrosive
environment of coastal areas and closeness to other chemical plants, are the some of the
factors causing deterioration. Preservation of static and rotary equipment and their spare
parts, which are required to be kept in store for prolonged periods, needs to be carried out to
prevent their deterioration, and as such preservation procedures for the equipment/spares
kept in store should be adopted. New equipment received at plant/project site should be
preserved considering manufacturer’s recommendations.
PRESERVATION METHODS:
If it is expected that site storage will be required for a period longer than the time the
packaging will protect the equipment, additional preservation measures will be taken and
following techniques followed.
External Protection:
The paint specification will be followed. However, attention shall be paid that intermediate
paint coats are applied soonest.
Blank metal parts will be protected by e.g. rustban products of ESSO or SHELL Ensis
Internal Protection:
Systems containing hydrocarbon will be sprayed, flushed or filled with suitable oil. Nitrogen
blankets will be applied and maintained on stainless equipment.
Apply nitrogen blankets preferably after all internal work is finished in order to avoid extensive
purging operations. Nitrogen in a vessel can be dangerous. Apply all necessary warning
plates near all vessel entrances.
All construction personnel shall be familiarized with the risks of nitrogen blankets. This
instruction is the personal responsibility of the safety engineer.
SCOPE:-
This standard lays down the preservation procedures to be followed in oil and gas
installations for various static mechanical equipment installed at plant and for the equipment /
spares kept in stores. The scope does not include the electrical equipment, instruments and
chemicals.
DEFINITIONS
a) Preservation:
Preservation is safeguarding of unattended and inactive equipment from deterioration during
their down period.
b) Coating:
Coating means an application of a coat of preservative media like paint, Oil or grease etc.,
c) Surface Preparation:
Surface Preparation includes cleaning of the parent metal surface for removing foreign
particles like rust, scale, liquid etc., by mechanical or chemical cleaning techniques.
a) Period of shutdown
b) Allowable deterioration and rate of deterioration
c) Probability of reuse
d) Expenditure for repair/replacement
e) Time for repair / replacement after the shutdown
f) Type of protection systems (various alternatives)
g) Condition of the equipment
h) Criticality of the service
i) Type of environment in which equipment/spares are to be stored.
b) Clean all the parts thoroughly by hydro blasting / hydro jetting or chemical cleaning. No
deposits should be left on inside or outside surface of the equipment.
c) Thoroughly coat with preservative oil/grease on the required surfaces including bolting
flange and gasket faces, etc.
d) Reassemble all components, blank off all nozzles and close all vents and drains.
e) All the exposed bolts and flanges to be coated with grease.
f) Austenitic stainless steel component should be suitably passivated before exposure to
atmosphere in line with the procedure as laid down in NACE Standard RP-01-70.
g) Depending on the environmental conditions, coating to be applied on the external surfaces.
If the weather is very humid, completely remove the insulation and apply the paint.
h) For finned air cooler, clean the tubes internally, circulate preservative oil through the tubes
and seal off all the header boxes.
PRESERVATION OF PIPELINES
The following procedures should be adopted
a) Flush the lines clean
b) Open the flange joints and valves at low points to ensure complete draining.
c) Dry the lines or circulate inhibited or uninhibited oil through them
d) Inspect insulated and wrapped lines, uncovering the piping where leaks are suspected.
e) Repair all damaged insulation and wrapping. Bare pipe should be wire brushed and
painted.
f) Lubricate all valves.
g) Spray all external surfaces of the valves with oil and cover valve stem with grease. Relief
valve should be rotated or separated from their discharge piping. Their discharge side should
be sprayed with oil and covered with water proof paper or plastic.
h) Tighten all flanges. Spray mating flanges joints with oil, and wrap them with suitable
wrapper to prevent crevice corrosion between mating flanges.
RETURN BENDS:
CS / Low alloy steel cast plug type return bends should be stored in a covered shed. Grease
preservative shall be applied on all the machined and threaded surfaces. However other type
of return bend can be stored outdoors after applying necessary protective coatings as given
to heater tubes in downward position to avoid any accumulation of water inside the bend.
PRESERVATION of PIPES:
Both CS and low alloy steel pipes can be stored outdoor in a self draining position on a
concrete surface either on steel racks or woody rafter placed in such a position that rain water
does not accumulate and affect pipes. Pipes shall not be allowed to get submerged in ground
or pool of water. Pipes/ pipe fittings shall be protected with an external coat of black
bituminous paint. Pipes shall also be painted internally at the ends, upto a length of 12" or as
practicable.
Stainless steel pipes shall be stored indoor on wooden rafters/ concrete, separate from CS,
with ends opened or plugged. The ink used for marking, if any shall be free from chloride,
sulphur and lead. For pipes with threaded connection, extra care shall be taken in protecting
the threads by putting plastic caps or wrapping with jute cloth.
PRESERVATION of FLANGES:
Flanges with anticorrosive painting shall be stacked on stands / concrete or wooden sleepers
with their gasket seating surfaces at the bottom and covered with tarpaulin. All the flange
gasket seating surface must have a protective coating & extreme care must be taken during
handling to avoid damage. All SS flanges should be stored indoors.
PRESERVATION of FASTENERS:
Fasteners shall be kept indoors. Carbon steel and alloy steel fasteners shall be stored in
separate bays after oil preservation spray. Stainless steel fasteners do not require any
protection.
PRESERVATION of VALVES:
End cover of all the valves shall be plugged by Wooden / Rubber / PVC blanks. Valves shall
be stacked on a concrete surface on wooden rafters, with wooden planks on flanges. Grease
shall be applied on valve steel spindle and flange faces of CS & AS valves. Valves shall be
kept in upright with spindle upward and gate in closed position. All SS valves shall be stored
indoor without any preservative.
PRESERVATION OF STRUCTURAL STEEL:
Structural steel shall be positioned in a way to allow self draining. Structural steel should not
be in contact with soil during preservation.
GENERAL:
Where vendors provide recommendations for site storage and protection, these are to be
followed and take precedence over the following recommendations.
Where prolonged site storage is involved, which is not under the control of vendors,
equipment guarantees are invalidated. However most vendors offer a re-furbishing service
after which equipment guarantees are re-instated. Such a service is outside normal Company
contracts but clients are recommended to take up this option where applicable at their own
expense.
Storage:
Electrical equipment must be stored in the warehouse.
220 and 110 volt electrical supply to be available adjacent to stored motors and equipment to
enable anti-condensation heaters and equipment to be energized where necessary.
Equipment transportation supports and temporary stiffening to be checked for soundness and
repaired as necessary.
All motors to have shafts manually rotated frequently, at least once per week. This must not
be carried out with tools which will damage or mark motor shafts.
Protection:
All damaged painted Mark/Tag Numbers to be reinstated and maintained.
All threaded entries to be plugged and threads recoated with rust preventatives where
necessary.
Where moisture absorbents are included to protect equipment it should be replaced with a
fresh charge immediately on receipt in the site stores and replaced on a regular basis
thereafter.
Motors:
Motor bearings to be checked regularly to ensure grease is in good condition, should it
harden or be discoloured the bearings should be cleaned out and regressed.
All bright metal parts, machined surfaces (i.e. shafts) to be coated with rust preventatives.
All 6000V. Motors should have insulation resistance values measured and recorded every 3
months against climatic conditions at time of test. If the reading is not greater than 6 mega
ohm an approved method of drying out is to be undertaken to achieve acceptable resistance
readings. Connect anti-condensation heaters.
Any separately supplied insulation liquids should be stored on an incline, containers should
not be left stored in upright position.
Spot insulation tests shall be carried out every 6 weeks and where readings are low an
approved drying out procedure shall be adopted to achieve acceptable resistance readings.
Batteries should be stored in an inactive area to avoid accidental breakage and seals should
be regularly checked for damage. Damaged seals shall be renewed in accordance with
Vendors instructions.
Nickel-cadmium and lead-acid batteries that have been shipped dry do not require
maintenance.
Electrolyte levels in batteries that have been shipped wet should be checked and topped up
as required.
Cable:
Measure and record gas pressure in low pressure gas filled cable when received and weekly
thereafter.
If falling pressure indicates a leak in cable, maintain same with dry nitrogen until leak is
sealed.
Rotate reels of paper insulated lead sheathed cable 90° every 2 weeks to prevent migrating
oil from collecting at low points.
INSTRUMENTATION:
General:
Where vendors provide recommendations for site storage and protection these are to be
followed and take precedence over the following recommendations.
Where prolonged site storage is involved, which is not under the control of vendors,
equipment guarantees are invalidated. However most vendors offer a re-furbishing service
after which equipment guarantees are re-instated. Such a service is outside normal Company
contracts but clients are recommended to take up this option where applicable at their own
expense.
Storage:
A warm, clean, dry and vibration free environment in a secure under cover storage area is
required. Recommended environment conditions are temperature range of 15°C to 30°C and
a humidity of between 30 to 40%.
Instruments can be stored in the above environment for up to 4 months in their shipment
cases. However, where cases/packing have been opened the plastic coverings are to be
retained and resealed in the manner they were shipped.
Where moisture absorbents are included they are to be replacing with the new charge on
receipt on site and further replaced at regular intervals thereafter.
Adjacent 220 and 110 volt supply made available for energizing equipment as necessary.
Ensure all Nameplates/Tags/Gland plates are intact and secure, also maintain.
Protection:
Local Instruments:
All openings shall be tightly plugged against entry of water.
Panel Instruments:
The power pack units of the control panel racks shall be energized at monthly intervals. For
storage in original packing refer to recommendation of vendor.
Delicate Instruments:
1. Panel instruments
2. Distribution control components
3. Racks with power supply and/or cards
4. Computer racks and components
5. Programmable controllers
will be stored in air conditioned spaces.
Safety valves shall be stored in the warehouse and either dummy installed in the line or the
lines blanked off.
The valves shall be stored indoors in a clean, dry environment. Avoid extreme temperatures
and humidity conditions.
Ensure all Nameplates/Tags/Gland plates are intact and secure, also maintain.
1. Indoor storage,
2. Not in contact with the soil or with porous supports such as raw wood. Protective coatings
are acceptable alternatives to covered storage.
In addition, austenitic stainless steels shall not be exposed to salt water or salt spray.