Professional Documents
Culture Documents
Reaktor
̇
𝑃𝑟𝑒𝑎𝑘𝑡𝑜𝑟 = 𝑚̇ (ℎ1 − ℎ3 )
𝑘𝑔 𝑘𝑗 𝑘𝑗
= 19643,87 ( 1482,33 − 1290,38 )
𝑠 𝑘𝑔 𝑘𝑔
𝑘𝑔 𝑘𝑗
= 19643,87 (191,95 )
𝑠 𝑘𝑔
𝑘𝑗 1 𝑚𝑤
= 3770640,8465 𝑥
𝑠 𝑘𝑗
1000 𝑠
= 3770,6484 𝑚𝑤
𝑇0
𝐸𝑖𝑛 = [1 − (𝑇 ̇
)] 𝑥 𝑃𝑟𝑒𝑎𝑘𝑡𝑜𝑟
𝑟𝑒𝑎𝑘𝑡𝑜𝑟
293 𝐾
= [1 − ( )] 𝑥 3770,64 𝑚𝑤
1073 𝐾
= [1 − 0,27772 ] 𝑥 3770,64 𝑚𝑤
= 2723, 435 𝑚𝑤
𝐸𝑜𝑢𝑡 = 𝐸1 − 𝐸3
= 8883,1583 𝑚𝑤 − 7056,0034 𝑚𝑤
= 1872,1549 𝑚𝑤
= 2723,435 𝑚𝑤 − 1827,1549 𝑚𝑤
= 896,2771 𝑚𝑤
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
1827,1549 𝑚𝑤
= 𝑥 100%
2723,435 𝑚𝑤
= 67,09%
Steam Generator
𝐸𝑖𝑛 = 𝐸1 − 𝐸2
= 8883,1583 𝑚𝑤 − 7032,4230 𝑚𝑤
= 1850,7353 𝑚𝑤
𝐸𝑜𝑢𝑡 = 𝐸4 − 𝐸32
= 2150,7462 𝑚𝑤 − 413,13372 𝑚𝑤
= 1737,61248 𝑚𝑤
𝐸𝑙𝑜𝑠𝑠 = 𝐸𝑖𝑛 − 𝐸𝑜𝑢𝑡
= 1850,7353 𝑚𝑤 − 1737,61248 𝑚𝑤
= 113,12282 𝑚𝑤
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
1737,61248 𝑚𝑤
= 𝑥 100%
1850,7353 𝑚𝑤
= 93,88 %
= 1332,9742 𝑚𝑤
𝐸𝑜𝑢𝑡 = 𝐸7 + 𝐸8 + 𝐸13
= 32,0995 𝑚𝑤 + 1218,8703 𝑚𝑤 + 78,85 𝑚𝑤
= 1329,8198 𝑚𝑤
𝐸𝑙𝑜𝑠𝑠 = 𝐸𝑖𝑛 − 𝐸𝑜𝑢𝑡
= 1332, 9742 𝑚𝑤 − 1329,8198 𝑚𝑤
= 3,1544 𝑚𝑤
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
1329,8198 𝑚𝑤
= 𝑥 100%
1332,9742 𝑚𝑤
= 99,76 %
Reheater
𝐸𝑖𝑛 = 𝐸9 − 𝐸10
= 129,7688 𝑚𝑤 − 39,0409 𝑚𝑤
= 90,7279 𝑚𝑤
𝐸𝑜𝑢𝑡 = 𝐸11 − 𝐸8
= 1286,7821 𝑚𝑤 − 1218,8703 𝑚𝑤
= 67,9118 𝑚𝑤
𝐸𝑙𝑜𝑠𝑠 = 𝐸𝑖𝑛 − 𝐸𝑜𝑢𝑡
= 90,7279 𝑚𝑤 − 67,9118 𝑚𝑤
= 22,8161 𝑚𝑤
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
67,9118 𝑚𝑤
= 𝑥 100%
90,7279 𝑚𝑤
= 74,85 %
Condenser
16,2967 𝑚𝑤
= 𝑥 100%
122,136 𝑚𝑤
= 13,34 %
High Pressure Turbine
𝐸𝑖𝑛 = 𝐸5 − 𝐸12 − 𝐸6
= 2016,5961 𝑚𝑤 − 137,702 𝑚𝑤 − 1332,9742 𝑚𝑤
= 545,9198 𝑚𝑤
𝐸𝑜𝑢𝑡 = 𝑊̇𝐻𝑃𝑇
= 𝑚̇5 ℎ5 − (𝑚̇6 ℎ6 + 𝑚̇12 ℎ12 )
kg 𝑘𝑗 𝑘𝑔 𝑘𝑗
= 1943,04 𝑥 2770,66 𝑘𝑔 − (1781,56 𝑥 2519,75 𝑘𝑔 +
s 𝑠
𝑘𝑔 𝑘𝑗
161,49 𝑥 2602,49 𝑘𝑔
𝑠
= 474,1413 𝑚𝑤
474,1413 𝑚𝑤
= 𝑥 100%
545,9198 𝑚𝑤
= 86,85 %
= 4238,9969 𝑚𝑤
− (185,9633𝑚𝑤 + 221,3082 𝑚𝑤 + 265,3156
+ 70,0968 𝑚𝑤 + 2606,352 𝑚𝑤)
= 889,9609 𝑚𝑤
889,9609 𝑚𝑤
= 𝑥 100%
1013,6617 𝑚𝑤
= 87,80 %
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
0,19 𝑚𝑤
= 𝑥 100%
0,3939 𝑚𝑤
= 48,23 %
1,1242 𝑚𝑤
= 𝑥 100%
3,2604 𝑚𝑤
= 34,48 %
29,7691 𝑚𝑤
= 𝑥 100%
42,277 𝑚𝑤
= 70,41 %
186,4070 𝑚𝑤
= 𝑥 100%
190,9139 𝑚𝑤
= 97,63 %
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
84,516 𝑚𝑤
= 𝑥 100%
89,2606 𝑚𝑤
= 94,68 %
114,8083 𝑚𝑤
= 𝑥 100%
124,6 𝑚𝑤
= 92,14 %
Pump 1
𝐸𝑖𝑛 = 𝑊̇𝑝𝑢𝑚𝑝,1
= 𝑚̇20 (ℎ20 − ℎ19 )
𝑘𝑔 𝑘𝑗 𝑘𝑗
= 1306,39 (154,99 − 153,28 )
𝑠 𝑘𝑔 𝑘𝑔
= 2,2339 𝑚𝑤
𝐸𝑜𝑢𝑡 = 𝐸20 − 𝐸19
= 3,084 𝑚𝑤 − 1,161 𝑚𝑤
= 1,923 𝑚𝑤
𝐸𝑙𝑜𝑠𝑠 = 𝐸𝑖𝑛 − 𝐸𝑜𝑢𝑡
= 2,2339 𝑚𝑤 − 1,923 𝑚𝑤
= 0,3109 𝑚𝑤
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
1,923 𝑚𝑤
= 𝑥 100%
2,2339 𝑚𝑤
= 86,08 %
Pump 2
𝐸𝑖𝑛 = 𝑊̇𝑝𝑢𝑚𝑝,2
= 𝑚̇43 (ℎ36 − ℎ43 )
𝑘𝑔 𝑘𝑗 𝑘𝑗
= 83,36 (528,79 − 528,14 )
𝑠 𝑘𝑔 𝑘𝑔
= 0,05418 𝑚𝑤
𝐸𝑜𝑢𝑡 = 𝐸36 − 𝐸43
= 4,9604 𝑚𝑤 − 4,931094 𝑚𝑤
= 0,0294 𝑚𝑤
𝐸𝑙𝑜𝑠𝑠 = 𝐸𝑖𝑛 − 𝐸𝑜𝑢𝑡
= 0,05418 𝑚𝑤 − 0,0294 𝑚𝑤
= 0,024784 𝑚𝑤
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
0,0294 𝑚𝑤
= 𝑥 100%
0,05418 𝑚𝑤
= 45,74 %
Pump 2
𝐸𝑖𝑛 = 𝑊̇𝑝𝑢𝑚𝑝,2
= 𝑚̇43 (ℎ36 − ℎ43 )
𝑘𝑔 𝑘𝑗 𝑘𝑗
= 83,36 (528,79 − 528,14 )
𝑠 𝑘𝑔 𝑘𝑔
= 0,05418 𝑚𝑤
𝐸𝑜𝑢𝑡 = 𝐸36 − 𝐸43
= 4,9604 𝑚𝑤 − 4,931094 𝑚𝑤
= 0,0293 𝑚𝑤
𝐸𝑙𝑜𝑠𝑠 = 𝐸𝑖𝑛 − 𝐸𝑜𝑢𝑡
= 0,05418 𝑚𝑤 − 0,0293 𝑚𝑤
= 0,02488 𝑚𝑤
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
0,0293 𝑚𝑤
= 𝑥 100%
0,05418 𝑚𝑤
= 54,07 %
Pump 3
𝐸𝑖𝑛 = 𝑊̇𝑝𝑢𝑚𝑝,3
= 𝑚̇29 (ℎ29 − ℎ28 )
𝑘𝑔 𝑘𝑗 𝑘𝑗
= 2069,35 (649,60 − 639,23 )
𝑠 𝑘𝑔 𝑘𝑔
= 21,4591 𝑚𝑤
𝐸𝑜𝑢𝑡 = 𝐸29 − 𝐸28
= 204,787 𝑚𝑤 − 186,41 𝑚𝑤
= 18,3758 𝑚𝑤
𝐸𝑙𝑜𝑠𝑠 = 𝐸𝑖𝑛 − 𝐸𝑜𝑢𝑡
= 21,4591 𝑚𝑤 − 18,3758 𝑚𝑤
= 3,0832 𝑚𝑤
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
18,3758 𝑚𝑤
= 𝑥 100%
21,4591 𝑚𝑤
= 85,63 %
Pump 4
𝐸𝑖𝑛 = 𝑊̇𝑝𝑢𝑚𝑝,4
= 𝑚̇3 (ℎ3 − ℎ2 )
𝑘𝑔 𝑘𝑗 𝑘𝑗
= 19643,87 (1290,38 − 1289,18 )
𝑠 𝑘𝑔 𝑘𝑔
= 23,5726 𝑚𝑤
𝐸𝑜𝑢𝑡 = 𝐸3 − 𝐸2
= 7054,8248 𝑚𝑤 − 7032,4208 𝑚𝑤
= 22,4040 𝑚𝑤
𝐸𝑙𝑜𝑠𝑠 = 𝐸𝑖𝑛 − 𝐸𝑜𝑢𝑡
= 23,5726 𝑚𝑤 − 22,4040 𝑚𝑤
= 1,1686 𝑚𝑤
𝐸𝑜𝑢𝑡
𝜀=
𝐸𝑖𝑛
22,4040 𝑚𝑤
= 𝑥 100%
23,5726 𝑚𝑤
= 95,04 %