SALEM CITY MUNICIPAL CORPORATION


Structural Design for RCC Drain of size 0.45m x 0.6m
Design Data
Clear width of the drain = 0.45 m
Clear height of the drain = 0.6 m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.15 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 18 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design
Catchment Area A = 352 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.03 m3/s
Cross section design
Adapted Dimensions
Clear Width = 0.45 m
Height inclusion of Free board = 0.6 m
Manning's Constant N = 0.09 (for drains made of Concrete)
Cross Sectional area of A = 0.27 m2
Wetted Perimeter P = 1.05 m
Radius R = 0.257143 m
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 0.04 m3/s
Provide section of size 0.45 x 0.6 m

Calculations of Loads
SD27

Load from top of the slab = 0 kN/m2


Loads from the walls = 7.17 kN/m2
Loads from bottom slab = 0.09 kN/m2
Total Load = 7.26 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 0.95 kN.m
Mid span moment of bottom slab = 0.55 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 2.38 1.55 kN.m.
Factored moment 0 3.57 2.325 kN.m.

Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
Area of the bar = 78.5
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 120.50 155.50 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 628 628 mm2
spacing required 0 142.8 142.8 mm
spacing provided 0 140 140 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200 mm

Check for shear


ζc 0 0.60 0.38 N/mm2
Actual Shear sress 0 0.61 0.22 N/mm2
SD27

Maximum Shear stress 0 2.8 2.8 N/mm2


Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 5.78 kN/m2
self weight of bottom slab = 1.77 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 7.55 kN/m2
Safe
SD27

0.42 0.31

0.25 0.36
0.5 0.48
SD28

SALEM CITY MUNICIPAL CORPORATION


Structural Design for RCC Drain of Size 0.6m x 0.6m
Design Data
Clear width of the drain = 0.6 m
Clear height of the drain = 0.6 m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.15 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 20 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design
Catchment Area A = 527 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.05 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 0.6 m
Height inclusion of Free board = 0.6 m
Manning's Constant N = 0.09 (for drains made of Concrete)
Cross Sectional area of A = 0.36 m2
Wetted Perimeter P = 1.2 m
Radius R = 0.3 m
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 0.06 m3/s
Provide section of size 0.6 x 0.6 m

Calculations of Loads
SD28

Load from top of the slab = 0 kN/m2


Loads from the walls = 7.17 kN/m2
Loads from bottom slab = 0.09 kN/m2
Total Load = 7.26 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 1.26 kN.m
Mid span moment of bottom slab = 0.73 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 2.8 1.55 kN.m.
Factored moment 0 4.2 2.325 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.5
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 39.65 29.51 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 550 550 mm2
spacing required 0.00 142.73 142.73 mm
spacing provided 0 140 140 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0.00 279.11 209.33 mm
Spacing provided 0 270 200 mm

Check for shear


ζc 0 0.49 0.30 N/mm2
Actual Shear sress 0 0.54 0.22 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
SD28

Check Safe Safe


Check for base pressure
Total load from bottom slab = 5.78 kN/m2
self weight of bottom slab = 2.08 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 7.87 kN/m2
Check safe
SD28

0.37 0.28

0.25 0.36
0.5 0.48
SD29

SALEM CITY MUNICIPAL CORPORATION


Structural Design for RCC Drain of Size 0.8m x 0.8m
Design Data
Clear width of the drain = 0.8 m
Clear height of the drain = 0.8 m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.15 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 18 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design
Catchment Area A = 1083 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.10 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 0.8 m
Height inclusion of Free board = 0.8 m
Manning's Constant N = 0.09 (for drains made of Concrete)
Cross Sectional area of A = 0.64 m2
Wetted Perimeter P = 1.8 m
Radius R = 0.36 m
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 0.13 m3/s
Provide section of size 0.8 x 0.8 m

Calculations of Loads
SD29

Load from top of the slab = 0 kN/m2


Loads from the walls = 5.21 kN/m2
Loads from bottom slab = 0.12 kN/m2
Total Load = 5.33 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 1.68 kN.m
Mid span moment of bottom slab = 0.98 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 3.36 1.96 kN.m.
Factored moment 0 5.04 2.945 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 43.43 33.21 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 628 628 mm2
spacing required 0 125.00 125.00 mm
spacing provided 0 120 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 250 200 mm

Check for shear


ζc 0 0.60 0.38 N/mm2
Actual Shear sress 0 0.48 0.36 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
SD29

Check Safe Safe Safe

Check for base pressure


Total load from bottom slab = 7.71 kN/m2
self weight of bottom slab = 2.50 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 10.21 kN/m2
Check safe
SD29

0.42 0.31

0.25 0.36
0.5 0.48
SD30

SALEM CITY MUNICIPAL CORPORATION


Sectional Design for RCC Drain of Size 1mx 0.8m

Design Data
Clear width of the drain = 1m
Clear height of the drain = 0.8 m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.15 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design Current Pt.


Previous Pt.
Catchment Area A = 1475 m2 1989 578 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.14 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.00 m
Height inclusion of Free board = 0.80 m
Manning's Constant N = 0.08
Cross section of D/C A = 0.80 m2
Wetted Perimeter P = 2.20 m
Radius R = 0.36 m
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 0.18 m3/s
Provide section of size 1 x 0.8 m
SD30

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 5.21 kN/m2
Loads from bottom slab = 72 kN/m2
Total Load = 77.21 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 2.10 kN.m
Mid span moment of bottom slab = 1.22 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 3.92 1.96 kN.m.
Factored moment 0 5.88 2.945 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50 mm2
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 46.91 33.21 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 628 628 mm2
spacing required 0.00 125.00 125.00 mm
spacing provided 0 120 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0.00 279.11 209.33 mm
Spacing provided 0 270 200 mm

Check for shear


ζc 0 0.60 0.38 N/mm2
Actual Shear sress 0 0.53 0.36 N/mm2
SD30

Maximum Shear stress 0 2.8 2.8 N/mm2


Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 7.71 kN/m2
self weight of bottom slab = 2.92 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 10.63 kN/m2
Check safe
SD30

0.42 0.31

0.25 0.36
0.5 0.48
SD31

SALEM CITY MUNICIPAL CORPORATION


Sectional Design for RCC Drain of Size1.2m x 1m
Design Data
Clear width of the drain = 1.2 m
Clear height of the drain = 1m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.15 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design Current Pt.


Previous Pt.
Catchment Area A = 2468 m2 1989 578 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.23 m3/s

Cross Section Design


Adapted Dimensions
Clear Width = 1.20 m
Height inclusion of Free board = 1.00 m
Manning's Constant N = 0.08
Area of cross sectio of A = 1.20 m2
Wetted Perimeter P = 2.80 m
Radius R = 0.43 m
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 0.30 m3/s
Provide section of size 1.2 x 1 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
SD31

Loads from the walls = 6.52 kN/m2


Loads from bottom slab = 0.15 kN/m2
Total Load = 6.67 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 2.52 kN.m
Mid span moment of bottom slab = 1.46 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 4.48 2.38 kN.m.
Factored moment 0 6.72 3.565 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 52.62 50.15 36.54 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 628 628 mm2
spacing required 0.00 125.00 125.00 mm
spacing provided 0 120 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200

Check for shear


ζc 0 0.43 0.38 N/mm2
Actual Shear sress 0 0.41 0.36 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe Safe

Check for base pressure


Total load from bottom slab = 9.64 kN/m2
SD31

self weight of bottom slab = 3.33 kN/m2


live load from top slab = 0 kN/m2
Total Pressure = 12.97 kN/m2
Check safe
SD31

0.42 0.31

0.25 0.36
0.5 0.48
SD32

SALEM CITY MUNICIPAL CORPORATION


Sectional Design for RCC Drain of Size 1.6m x 1.2m
Design Data
Clear width of the drain = 1.6 m
Clear height of the drain = 1.2 m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.15 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 100 kN/m2
Xumax/d = 0.46

Design
Catchment Area A = 4569 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.43 m3/s

Cross Section Design


Adapted Dimensions
Clear Width = 1.60 m
Height inclusion of Free board = 1.20 m
Manning's Constant N = 0.08
Cross Section area of D A = 1.92 m2
Wetted Perimeter P = 3.60 m
Radius R = 0.53 m
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 0.56 m3/s
Provide section of size 1.6 x 1.2 m
SD32

Calculations of Loads
Load from top of the slab = 82 kN/m2
Loads from the walls = 7.82 kN/m2
Loads from bottom slab = 0.18 kN/m2
Total Load = 90.00 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.36 kN.m
Mid span moment of bottom slab = 1.95 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 5.6 2.79 kN.m.
Factored moment 0 8.4 4.185 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 56.07 39.59 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 628 628.53 mm2
spacing required 0.00 125.00 124.89 mm
spacing provided 0 120 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0.00 279.11 209.33 mm
Spacing provided 0 270 200 mm

Check for shear


ζc 0.00 0.52 0.38 N/mm2
Actual Shear sress 0.00 0.48 0.36 N/mm2
SD32

Maximum Shear stress 0 2.8 2.8 N/mm2


Check Safe Safe

Check for base pressure


Total load from bottom slab = 11.57 kN/m2
self weight of bottom slab = 4.17 kN/m2
live load from top slab = 82 kN/m2
Total Pressure = 97.73 kN/m2
Check safe
SD32

0.42 0.31

0.25 0.36
0.5 0.48
SD33

SALEM CITY MUNICIPAL CORPORATION


Sectional Design for RCC Drain - N384-386

Design Data
Clear width of the drain = 3.2 m
Clear height of the drain = 1.5 m
Thickness of walls = 0.25 m
Thickness of bottom slab = 0.25 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 80 kN/m2
Xumax/d = 0.46

Design Current Pt.


Previous Pt.
Catchment Area A = 4569 m2 2567 578 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.43 m3/s
Adapted Dimensions
Clear Width = 3.2 m
Height inclusion of Free board = 1.5 m
Manning's Constant N = 0.09
Cross section area of D A = 4.8 m2
Wetted Perimeter P = 5.8 m
Radius R = 0.83 m
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 1.66 m3/s
Provide section of size 3.2 x 1.5 m

Calculations of Loads
SD33

Load from top of the slab = 0 kN/m2


Loads from the walls = 12.22 kN/m2
Loads from bottom slab = 0.375 kN/m2

Total Load = 12.59 kN/m2


Calculation of moments
Fixed end moment of bottom slab = 6.72 kN.m
Mid span moment of bottom slab = 3.90 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 10.36 3.62 kN.m.
Factored moment 0 15.54 5.425 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 12 mm
area of the bar = 113.04
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 76.26 45.08 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 904.32 904.32 mm2
spacing required 0.00 125.00 125.00 mm
spacing provided 0 120 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200 mm

Check for shear


ζc 0.00 0.99 0.67 N/mm2
Actual Shear sress 0.00 0.49 0.37 N/mm2
SD33

Maximum Shear stress 0 2.8 2.8 N/mm2


Check Safe Safe
Check for base pressure
Total load from bottom slab = 18.08 kN/m2
self weight of bottom slab = 7.71 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 25.78 kN/m2
Check safe
SD33

0.60 0.45

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Drain - N386-389
Design Data
Clear width of the drain = 1.4 m
Clear height of the drain = 1.4 m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 80 kN/m2
Xumax/d = 0.46

Design Current Pt.


Previous Pt.
Catchment Area A = 4168 m2 3145 1023 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.40 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.4 m
Height inclusion of Free board = 1.4 m
Manning's Constant N = 0.09 (for drains made of Concrete)
Cross section area of D A = 1.96
Wetted Perimeter P = 3.8
Radius R = 0.515789
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 0.50 m3/s
Hence the section of size may be 1.4 x 1.4 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 9.12 kN/m2
Loads from bottom slab = 0.28 kN/m2
Total Load = 9.40 kN/m2

Calculation of moments
Fixed end moment of bottom slab = 2.94 kN.m
Mid span moment of bottom slab = 1.71 kN.m
Moment at side walls = 4.32 kN.m
Moment calculated after analysis
Moment Top Slab Bottom Slab Walls
Design moment 0 5.04 3.31 kN.m.
Factored moment 0 7.56 4.96 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 12 mm
area of the bar = 113.04
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 53.19 43.10 mm
Depth provided 0 200 200 mm
Effective depth 0 180 180 mm
Minimum Ast 0 240 240 mm2
Main Ast provided 0 785.3 628.53 mm2
spacing required 0.00 143.94 179.85 mm
spacing provided 0 140 170 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 10 10 mm
Area of the distribution bar 0 78.5 78.5 mm2
Min. reinfocement 0 240 240 mm2
Spacing required 0 327.08 327.08 mm
Spacing provided 300 300 mm

Check for shear


ζc 0.00 0.55 0.38 N/mm2
Actual Shear sress 0.00 0.51 0.37 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe
Check for base pressure
Total load from bottom slab = 13.50 kN/m2
self weight of bottom slab = 3.75 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 17.25 kN/m2
Check safe
0.39 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Drain - N389-393
Design Data
Clear width of the drain = 1.6 m
Clear height of the drain = 1.5 m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 18 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design Data Current Pt.


Previous Pt.
Catchment Area A = 6591 m2 4168 2423 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.63 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.6 m
Height inclusion of Free board = 1.5 m
Manning's Constanty N = 0.09 (for drains made of Concrete)
Cross section area of D A = 2.4
Wetted Perimeter P = 4.2
Radius R = 0.571429
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 0.65 m3/s
Hence the section of size may be 1.6 x 1.5 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 9.77 kN/m2
Loads from bottom slab = 0.3 kN/m2
Total Load = 10.07 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.36 kN.m
Mid span moment of bottom slab = 1.95 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 5.6 3.51 kN.m.
Factored moment 0 8.4 5.27 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 56.07 44.43 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 785.3 628.53 mm2
spacing required 0.00 99.96 124.89 mm
spacing provided 0 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200 mm

Check for shear


ζc 0.00 0.82 0.38 N/mm2
Actual Shear sress 0.00 0.63 0.37 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 14.46 kN/m2
self weight of bottom slab = 4.17 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 18.63 kN/m2
Check safe
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Culvert N393-N394
Design Data
Clear width of the drain = 1.8 m
Clear height of the drain = 1.9 m
Thickness of walls = 0.25 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0.2 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 100 kN/m2
Xumax/d = 0.46
Design Data Current Pt.
Previous Pt.
Catchment Area A = 7704 m2 6591 1113 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.73 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 1.9 m
Manning's Constant N = 0.09 (for drains made of Concrete)
Cross section area of D A = 3.42
Wetted Perimeter P = 5.2
Radius R = 0.657692
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 1.02 m3/s
Hence the section of size may be 1.8 x 1.9 m

Calculations of Loads
Load from top of the slab = 68.2 kN/m2
Loads from the walls = 15.47 kN/m2
Loads from bottom slab = 0.38 kN/m2
Total Load = 84.05 kN/m2

Calculation of moments
Fixed end moment of bottom slab = 3.78 kN.m
Mid span moment of bottom slab = 2.20 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 6.44 6.44 4.75 kN.m.
Factored moment 9.66 9.66 7.13 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 52.62 60.13 51.68 mm
Depth provided 200 150 200 mm
Effective depth 130 130 180 mm
Minimum Ast 180 180 240 mm2
Main Ast provided 706 785.3 628.53 mm2
spacing required 111.19 99.96 124.89 mm
spacing provided 110 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200 mm

Check for shear


ζc 0.76 0.85 0.42 N/mm2
Actual Shear sress 0.62 0.68 0.38 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 22.90 kN/m2
self weight of bottom slab = 4.79 kN/m2
live load from top slab = 68.2 kN/m2
Total Pressure = 95.89 kN/m2
Check safe
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Drain - N394-N423
Design Data
Clear width of the drain = 1.8 m
Clear height of the drain = 1.9 m
Thickness of walls = 0.25 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 18 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 80 kN/m2
Xumax/d = 0.46

Design Current Pt.


Previous Pt.
Catchment Area A = 6591 m2 4168 2423 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.63 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 1.9 m
Manning's Constant N = 0.09 (for drains made of Concrete)
Cross section area of D A = 3.42
Wetted Perimeter P = 5.2
Radius R = 0.657692
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 1.02 m3/s
Hence the section of size may be 1.8 x 1.9 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 15.47 kN/m2
Loads from bottom slab = 0.38 kN/m2
Total Load = 15.85 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.78 kN.m
Mid span moment of bottom slab = 2.20 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 6.44 4.34 kN.m.
Factored moment 0 9.66 6.51 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 60.13 49.38 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 785.3 628.53 mm2
spacing required 0.00 99.96 124.89 mm
spacing provided 0 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200 mm

Check for shear


ζc 0.00 o.72 0.52 N/mm2
Actual Shear sress 0.00 0.65 0.43 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe
Check for base pressure
Total load from bottom slab = 22.90 kN/m2
self weight of bottom slab = 4.79 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 27.69 kN/m2
Check safe
0.30 0.49

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Drain - N424-N431
Design Data
Clear width of the drain = 1.8 m
Clear height of the drain = 1.9 m
Thickness of walls = 0.25 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0.2 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design Current Pt.


Previous Pt.
Catchment Area A = 9913 m2 7704 2209 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.94 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 1.9 m
Manning's Constant N = 0.09 (for drains made of Concrete)
Cross section of D/C A = 3.42
Wetted Perimeter P = 5.2
Radius R = 0.657692
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 1.02 m3/s
Hence the section of size may be 1.8 x 1.9 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 15.47 kN/m2
Loads from bottom slab = 0.38 kN/m2
Total Load = 15.85 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.78 kN.m
Mid span moment of bottom slab = 2.20 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 6.44 4.75 kN.m.
Factored moment 0 9.66 7.13 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 60.13 51.68 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 785.3 628.53 mm2
spacing required 0.00 99.96 124.89 mm
spacing provided 0 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200

Check for shear


ζc 0.00 o.72 0.52 N/mm2
Actual Shear sress 0.00 0.65 0.43 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe
Check for base pressure
Total load from bottom slab = 22.90 kN/m2
self weight of bottom slab = 4.79 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 27.69 kN/m2
Check safe
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Culvert - N431-N432, N434-N435, N436-437, N438-N439
Design Data
Clear width of the drain = 1.8 m
Clear height of the drain = 1.9 m
Thickness of walls = 0.25 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0.2 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 100 kN/m2
Xumax/d = 0.46

Design Current Pt.


Previous Pt.
Catchment Area A = 9913 m2 7704 2209 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.94 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 1.9 m
Manning's Constant N = 0.09 (for drains made of Concrete)
Cross section of D/C A = 3.42
Wetted Perimeter P = 5.2
Radius R = 0.657692
Dishcarge through Drain Q = (1/N)xAxR2/3xS1/2
= 1.02 m3/s
Hence the section of size may be 1.8 x 1.9 m

Calculations of Loads
Load from top of the slab = 68.2 kN/m2
Loads from the walls = 15.47 kN/m2
Loads from bottom slab = 0.38 kN/m2
Total Load = 84.05 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.78 kN.m
Mid span moment of bottom slab = 2.20 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 6.44 6.44 4.75 kN.m.
Factored moment 9.66 9.66 7.13 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 52.62 60.13 51.68 mm
Depth provided 200 150 200 mm
Effective depth 130 130 180 mm
Minimum Ast 180 180 240 mm2
Main Ast provided 706 785.3 628.53 mm2
spacing required 111.19 99.96 124.89 mm
spacing provided 110 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 8 8 8 mm
Area of the distribution bar 50.24 50.24 50.24 mm2
Min. reinfocement 180 180 240 mm2
Spacing required 279.11 279.11 209.33 mm
Spacing provided 250 250 200 mm

Check for shear


ζc 0.68 0.72 0.52 N/mm2
Actual Shear sress 0.62 0.65 0.43 N/mm2
Maximum Shear stress 2.8 2.8 2.8 N/mm2
Check Safe Safe
Check for base pressure
Total load from bottom slab = 22.90 kN/m2
self weight of bottom slab = 4.79 kN/m2
live load from top slab = 68.2 kN/m2
Total Pressure = 95.89 kN/m2
Check safe
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Drain - N433-N434, N435-436, N437-N438
Design Data
Clear width of the drain = 1.8 m
Clear height of the drain = 1.9 m
Thickness of walls = 0.25 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 17 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design Current Pt.


Previous Pt.
Catchment Area A = 9913 m2 7704 2209 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.94 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 1.9 m
Manning's Constant N = 0.09 (for drains made of Concrete)
Cross section area of D A = 3.42
Wetted Perimeter P = 5.2
Radius R = 0.658
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 1.02 m3/s
Hence the section of size may be 1.8 x 1.9 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 15.47 kN/m2
Loads from bottom slab = 0.38 kN/m2
Total Load = 15.85 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.78 kN.m
Mid span moment of bottom slab = 2.20 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 6.44 4.34 kN.m.
Factored moment 0 9.66 6.51 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 60.13 49.38 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 785.3 628.53 mm2
spacing required 0.00 99.96 124.89 mm
spacing provided 0 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 250 200

Check for shear


ζc 0.00 0.72 0.52 N/mm2
Actual Shear sress 0.00 0.65 0.43 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe
Check for base pressure
Total load from bottom slab = 22.90 kN/m2
self weight of bottom slab = 4.79 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 27.69 kN/m2
Check safe
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Drain - N439-440, N441-N442, N443-N444
Design Data
Clear width of the drain = 1.8 m
Clear height of the drain = 2.1 m
Thickness of bottom slab = 0.25 m
Thickness of top slab = 0m
Length considered for the design = 170 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 80 kN/m2
Xumax/d = 0.46

Design Data Current Pt.


Previous Pt.
Catchment Area A = 9913 m2
7704 2209 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.94 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 2.1 m
Manning's Constanty N = 0.09 (for drains made of Concrete)
Area of cross sectio of A = 3.78
Wetted Perimeter P = 5.6
Radius R = 0.675
Dishcarge through Drain Q = (1/N)xAxR2/3xS1/2
= 1.14 m3/s
Hence the section of size may be 1.8 x 2.1 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 17.10 kN/m2
Loads from bottom slab = 0.525 kN/m2
Total Load = 17.63 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.78 kN.m
Mid span moment of bottom slab = 2.20 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab ottom Slab Walls
Design moment 0 6.44 4.86 kN.m.
Factored moment 0 9.66 7.285 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 60.13 52.23 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 785.3 628.53 mm2
spacing required 0.00 99.96 124.89 mm
spacing provided 0 90 120 mm
Distribution reinforcement Top Slab ottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 250 200

Check for shear


ζc 0.00 0.72 0.52 N/mm2
Actual Shear sress 0.00 0.65 0.43 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe
Check for base pressure
Total load from bottom slab = 25.31 kN/m2
self weight of bottom slab = 4.79 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 30.10 kN/m2
Check safe
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Drain - N440-N441, N442-N443
Design Data
Clear width of the drain = 1.8 m
Clear height of the drain = 2.1 m
Thickness of walls = 0.25 m
Thickness of bottom slab = 0.25 m
Thickness of top slab = 0.25 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 120 kN/m2
Xumax/d = 0.46

Design Data Current Pt.


Previous Pt.
Catchment Area A = 9913 m2
7704 2209 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.94 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 2.1 m
Manning's Constant N = 0.09 (for drains made of Concrete)
Cross section area of D A = 3.78
Wetted Perimeter P = 5.6
Radius R = 0.675
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 1.14 m3/s
Hence the section of size may be 1.8 x 2.1 m

Calculations of Loads
Load from top of the slab = 71.42 kN/m2
Loads from the walls = 17.10 kN/m2
Loads from bottom slab = 0.525 kN/m2
Total Load = 89.05 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.78 kN.m
Mid span moment of bottom slab = 2.20 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab ottom Slab Walls
Design moment 8.05 6.44 5.37 kN.m.
Factored moment 12.075 9.66 8.06 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 12 mm
area of the bar = 113.04
Xumax/d = 0.46
R = 2.67
Minimum depth required 67.22 60.13 54.94 mm
Depth provided 250 250 250 mm
Effective depth 230 230 230 mm
Minimum Ast 300 300 300 mm2
Main Ast provided 785.3 785.3 628.53 mm2
spacing required 143.94 143.94 179.85 mm
spacing provided 140 140 170 mm
Distribution reinforcement Top Slab ottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 300 300 mm2
Spacing required 0 167.47 167.47 mm
Spacing provided 160 160

Check for shear


ζc 0.68 0.72 0.52 N/mm2
Actual Shear sress 0.48 0.65 0.46 N/mm2
Maximum Shear stress 2.8 2.8 2.8 N/mm2
Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 25.31 kN/m2
self weight of bottom slab = 4.79 kN/m2
live load from top slab = 71.42 kN/m2
Total Pressure = 101.52 kN/m2
Check safe
0.31 0.25

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Drain - N444-N445
Design Data
Clear width of the drain = 1.9 m
Clear height of the drain = 2.4 m
Thickness of walls = 0.3 m
Thickness of bottom slab = 0.3 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design Data Current Pt.


Previous Pt.
Catchment Area A = 10498 m2 9913 585
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 1.00 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 2.4 m
Manning's Constant N = 0.1 (for drains made of Concrete)
Cross section area of D A = 4.32
Wetted Perimeter P = 6.2
Radius R = 0.696774
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 1.20 m3/s
Hence the section of size may be 1.8 x 2.4 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 23.45 kN/m2
Loads from bottom slab = 0.72 kN/m2
Total Load = 24.17 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.99 kN.m
Mid span moment of bottom slab = 2.32 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 7 5.58 kN.m.
Factored moment 0 10.5 8.37 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 12 mm
area of the bar = 113.04
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 62.69 55.99 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 785.3 628.53 mm2
spacing required 0.00 143.94 179.85 mm
spacing provided 0 140 170 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200 mm

Check for shear


ζc 0.68 0.72 0.52 N/mm2
Actual Shear sress 0.48 0.65 0.46 N/mm2
Maximum Shear stress 2.8 2.8 2.8 N/mm2
Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 34.70 kN/m2
self weight of bottom slab = 5.21 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 39.91 kN/m2
Check safe
0.29 0.43

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Drain - N445 - Out fall
Design Data
Clear width of the drain = 1.9 m
Clear height of the drain = 2.9 m
Thickness of walls = 0.3 m
Thickness of bottom slab = 0.3 m
Thickness of top slab = 0.15 m
Length considered for the design = 170 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 80 kN/m2
Xumax/d = 0.46
Design Data Current Pt.
Previous Pt.
Catchment Area A = 10498 m2 9913 585 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 1.00 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 2.9 m
Manning's Constanty N = 0.1 (for drains made of Concrete)
Area of cross sectio of A = 5.22
Wetted Perimeter P = 7.2
Radius R = 0.725
Dishcarge through Drain Q = (1/N)xAxR2/3xS1/2
= 1.49 m3/s
Hence the section of size may be 1.8 x 2.9 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 28.34 kN/m2
Loads from bottom slab = 0.87 kN/m2
Total Load = 29.21 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.99 kN.m
Mid span moment of bottom slab = 2.32 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 5.25 7 6.92 kN.m.
Factored moment 7.875 10.5 10.385 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 12 mm
area of the bar = 113.04
Xumax/d = 0.46
R = 2.67
Minimum depth required 52.62 62.69 62.37 mm
Depth provided 150 150 200 mm
Effective depth 130 130 180 mm
Minimum Ast 180 180 240 mm2
Main Ast provided 706 785.3 628.53 mm2
spacing required 160.11 143.94 179.85 mm
spacing provided 160 140 170 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200

Check for shear


ζc 0.68 0.72 0.52 N/mm2
Actual Shear sress 0.48 0.65 0.49 N/mm2
Maximum Shear stress 2.8 2.8 2.8 N/mm2
Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 41.93 kN/m2
self weight of bottom slab = 5.21 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 47.14 kN/m2
Check safe
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Culvert N1141-N1142
Design Data
Clear width of the drain = 1.4 m
Clear height of the drain = 2.4 m
Thickness of walls = 0.3 m
Thickness of bottom slab = 0.25 m
Thickness of top slab = 0.25 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 120 kN/m2
Xumax/d = 0.46

Design
Catchment Area A = 7604 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.72 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.4 m
Height inclusion of Free board = 2.4 m
Manning's Constant N = 0.1 (for drains made of Concrete)
Cross section area of D A = 3.36
Wetted Perimeter P = 5.8
Radius R = 0.57931
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 0.83 m3/s
Hence the section of size may be 1.4 x 2.4 m

Calculations of Loads
Load from top of the slab = 65.62 kN/m2
Loads from the walls = 23.45 kN/m2
Loads from bottom slab = 0.6 kN/m2
Total Load = 89.67 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 2.94 kN.m
Mid span moment of bottom slab = 1.71 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 7 5.6 5.99 kN.m.
Factored moment 10.5 8.4 8.99 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 12 mm
area of the bar = 113.04
Xumax/d = 0.46
R = 2.67
Minimum depth required 52.62 56.07 58.03 mm
Depth provided 250 150 200 mm
Effective depth 130 130 180 mm
Minimum Ast 180 180 240 mm2
Main Ast provided 706 785.3 628.53 mm2
spacing required 160.11 143.94 179.85 mm
spacing provided 160 140 170 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 8 8 8 mm
Area of the distribution bar 50.24 50.24 50.24 mm2
Min. reinfocement 180 180 240 mm2
Spacing required 279.11 279.11 209.33 mm
Spacing provided 270 270 200 mm

Check for shear


ζc 0.52 0.54 0.52 N/mm2
Actual Shear sress 0.48 0.49 0.49 N/mm2
Maximum Shear stress 2.8 2.8 2.8 N/mm2
Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 34.70 kN/m2
self weight of bottom slab = 4.17 kN/m2
live load from top slab = 65.62 kN/m2
Total Pressure = 104.49 kN/m2
Check safe
8946.438
0.214715
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Culvert N1142-N1143
Design Data
Clear width of the drain = 1.8 m
Clear height of the drain = 2.4 m
Thickness of walls = 0.3 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0.2 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design Data
Catchment Area A = 11058 m2 p b
Rainfall Intensity I = 142.4 mm 3454 7604
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 1.05 m3/s
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 2.4 m
Manning's Constanty N = 0.1 (for drains made of Concrete)
Area of cross sectio of Dr A = 4.32
Wetted Perimeter P = 6.2
Radius R = 0.69677
Dishcarge through Drain/ Q = (1/N)xAxR2/3xS1/2
= 1.20 m3/s
Hence the section of size may be 1.8 x 2.4 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 23.45 kN/m2
Loads from bottom slab = 0.48 kN/m2
Total Load = 23.93 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.78 kN.m
Mid span moment of bottom slab = 2.20 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 6.72 6.72 5.79 kN.m.
Factored moment 10.08 10.08 8.68 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 12 mm
area of the bar = 113.04
Xumax/d = 0.46
R = 2.67
Minimum depth required 52.62 61.42 57.02 mm
Depth provided 200 150 200 mm
Effective depth 130 130 180 mm
Minimum Ast 180 180 240 mm2
Main Ast provided 706 785.3 628.53 mm2
spacing required 160.11 143.94 179.85 mm
spacing provided 110 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 8 8 8 mm
Area of the distribution bar 50.24 50.24 50.24 mm2
Min. reinfocement 180 180 240 mm2
Spacing required 279.11 279.11 209.33 mm
Spacing provided 250 250 200 mm

Check for shear


ζc 0.55 0.58 0.42 N/mm2
Actual Shear sress 0.43 0.45 0.38 N/mm2
Maximum Shear stress 2.8 2.8 2.8 N/mm2
Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 34.70 kN/m2
self weight of bottom slab = 5.00 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 39.70 kN/m2
Check safe
13009.1
0.31222
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Culvert N1142-N1143
Design Data
Clear width of the drain = 1.8 m
Clear height of the drain = 2.4 m
Thickness of walls = 0.3 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0.2 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 120 kN/m2
Xumax/d = 0.46
Design Data
Catchment Area A = 11058 m2 p
Rainfall Intensity I = 142.4 mm 3454
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 1.05 m3/s
Cross Section Design
Adapted Dimensions
Clear Width = 1.8 m
Height inclusion of Free board = 2.4 m
Manning's Constant N = 0.1 (for drains made of Concrete)
Cross section area of D/C A = 4.32
Wetted Perimeter P = 6.2
Radius R = 0.69677
Dishcarge through D/C Q = (1/N)xAxR2/3xS1/2
= 1.20 m3/s
Hence the section of size may be pro 1.8 x 2.4 m

Calculations of Loads
Load from top of the slab = 72.2 kN/m2
Loads from the walls = 23.45 kN/m2
Loads from bottom slab = 0.48 kN/m2
Total Load = 96.13 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.78 kN.m
Mid span moment of bottom slab = 2.20 kN.m
Moment at side walls = 4.32 kN.m
Moment calculated after analysis
Moment Top Slab Bottom Slab Walls
Design moment 6.72 6.72 5.79 kN.m.
Factored moment 10.08 10.08 8.68 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 52.62 61.42 57.02 mm
Depth provided 200 150 200 mm
Effective depth 130 130 180 mm
Minimum Ast 180 180 240 mm2
Main Ast provided 706 785.3 628.53 mm2
spacing required 111.19 99.96 124.89 mm
spacing provided 110 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 8 8 8 mm
Area of the distribution bar 50.24 50.24 50.24 mm2
Min. reinfocement 180 180 240 mm2
Spacing required 279.11 279.11 209.33 mm
Spacing provided 270 270 200 mm

Check for shear


ζc 0.55 0.58 0.42 N/mm2
Actual Shear sress 0.43 0.45 0.38 N/mm2
Maximum Shear stress 2.8 2.8 2.8 N/mm2
Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 34.70 kN/m2
self weight of bottom slab = 5.00 kN/m2
live load from top slab = 72.2 kN/m2
Total Pressure = 111.90 kN/m2
Check safe
b
7604

13009.1
0.31222

of Concrete)
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Culvert N 1143-N1147
Design Data
Clear width of the drain = 1.9 m
Clear height of the drain = 2.1 m
Thickness of walls = 0.3 m
Thickness of bottom slab = 0.25 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 120 kN/m2
Xumax/d = 0.46

Design
Catchment Area A = 10245 m2 p
Rainfall Intensity I = 142.4 mm 2641
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.97 m3/s
Adapted Dimensions
Clear Width = 1.9 m
Height inclusion of Free board = 2.1 m
Manning's Constanty N = 0.1 (for drains made of Concrete)
Area of cross sectio of Drain A = 3.99
Wetted Perimeter P = 5.7
Radius R = 0.7
Dishcarge through Drain/Culv Q = (1/N)xAxR2/3xS1/2
= 1.11 m3/s
Provide section of size 1.9 x 2.1 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 20.52 kN/m2
Loads from bottom slab = 0.525 kN/m2
Total Load = 21.05 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 3.99 kN.m
Mid span moment of bottom slab = 2.32 kN.m
Moment at side walls = 4.32 kN.m
Moment calculated after analysis
Moment Top Slab Bottom Slab Walls
Design moment 0 7 4.86 kN.m.
Factored moment 0 10.5 7.285 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 52.62 62.69 52.23 mm
Depth provided 0 150 200 mm
Effective depth 130 130 180 mm
Minimum Ast 180 180 240 mm2
Main Ast provided 706 785.3 628.53 mm2
spacing required 111.19 99.96 124.89 mm
spacing provided 110 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200

Check for shear


ζc 0.55 0.58 0.42 N/mm2
Actual Shear sress 0.43 0.45 0.35 N/mm2
Maximum Shear stress 2.8 2.8 2.8 N/mm2
Check Safe Safe Safe
Check for base pressure
Total load from bottom slab = 30.37 kN/m2
self weight of bottom slab = 5.21 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 35.57 kN/m2
Check safe
b
7604

12052.4
0.28926

of Concrete)
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Culvert N 1147-N1220
Design Data
Clear width of the drain = 2m
Clear height of the drain = 2.1 m
Thickness of walls = 0.3 m
Thickness of bottom slab = 0.25 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46
Design
Catchment Area A = 11030 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 1.05 m3/s
Adapted Dimensions
Clear Width = 2m
Height inclusion of Free board = 2.1 m
Manning's Constanty N = 0.1 (for drains made of Concrete)
Area of cross sectio of A = 4.2
Wetted Perimeter P = 5.8
Radius R = 0.72414
Dishcarge through Drain Q = (1/N)xAxR2/3xS1/2
= 1.20 m3/s
Hence the section of size may be 2 x 2.1 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 20.52 kN/m2
Loads from bottom slab = 0.525 kN/m2
Total Load = 21.05 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 4.20 kN.m
Mid span moment of bottom slab = 2.44 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 7.28 4.86 kN.m.
Factored moment 0 10.92 7.285 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 12 mm
area of the bar = 113.04
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 63.93 52.23 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 785.3 628.53 mm2
spacing required 0.00 143.94 179.85 mm
spacing provided 0 140 170 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0.00 279.11 209.33 mm
Spacing provided 0 250 200 mm

Check for shear


ζc 0.00 0.60 0.42 N/mm2
Actual Shear sress 0.00 0.52 0.40 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe

Check for base pressure


Total load from bottom slab = 30.37 kN/m2
self weight of bottom slab = 5.42 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 35.78 kN/m2
Check safe
p b
3426 7604

12976.8
0.31144
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Culvert N 1208 - N1213
Design Data
Clear width of the drain = 0.6 m
Clear height of the drain = 1m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0.15 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design
Catchment Area A = 913 m2 p b
Rainfall Intensity I = 142.4 mm 913
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.09 m3/s
Adapted Dimensions
Clear Width = 0.6 m
Height inclusion of Free board = 1m
Manning's Constanty N = 0.09 (for drains made of Concrete)
Area of cross sectio o A = 0.6
Wetted Perimeter P = 2.2
Radius R = 0.27
Dishcarge through Dra Q = (1/N)xAxR2/3xS1/2
= 0.10 m3/s
Hence the section of size may 0.6 x 1 m
Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 6.52 kN/m2
Loads from bottom slab = 0.2 kN/m2
Total Load = 6.72 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 1.26 kN.m
Mid span moment of bottom slab = 0.73 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 0 2.8 2.79 kN.m.
Factored moment 0 4.2 4.185 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 39.65 39.59 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 785.3 628.53 mm2
spacing required 0.00 99.96 124.89 mm
spacing provided 0 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200

Check for shear


ζc 0.00 0.42 0.42 N/mm2
Actual Shear sress 0.00 0.38 0.40 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe
Check for base pressure
Total load from bottom slab = 9.64 kN/m2
self weight of bottom slab = 2.08 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 11.72 kN/m2
Check safe
1074.23
0.02578
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Culvert of size 0.6m x 1m
Design Data
Clear width of the drain = 0.6 m
Clear height of the drain = 1m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0.15 m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 100 kN/m2
Xumax/d = 0.46

Design
Catchment Area A = 913 m2 p b
Rainfall Intensity I = 142.4 mm 913
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.09 m3/s
Adapted Dimensions
Clear Width = 0.6 m
Height inclusion of Free board = 1m
Manning's Constanty N = 0.09 (for drains made of Concrete)
Area of cross sectio of D A = 0.6
Wetted Perimeter P = 2.2
Radius R = 0.27273
Dishcarge through Drain/ Q = (1/N)xAxR2/3xS1/2
= 0.10 m3/s
Hence the section of size may be 0.6 x 1 m

Calculations of Loads
Load from top of the slab = 65.25 kN/m2
Loads from the walls = 6.52 kN/m2
Loads from bottom slab = 0.2 kN/m2
Total Load = 71.97 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 1.26 kN.m
Mid span moment of bottom slab = 0.73 kN.m
Moment at side walls = 4.32 kN.m

Moment calculated after analysis


Moment Top Slab Bottom Slab Walls
Design moment 2.1 2.8 2.79 kN.m.
Factored moment 3.15 4.2 4.185 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 52.62 39.65 39.59 mm
Depth provided 150 150 200 mm
Effective depth 130 130 180 mm
Minimum Ast 180 180 240 mm2
Main Ast provided 706 785.3 628.53 mm2
spacing required 111.19 99.96 124.89 mm
spacing provided 110 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 8 8 8 mm
Area of the distribution bar 50.24 50.24 50.24 mm2
Min. reinfocement 180 180 240 mm2
Spacing required 279.11 279.11 209.33 mm
Spacing provided 270 270 200 mm

Check for shear


ζc 0.00 0.42 0.42 N/mm2
Actual Shear sress 0.00 0.38 0.40 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe
Check for base pressure
Total load from bottom slab = 9.64 kN/m2
self weight of bottom slab = 2.08 kN/m2
live load from top slab = 65.25 kN/m2
Total Pressure = 76.97 kN/m2
Check safe
1074.23
0.02578
0.52 0.31

0.25 0.36
0.5 0.48
SALEM CITY MUNICIPAL CORPORATION
Sectional Design for RCC Culvert of size 0.8m x 1m
Design Data
Clear width of the drain = 0.8 m
Clear height of the drain = 1m
Thickness of walls = 0.2 m
Thickness of bottom slab = 0.2 m
Thickness of top slab = 0m
Unit weight of the Concrete = 25 kN/m3
Unit weight of soil γ = 19 kN/m3
Angle of repose φ = 30 degrees
Earth pressure co-efficient ka = 0.33
Density of water = 10 kN/m3
Grade of Concrete fck = 20 N/mm2
Grade of Steel fy = 500 N/mm2
Safe bearing Capacity of the Soil = 50 kN/m2
Xumax/d = 0.46

Design
Catchment Area A = 1392 m2
Rainfall Intensity I = 142.4 mm
Run off Coefficient C = 0.1 (Coarse Soil)
Calculation of Discharge
Q = 0.278xCxIxA
= 0.13 m3/s
Adapted Dimensions
Clear Width = 0.8 m
Height inclusion of Free board = 1m
Manning's Constanty N = 0.09 (for drains made of Concrete)
Area of cross sectio of A = 0.8 m2
Wetted Perimeter P = 2.4 m
Radius R = 0.33333 m
Dishcarge through Drain Q = (1/N)xAxR2/3xS1/2
= 0.15 m3/s
Hence the section of size may be 0.8 x 1 m

Calculations of Loads
Load from top of the slab = 0 kN/m2
Loads from the walls = 6.52 kN/m2
Loads from bottom slab = 0.2 kN/m2
Total Load = 6.72 kN/m2
Calculation of moments
Fixed end moment of bottom slab = 1.68 kN.m
Mid span moment of bottom slab = 0.98 kN.m
Moment at side walls = 4.32 kN.m
Moment calculated after analysis
Moment Top Slab Bottom Slab Walls
Design moment 0 3.36 2.48 kN.m.
Factored moment 0 5.04 3.72 kN.m.
Design of reinforcements
Considering the limiting moment
diameter of the bar = 10 mm
area of the bar = 78.50
Xumax/d = 0.46
R = 2.67
Minimum depth required 0 43.43 37.33 mm
Depth provided 0 150 200 mm
Effective depth 0 130 180 mm
Minimum Ast 0 180 240 mm2
Main Ast provided 0 785.3 628.53 mm2
spacing required 0.00 99.96 124.89 mm
spacing provided 0 90 120 mm
Distribution reinforcement Top Slab Bottom Slab Walls
Dia of the distribution bar 0 8 8 mm
Area of the distribution bar 0 50.24 50.24 mm2
Min. reinfocement 0 180 240 mm2
Spacing required 0 279.11 209.33 mm
Spacing provided 270 200

Check for shear


ζc 0.00 0.42 0.42 N/mm2
Actual Shear sress 0.00 0.38 0.40 N/mm2
Maximum Shear stress 0 2.8 2.8 N/mm2
Check Safe Safe

Check for base pressure


Total load from bottom slab = 9.64 kN/m2
self weight of bottom slab = 2.50 kN/m2
live load from top slab = 0 kN/m2
Total Pressure = 12.14 kN/m2
Check safe
1637.33
0.0393
0.52 0.31

0.25 0.36
0.5 0.48