Statement for Linked Answer Questions: 1 and 2
In the following network, the voltage magnitudes at all buses are equal to 1 pu,
the voltage phase angles are very small, and the line resistances are negligible. All
the line reactances are equal to j1W
Q. 1If the base impedance and the line-to line base voltage are 100 ohms and 100 kV respectively, then the real power in MW
delivered by the generator connected at the slack bus is :
(A) -10
(B) 0
(C) 10
(D) 20
Q. 3 A two-phase load draws the following phase currents : i1(t) = Im sin(wt - f1), i2(t) = Im cos (wt - f2). These currents are balanced
if f1 is equal to.
(A) -f2
(B) f2
(C) (p/2 - f2)
(D) (p/2 + f2)
Q. 4 The figure shows a two-generator system applying a load of PD = 40MW, connected at bus 2.
Q. 6Match the items in List-I (Type of transmission line) with the items in List-II
(Type of distance relay preferred) and select the correct answer using the codes
given below the lists.
List-I List-II
a. Short Line 1. Ohm Relay
b. Medium Line 2. Reactance Relay
c. Long Line 3. Mho Relay
Q. 7 A 500 MW, 21 kV, 50 Hz, 3-phase, 2-pole synchronous generator having a rated
p.f = 0.9, has a moment of inertia of 27.5 103 # kg-m2 .The inertia constant (H
) will be
(A) 2.44 s
(B) 2.71 s
(C) 4.88 s
(D) 5.42 s
Q. 8 Three generators are feeding a load of 100 MW. The details of the generators are
In the event of increased load power demand, which of the following will happen ?
(A) All the generator will share equal power
(B) Generator-3 will share more power compared to Generator-1
(C) Generator-1 will share more power compared to Generator-2
(D) Generator-2 will share more power compared to Generator-3
Q. 9 An extra high voltage transmission line of length 300 km can be approximate by a lossless line having propagation constant
b = 0.00127 radians per km. Then the percentage ratio of line length to wavelength will be given by
(A) 24.24 %
(B) 12.12 %
(C) 19.05 %
(D) 6.06 %
Q. 10A loss less transmission line having Surge Impedance Loading (SIL) of 2280 MW is provided with a uniformly distributed
series capacitive compensation of 30%. Then, SIL of the compensated transmission line will be
(A) 1835 MW
(B) 2280 MW
(C) 2725 MW
(D) 3257 MW
Q. 11
Q. 12
Q. 13
Q. 14
Q. 15
Q. 16
Q. 17
Q. 18
Q. 19
Q. 20
Q. 21
Q. 22
Q. 23
Q. 24
Q. 25
Q. 26
Q. 27
Q. 28
Q. 29
Q. 30
Q. 31
Q. 32
Q. 33
Q. 34
Q. 35
Q. 36
Q. 37
Q. 38
Q. 39
Q. 40
Q. 41
Q. 42
Q. 43
Q. 44
Q. 45
Q. 46
Q. 47
Q. 48
Q. 49
Q. 50
Q. 51
Q. 52
Q. 53
Q. 54
Q. 55
Q. 56
Q. 57
Q. 58
Q. 59
Q. 60