OPERATING MANUAL
FOR
Manufactured by:
AIM
To draw the performance characteristics of Singe Stage Centrifugal Pump Test Rig.
EQUIPMENT
Single Stage Centrifugal Pump
D.C. Motor (1HP)
Centrifugal Pump
Control Valves
Pressure Gauge
Vaccume Gauge
Sump Tank
Measuring Tank
Speed Controller
Digital watt meter
Digital RPM Indicator
SPECIFICATION :
Pressure Gauge : 0 to 4kg/cm2
Vacuum Gauge : 760 mm/Hg
D.C. Motor : 1HP
Motor Speed : 3000 rpm
Centrifugal Pump : Kirlosker Make
Measuring Tank : 225 Liter
Area of Measuring Tank : 0.3 x 0.6 = 0.180 m2
Digital Wattmeter : 4000 watt
2
DESCRIPTION
The present experiment setup consists of a Single Stage Centrifugal Pump. Suction
pipe is connected to the sump tank and suction pressure can be measured by using
suction gauge fitted on it. Discharge pressure can be measured by pressure gauge
fitted on the discharge pipe. The discharge is measured by measuring cylinder. The
flow rate of pump is controlled by the control valve to take readings at various flow
rates.
PROCEDURE
2. Switch ‘ON’ the main and select the desired speed of pump.
3. Now for a particular value of discharge opening note down the suction and
delivery pressure.
4. Using hopper fixed at measuring tank collect water in measuring tank and
calculate discharge of water.
5. Note down the delivery head and suction head.
FORMULA
Axh
1. Discharge Q = --------
t
where
A = Area of collecting tank base (m2)
Size of Collecting tank = 0.30 m x 0.60 m = 0.18 m2
t = time sec.
BP = w Q H (Kw)
B.P.
6. pump = ------------ x 100%
I.P. Shaft
B.P.
7. overall = ------------- x 100%
I.P. Elect
4