You are on page 1of 5

SCOPE OF SHT/SHTS

APPLICATION
기술 표준
ALL 1/4
ENGINEERING STANDARD
ESTABLISHED SPEC No.
POLYMERIC
MATERIAL SPECIFICATION
MATERIALS MS 300-54
RESEARCH TEAM
TITLE:

STANDARD TEST METHOD – FOGGING

CONTENTS

1. SCOPE

2. OBJECTS PARTS

3. TEST STANDARD CONDITION

4. SAMPLING of SPECIMEN

5. TEST METHOD

6. OTHERS

ISSURE of SPECIFICATION
EMS20065 ALL Aug.14,`02 T.S Lee
(SAME AS EMSR0149)
SYM EO No. DESCRIPTION OF CHANGE REV.PAGE REV.DATE REV.BY
REFERENCE CHECKED
ESTABLISHMENT
기 술 표 준 규격번호 페이지
(SPEC NO) MS 300-54 (SHT/SHTS) 2/4
ENGINEERING STANDARD

PREPARED BY APPROVED
ORIGINAL FILED AT BY BY

IPIS J.Y
(ES/MS MANAGEMENT T.S Maeng Y.S
SYSTEM) Lee Aug/09/`02 Lim
Aug/09/`02 Aug/13/02
1F-SG-00016 HYUNDAI ·KIA
MOTOR
1. SCOPE
The test method defined by this specification is fogging for interior parts.

2. OBJECT PARTS
The object parts of fogging shall be sheet, leather, cloth, mold parts, nonwoven, carpet, foam, pad
and conform to drawing.

2. TEST STANDARD CONDITION


Unless otherwise specified, the normal state of laboratory shall be at 20±2℃ and
65±5% relative humidity.

3. SAMPLING of SPECIMEN
3.1 Specimen : Specimen shall be sampling at finished product in principle.

3.2 Size and thickness of specimen


3.2.1 Specimen size : circular specimens 70 ㎜ in diameter.
3.2.2 Specimen thickness
1) Thickness shall be that of finished products
2) In case 20 mm or less thickness, specimen shall be used for test by actual thickness
of product. If the thickness of finished products exceeds 20 mm, cut uniformly to 10
mm thick.
3.3.3 In case finished products being not plane(ex: PVC mold part), specimen shall be used for
test by 10 ±2 g weight.

1F-SG-00002 현대ㆍ기아 자동차


HYUNDAI ㆍ KIA
MOTOR
기 술 표 준 규격번호 페이지
(SPEC NO) MS 300-54 (SHT/SHTS) 3/4
ENGINEERING STANDARD

4. TEST METHOD
4.1 Specimen state
Specimens shall be allowed to stand at least 24 h in the above normal state before
test.

4.2 Equipment
Use the following equipments.
1) Fogging tester :
An oil bath and breaker with cover as shown in FIG. 1.
2) Measuring instrument(Integral sphere type light transmittance meter) :
A device shown in Fig. 2.

4.3 TEST METHOD


Prepare three circular specimens 70 mm in diameter. Place a specimen with its skin upward in
a breaker of the fogging tester as shown in Fig. 1.
Place a steel cover having a 40 mm diameter hole over the breaker.
Place a glass plate(fogging 1%, or less) 50 mm wide, 50 mm long, and 3 to 5 mm thick
over the hole. Heat in the oil bath at 100 ℃ for 5 h.
Remove the glass after heating and measure the fogging attached on the glass at three
locations in the center in accordance with the procedure in Table 1, using the
device(Integral sphere type light transmittance meter) shown in Fig. 2.

Table 1
Procedure Glass plate Trap fix Standard Read on
fix white plate fix Galvanometer Measurement
1 No No Yes T1(set to 100) Incident light quantity
2 Yes No Yes T2 Total transmitted light quantity
3 No Yes No T3 Scattered light quantity through
device
4 Yes Yes No T4 Scattered light quantity through
device and glass

1F-SG-00002 현대ㆍ기아 자동차


HYUNDAI ㆍ KIA
MOTOR
기 술 표 준 규격번호 페이지
(SPEC NO) MS 300-54 (SHT/SHTS) 4/4
ENGINEERING STANDARD

Calculate the fogging by the following formula, using the average of measurements at three
locations per specimen. The average of three specimens shall be considered as the result.
T4 T3
Fogging(%) = { - } ×100
T2 T1

Fig 1

Fig 2

5. OTHERS

1F-SG-00002 현대ㆍ기아 자동차


HYUNDAI ㆍ KIA
MOTOR
기 술 표 준 규격번호 페이지
(SPEC NO) MS 300-54 (SHT/SHTS) 5/4
ENGINEERING STANDARD

If there is any doubt on this specification, contacts shall be made to Polymeric


Materials Research Team Of Research & Development division for Hyundai Motor Company
& Kia Motors Corporation.

1F-SG-00002 현대ㆍ기아 자동차


HYUNDAI ㆍ KIA
MOTOR

You might also like