CALCULATION FOR STEEL LAGGING

d
b
W

l l
l

2
Active pressure acting on the plate = 47.67 kN/m ( Factored Pressure )

Load factor FOS = 1

Section properties / classification


2
Normal value of yeild strength fy = 275 N/mm

Thickness of the steel plate d = 25 mm

Steel plate length b = 1000 mm = 1.00 m

Maximum spacing of soldier pile = 1500 mm = 1.5 m

Original elastic modulus Wel = b d2 / 6 = 104167 mm3/m

2
Original area A = bxd = 25000 mm /m

Load acting on steel plate W = 47.67 x 1 = 47.67 kN/m

Ultimate bending moment MEd = W l^2 / 8 x FOS = 20.11 KNm/m

Ultimate shear force VEd = W l / 2 x FOS = 53.63 kN/m

Moment capacity check Mc,Rd = Wel fy / γmo


= 104166.666666667 x 275 / 1.0
= 3E+07 Nmm/m = 28.6 KNm/m

Max. bending moment MEd = 20.11 KNm/m ≤ 28.60 KNm/m OK

Shear capacity check Vc,Rd = Av ( fy / √3 ) / γ mo


= 25000 x ( 275 /√ 3 ) / 1.0
= 4E+06 N = 3969.3 KN/m

Max. shear acting on soldier pile, VEd = 53.63 kN/m ≤ 3969.3 KN/m OK