KEY OPERATIONS :
Count mode: Enable S-on mode, Press [0 ] +[] [][T] keys
Calibration mode: Enable S-on mode, Press [0 ] + [] [T] [T]
keys.
Set point Programming mode: Press [0 ] + [] [] [] keys.
Calibration procedure :
Calibration using full scale machine capacity / 1/3 rd of Machine Capacity
Note: During calibration process, Press [TARE] key to exit from calibration mode.
1.CUSTOMER SPECIFICATION:
SPEC MOST SIGNIFICANT DIGIT(MSD) LEAST SIGNIFICANT DIGIT(LSD)
C10 RS232/RS485 DATA BITS & PARITY: RS232/RS485 Baud Rate (Stop bit =1):
1-> 8 Data Bits & NO Parity 1 -> 1200
2 -> 7 Data Bits & NO Parity 2 -> 2400
3 -> 8 Data Bits & ODD Parity 3 -> 4800
4 -> 7 Data Bits & ODD Parity 4 -> 9600
5 -> 8 Data Bits & EVEN Parity 5 -> 19200
6 -> 7 Data Bits & EVEN Parity Note 3
Note 3
C11 RS232/RS485 Weight Data Transfer: RS232 Data Transfer Mode:
1 -> All 1 -> Stream
2 -> Net only 2 -> Manual
3 -> Gross only 3 -> Command (CTRL E)
4 -> Auto Weight Transfer
5 -> Postal(Meghdooth)
6 -> Milkotronics (W1 to W9)
7 -> Manual Serial Print
8 -> Auto Serial Print
C12 RS232/RS485 Weight Header: RS232/RS485 Transfer Stable
1 -> No Weight/Manual Serial Print:
2 -> Numeric 0 -> No
3 -> Alpha 1 -> Yes
C13 RS232 One Touch Tare from PC On RS232/RS485 Data :
Stable(T/t): 0 ->Variable
0 -> No 1 -> Fixed ( 8 characters)
1 -> Yes
C14 RS232 Stream Data Transfer Mode Skip “STX” Character In RS232 Output:
Stable Status Flag: 0 -> No
0 -> No 1 -> Yes
1 -> Yes
C15 Setpoint Output Type: Setpoint Output Logic:
1 > Active Low 1 -> Logic I (Bar Mode)
2 -> Active High 2 -> Logic II (Dot Mode)
C16 Negative Setpoint Output: VFD Standby Mode (In Battery):
0 -> No 0 -> No
1 -> Yes 1 -> 5 Minute
2 -> 10 Minute
C17 No. of CR & LFs after Total Print: Serial Printout Format:
0 -> FORM FEED 0 -> 80 col All Wt.
1 -> 1 CR LF 1 -> 40 col All Wt.
~ 2 -> Net Wt only.
9 -> 9 CR LF
C18 RS485 Weighing Scale ID:
00 -> Reserved
01 – 99
C19 Not used Not used
2.TECHNICAL SPECIFICATION:
SPEC MOST SIGNIFICANT DIGIT(MSD) LEAST SIGNIFICANT DIGIT(LSD)
T10 Dual Accuracy (Upto 50% of Decimal Point Position:
Capacity): 0 -> No Decimal point
0 - No 1 -> 1 DP
1 - Yes 2 -> 2 DP
DISPLAY RESOLUTION SHOULD BE LESS THAN 3 -> 3 DP
OR EQUAL TO 1/15000 & SPEC T11 IS AMONG 4 -> 4 DP
02, 05, 10, 20 AND 50 VALUES for dual range.
T11 Accuracy (2 digits):
T12 Capacity:
T13 Power Fail Return: Tare Limit:
0 -> No 1 -> Capacity
1 -> Yes 2 -> 1/2Capacity – 1
100% TARE LIMIT IS NOT POSSIBLE IF DUAL
RANGE IS WORKING.
T14 Power On Start Range: Forced Zero Tracking:
1 -> 25% of capacity 0 -> ¼ d
2 -> Unlimited 1 -> 1d
2 -> 2 d
2 -> 2d
3 -> 3d
4 -> 4d
5 -> 5d
T15 RS232 Minimum Weight Transfer Serial Interface Option:
Limit: 0 -> No
0 -> No limit 1 -> RS232
1 -> Net >/ 1d 2 -> RS485
2 -> Net >/ 5d Note 3
3 -> Net >/ 20d
T16 S-On Through Key Board: Second Serial Interface Option:
0 -> Yes 0 -> No
1 -> No 1 -> RS232
Note 3
T17 ADC Gain: Unit Conversion:
1 -> UNITY 0 -> No
2 -> Double 1 -> Carat ( 5.0000 )
Note 3 2 -> Tola ( 0.085734)
3 -> Litre (Cow Milk) ( 0.9724 )
4 -> Litre (Soya Oil) (1.0989 )
5 -> Milkotronics Litre constant
Range (0.9000 to 1.0000)
T18 Not used Not used
T19 Stable Indicator On: Display Brightness Level:
0 - No 3 -> 29% Blue LED
1 - Yes 4 -> 71% Red LED
5 -> 77%
6 -> 86% VFD
7 -> 93%
8 -> 100%
Note 3
Note 1 : Default is indicated by Highlighting for applicable specs.
Note 2 : If a Spec is set to a value other than specified, then default function is used.
Note 3 : The Specs will take effect only at power on. So on/off is required whenever changed.