Split Type Air Conditioners


- Cooling Only -

FTKZ-V Series
EDTVN042125

Split Type
Air Conditioners
FTKZ-V Series
FTKZ25VVMV RKZ25VVMV
FTKZ35VVMV RKZ35VVMV
Cooling Only FTKZ50VVMV RKZ50VVMV
FTKZ60VVMV RKZ60VVMV
FTKZ71VVMV RKZ71VVMV
1. Power Supply ..........................................................................................2
2. Functions.................................................................................................3
3. Specifications ..........................................................................................4
4. Dimensions .............................................................................................7
4.1 Indoor Unit................................................................................................7
4.2 Outdoor Unit .............................................................................................8
5. Wiring Diagrams......................................................................................9
5.1 Indoor Unit................................................................................................9
5.2 Outdoor Unit ...........................................................................................10
6. Piping Diagrams....................................................................................11
6.1 Indoor Unit..............................................................................................11
6.2 Outdoor Unit ...........................................................................................12
7. Capacity Tables ....................................................................................14
7.1 Cooling Only...........................................................................................14
7.2 Capacity Correction Factor by the Length of Refrigerant Piping
(Reference) ............................................................................................17
8. Operation Limit......................................................................................18
9. Sound Level ..........................................................................................19
9.1 Measuring Location ................................................................................19
9.2 Indoor Unit..............................................................................................20
9.3 Outdoor Unit ...........................................................................................21
10.Electric Characteristics..........................................................................23
11.Installation Manual ................................................................................24
11.1 25/35 Class ............................................................................................24
11.2 50/60/71 Class .......................................................................................34
12.Operation Manual..................................................................................44
12.1 English....................................................................................................44
12.2 Vietnamese ..........................................................................................126
13.Optional Accessories ..........................................................................208
13.1 Indoor Unit............................................................................................208
13.2 Outdoor Unit .........................................................................................208

Split Type Air Conditioners FTKZ-V Series 1


Power Supply EDTVN042125

1. Power Supply
Indoor Unit Outdoor Unit Power Supply
FTKZ25VVMV RKZ25VVMV
FTKZ35VVMV RKZ35VVMV
1 phase, 220 - 230 - 240 V, 50 Hz
FTKZ50VVMV RKZ50VVMV 1 phase, 220 - 230 V, 60 Hz
FTKZ60VVMV RKZ60VVMV
FTKZ71VVMV RKZ71VVMV

Note: Power Supply Intake ; Outdoor Unit

2 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Functions

2. Functions

FTKZ50/60/71VVMV

FTKZ50/60/71VVMV
RKZ50/60/71VVMV

RKZ50/60/71VVMV
FTKZ25/35VVMV

FTKZ25/35VVMV
RKZ25/35VVMV

RKZ25/35VVMV
Category Functions Category Functions

Basic Functions Inverter (with inverter power control)   Health & Air quality filter
Cleanliness (enzyme blue / PM2.5) (option)  
Refer to
Operation limit for cooling
P. 18 Deodorizing filter (enzyme blue)  
Operation limit for heating — — Titanium apatite deodorizing filter
(option)  
PAM control  
Standby electricity saving   Dust collection filter (PM2.5) (option)  
Compressor Oval scroll compressor — — Mould proof air filter (prefilter)  
Swing compressor   Wipe-clean panel  
Rotary compressor — — Washable panel — —
Reluctance DC motor   Removable drain-pan  
Comfortable Power-airflow flap — — Mould proof operation  
Airflow
Power-airflow dual flaps   Mould proof operation with streamer — —
Power-airflow diffuser — — Heating dry operation — —
Wide-angle louvres   Good-sleep cooling operation — —
Auto-swing (up and down) Odour removing  
with position indication  
Flash streamer  
Auto-swing (left and right) Timer Weekly timer — —
with position indication  
24-hour ON/OFF timer  
3D airflow   Count up-down ON/OFF timer  
Comfort airflow mode Night set mode  
 
(COANDA flap: ceiling) Worry Free Auto-restart after power failure  
(Reliability &
Comfort Control Auto fan speed   Durability) Self-diagnosis with remo-con  
Indoor unit quiet operation   Wiring error check — —
Outdoor unit quiet operation   Anti-corrosion treatment of outdoor  
Intelligent eye (auto energy saving)   heat exchanger fins

2-area intelligent eye Protection net of outdoor unit — —


 —
(focus and comfort) Low/high voltage shield  
Hot-start function — — Flexibility Multi-split/split compatible indoor
— —
Automatic defrost — — unit
Operation Automatic operation Chargeless 10 m 15 m
— —
(cooling and heating) Either side drain (right/left)  
Programme dry function — — Power selection — —
Hybrid cooling   Remote Control Remote control adaptor
 
Fan operation   (normal open pulse contact) (option)
Lifestyle Powerful operation (non-inverter) — — Remote control adaptor
Convenience  
Inverter powerful operation   (normal open contact) (option)
Cooling/heating mode lock — — HA and Dlll-NET application (option)  
Home leave operation — — Wireless LAN adaptor (built-in)  
Econo mode   Remote Wireless  
Controller
Indoor unit ON/OFF switch   Wired — —
Signal reception indicator  
0.5°C step room temperature setting  
16°C setting for cooling mode  
Wireless remote controller
 
(backlight)

Wireless remote controller


— —
(luminous button)
Temperature display — —
Note:  : Available
— : Not available

Split Type Air Conditioners FTKZ-V Series 3


Specifications EDTVN042125

3. Specifications
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Indoor Unit FTKZ25VVMV FTKZ35VVMV
Model
Outdoor Unit RKZ25VVMV RKZ35VVMV
kW 2.5 (1.2 ~ 3.6) / 1.250 3.5 (1.2 ~ 4.1) / 1.750
Capacity
Btu/h 8,500 (4,100 ~ 12,300) / 4,300 11,900 (4,100 ~ 14,000) / 6,000
Rated (Min. ~ Max.) / Half
kcal/h 2,150 (1,030 ~ 3,100) / 1,070 3,010 (1,030 ~ 3,530) / 1,500
Moisture Removal L/h 0.9 1.2
Running Current (Rated) A 2.3 3.9
Power Consumption
W 455 (160 ~ 890) / 199 790 (160 ~ 1,120) / 297
Rated (Min. ~ Max.) / Half
Power Factor (Rated) % 89.9 92.1
COP (Rated) W/W 5.49 4.43
CSPF Wh/Wh 7.24 6.68
Liquid mm  6.4  6.4
Piping
Connections Gas mm  9.5  9.5
Drain mm  16.0  16.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 20 20
Max. Interunit Height Difference m 15 15
Chargeless m 10 10
Amount of Additional Charge of
g/m 20 20
Refrigerant
Indoor Unit FTKZ25VVMV FTKZ35VVMV
Front Panel Colour (Munsell No.) Two Tone White (B-613), Light Gray (B-617) Two Tone White (B-613), Light Gray (B-617)
H 14.6 (516) 15.2 (537)
M m³/min 11.0 (388) 12.3 (434)
Airflow Rate
L (cfm) 7.0 (247) 7.9 (279)
SL 4.9 (173) 5.6 (198)
Type Cross Flow Fan Cross Flow Fan
Fan Motor Output W 30 30
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards Right, Left, Horizontal, Downwards
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.31 0.32
Power Consumption (Rated) W 30 32
Power Factor (Rated) % 44.0 45.5
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 300 × 920 × 240 300 × 920 × 240
Packaged Dimensions (H × W × D) mm 341 × 1,000 × 386 341 × 1,000 × 386
Weight (Mass) kg 13 13
Gross Weight (Gross Mass) kg 18 18
Sound
Pressure H / M / L / SL dB(A) 42 / 33 / 26 / 19 43 / 35 / 28 / 19
Level
Outdoor Unit RKZ25VVMV RKZ35VVMV
Casing Colour Ivory White Ivory White
Heat
Fin / Spec. Tube Waffle Fin /  7 Hi-XD Tube Waffle Fin /  7 Hi-XD Tube
Exchanger
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Compressor Model 1YC25DXD 1YC25DXD
Motor Output W 800 800
Refrigerant Type FW68DA FW68DA
Oil Charge L 0.375 0.375
Type R-32 R-32
Refrigerant
Charge kg 0.77 0.77
H m³/min 26.9 (950) 26.9 (950)
Airflow Rate
SL (cfm) 23.0 (812) 23.0 (812)
Type Propeller Propeller
Fan
Motor Output W 28 28
Running Current (Rated) A 2.00 3.60
Power Consumption (Rated) W 425 758
Power Factor (Rated) % 96.6 95.7
Starting Current A 2.3 3.9
Dimensions (H × W × D) mm 550 × 675 × 284 550 × 675 × 284
Packaged Dimensions (H × W × D) mm 605 × 798 × 373 605 × 798 × 373
Weight (Mass) kg 27 27
Gross Weight (Gross Mass) kg 32 32
Sound
Pressure H / SL dB(A) 46 / 43 47 / 44
Level
Drawing No. 3D133028A 3D133029A

Notes: 1. SL: The Quiet fan level of the airflow rate setting.
2. The data are based on the conditions shown in the table below. Conversion Formulae
Cooling Piping Length kcal/h = kW × 860
Btu/h = kW × 3412
Indoor ; 27°CDB / 19°CWB cfm = m³/min × 35.3
7.5 m
Outdoor ; 35°CDB / 24°CWB

4 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Specifications

50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V


Indoor Unit FTKZ50VVMV FTKZ60VVMV
Model
Outdoor Unit RKZ50VVMV RKZ60VVMV
kW 5.2 (1.2 ~ 6.2) / 2.600 6.0 (1.2 ~ 7.1) / 3.000
Capacity
Btu/h 17,100 (4,100 ~ 21,200) / 8,900 20,500 (4,100 ~ 24,200) / 10,200
Rated (Min. ~ Max.) / Half
kcal/h 4,470 (1,030 ~ 5,330) / 2,240 5,160 (1,030 ~ 6,110) / 2,580
Moisture Removal L/h 2.4 2.6
Running Current (Rated) A 6.4 7.7
Power Consumption
W 1,320 (185 ~ 2,000) / 435 1,600 (220 ~ 2,140) / 520
Rated (Min. ~ Max.) / Half
Power Factor (Rated) % 93.8 94.5
COP (Rated) W/W 3.94 3.75
CSPF Wh/Wh 6.69 6.45
Liquid mm  6.4  6.4
Piping
Connections Gas mm  12.7  12.7
Drain mm  16.0  16.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 30 30
Max. Interunit Height Difference m 20 20
Chargeless m 15 15
Amount of Additional Charge of
g/m 10 10
Refrigerant
Indoor Unit FTKZ50VVMV FTKZ60VVMV
Front Panel Colour (Munsell No.) Two Tone White (B-613), Light Gray (B-617) Two Tone White (B-613), Light Gray (B-617)
H 18.0 (636) 22.1 (780)
M m³/min 14.6 (516) 17.0 (600)
Airflow Rate
L (cfm) 12.0 (424) 12.9 (455)
SL 9.6 (339) 10.1 (357)
Type Cross Flow Fan Cross Flow Fan
Fan Motor Output W 80 80
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards Right, Left, Horizontal, Downwards
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.39 0.50
Power Consumption (Rated) W 42 56
Power Factor (Rated) % 49.0 50.8
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 300 × 1,100 × 240 300 × 1,100 × 240
Packaged Dimensions (H × W × D) mm 401 × 1,212 × 393 401 × 1,212 × 393
Weight (Mass) kg 15 15
Gross Weight (Gross Mass) kg 22 22
Sound
Pressure H / M / L / SL dB(A) 45 / 40 / 35 / 29 48 / 42 / 37 / 29
Level
Outdoor Unit RKZ50VVMV RKZ60VVMV
Casing Colour Ivory White Ivory White
Heat
Fin / Spec. Tube Louvre Fin / Flat Alu Tube Louvre Fin / Flat Alu Tube
Exchanger
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Compressor Model 2Y113BKAX1T 2Y129BKAX1T
Motor Output W 1,100 1,100
Refrigerant Type FW50DA FW50DA
Oil Charge L 0.395 0.465
Type R-32 R-32
Refrigerant
Charge kg 0.60 0.60
H m³/min 35.8 (1,264) 45.1 (1,592)
Airflow Rate
SL (cfm) 29.1 (1,028) 37.9 (1,338)
Type Propeller Propeller
Fan
Motor Output W 50 50
Running Current (Rated) A 6.00 7.20
Power Consumption (Rated) W 1,278 1,544
Power Factor (Rated) % 96.8 97.4
Starting Current A 6.4 7.7
Dimensions (H × W × D) mm 595 × 845 × 300 595 × 845 × 300
Packaged Dimensions (H × W × D) mm 660 × 995 × 410 660 × 995 × 410
Weight (Mass) kg 34 36
Gross Weight (Gross Mass) kg 40 41
Sound
Pressure H / SL dB(A) 48 / 44 49 / 45
Level
Drawing No. 3D133030B 3D133031B

Notes: 1. SL: The Quiet fan level of the airflow rate setting.
2. The data are based on the conditions shown in the table below. Conversion Formulae
Cooling Piping Length kcal/h = kW × 860
Btu/h = kW × 3412
Indoor ; 27°CDB / 19°CWB cfm = m³/min × 35.3
7.5 m
Outdoor ; 35°CDB / 24°CWB

Split Type Air Conditioners FTKZ-V Series 5


Specifications EDTVN042125

50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V


Indoor Unit FTKZ71VVMV
Model
Outdoor Unit RKZ71VVMV
kW 7.1 (1.2 ~ 7.6) / 3.550
Capacity
Btu/h 24,200 (4,100 ~ 25,900) / 12,100
Rated (Min. ~ Max.) / Half
kcal/h 6,110 (1,030 ~ 6,540) / 3,050
Moisture Removal L/h 2.9
Running Current (Rated) A 10.3
Power Consumption
W 2,140 (220 ~ 2,800) / 660
Rated (Min. ~ Max.) / Half
Power Factor (Rated) % 94.4
COP (Rated) W/W 3.32
CSPF Wh/Wh 5.98
Liquid mm  6.4
Piping
Connections Gas mm  12.7
Drain mm  16.0
Heat Insulation Both Liquid and Gas Pipes
Max. Interunit Piping Length m 30
Max. Interunit Height Difference m 20
Chargeless m 15
Amount of Additional Charge of
g/m 10
Refrigerant
Indoor Unit FTKZ71VVMV
Front Panel Colour (Munsell No.) Two Tone White (B-613), Light Gray (B-617)
H 22.1 (780)
M m³/min 17.0 (600)
Airflow Rate
L (cfm) 12.9 (455)
SL 10.1 (357)
Type Cross Flow Fan
Fan Motor Output W 80
Speed Steps 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards
Air Filter Removable, Washable, Mildew Proof
Running Current (Rated) A 0.51
Power Consumption (Rated) W 57
Power Factor (Rated) % 50.8
Temperature Control Microcomputer Control
Dimensions (H × W × D) mm 300 × 1,100 × 240
Packaged Dimensions (H × W × D) mm 401 × 1,212 × 393
Weight (Mass) kg 15
Gross Weight (Gross Mass) kg 22
Sound
Pressure H / M / L / SL dB(A) 49 / 42 / 37 / 30
Level
Outdoor Unit RKZ71VVMV
Casing Colour Ivory White
Heat
Fin / Spec. Tube Louvre Fin / Flat Alu Tube
Exchanger
Type Hermetically Sealed Swing Type
Compressor Model 2Y129BKAX1T
Motor Output W 1,100
Refrigerant Type FW50DA
Oil Charge L 0.465
Type R-32
Refrigerant
Charge kg 0.60
H m³/min 45.1 (1,592)
Airflow Rate
SL (cfm) 37.9 (1,338)
Type Propeller
Fan
Motor Output W 50
Running Current (Rated) A 9.80
Power Consumption (Rated) W 2,083
Power Factor (Rated) % 96.6
Starting Current A 10.3
Dimensions (H × W × D) mm 595 × 845 × 300
Packaged Dimensions (H × W × D) mm 660 × 995 × 410
Weight (Mass) kg 36
Gross Weight (Gross Mass) kg 41
Sound
Pressure H / SL dB(A) 52 / 49
Level
Drawing No. 3D133032

Notes: 1. SL: The Quiet fan level of the airflow rate setting.
2. The data are based on the conditions shown in the table below. Conversion Formulae
Cooling Piping Length kcal/h = kW × 860
Btu/h = kW × 3412
Indoor ; 27°CDB / 19°CWB cfm = m³/min × 35.3
7.5 m
Outdoor ; 35°CDB / 24°CWB

6 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Dimensions

4. Dimensions
4.1 Indoor Unit

FTKZ25/35VVMV

3D132634

FTKZ50/60/71VVMV

3D132635

Split Type Air Conditioners FTKZ-V Series 7


Dimensions EDTVN042125

4.2 Outdoor Unit

RKZ25/35VVMV

C: 3D133100

RKZ50/60/71VVMV

C: 3D122092

8 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Wiring Diagrams

5. Wiring Diagrams
5.1 Indoor Unit

FTKZ25/35VVMV

3D131859A

FTKZ50/60/71VVMV

3D131864A

Split Type Air Conditioners FTKZ-V Series 9


Wiring Diagrams EDTVN042125

5.2 Outdoor Unit

RKZ25/35VVMV

3D131857

RKZ50/60/71VVMV

3D111967B

10 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Piping Diagrams

6. Piping Diagrams
6.1 Indoor Unit

FTKZ25/35VVMV

4D132880

FTKZ50/60/71VVMV

4D132881

Split Type Air Conditioners FTKZ-V Series 11


Piping Diagrams EDTVN042125

6.2 Outdoor Unit

RKZ25/35VVMV

3D131796

RKZ50VVMV

3D131797

12 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Piping Diagrams

RKZ60/71VVMV

3D131798

Split Type Air Conditioners FTKZ-V Series 13


Capacity Tables EDTVN042125

7. Capacity Tables
7.1 Cooling Only

FTKZ25VVMV + RKZ25VVMV (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 14.6
BF 0.31

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 2.46 2.25 0.35 2.35 2.20 0.38 2.23 2.15 0.42 2.28 2.17 0.43 2.21 2.14 0.45 2.10 2.09 0.48
16.0 22 2.57 2.21 0.35 2.46 2.17 0.39 2.34 2.12 0.42 2.40 2.14 0.43 2.33 2.11 0.45 2.21 2.07 0.49
18.0 25 2.68 2.38 0.36 2.57 2.34 0.39 2.46 2.29 0.42 2.51 2.31 0.43 2.44 2.29 0.45 2.33 2.24 0.49
19.0 27 2.73 2.56 0.36 2.62 2.52 0.39 2.51 2.48 0.42 2.57 2.50 0.43 2.50 2.47 0.46 2.53 2.48 0.49
22.0 30 2.90 2.49 0.36 2.79 2.45 0.39 2.68 2.42 0.43 2.74 2.44 0.44 2.67 2.42 0.46 2.56 2.38 0.49
24.0 32 3.01 2.44 0.36 2.90 2.41 0.39 2.79 2.38 0.43 2.86 2.40 0.44 2.79 2.38 0.46 2.67 2.34 0.49

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D133103

FTKZ35VVMV + RKZ35VVMV (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 15.2
BF 0.16

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 3.44 3.01 0.61 3.28 2.93 0.67 3.13 2.86 0.73 3.19 2.89 0.75 3.10 2.85 0.78 2.93 2.78 0.84
16.0 22 3.60 2.96 0.61 3.44 2.89 0.67 3.28 2.82 0.73 3.36 2.86 0.75 3.26 2.81 0.78 3.10 2.75 0.84
18.0 25 3.75 3.16 0.62 3.59 3.10 0.68 3.44 3.04 0.73 3.52 3.07 0.75 3.42 3.03 0.79 3.26 2.97 0.85
19.0 27 3.83 3.39 0.62 3.67 3.33 0.68 3.51 3.27 0.74 3.60 3.30 0.75 3.50 3.27 0.79 3.34 3.21 0.85
22.0 30 4.06 3.29 0.62 3.90 3.24 0.68 3.75 3.19 0.74 3.84 3.22 0.76 3.74 3.19 0.80 3.58 3.13 0.85
24.0 32 4.21 3.23 0.63 4.06 3.18 0.69 3.90 3.13 0.74 4.00 3.16 0.76 3.90 3.13 0.80 3.74 3.08 0.86

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D133104

14 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Capacity Tables

FTKZ50VVMV + RKZ50VVMV (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 18.0
BF 0.09

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 5.11 4.17 1.02 4.88 4.06 1.12 4.65 3.95 1.21 4.75 4.00 1.25 4.60 3.93 1.31 4.36 3.82 1.40
16.0 22 5.34 4.10 1.02 5.11 4.00 1.12 4.88 3.90 1.22 4.99 3.94 1.25 4.84 3.88 1.31 4.60 3.78 1.41
18.0 25 5.57 4.35 1.03 5.34 4.26 1.13 5.11 4.16 1.23 5.23 4.21 1.26 5.08 4.15 1.32 4.84 4.05 1.41
19.0 27 5.69 4.64 1.03 5.45 4.55 1.13 5.22 4.46 1.23 5.35 4.50 1.26 5.20 4.45 1.32 4.96 4.35 1.42
22.0 30 6.03 4.49 1.04 5.80 4.41 1.14 5.57 4.33 1.24 5.70 4.38 1.27 5.56 4.33 1.33 5.32 4.25 1.43
24.0 32 6.26 4.39 1.05 6.03 4.32 1.15 5.80 4.24 1.24 5.94 4.29 1.28 5.80 4.25 1.33 5.56 4.17 1.43

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D133105

FTKZ60VVMV + RKZ60VVMV (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 22.1
BF 0.11

INDOOR OUTDOOR TEMPERATURE (°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 5.90 4.91 1.23 5.63 4.78 1.35 5.36 4.66 1.47 5.48 4.71 1.51 5.31 4.64 1.58 5.03 4.51 1.70
16.0 22 6.16 4.83 1.24 5.90 4.71 1.36 5.63 4.60 1.48 5.75 4.65 1.52 5.59 4.58 1.59 5.31 4.46 1.71
18.0 25 6.43 5.13 1.25 6.16 5.03 1.37 5.89 4.92 1.49 6.03 4.97 1.53 5.86 4.91 1.60 5.58 4.79 1.71
19.0 27 6.56 5.48 1.25 6.29 5.38 1.37 6.03 5.28 1.49 6.17 5.33 1.53 6.00 5.27 1.60 5.72 5.16 1.72
22.0 30 6.96 5.32 1.26 6.69 5.22 1.38 6.42 5.13 1.50 6.58 5.19 1.54 6.41 5.13 1.61 6.14 5.04 1.73
24.0 32 7.23 5.20 1.27 6.96 5.12 1.39 6.69 5.03 1.51 6.86 5.09 1.55 6.69 5.03 1.62 6.41 4.95 1.74

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D133106

Split Type Air Conditioners FTKZ-V Series 15


Capacity Tables EDTVN042125

FTKZ71VVMV + RKZ71VVMV (50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V)
AFR 22.1
BF 0.11

INDOOR OUTDOOR TEMPERATURE(°CDB)


EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20 6.98 5.43 1.65 6.66 5.27 1.81 6.35 5.12 1.97 6.48 5.19 2.02 6.28 5.09 2.12 5.95 4.93 2.27
16.0 22 7.29 5.33 1.66 6.98 5.19 1.82 6.66 5.05 1.98 6.81 5.11 2.03 6.61 5.03 2.13 6.28 4.88 2.28
18.0 25 7.61 5.62 1.67 7.29 5.49 1.83 6.97 5.36 1.99 7.13 5.43 2.04 6.94 5.34 2.14 6.61 5.21 2.29
19.0 27 7.76 5.97 1.67 7.45 5.84 1.83 7.13 5.71 1.99 7.30 5.78 2.05 7.10 5.70 2.14 6.77 5.57 2.30
22.0 30 8.24 5.77 1.69 7.92 5.65 1.85 7.60 5.54 2.01 7.79 5.61 2.06 7.59 5.54 2.15 7.26 5.42 2.31
24.0 32 8.55 5.63 1.70 8.23 5.52 1.86 7.92 5.42 2.02 8.12 5.48 2.07 7.92 5.42 2.16 7.59 5.31 2.32

Symbols: Notes:
AFR : Airflow rate (m³/min.) 1. shows nominal (rated) capacities and power input.
2. TC, PI and SHC must be calculated by interpolation using the figures in
BF : Bypass factor the above tables.
EWB : Entering wet bulb temp. (°C) (Figures out of the tables should not be used for calculation.)
3. Capacities are based on the following conditions.
EDB : Entering dry bulb temp. (°C) Corresponding refrigerant piping length : 7.5 m
TC : Total capacity (kW) Level difference : 0 m
SHC : Sensible heat capacity (kW)
PI : Power input (kW)
3D133108

16 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Capacity Tables

7.2 Capacity Correction Factor by the Length of Refrigerant Piping (Reference)


The cooling capacity of the unit has to be corrected in accordance with the length of refrigerant piping —
the distance between the indoor unit and the outdoor unit.

7.2.1 25/35 Class


(R-32)
(%)
Capacity correction factor 100

90

80 Range of the refrigerant


additional charge

5 10 15 20 (m)

Piping length

7.2.2 50/60 Class


(R-32)
(%)
100
Capacity correction factor

90

80
Range of the refrigerant additional
charge

5 10 15 20 25 30 (m)

Piping length

7.2.3 71 Class
(R-32)
(%)
100
Capacity correction factor

90

80
Range of the refrigerant
additional charge

5 10 15 20 25 30 (m)

Piping length

Note: The graphs show the factor when additional refrigerant of the proper quantity is charged.

Split Type Air Conditioners FTKZ-V Series 17


Operation Limit EDTVN042125

8. Operation Limit
RKZ25/35/50/60/71VVMV

4D073983S

18 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Sound Level

9. Sound Level
9.1 Measuring Location

Indoor Unit Outdoor Unit

1m 1m

0.8 m
MICROPHONE

MICROPHONE

Notes: 1. Operation sound is measured in an anechoic chamber.


2. The operation sound measuring method is based on JIS standard.

Split Type Air Conditioners FTKZ-V Series 19


Sound Level EDTVN042125

9.2 Indoor Unit


FTKZ25VVMV FTKZ35VVMV

4D132502 4D132503

FTKZ50VVMV FTKZ60VVMV

4D132505 4D133033

20 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Sound Level

FTKZ71VVMV

4D132506

9.3 Outdoor Unit


RKZ25VVMV RKZ35VVMV

4D132508 4D132509

Split Type Air Conditioners FTKZ-V Series 21


Sound Level EDTVN042125

RKZ50VVMV RKZ60VVMV

4D132511 4D133034

RKZ71VVMV

4D132512

22 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Electric Characteristics

10. Electric Characteristics

Unit Combination Power Supply Compressor OFM IFM


Indoor Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA
50 - 220 1.60 0.40 0.31
Max. 50 Hz, 264 V
50 - 230 1.50 0.39 0.30
Min. 50 Hz, 198 V
FTKZ25VVMV RKZ25VVMV 50 - 240 6.8 15.0 36 1.40 28 0.38 30 0.29
60 - 220 Max. 60 Hz, 253 V 1.60 0.40 0.31
60 - 230 Min. 60 Hz, 198 V 1.50 0.39 0.30
50 - 220 3.20 0.40 0.32
50 - 230 Max. 50 Hz, 264 V 3.00 0.38 0.30
Min. 50 Hz, 198 V
FTKZ35VVMV RKZ35VVMV 50 - 240 6.8 15.0 57 2.80 28 0.36 30 0.28
60 - 220 Max. 60 Hz, 253 V 3.20 0.40 0.32
60 - 230 Min. 60 Hz, 198 V 3.00 0.38 0.30
50 - 220 5.60 0.42 0.39
Max. 50 Hz, 264 V
50 - 230 Min. 50 Hz, 198 V 5.30 0.39 0.36
FTKZ50VVMV RKZ50VVMV 50 - 240 11.5 15.0 74 5.10 50 0.36 80 0.33
60 - 220 Max. 60 Hz, 253 V 5.60 0.42 0.39
60 - 230 Min. 60 Hz, 198 V 5.30 0.39 0.36
50 - 220 6.70 0.51 0.50
50 - 230 Max. 50 Hz, 264 V 6.40 0.48 0.48
Min. 50 Hz, 198 V
FTKZ60VVMV RKZ60VVMV 50 - 240 11.5 15.0 74 6.30 50 0.45 80 0.45
60 - 220 Max. 60 Hz, 253 V 6.70 0.51 0.50
60 - 230 Min. 60 Hz, 198 V 6.40 0.48 0.48
50 - 220 9.30 0.51 0.51
50 - 230 Max. 50 Hz, 264 V 9.00 0.48 0.48
Min. 50 Hz, 198 V
FTKZ71VVMV RKZ71VVMV 50 - 240 12.0 15.0 96 8.90 50 0.45 80 0.45
60 - 220 Max. 60 Hz, 253 V 9.30 0.51 0.51
60 - 230 Min. 60 Hz, 198 V 9.00 0.48 0.48

Symbols: Notes:
MCA : Min. circuit amps (A) 1. RLA is based on the following conditions.
Indoor temp. 27°CDB / 19°CWB
MFA : Max. fuse amps (A) Outdoor temp. 35°CDB.
RHz : Rated Operating Frequency (Hz) 2. Maximum allowable voltage variation between phases is 2%.
3. Select wire size based on the larger value of MCA.
RLA : Rated load amps (A) 4. Instead of fuse, use circuit breaker.
OFM : Outdoor fan motor 5. Be sure to install an earth leak detector.
(This unit uses an inverter, which means that an earth leak
IFM : Indoor fan motor detector capable of handling high harmonics must be used in
W : Fan motor rated output (W) order to prevent malfunctioning of the earth leak detector.)
FLA : Full load amps (A)
3D133109A

Split Type Air Conditioners FTKZ-V Series 23


Installation Manual EDTVN042125

11. Installation Manual


11.1 25/35 Class

24 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Installation Manual

Split Type Air Conditioners FTKZ-V Series 25


Installation Manual EDTVN042125

26 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Installation Manual

Split Type Air Conditioners FTKZ-V Series 27


Installation Manual EDTVN042125

28 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Installation Manual

Split Type Air Conditioners FTKZ-V Series 29


Installation Manual EDTVN042125

30 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Installation Manual

Split Type Air Conditioners FTKZ-V Series 31


Installation Manual EDTVN042125

32 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Installation Manual

3P620953-15F

Split Type Air Conditioners FTKZ-V Series 33


Installation Manual EDTVN042125

11.2 50/60/71 Class

34 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Installation Manual

Split Type Air Conditioners FTKZ-V Series 35


Installation Manual EDTVN042125

36 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Installation Manual

Split Type Air Conditioners FTKZ-V Series 37


Installation Manual EDTVN042125

38 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Installation Manual

Split Type Air Conditioners FTKZ-V Series 39


Installation Manual EDTVN042125

40 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Installation Manual

Split Type Air Conditioners FTKZ-V Series 41


Installation Manual EDTVN042125

42 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Installation Manual

3P620953-16F

Split Type Air Conditioners FTKZ-V Series 43


Operation Manual EDTVN042125

12. Operation Manual


12.1 English
12.1.1 25/35 Class

44 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 45


Operation Manual EDTVN042125

46 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 47


Operation Manual EDTVN042125

48 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 49


Operation Manual EDTVN042125

50 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 51


Operation Manual EDTVN042125

52 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 53


Operation Manual EDTVN042125

54 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 55


Operation Manual EDTVN042125

56 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 57


Operation Manual EDTVN042125

58 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 59


Operation Manual EDTVN042125

60 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 61


Operation Manual EDTVN042125

62 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 63


Operation Manual EDTVN042125

64 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 65


Operation Manual EDTVN042125

66 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 67


Operation Manual EDTVN042125

68 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 69


Operation Manual EDTVN042125

70 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 71


Operation Manual EDTVN042125

72 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 73


Operation Manual EDTVN042125

74 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 75


Operation Manual EDTVN042125

76 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 77


Operation Manual EDTVN042125

78 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 79


Operation Manual EDTVN042125

80 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 81


Operation Manual EDTVN042125

82 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 83


Operation Manual EDTVN042125

EN_3P620957-13G

84 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

12.1.2 50/60/71 Class

Split Type Air Conditioners FTKZ-V Series 85


Operation Manual EDTVN042125

86 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 87


Operation Manual EDTVN042125

88 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 89


Operation Manual EDTVN042125

90 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 91


Operation Manual EDTVN042125

92 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 93


Operation Manual EDTVN042125

94 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 95


Operation Manual EDTVN042125

96 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 97


Operation Manual EDTVN042125

98 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 99


Operation Manual EDTVN042125

100 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 101


Operation Manual EDTVN042125

102 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 103


Operation Manual EDTVN042125

104 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 105


Operation Manual EDTVN042125

106 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 107


Operation Manual EDTVN042125

108 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 109


Operation Manual EDTVN042125

110 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 111


Operation Manual EDTVN042125

112 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 113


Operation Manual EDTVN042125

114 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 115


Operation Manual EDTVN042125

116 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 117


Operation Manual EDTVN042125

118 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 119


Operation Manual EDTVN042125

120 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 121


Operation Manual EDTVN042125

122 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 123


Operation Manual EDTVN042125

124 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

EN_3P620957-14G

Split Type Air Conditioners FTKZ-V Series 125


Operation Manual EDTVN042125

12.2 Vietnamese
12.2.1 25/35 Class

126 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 127


Operation Manual EDTVN042125

128 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 129


Operation Manual EDTVN042125

130 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 131


Operation Manual EDTVN042125

132 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 133


Operation Manual EDTVN042125

134 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 135


Operation Manual EDTVN042125

136 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 137


Operation Manual EDTVN042125

138 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 139


Operation Manual EDTVN042125

140 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 141


Operation Manual EDTVN042125

142 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 143


Operation Manual EDTVN042125

144 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 145


Operation Manual EDTVN042125

146 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 147


Operation Manual EDTVN042125

148 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 149


Operation Manual EDTVN042125

150 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 151


Operation Manual EDTVN042125

152 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 153


Operation Manual EDTVN042125

154 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 155


Operation Manual EDTVN042125

156 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 157


Operation Manual EDTVN042125

158 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 159


Operation Manual EDTVN042125

160 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 161


Operation Manual EDTVN042125

162 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 163


Operation Manual EDTVN042125

164 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 165


Operation Manual EDTVN042125

VN_3P620957-13G

166 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

12.2.2 50/60/71 Class

Split Type Air Conditioners FTKZ-V Series 167


Operation Manual EDTVN042125

168 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 169


Operation Manual EDTVN042125

170 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 171


Operation Manual EDTVN042125

172 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 173


Operation Manual EDTVN042125

174 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 175


Operation Manual EDTVN042125

176 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 177


Operation Manual EDTVN042125

178 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 179


Operation Manual EDTVN042125

180 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 181


Operation Manual EDTVN042125

182 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 183


Operation Manual EDTVN042125

184 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 185


Operation Manual EDTVN042125

186 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 187


Operation Manual EDTVN042125

188 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 189


Operation Manual EDTVN042125

190 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 191


Operation Manual EDTVN042125

192 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 193


Operation Manual EDTVN042125

194 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 195


Operation Manual EDTVN042125

196 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 197


Operation Manual EDTVN042125

198 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 199


Operation Manual EDTVN042125

200 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 201


Operation Manual EDTVN042125

202 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 203


Operation Manual EDTVN042125

204 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

Split Type Air Conditioners FTKZ-V Series 205


Operation Manual EDTVN042125

206 Split Type Air Conditioners FTKZ-V Series


EDTVN042125 Operation Manual

VN_3P620957-14G

Split Type Air Conditioners FTKZ-V Series 207


Optional Accessories EDTVN042125

13. Optional Accessories


13.1 Indoor Unit

Manual No.
Option Name Model Name
Installation Manual Operation Manual
Wiring adaptor for timer clock / remote controller1 3 4
1 (normal open pulse contact / normal open contact) KRP413BB1S 3P248024-2H —

2 Central remote controller 2 DCS302CA61 2P162816-1 3P124623-8D


3 Unified ON/OFF controller 2 DCS301BA61 1P162827-1A 2P167410-1
4 Schedule timer 2 DST301BA61 3P162015-1A 3P124623-5C

5 Interface adaptor for DIII-NET 1 4 KRP928BB2S 3P248024-1H —


(residential air conditioner) 3P248024-3D
6 Air quality filter (enzyme blue / PM2.5) (without frame) BAFP094A43 — —
7 Deodorizing filter (enzyme blue) (without frame) 5 BAFP094A41 — —
8 Titanium apatite deodorizing filter (without frame) KAF970A46 — —
9 Dust collection filter (PM2.5) (without frame) BAFP046A41 — —
10 Remote controller loss prevention with chain KKF910A4 — —
11 S21 conversion connector KER087A41 — —

Notes: 1 S21 conversion connector (KER087A41) is required.


2 An interface adaptor (KRP928BB2S) is also required for each indoor unit.
3 Timer clock and other devices ; obtained locally.
4 Wireless LAN adaptor (built-in) needs to be set ‘OFF’ when Wiring adaptor for timer clock /
remote controller (KRP413BB1S) or Interface adaptor for DIII-NET (KRP928BB2S) is connected.
5 Standard accessory

13.2 Outdoor Unit

Manual No.
Option Name Model Name
Installation Manual Operation Manual
1 Air direction adjustment grille KPW937F4 3P561128-1 —
2 Drain plug KKP937A4 — —

208 Split Type Air Conditioners FTKZ-V Series


Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

Specifications, designs and other content appearing in this brochure are current as of February 2021 but subject to change without notice.