Professional Documents
Culture Documents
DISCLAIMER
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any
party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
report. The Client is authorized to permit copying or distribution of this report and then only in its entirety, other forms of
reproduction require written approval from Intertek’s issuing laboratory. Any use of the Intertek name or one of its marks for the
sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations
and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material,
product, or service is or has ever been under an Intertek certification program.
Alkaline primary batteries have been tested in accordance with IEC 60086-2, Ed. 12.0, 2011-
02. Test conditions are according to IEC 60086-1 Ed. 11.0, 2011-02. Discharge time to
specified voltage levels has been determined.
Brands Sizes
This report may not be reproduced other than in full, except with the prior written approval of the issuing
laboratory.
Distribution:
TABLE OF CONTENTS
1. CLIENT.......................................................................................................................... 4
2. COMMISSION ............................................................................................................... 4
3. TEST SAMPLES ........................................................................................................... 4
4. TEST PROGRAM .......................................................................................................... 5
5. TEST CONDITIONS ...................................................................................................... 5
6. TEST RESULTS............................................................................................................ 6
1. CLIENT
Volker Bierhoff
Spectrum Brands (UK) Ltd
Fir Street, Failsworth
Manchester, M35 0HS
ENGLAND
2. COMMISSION
3. TEST SAMPLES
4. TEST PROGRAM
The methods in Table 4.1 are according to IEC 60086-2, Ed. 12.0, 2011-02. These methods
are accredited by SWEDAC.
5. TEST CONDITIONS
Test conditions are according to IEC 60086-1 Ed. 11.0, 2011-02.
Testing was performed on a PEC test system BDT1012 for primary batteries. The batteries
were connected to the discharge circuits by pressure contacts.
Room temperature: 20 ± 2 °C
Humidity: 45 – 65 %
The time to voltage levels / cut-off voltage was determined by scanning every 10 msec and
registration with ∆V and ∆t. The values for ∆V and ∆t are dependent on test regime.
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. RE12-002
4 January 2012
Page 6 of 12
6. TEST RESULTS
Test results are summarized in Tables 6.1-6.6 below.
Tables showing life of individual batteries, discharged to specified end voltages are compiled
in Appendix A.
The time to end voltage is in some tests expressed as pulses. The averages presented in the
result tables are calculated from the number of fully completed pulses of each individual test
sample.
The uncertainty of load resistance is calculated to be less than ±0,5 % based on calibrations.
The requirement according to IEC 60086-1 is ±0,5 %.
The uncertainty of load current is calculated to be less than ±0,5 % based on calibrations.
Measurement uncertainty is reported in accordance with the EA publication EA-4/16 "EA guidelines on the
expression of uncertainty in quantitative testing”, December 2003.
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. RE12-002
4 January 2012
Page 7 of 12
LR6 Photo flash 0,9 V (pulses) 651 656 645 645 652 640 567 575 539
1000 mA 10 sec/min, 1h/d
Motor/Toy 0,8 V (h) 8,57 8,62 8,53 8,54 8,61 8,51 8,35 8,37 8,33
3,9 ohm, 1 h/d
Remote control 1,0 V (h) 50,3 50,6 49,6 49,7 49,9 49,3 47,1 47,2 47,0
24 ohm, 15 sec/min, 8 h/d
Electronic game 0,9 V (h) 9,35 9,42 9,29 9,11 9,30 8,92 8,40 8,44 8,35
250 mA, 1 h/day
Radio 0,9 V (h) 96,9 97,8 95,5 96,2 96,9 94,8 92,5 93,2 91,2
43 ohm, 4 h/day
Digital camera 1,05 V (pulses) 147 148 147 138 147 126 86 87 86
1500 mW/650 mW
2 s/28 s, 5 min/h, 24h/day
Portable lighting 0,9 V (h) 6,06 6,17 5,86 6,22 6,25 6,18 6,04 6,12 5,93
3,3 ohm, 4 min/h, 8 h/day
Digital audio 0,9 V (h) 24,94 25,48 24,63 25,54 26,31 24,99 24,65 24,71 24,56
100 mA, 1 h/day
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. RE12-002
4 January 2012
Page 8 of 12
LR6 Photo flash 519 530 505 460 462 459 377 402 345
1000 mA 10 sec/min, 1h/d
Motor/Toy 8,03 8,52 7,87 7,78 7,89 7,63 7,59 7,67 7,55
3,9 ohm, 1 h/d
Remote control 52,6 52,9 52,4 50,9 51,0 50,6 46,8 47,1 46,5
24 ohm, 15 sec/min, 8 h/d
Electronic game 9,13 9,41 8,90 8,69 8,80 8,56 7,89 8,01 7,75
250 mA, 1 h/day
Radio 100,8 101,2 99,3 97,8 98,6 97,2 92,8 93,5 91,4
43 ohm, 4 h/day
Digital camera 107 109 99 82 89 55 52 59 36
1500 mW/650 mW
2 s/28 s, 5 min/h, 24h/day
Portable lighting 6,64 6,72 6,58 6,25 6,32 6,19 5,68 5,84 5,34
3,3 ohm, 4 min/h, 8 h/day
Digital audio 26,30 26,80 25,70 25,79 25,89 25,74 23,73 24,05 23,10
100 mA, 1 h/day
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. RE12-002
4 January 2012
Page 9 of 12
LR03 Photo flash 0,9 V (pulses) 462 465 456 418 454 403 412 420 405
600 mA 10 sec/min, 1h/d
Portable lightning 0,9 V (h) 4,42 4,46 4,38 4,37 4,40 4,31 4,14 4,19 4,12
5,1 ohm, 4 min/h, 8 h/d
Toy 0,8 V (h) 4,55 4,67 4,47 4,48 4,67 4,26 4,02 4,41 3,87
5,1 ohm, 1 h/d
Digital audio 0,9 V (h) 11,06 11,25 10,93 10,83 10,92 10,74 10,51 10,62 10,40
100 mA, 1 h/d
Radio 0,9 V (h) 75,12 75,55 74,56 74,52 74,91 74,06 72,60 73,27 71,80
75 ohm, 4 h/d
Remote control 1,0 V (h) 22,25 22,37 22,00 21,89 22,28 21,72 20,85 21,04 20,62
24 ohm, 15 s/min, 8 h/d
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. RE12-002
4 January 2012
Page 11 of 12
LR03 Photo flash 434 456 419 420 446 407 288 339 215
600 mA 10 sec/min, 1h/d
Portable lightning 4,40 4,51 4,33 4,33 4,39 4,26 4,14 4,25 4,05
5,1 ohm, 4 min/h, 8 h/d
Toy 4,05 4,49 3,02 4,32 4,46 3,99 3,83 3,93 3,52
5,1 ohm, 1 h/d
Digital audio 10,56 10,69 10,43 10,52 10,65 10,37 9,92 10,36 9,71
100 mA, 1 h/d
Radio 73,99 74,53 73,01 73,71 74,54 71,99 72,00 74,15 70,89
75 ohm, 4 h/d
Remote control 22,04 22,32 21,25 21,88 22,34 21,04 20,95 21,59 20,42
24 ohm, 15 s/min, 8 h/d
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. RE12-002
4 January 2012
Page 12 of 12
This report may not be reproduced other than in full, except with the prior written approval of the issuing laboratory.
Appendix A
Report No. RE12-002
4 January 2012
Page 1 of 42
1 12 27 55 66 94 109
2 18 44 87 107 129 156
3 17 44 87 107 129 156
4 18 44 87 106 129 156
5 19 45 89 109 138 158
6 18 44 87 99 128 148
1 2 16 36 39 55 66
2 7 26 47 57 77 95
3 15 34 57 68 96 115
4 14 29 57 67 89 109
5 15 34 59 77 99 118
6 14 34 57 69 98 117
Average 11 29 52 63 86 103
Std. Dev. 5,4 7,1 9,0 13,3 17,1 20,2
Max. value 15 34 59 77 99 118
Min. value 2 16 36 39 55 66
Appendix A
Report No. RE12-002
4 January 2012
Page 24 of 42
Per Lindström
DISCLAIMER
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any
party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
report. The Client is authorized to permit copying or distribution of this report and then only in its entirety, other forms of
reproduction require written approval from Intertek’s issuing laboratory. Any use of the Intertek name or one of its marks for the
sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations
and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material,
product, or service is or has ever been under an Intertek certification program.
Alkaline primary batteries have been tested in accordance with IEC 60086-2. Test conditions
are according to IEC 60086-1. Discharge time to specified voltage levels has been
determined.
Brands Sizes
This report may not be reproduced other than in full, except with the prior written approval of the issuing
laboratory.
Distribution:
TABLE OF CONTENTS
1. CLIENT.......................................................................................................................... 4
2. COMMISSION ............................................................................................................... 4
3. TEST SAMPLES ........................................................................................................... 4
4. TEST PROGRAM .......................................................................................................... 5
5. TEST CONDITIONS ...................................................................................................... 5
6. TEST RESULTS............................................................................................................ 6
References:
IEC 60086-1, Ed. 11.0, 2011-02
IEC 60086-2, Ed. 12.0, 2011-02
EA guidelines on the expression of uncertainty in quantitative testing, December 2003
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. RE13-104
15 October 2013
Page 4 of 9
1. CLIENT
James McCumesky
Varta Consumer Batteries
Fir Street, Failsworth
Manchester, M35 0HS
United Kingdom
2. COMMISSION
The commission was conducted in accordance with our proposal No. 500478524.
3. TEST SAMPLES
4. TEST PROGRAM
The methods in Table 4.1 are according to IEC 60086-2. These methods are accredited by
SWEDAC.
Samples/test: 9.
5. TEST CONDITIONS
Test conditions are according to IEC 60086-1.
Testing was performed on a PEC test system BDT1012 for primary batteries. The batteries
were connected to the discharge circuits by pressure contacts.
Room temperature: 20 ± 2 °C
Humidity: 45 – 65 %
The time to voltage levels / cut-off voltage was determined by scanning every 10 msec and
registration with ∆V and ∆t. The values for ∆V and ∆t are dependent on test regime.
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. RE13-104
15 October 2013
Page 6 of 9
6. TEST RESULTS
Test results are summarized in Tables 6.1-6.4 below.
Tables showing life of individual batteries, discharged to specified end voltages are compiled
in Appendix A.
The time to end voltage is in some tests expressed as pulses. The averages presented in the
result tables are calculated from the number of fully completed pulses of each individual test
sample.
The uncertainty of load resistance is calculated to be less than ±0,5 % based on calibrations.
The requirement according to IEC 60086-1 is ±0,5 %.
The uncertainty of load current is calculated to be less than ±0,5 % based on calibrations.
Measurement uncertainty is reported in accordance with the EA publication EA-4/16 "EA guidelines on the
expression of uncertainty in quantitative testing”, December 2003.
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. RE13-104
15 October 2013
Page 7 of 9
Motor/Toy 93,1%
Radio/Clock 99,3%
Overall average
91,7%
typical performance
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. RE13-104
15 October 2013
Page 9 of 9
Toy 86,1%
Radio/Clock 101,3%
Overall average
96,7%
typical performance
This report may not be reproduced other than in full, except with the prior written approval of
the issuing laboratory.
Appendix A
Report No. RE13-104
15 October 2013
Page 1 of 29
Per Lindström
DISCLAIMER
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any
party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
report. The Client is authorized to permit copying or distribution of this report and then only in its entirety, other forms of
reproduction require written approval from Intertek’s issuing laboratory. Any use of the Intertek name or one of its marks for the
sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations
and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material,
product, or service is or has ever been under an Intertek certification program.
TABLE OF CONTENTS
1. CLIENT.......................................................................................................................... 4
2. COMMISSION ............................................................................................................... 4
3. TEST SAMPLES ........................................................................................................... 4
4. TEST PROGRAM .......................................................................................................... 5
5. TEST CONDITIONS ...................................................................................................... 5
6. TEST RESULTS ............................................................................................................ 6
References:
IEC 60086-1, Ed. 11.0, 2011-02
IEC 60086-2, Ed. 12.0, 2011-02
EA guidelines on the expression of uncertainty in quantitative testing, December 2003
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1410906STO-001
22 September 2014
Page 4 of 9
1. CLIENT
Natalie Carney
Varta Consumer Batteries
Fir Street, Failsworth
Manchester, M35 0HS
United Kingdom
2. COMMISSION
The commission was conducted in accordance with our proposal No. 18067.
3. TEST SAMPLES
4. TEST PROGRAM
The methods in Table 4.1 are according to IEC 60086-2. These methods are accredited by
SWEDAC.
Samples/test: 9.
5. TEST CONDITIONS
Test conditions are according to IEC 60086-1.
Testing was performed on a PEC test system BDT1012 for primary batteries. The batteries
were connected to the discharge circuits by pressure contacts.
Room temperature: 20 2 C
Humidity: 45 – 65 %
The time to voltage levels / cut-off voltage was determined by scanning every 10 msec and
registration with V and t. The values for V and t are dependent on test regime.
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1410906STO-001
22 September 2014
Page 6 of 9
6. TEST RESULTS
Test results are summarized in Tables 6.1-6.4 below.
Tables showing life of individual batteries, discharged to specified end voltages are compiled
in Appendix A.
The time to end voltage is in some tests expressed as pulses. The averages presented in the
result tables are calculated from the number of fully completed pulses of each individual test
sample.
The uncertainty of load resistance is calculated to be less than 0,5 % based on calibrations.
The requirement according to IEC 60086-1 is 0,5 %.
The uncertainty of load current is calculated to be less than 0,5 % based on calibrations.
Measurement uncertainty is reported in accordance with the EA publication EA-4/16 "EA guidelines on the
expression of uncertainty in quantitative testing”, December 2003.
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1410906STO-001
22 September 2014
Page 7 of 9
Motor/Toy 90,5%
Radio/Clock 97,6%
Overall average
92,9%
typical performance
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1410906STO-001
22 September 2014
Page 9 of 9
Toy 81,1%
Radio/Clock 99,3%
Overall average
98,1%
typical performance
This report may not be reproduced other than in full, except with the prior written approval of
the issuing laboratory.
Appendix A
Report No. 1410906STO-001
22 September 2014
Page 1 of 29
Per Lindström
DISCLAIMER
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any
party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
report. The Client is authorized to permit copying or distribution of this report and then only in its entirety, other forms of
reproduction require written approval from Intertek’s issuing laboratory. Any use of the Intertek name or one of its marks for the
sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations
and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material,
product, or service is or has ever been under an Intertek certification program.
Alkaline primary batteries have been tested in accordance with IEC 60086-2. Test conditions
are according to IEC 60086-1. Discharge time to specified voltage levels has been
determined.
Brands Sizes
This report may not be reproduced other than in full, except with the prior written approval of the issuing
laboratory.
Distribution:
TABLE OF CONTENTS
1. CLIENT.......................................................................................................................... 4
2. COMMISSION ............................................................................................................... 4
3. TEST SAMPLES ........................................................................................................... 4
4. TEST PROGRAM .......................................................................................................... 5
5. TEST CONDITIONS ...................................................................................................... 5
6. TEST RESULTS ............................................................................................................ 6
References:
IEC 60086-1, Ed. 11.0, 2011-02
IEC 60086-2, Ed. 12.0, 2011-02
EA guidelines on the expression of uncertainty in quantitative testing, December 2003
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1413267STO-002
12 November 2014
Page 4 of 9
1. CLIENT
Natalie Carney
Varta Consumer Batteries
Fir Street, Failsworth
Manchester, M35 0HS
United Kingdom
2. COMMISSION
The commission was conducted in accordance with our proposal No. 18067.
3. TEST SAMPLES
4. TEST PROGRAM
The methods in Table 4.1 are according to IEC 60086-2. These methods are accredited by
SWEDAC.
Samples/test: 9.
5. TEST CONDITIONS
Test conditions are according to IEC 60086-1.
Testing was performed on a PEC test system BDT1012 for primary batteries. The batteries
were connected to the discharge circuits by pressure contacts.
Room temperature: 20 2 C
Humidity: 45 – 65 %
The time to voltage levels / cut-off voltage was determined by scanning every 10 msec and
registration with V and t. The values for V and t are dependent on test regime.
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1413267STO-002
12 November 2014
Page 6 of 9
6. TEST RESULTS
Test results are summarized in Tables 6.1-6.4 below.
Tables showing life of individual batteries, discharged to specified end voltages are compiled
in Appendix A.
The time to end voltage is in some tests expressed as pulses. The averages presented in the
result tables are calculated from the number of fully completed pulses of each individual test
sample.
The uncertainty of load resistance is calculated to be less than 0,5 % based on calibrations.
The requirement according to IEC 60086-1 is 0,5 %.
The uncertainty of load current is calculated to be less than 0,5 % based on calibrations.
Measurement uncertainty is reported in accordance with the EA publication EA-4/16 "EA guidelines on the
expression of uncertainty in quantitative testing”, December 2003.
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1413267STO-002
12 November 2014
Page 7 of 9
Motor/Toy 84,8%
Radio/Clock 100,9%
Overall average
87,4%
typical performance
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1413267STO-002
12 November 2014
Page 9 of 9
Toy 82,2%
Radio/Clock 95,5%
Overall average
88,5%
typical performance
This report may not be reproduced other than in full, except with the prior written approval of
the issuing laboratory.
Appendix A
Report No. 1413267STO-002
12 November 2014
Page 1 of 29
1 18 44 79 98 136 159
2 16 36 66 78 107 128
3 18 39 77 96 129 157
4 18 39 77 96 126 147
5 19 45 87 106 129 156
6 17 38 69 89 117 136
7 18 44 77 96 125 138
8 18 39 78 98 128 167
9 18 39 76 89 119 146
1 14 34 56 65 87 99
2 16 35 57 66 88 105
3 14 33 54 59 85 97
4 14 34 55 59 79 97
5 15 34 55 65 85 97
6 13 27 48 56 76 95
7 15 35 57 68 89 106
8 14 34 56 66 86 98
9 13 28 54 58 79 97
Per Lindström
DISCLAIMER
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any
party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
report. The Client is authorized to permit copying or distribution of this report and then only in its entirety, other forms of
reproduction require written approval from Intertek’s issuing laboratory. Any use of the Intertek name or one of its marks for the
sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations
and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material,
product, or service is or has ever been under an Intertek certification program.
Alkaline primary batteries have been tested in accordance with IEC 60086-2. Test conditions
are according to IEC 60086-1. Discharge time to specified voltage levels has been
determined.
Brands Sizes
This report may not be reproduced other than in full, except with the prior written approval of the issuing
laboratory.
Distribution:
TABLE OF CONTENTS
1. CLIENT.......................................................................................................................... 4
2. COMMISSION ............................................................................................................... 4
3. TEST SAMPLES ........................................................................................................... 4
4. TEST PROGRAM .......................................................................................................... 5
5. TEST CONDITIONS ...................................................................................................... 5
6. TEST RESULTS ............................................................................................................ 6
References:
IEC 60086-1, Ed. 11.0, 2011-02
IEC 60086-2, Ed. 12.0, 2011-02
EA guidelines on the expression of uncertainty in quantitative testing, December 2003
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1413267STO-001
12 November 2014
Page 4 of 9
1. CLIENT
Natalie Carney
Varta Consumer Batteries
Fir Street, Failsworth
Manchester, M35 0HS
United Kingdom
2. COMMISSION
The commission was conducted in accordance with our proposal No. 18067.
3. TEST SAMPLES
Photo No. 1: Varta Max Tech Photo No. 2: Duracell Ultra Power
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1413267STO-001
12 November 2014
Page 5 of 9
4. TEST PROGRAM
The methods in Table 4.1 are according to IEC 60086-2. These methods are accredited by
SWEDAC.
Samples/test: 9.
5. TEST CONDITIONS
Test conditions are according to IEC 60086-1.
Testing was performed on a PEC test system BDT1012 for primary batteries. The batteries
were connected to the discharge circuits by pressure contacts.
Room temperature: 20 2 C
Humidity: 45 – 65 %
The time to voltage levels / cut-off voltage was determined by scanning every 10 msec and
registration with V and t. The values for V and t are dependent on test regime.
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1413267STO-001
12 November 2014
Page 6 of 9
6. TEST RESULTS
Test results are summarized in Tables 6.1-6.4 below.
Tables showing life of individual batteries, discharged to specified end voltages are compiled
in Appendix A.
The time to end voltage is in some tests expressed as pulses. The averages presented in the
result tables are calculated from the number of fully completed pulses of each individual test
sample.
The uncertainty of load resistance is calculated to be less than 0,5 % based on calibrations.
The requirement according to IEC 60086-1 is 0,5 %.
The uncertainty of load current is calculated to be less than 0,5 % based on calibrations.
Measurement uncertainty is reported in accordance with the EA publication EA-4/16 "EA guidelines on the
expression of uncertainty in quantitative testing”, December 2003.
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1413267STO-001
12 November 2014
Page 7 of 9
Motor/Toy 100,7%
Radio/Clock 111,5%
Overall average
97,1%
typical performance
TEST REPORT issued by an
Accredited Testing Laboratory
Report No. 1413267STO-001
12 November 2014
Page 9 of 9
Toy 86,5%
Radio/Clock 95,4%
Overall average
93,3%
typical performance
This report may not be reproduced other than in full, except with the prior written approval of
the issuing laboratory.
Appendix A
Report No. 1413267STO-001
12 November 2014
Page 1 of 29