FTKC-N Series
EDID041432
Split Type
Air Conditioners
FTKC-N Series
FTKC15NVM4 RKC15NVM4
FTKC20NVM4 RKC20NVM4
FTKC25NVM4 RKC25NVM4
Cooling Only
FTKC35NVM4 RKC35NVM4
FTKC50NVM4 RKC50NVM4
FTKC60NVM4 RKC60NVM4
1. Power Supply ..........................................................................................3
2. Functions.................................................................................................4
3. Specifications ..........................................................................................5
4. Dimensions .............................................................................................8
4.1 Indoor Unit................................................................................................8
4.2 Outdoor Unit .............................................................................................9
5. Wiring Diagrams....................................................................................10
5.1 Indoor Unit..............................................................................................10
5.2 Outdoor Unit ...........................................................................................11
6. Piping Diagrams....................................................................................12
6.1 Indoor Unit..............................................................................................12
6.2 Outdoor Unit ...........................................................................................13
7. Capacity Tables ....................................................................................15
7.1 Cooling Only...........................................................................................15
7.2 Capacity Correction Factor by the Length of Refrigerant Piping
(Reference) ............................................................................................18
8. Operation Limit......................................................................................19
9. Sound Level ..........................................................................................20
9.1 Measuring Location ................................................................................20
9.2 Indoor Unit..............................................................................................21
9.3 Outdoor Unit ...........................................................................................22
10.Electric Characteristics..........................................................................23
11.Installation Manual ................................................................................24
11.1 15/20/25/35 Class ..................................................................................24
11.2 50/60 Class ............................................................................................44
12.Operation Manual..................................................................................64
12.1 English....................................................................................................64
12.2 Indonesian..............................................................................................90
13.Optional Accessories ..........................................................................116
13.1 Option List ............................................................................................116
13.2 <KPW937B4> Air Direction Adjustment Grille......................................117
13.3 <KPW945A4> Air Direction Adjustment Grille......................................118
1. Power Supply
Indoor Unit Outdoor Unit Power Supply
FTKC15NVM4 RKC15NVM4
FTKC20NVM4 RKC20NVM4
FTKC25NVM4 RKC25NVM4 1 phase, 220 - 230 - 240 V, 50 Hz
FTKC35NVM4 RKC35NVM4 1 phase, 220 - 230 V, 60 Hz
FTKC50NVM4 RKC50NVM4
FTKC60NVM4 RKC60NVM4
2. Functions
FTKC15/20/25/35NVM4
FTKC15/20/25/35NVM4
RKC15/20/25/35NVM4
RKC15/20/25/35NVM4
FTKC50/60NVM4
FTKC50/60NVM4
RKC50/60NVM4
RKC50/60NVM4
Category Functions Category Functions
Basic Inverter (with inverter power control) z z Health & Air-purifying filter — —
Function Clean
Operation limit for cooling (°CDB) 19.4 19.4 Photocatalytic deodorising filter — —
~ 46 ~ 46
Air-purifying filter with photocatalytic
Operation limit for heating (°CWB) — — deodorising function — —
3. Specifications
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Indoor Unit FTKC15NVM4 FTKC20NVM4
Model
Outdoor Unit RKC15NVM4 RKC20NVM4
kW 1.5 (1.2 ~ 1.9) 2.0 (1.2 ~ 2.4)
Capacity Btu/h 5,100 (4,100 ~ 6,500) 6,800 (4,100 ~ 8,200)
Rated (Min. ~ Max.)
kcal/h 1,290 (1,030 ~ 1,630) 1,720 (1,030 ~ 2,060)
Moisture Removal L/h 1.2 1.2
Running Current (Rated) A 2.7 - 2.6 - 2.5 / 2.7 - 2.6 3.5 - 3.4 - 3.2 / 3.5 - 3.4
Power Consumption (Rated) W 360 550
Power Factor (Rated) % 62.4 - 61.9 - 61.7 / 62.4 - 61.9 71.4 - 70.3 - 71.6 / 71.4 - 70.3
COP (Rated) W/W 4.17 3.64
Liquid mm φ 6.4 φ 6.4
Piping φ 9.5 φ 9.5
Connections Gas mm
Drain mm φ 16.0 φ 16.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 15 15
Max. Interunit Height Difference m 12 12
Chargeless m 10 10
Amount of Additional Charge of g/m 20 20
Refrigerant
Indoor Unit FTKC15NVM4 FTKC20NVM4
Front Panel Colour Shiny Pure White Shiny Pure White
H 9.0 (318) 9.0 (318)
M m³/min 6.7 (237) 6.7 (237)
Airflow Rate (cfm)
L 4.4 (155) 4.4 (155)
SL 3.5 (124) 3.5 (124)
Type Cross Flow Fan Cross Flow Fan
Fan Motor Output W 16 16
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards Right, Left, Horizontal, Downwards
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.19 - 0.18 - 0.17 / 0.19 - 0.18 0.19 - 0.18 - 0.17 / 0.19 - 0.18
Power Consumption (Rated) W 39 39
Power Factor (Rated) % 93.3 - 94.2 - 95.6 / 93.3 - 94.2 93.3 - 94.2 - 95.6 / 93.3 - 94.2
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 283 × 770 × 203 283 × 770 × 203
Packaged Dimensions (H × W × D) mm 263 × 840 × 344 263 × 840 × 344
Weight (Mass) kg 8 8
Gross Weight (Gross Mass) kg 10 10
Sound
Pressure H / M / L / SL dB(A) 38 / 33 / 25 / 22 38 / 33 / 25 / 22
Level
Outdoor Unit RKC15NVM4 RKC20NVM4
Casing Colour Ivory White Ivory White
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Compressor Model 1YC25BXD 1YC25BXD
Motor Output W 860 860
Refrigerant Type FW68DA FW68DA
Oil Charge L 0.350 0.350
Type R-32 R-32
Refrigerant
Charge kg 0.5 0.5
Airflow Rate H m³/min 27.1 (957) 27.1 (957)
(cfm)
Type Propeller Propeller
Fan
Motor Output W 20 20
Running Current (Rated) A 2.51 - 2.42 - 2.33 / 2.51 - 2.42 3.31 - 3.22 - 3.03 / 3.31 - 3.22
Power Consumption (Rated) W 321 511
Power Factor (Rated) % 60.0 - 59.6 - 59.2 / 60.0 - 59.6 70.2 - 69.0 - 70.2 / 70.2 - 69.0
Starting Current A 2.5 2.5
Dimensions (H × W × D) mm 550 × 658 × 275 550 × 658 × 275
Packaged Dimensions (H × W × D) mm 616 × 788 × 359 616 × 788 × 359
Weight (Mass) kg 28 28
Gross Weight (Gross Mass) kg 32 32
Sound
Pressure H dB(A) 46 - 47 - 47 / 48 - 49 46 - 47 - 47 / 48 - 49
Level
Drawing No. 3D089101A 3D089102A
Note: The data are based on the conditions shown in the table below.
Cooling Piping Length Conversion Formulae
Note: The data are based on the conditions shown in the table below.
Cooling Piping Length Conversion Formulae
Note: The data are based on the conditions shown in the table below.
Cooling Piping Length Conversion Formulae
4. Dimensions
4.1 Indoor Unit
FTKC15/20/25/35NVM4
PERFORMANCE)
REAR
770
(SPACE FOR
30MIN.
LEFT RIGHT
INCLUDING
MOUNTING PLATE
205 50MIN. 50MIN.
203 (SPACE FOR REQUIRED SPACE (SPACE FOR
FRONT PANEL FIXING SCREWS
(INSIDE) MAINTENANCE) MAINTENANCE)
MANUFACTURER' S
LABEL
SIGNAL RECEIVER
283
OPERATION LAMP TERMINAL BLOCK
TIMER LAMP WITH EARTH
LOW WATT FUNCTION TERMINAL
(INSIDE)
BOTTOM FLAPS INDOOR UNIT ON/OFF SWITCH
GAS PIPE φ9.5 CuT DRAIN HOSE
ROOM TEMP. THERMISTOR
(THE LENGTH OF PIPE OUTSIDE (CONNECTING PART
(INSIDE)
THE UNIT : ABOUT 350) I.D. φ14
LIQUID PIPE φ6.4 CuT O.D. φ16
(THE LENGTH OF PIPE OUTSIDE THE HOSE LENGTH OF OUTSIDE
THE UNIT : ABOUT 400) THE UNIT IS ABOUT 450)
770
SIGNAL TRANSMITTER MODEL NAME
549 101
16
6
PLATE
58 18 BLADE ANGLE
172
DAIKIN
UP/DOWN (AUTOMATIC)
283
41.3
COOLING DRY
5˚ 5˚
163
41.3
WALL HOLE FOR EMBEDDED PIPING
FAN
RIGHT/LEFT (MANUAL) φ65 HOLE
WALL HOLE
5˚ STANDARD LOCATIONS OF WALL HOLES φ65 HOLE
FTKC50/60NVM4
PERFORMANCE)
REAR REAR
LEFT RIGHT
(SPACE FOR
MIN.30
( INSTALLATION
INCLUDING
PLATE )
239
237
MIN.50 MIN.50
MODEL NAME (SPACE FOR (SPACE FOR
PLATE MAINTENANCE) REQUIRED SPACE MAINTENANCE)
290
COOLING DRY
14.5
155.5
10˚ 5˚
290
(163)
52
40˚ 10˚ 5˚
35˚
40˚ 35˚
FAN
VERTICAL BLADE (MANUAL)
52
RKC15/20/25/35NVM4
150
4-HOLES FOR ANCHOR BOLTS
WITH DRAIN JOINT) (M8 OR M10)
470 96
379
11
100
150
40
50 50
300
50
297
50
100
HANDLE BRAND NAME LABEL MANUFACTURE'S LABEL
275 13.5 12 658 50 8 OUTDOOR AIR THERMISTOR
LIQUID
STOP VALVE
WIRING (φ6.4 CuT)
INLET
550
SERVICE
PORT
168
108
155
GAS STOP VALVE
(φ9.5 CuT)
INDICATION LABEL (INDONESIA)
FOR INDONESIA MODEL ONLY IN CASE OF REMOVING
STOP VALVE COVER
3D089153
RKC50/60NVM4
DRAIN OUTLET MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE
100
(I.D.φ15.9 HOSE FOR CONNECTION) =LESS THAN 1200
825 78
325
100
124 580
350
2
36
50 50
50
350
350
330
300
100
350
IN CASE OF REMOVING
STOP VALVE COVER
10
25
89 64
3D083536B
5. Wiring Diagrams
5.1 Indoor Unit
FTKC15/20/25/35NVM4
3D089034
FTKC50/60NVM4
3D088911
RKC15/20/25/35NVM4
RKC50/60NVM4
6. Piping Diagrams
6.1 Indoor Unit
FTKC15/20/25/35NVM4 FTKC50/60NVM4
INDOOR UNIT
INDOOR UNIT
HEAT EXCHANGER
7.0 CuT
4.8 CuT
(7.9 CuT)
7.0 CuT
THERMISTOR
CROSS FLOW FAN ON HEAT EXCH.
FIELD PIPING
(6.4 CuT)
M FIELD PIPING
CROSS FLOW FAN
REFRIGERANT FLOW
COOLING REFRIGERANT FLOW
COOLING
4D075755A 4D083425C
RKC15/20/25NVM4
OUTDOOR UNIT
OUTDOOR TEMPERATURE
6.4 CuT HEAT EXCHANGER THERMISTOR
6.4 CuT
7.0 CuT
HEAT EXCHANGER
MOTOR OPERATED
THERMISTOR
VALVE
6.4 CuT 6.4 CuT 6.4 CuT
FAN MUFFLER
6.4 CuT
M MOTOR WITH
FILTER
PROPELLER FAN
STRAINER
4.8 CuT
6.4 CuT
9.5 CuT
FIELD PIPING
LIQUID STOP (6.4 CuT)
VALVE
REFRIGERANT FLOW
DISCHARGE PIPE 9.5 CuT FIELD PIPING
COMPRESSOR COOLING
THERMISTOR (9.5 CuT)
MUFFLER MUFFLER GAS STOP
ACCUMULATOR VALVE
3D089192A
RKC35NVM4
OUTDOOR UNIT
7.0 CuT
HEAT EXCHANGER
MOTOR OPERATED
THERMISTOR
VALVE
6.4 CuT 6.4 CuT 6.4 CuT
MUFFLER
FAN
M WITH
6.4 CuT
MOTOR
FILTER
PROPELLER FAN
STRAINER
4.8 CuT
7.9 CuT
9.5 CuT
FIELD PIPING
REFRIGERANT FLOW
(6.4 CuT)
LIQUID STOP
COOLING
VALVE
9.5 CuT FIELD PIPING
DISCHARGE PIPE COMPRESSOR
THERMISTOR (9.5 CuT)
MUFFLER MUFFLER GAS STOP
ACCUMULATOR VALVE
3D089185A
RKC50/60NVM4
OUTDOOR UNIT
HEAT EXCHANGER
7.0 CuT OUTDOOR TEMPERATURE
THERMISTOR
7.0 CuT
M
7.9 CuT
6.4 CuT
PROPELLER FAN
FIELD PIPING
MUFFLER (6.4 CuT)
LIQUID STOP
DISCHARGE PIPE VALVE
THERMISTOR 12.7 CuT
COMPRESSOR FIELD PIPING
ACCUMULATOR 12.7 CuT (12.7 CuT)
GAS STOP
VALVE
REFRIGERANT FLOW
COOLING
3D090240
7. Capacity Tables
7.1 Cooling Only
FTKC15NVM4 + RKC15NVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 9
BF 0.33
Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D089841
FTKC20NVM4 + RKC20NVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 9
BF 0.11
Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D089842
FTKC25NVM4 + RKC25NVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 9
BF 0.10
Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D089843
FTKC35NVM4 + RKC35NVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 9.2
BF 0.12
Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D089844
FTKC50NVM4 + RKC50NVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 14.3
BF 0.07
Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D089845
FTKC60NVM4 + RKC60NVM4 (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 15.4
BF 0.08
Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D089846
Cooling (R-32)
(%)
100
Capacity correction factor
90
Range of the
refrigerant
80
additional
charge
5 10 15 (m)
Piping length
(R20651)
Cooling (R-32)
(%)
100
Capacity correction factor
90
80
Range of the refrigerant additional charge
5 10 15 20 25 30 (m)
Piping length
(R20375)
Note: The graphs show the factor when additional refrigerant of the proper quantity is charged.
8. Operation Limit
RKC15/20/25/35NVM4
50
46
40
Continuous operation
Pull-down period
30
20
19.4
Notes : 10 14 20 23 28 30
The graph is based Indoor temp. (˚CWB)
on the following conditions.
· Equivalent piping length 7.5m
· Level difference 0m
· Air flow rate High
4D073983E
RKC50/60NVM4
50
46
40
Outdoor temp. (˚CDB)
Continuous operation
Pull-down period
30
20
19.4
Notes : 10 14 20 23 28 30
The graph is based Indoor temp. (˚CWB)
on the following conditions.
• Equivalent piping length 7.5m
• Level difference 0m
• Air flow rate High
4D083533A
9. Sound Level
9.1 Measuring Location
1m 1m
0.8 m
MICROPHONE
MICROPHONE
dB (0dB=0.0002µ bar)
50 50
OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
NC-50
POWER SOURCE 220-240/220-230V 50/60Hz POWER SOURCE 220-240/220-230V 50/60Hz
JIS STANDARD JIS STANDARD
40 40
NC-40 220-240/220-230V 50/60Hz (H) NC-40 220-240/220-230V 50/60Hz (H)
220-240/220-230V 50/60Hz (L) 220-240/220-230V 50/60Hz (L)
30 Cooling 30 Cooling
NC-30 NC-30
20 20
APPROXIMATE NC-20 APPROXIMATE
THRESHOLD HEARING NC-20
THRESHOLD HEARING
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D089373 63 125 250 500 1000 2000 4000 8000 4D089375
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
FTKC25NVM4 FTKC35NVM4
50 50
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 220-240/220-230V 50/60Hz POWER SOURCE 220-240/220-230V 50/60 Hz
20 20
APPROXIMATE APPROXIMATE NC-20
NC-20
THRESHOLD HEARING THRESHOLD HEARING
FOR CONTINUOUS FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D089376 63 125 250 500 1000 2000 4000 8000 4D089379
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
FTKC50NVM4 FTKC60NVM4
50 50
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 220-240/220-230V 50/60Hz POWER SOURCE 220-240/220-230V 50/60Hz
JIS STANDARD JIS STANDARD
40 40
NC-40 220-240/220-230V 50/60Hz (H) NC-40 220-240/220-230V 50/60Hz (H)
220-240/220-230V 50/60Hz (L) 220-240/220-230V 50/60Hz (L)
30 Cooling 30 Cooling
NC-30 NC-30
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING THRESHOLD HEARING
FOR CONTINUOUS NC-20 FOR CONTINUOUS NC-20
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D089508 63 125 250 500 1000 2000 4000 8000 4D089509
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
COOLING COOLING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
50Hz 60Hz 50Hz 60Hz
SCALE SCALE
220-230-240V 220-230V
60 60
NC-60 A 46-47-47 48-49 NC-60 A 46-47-47 48-49
dB (0dB=0.0002µ bar)
50 50
dB (0dB=0.0002µ bar)
30 30
NC-30 NC-30
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING THRESHOLD HEARING NC-20
FOR CONTINUOUS NC-20 FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D089382A 63 125 250 500 1000 2000 4000 8000 4D089383A
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
RKC25NVM4 RKC35NVM4
COOLING COOLING
70 OVER ALL (dB) 70 OVER ALL (dB)
NC-70 NC-70
50Hz 60Hz 50Hz 60Hz
SCALE SCALE
220-230-240V 220-230V 220-230-240V 220-230V
OCTAVE BAND SOUND PRESSURE LEVEL
OCTAVE BAND SOUND PRESSURE LEVEL
60 60
NC-60 A 47-48-48 49-50 NC-60 A 49-49-50 49-50
50
dB (0dB=0.0002µ bar)
50
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 220-240/220-230V 50/60Hz (H) POWER SOURCE 220-240/220-230V 50/60Hz (H)
30 30
NC-30
NC-30
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING THRESHOLD HEARING NC-20
FOR CONTINUOUS NC-20 FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D089389A 63 125 250 500 1000 2000 4000 8000 4D089392A
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
RKC50NVM4 RKC60NVM4
SCALE SCALE
OCTAVE BAND SOUND PRESSURE LEVEL
dB (0dB=0.0002µ bar)
50 50
NC-50 OPERATING CONDITIONS NC-50 OPERATING CONDITIONS
POWER SOURCE 220-240/220-230V 50/60Hz (H) POWER SOURCE 220-240/220-230V 50/60Hz (H)
40 JIS STANDARD 40 JIS STANDARD
NC-40 NC-40
220-240/220-230V 50/60Hz (H) 220-240/220-230V 50/60Hz (H)
30 30
NC-30
NC-30
20 20
APPROXIMATE APPROXIMATE
THRESHOLD HEARING NC-20 THRESHOLD HEARING
FOR CONTINUOUS NC-20
FOR CONTINUOUS
NOISE NOISE
63 125 250 500 1000 2000 4000 8000 4D088836A 63 125 250 500 1000 2000 4000 8000 4D088837A
OCTAVE BAND CENTER FREQUENCY (Hz) OCTAVE BAND CENTER FREQUENCY (Hz)
Symbols: Notes:
MCA : Min. circuit amps (A) 1. RLA is based on the following conditions.
Indoor temp. 27°CDB / 19°CWB
MFA : Max. fuse amps (A) Outdoor temp. 35°CDB
RHz : Rated operating frequency (Hz) 2. Maximum allowable voltage variation between phases is 2%.
3. Select wire size based on the larger value of MCA.
RLA : Rated load amps (A) 4. Instead of fuse, use circuit breaker.
OFM : Outdoor fan motor 5. Be sure to install an earth leak detector.
(This unit uses an inverter, which means that an earth leak
IFM : Indoor fan motor detector capable of handling high harmonics must be used in
W : Fan motor rated output (W) order to prevent malfunctioning of the earth leak detector.)
FLA : Full load amps (A)
3D089021
EN_3P363835-14C
11.1.2 Indonesian
ID_3P363835-14C
EN_3P363835-15C
11.2.2 Indonesian
ID_3P363835-15C
EN_3P363834-8B
12.2 Indonesian
ID_3P363834-8B
4P202735-1
3P089958-2C
Specifications, designs and other content appearing in this brochure are current as of August 2014 but subject to change without notice.
AK