You are on page 1of 24

Clogging Indicators

Clogging indicators are devices that check the life time of the filter elements. MP Filtri can supply indicators of the following designs:
They measure the pressure drop through the filter element directly connected - Vacuum switches and gauges
to the filter housing. - Pressure switches and gauges
These devices trip when the clogging of the filter element causes a pressure drop - Differential pressure indicators
increasing across the filter element.
Filter elements are efficient only if their Dirt Holding Capacity is fully exploited. These type of devices can be provided with a visual, electrical or both signals.
This is achieved by using filter housings equipped with clogging indicators. The electronic differential pressure clogging indicator is also available.
The indicator is set to alarm before the element becomes fully clogged. It provides both analogical 4-20 mA output and digital warning (75% of clogging)
and alarm (clogging) outputs.
Clogging indicators

Clogging indicators

OUT OUT OUT

2 2
1 1
3 3

Suitable indicator types OUT OUT OUT

2 2
1 1
3 3
IN IN IN
OUT OUT OUT
VACUUM INDICATORS
Vacuum indicators are used on the Suction line to check the efficiency 1
2
1
2
of the filter element. 3 3

They measure the pressure downstream of the filter element. IN IN IN


Standard items are produced with R 1/4” EN 10226 connection.
Available products with R 1/8” EN 10226 to be fitted on MPS series.
IN IN IN

OUT OUT OUT

OUT 2
OUT 2
OUT
1 1
BAROMETRIC INDICATORS 3 3

Pressure indicators are used on the Return line to check the


IN IN IN
efficiency of the filter element. OUT OUT OUT
They measure the pressure upstream of the filter element. 2 2
1 1
Standard items are produced with R 1/8” EN 10226 connection. 3 3

IN IN IN
2 2
1 1
3 3

IN IN IN

DIFFERENTIAL INDICATORS OUT OUT OUT OUT


Differential indicators are used on the Pressure line to check the
efficiency of the filter element. 2
They measure the pressure upstream and downstream of the 1
2
1
2 1
3
3 3
filter element (differential pressure). OUT OUT OUT
Standard items are produced with special connection G 1/2” size.
Also available in Stainless Steel models.
IN IN 2
IN 2
IN 1
2
OUT 1 OUT 1 OUT 3
3 3

2
2 2 1
IN 1 IN 1 IN 3
3 3

IN IN IN

1 Clogging Indicators
VACUUM INDICATORS

12

12
12
Dimensions
R R

VE*50 Hydraulic symbol Materials


- Body: Brass
Electrical Vacuum Indicator
- Base: Black Nylon
R Ordering code 2
- Contacts: Silver
1 1 2
EN 10226 - R1/4” VE A 21 A A 50 P01 3
- Seal: NBR
EN 10226 - R1/8” VE B 21 A A 50 P01
Technical data
- Vacuum setting: -0.21 bar ±10%
- Max working pressure: 4 10 bar 4
- Proof pressure: 15 bar
Electrical symbol
- Working temperature: From -25 °C to +80 °C
- Compatibility with fluids: Mineral oils, Synthetic fluids
3 2 3 HFA, HFB, HFC according to ISO 2943 3
1

- Degree of protection: 1 IP65 according to EN 60529

77
77

1 3 1

73
2 2 2
Electrical data
77
77

73
5
- Electrical connection: EN 175301-803
- Resistive load: 5 A / 14 Vdc
A/F 27 4 A / 30 Vdc
Max tightening 5 A / 125 Vac
12

GREEN RED GREE

12
12

2 LAMP LAMP LAMP


torque: 25 N∙m 1 2 4 A / 250 Vac
1
3 - Available Atex product: II 1GD Ex ia IIC Tx Ex ia IIIC Tx °C X
12

R R R

12
12

2 - CE certification1
1
3 2
R R R
VL*51 - VL*52 - VL*53 Hydraulic symbol Materials
3
4
- Body: Brass
Electrical/Visual Vacuum Indicator 5
- Base: Transparent Nylon
R Ordering code 2 - Contacts: Brass - Nylon
EN 10226 - R1/4” VL A 21 A A xx P01 1 - Seal: NBR
3
EN 10226 - R1/8” VL B 21 A A xx P01
Technical data
4 4
- Vacuum setting: -0.21 bar ±10%
Electrical symbol - Max working pressure: 10 bar
- Proof pressure: 15 bar
3 4 3 - Working temperature:4 From3 -25 °C to +80 °C
1
GREEN
1
RED
- Compatibility with fluids: Mineral
1 oils, Synthetic fluids
2
LAMP
2
LAMP
HFA,2 HFB, HFC according to ISO 2943
- Degree of protection: 3 IP65 according to EN 60529
77

3 3
73

2 5
1
1 1 1 1
3 Electrical data 2
77

73

2 2 2
- Electrical connection:
3 EN 175301-803
GREEN RED GREEN RED
LAMP LAMP - Type 4 5 51 LAMP 52 LAMP 53
A/F 27 - Lamps 5 24 Vdc 110 Vdc 230 Vac
Max tightening - Resistive load: 1 A / 24 Vdc 1 A / 110 Vdc 1 A / 230 Vac
12

12

2
torque: 25 N∙m 1
GREEN RED 1 2 GREEN RED
LAMP LAMP LAMP LAMP
3
R R
12

12

R VL*71 R
Hydraulic symbol Materials
- Body: Brass
Electrical/Visual Vacuum Indicator
- Base: Black Nylon
Connections Indicator code 2 - Contacts: Silver
EN 10226 - R1/4” VL A 21 A A 71 P01 1 - Seal: NBR
3
EN 10226 - R1/8” VL B 21 A A 71 P01
Technical data
4 4 - Vacuum setting: -0.21 bar ±10%
Electrical symbol - Max working pressure: 10 bar
- Proof pressure: 15 bar
4 3 43 - Working temperature: From -25 °C to +80 °C
1 1 - Compatibility with fluids: Mineral oils, Synthetic fluids
2 2
GREEN
LAMP
RED
LAMP HFA, HFB, HFC according to ISO 2943
- Degree of protection: IP65 according to EN 60529
73

3 35 2
1
1
1 1
3 Electrical data 2
2 2 - Electrical connection:
3 IEC 61076-2-101 D (M12)
GREEN
LAMP
RED
LAMP
5
GREEN
LAMP
RED
LAMP - Lamps 4 24 Vdc
A/F 27 - Resistive load: 5 0.4 A / 24 Vdc
Max tightening
12

torque: 25 N∙m
GREEN RED GREEN RED
LAMP LAMP LAMP LAMP

Clogging Indicators 2
VACUUM INDICATORS
Dimensions

VVA - VVB Hydraulic symbol Materials


Axial Vacuum Gauge - Case: Painted Steel
R Ordering code - Window: Transparent plastic
- Dial: Painted Steel
ø43

EN 10226 - R1/4” V VA 16 P01


- Pointer: Painted Aluminium
ø43

EN 10226 - R1/8” V V B 16 P01


Dial scale - Pressure connection: Brass
- Pressure element: Bourdon tube Cu-alloy soft soldered
Red
R
Technical data
18 ø43

R
A/F 14 Yellow - Max working pressure: Static: 7 bar
18ø43

A/F 14 Fluctuating: 6 bar


Short time: 10 bar
Green - Working temperature: From -40 °C to +60 °C
24

cmHg
R - Compatibility with fluids: Mineral oils, Synthetic fluids
24

R HFA, HFB, HFC according to ISO 2943


A/F 14 - Accuracy: Class 2.5 according to EN 13190
Conversion to SI units
18

A/F 14
[cmHg] [bar] - Degree of protection: IP31 according to EN 60529
18

-12 -0.16
24

-18 -0.24
24

2
-76 -1.01
1 1 2

VVR - VVS 3
Hydraulic symbol Materials
Radial Vacuum Gauge - Case: Painted Steel
R A/F Ordering code - Window: Transparent plastic
EN 10226 - R1/4” 14 V V R 16 P01 - Dial: Painted Steel
EN 10226 - R1/8” 11 V V S 16 P01 - Pointer: Painted Aluminium
Dial scale - Pressure connection: Brass
Red 2 - Pressure element: Bourdon tube Cu-alloy soft soldered
1
3 Technical data
ø53

Yellow - Max working pressure: Static: 7 bar


ø53

Fluctuating: 6 bar
Short time: 10 bar
Green - Working temperature: From -40 °C to +60 °C
ø53 18

A/F cmHg - Compatibility with fluids: Mineral oils, Synthetic fluids


ø53 18

HFA, HFB, HFC according to ISO 2943


R
Conversion to SI units - Accuracy: Class 2.5 according to EN 13190
R
[cmHg] [bar] - Degree of protection: IP31 according to EN 60529
2
-12 1 -0.16 1
1828

-18 3 -0.24 2
1828

2
-76 -1.01 3
1 2
R 1
4
3
R 5

DESIGNATION & ORDERING CODE


28

Series Configuration example 1: VE A 21 A A 50 P01


28

VE Electrical vacuum indicator Configuration example 2: VL B 21 A A 71 P01


VL Electrical/Visual vacuum indicator
Configuration example 3: VV R 16 P01
VV Vacuum gauge 2
1
Type VE - VL Type VV 3

A Connection EN 10226 - R1/4” A Axial connection EN 10226 - R1/4”


B Connection EN 10226 - R1/8” B Axial connection EN 10226 - R1/8”
R Radial connection EN 10226 - R1/4”
S Radial connection EN 10226 - R1/8”
Vacuum setting VE VL VV
16 0.16 bar •
21 0.21 bar 2 • •
1
1
Seals 3 VE VL VV 2

A NBR • • 3
4
Thermostat VE VL VV 5

A Without • •
Electrical connections VE VL VV
50 Connection EN 175301-803 •
51 Connection EN 175301-803, transparent base with lamps 24 Vdc • Option
52 Connection EN 175301-803, transparent base with lamps 110 Vdc • P01 MP Filtri standard
53 Connection EN 175301-803, transparent base with lamps 230 Vdc • Pxx Customized
71 Connection IEC 61076-2-101 D (M12), black base with lamps 24 Vdc •

3 Clogging Indicators
BAROMETRIC INDICATORS

10

10
10
Dimensions
EN 10226 - R1/8” EN 10226 - R1/8”

BEA*50 Hydraulic symbol Materials


Electrical Pressure Indicator - Body: Brass
- Base: Black Nylon
2
Settings Ordering code - Contacts: Silver
1 1 2
1.5 bar ±10% BE A 15 H A 50 P01 3
- Seal: HNBR
2.0 bar ±10% BE A 20 H A 50 P01
Technical data
- Max working pressure: 40 bar
- Proof pressure: 4
60 bar 4
- Working temperature: From -25 °C to +80 °C
Electrical symbol
- Compatibility with fluids: Mineral oils, Synthetic fluids
2
HFA, HFB, HFC according to ISO 2943
77
3
1 - Degree of protection: 3 IP65 according to EN 60529 3

73
77

1000
1 3 1 1

2 Electrical data 2 2
- Electrical connection: EN 175301-803
- Resistive load: 5 A / 14 Vdc
A/F 27 4 A / 30 Vdc
Max tightening 5 A / 125 Vac
10

10
10

torque: 25 N∙m 4 A / 250 Vac

55
- Available Atex product: II 1GD Ex ia IIC Tx Ex ia IIIC Tx °C X
77

EN 10226 - R1/8” EN 10226 - R1/8”


- CE certification EN 10226 - R1/8”
2
1
1
3 2

14
BEM*41 Hydraulic symbol Materials
3
4
- Body: Brass EN 10226 - R1/8”
10

Electrical Pressure Indicator 5


- Base:
EN 10226 - R1/8” Black Nylon
Settings Ordering code 2
- Contacts: Silver
1 1 2
1.5 bar ±10% BE M 15 H A 41 P01 3
- Seal: HNBR
2.0 bar ±10% BE M 20 H A 41 P01
4 Technical data 4
- Max working pressure: 40 bar
- Proof pressure: 60 bar
1000

Electrical symbol
3 3 - Working temperature:3 From -25 °C to +80 °C
GREY 1
- Compatibility with fluids:
1
Mineral oils, Synthetic fluids
1
HFA, HFB, HFC according to ISO 2943
BLACK 2 2
2
1
- Degree of protection: 2 IP67 according to EN 60529
BROWN 3
Electrical data
55

YELLOW / GREEN
- Electrical connection: Four-core cable
77

- Resistive load: 5 A / 14 Vdc


4 A / 30 Vdc
5 A / 125 Vac
A/F 27
14

4 A / 250 Vac
Max tightening
- CE certification
torque: 25 N∙m
ENOn10226 - R1/8”
request this indicator can be provided with main connectors
10

EN 10226 - R1/8” 2 in use for wirings.1


1
3 2

BET*10 3
81

79

Hydraulic symbol Materials


4
Electrical Pressure Indicator - Body: Brass
5
- Base: Black Nylon
2
Settings Ordering code - Contacts: Silver
1 1 2
2.0 bar ±10% BE T 20 H F 10 P01 3
- Seal: HNBR
2.5 bar ±10% BE T 25 H F 10 P01
GREY
9

Technical data
BLACK - Max working pressure: 10 bar
EN 10226 - R1/8” EN 10226 - R1/8”
BROWN - Proof pressure: 15 bar
- Working temperature: From -25 °C to +100 °C
YELLOW / GREEN Electrical symbol
- Compatibility with fluids: Mineral oils, Synthetic fluids
2
HFA, HFB, HFC according to ISO 2943
N.C.
1
N.C. - Degree of protection: IP65 according to EN 60529
3 Thermal lockout
81

79

C C
Electrical data
A/F 27 - Electrical connection: AMP Superseal series 1.5
Max tightening - Resistive load: 0.5 A / 48 Vdc
torque: 25 N∙m - Thermostat condition: Open up to 30 °C
- CE certification
9

EN 10226 - R1/8” EN 10226 - R1/8”


2
1
1
3 2
3
Clogging Indicators 4
N.C. N.C. 4
5
BAROMETRIC INDICATORS
Dimensions
71

81

79
BET*30 Hydraulic symbol Materials
Electrical Pressure Indicator - Body: Brass
- Base: Black Nylon
2
Settings Ordering code - Contacts: Silver
1 1 2
- Seal: HNBR
9

2.0 bar ±10% BE T 20 H F 30 P01

9
3
2.5 bar ±10% BE T 25 H F 30 P01
EN 10226 - R1/8” EN 10226 - R1/8” EN 10226 - R1/8”
Technical data
- Max working pressure: 10 bar
Electrical symbol - Proof pressure: 15 bar
- Working temperature: From -25 °C to +100 °C
N.C. N.C. - Compatibility with fluids:
N.C. Mineral oils, Synthetic fluids
2 Thermal lockout
HFA, HFB, HFC according to ISO 2943
C 1 - Degree of protection: IP65 according to EN 60529
C C
79

3
A/F 27 Electrical data
Max tightening - Electrical connection: Deutsch DT-04-2-P
torque: 25 N∙m - Resistive load: 0.5 A / 48 Vdc
- Thermostat condition: Open up to 30 °C
- CE certification
9

8” EN 10226 - R1/8”

2
1
1
71

81
3 2
N.C.
BET*50 Hydraulic symbol
3
4
Materials
Electrical Pressure Indicator 5
- Body: Brass
C - Base: Black Nylon
2
Settings Ordering code1 2
- Contacts: Silver
1
2.0 bar ±10% BE T 20 H F 50 P01 - Seal: HNBR
9

9
3
2.5 bar ±10% BE T 25 H F 50 P01
EN 10226 - R1/8”Technical data EN 10226 - R1/8”
- Max working pressure: 10 bar
Electrical symbol - Proof pressure: 15 bar
- Working temperature: From -25 °C to +100 °C
N.C. - Compatibility with fluids: Mineral
N.C.
oils, Synthetic fluids
2 Thermal lockout
HFA, HFB, HFC according to ISO 2943
1 - Degree of protection: IP65 according to EN 60529
71

81

79

C C
3

A/F 27 Electrical data


Not - Electrical connection: EN 175301-803
Max tightening
77

73
77

connected
torque: 25 N∙m - Resistive load: 0.5 A / 48 Vdc
- Thermostat condition: Open up to 30 °C
- CE certification
9

2
EN 10226 - R1/8” 1
EN 10226 2- R1/8”
1
EN 10226 - R1/8”
3
10

10
10

2
1
1
3 2
N.C. EN 10226 - R1/8” EN 102263 - R1/8” EN 10226 - R1/8”
BL*51 - BL*52 - BL*53 N.C.
Hydraulic symbol 4
Materials
N.C.

Electrical/Visual
C Pressure Indicator 5
- Body: Brass
C C
- Base: Transparent Nylon
Settings Ordering code 2 - Contacts: Silver
1.5 bar ±10% BL A 15 H A xx P01 1 - Seal: HNBR
2.0 bar ±10% BL A 20 H A xx P01 3

Technical data
- Max working pressure: 40 bar
Electrical symbol - Proof pressure: 60 bar
- Working temperature: From -25 °C to +80 °C
4 4
- Compatibility with fluids: Mineral oils, Synthetic fluids
GREEN RED
HFA, HFB, HFC according to ISO 2943
LAMP LAMP
- Degree of protection: IP65 according to EN 60529
3 3 3
77

73

2
1 1 1 Electrical data 1 1
3 - Electrical connection:
2 EN 175301-803
2 2 2
- Type 3 51 52 53
- Lamps 4 24 Vdc 110 Vdc 230 Vac
A/F 27 - Resistive load: 5 1 A / 24 Vdc 1 A / 110 Vdc 1 A / 230 Vac
Max tightening
10

10

torque: 25 N∙m

- R1/8” EN 10226 - R1/8” EN 10226 - R1/8”

5 Clogging Indicators
77

73
BAROMETRIC INDICATORS 1
2
1 2
3
Dimensions
10

10
EN 10226 - R1/8” EN 10226 - R1/8”
BL*71 Hydraulic symbol Materials
Electrical/Visual Pressure Indicator - Body: Brass
- Base: Black Nylon
Settings Ordering code 2
- Contacts: Silver
1.5 bar ±10% BL A 15 H A 71 P01 1 - Seal: HNBR
2.0 bar ±10% BL A 20 H A 71 P01 3
Technical data
- Max working pressure: 40 bar
Electrical symbol - Proof pressure: 60 bar
- Working temperature: From -25 °C to +80 °C
4 4 - Compatibility with fluids: Mineral oils, Synthetic fluids
HFA, HFB, HFC according to ISO 2943
73

GREEN RED
LAMP LAMP - Degree of protection: IP65 according to EN 60529
3 3
2
Electrical data 1
1 1 1
3
- Electrical connection:
2
IEC 61076-2-101 D (M12)
2
A/F 27
2 - Lamps: 3
24 Vdc
Max tightening - Resistive load: 4 0.4 A / 24 Vdc
10

torque: 25 N∙m 5

” EN 10226 - R1/8”

BVA Hydraulic symbol Materials


Axial Pressure Gauge - Case: Painted Steel
- Window: Transparent plastic
Settings Ordering code - Dial: Painted Steel
1.4 bar ±10% BV A 14 P01 - Pointer: Painted Aluminium
2.5 4bar ±10% BV A 25 P01 - Pressure connection: Brass
Dial scale - Pressure element: Bourdon tube Cu-alloy sof t soldered
BV A 14 P01
Red Technical data
43

Yellow
43
ø 43 øøø43

3
- Max working pressure: Static: 7 bar
1
Fluctuating: 6 bar
2
Green Short time: 10 bar
- Working temperature: From -40 °C to +60 °C
bar
EN 10226
EN 10226 - R1/8” - Compatibility with fluids: Mineral oils, Synthetic fluids
EN 10226 -- R1/8”
R1/8”
HFA, HFB, HFC according to ISO 2943
A/F 11 BV A 25 P01 - Accuracy: Class 2.5 according to EN 13190
15

EN 10226 - A/F
R1/8”
A/F 11
15

11
15

Yellow Red - Degree of protection: IP31 according to EN 60529


A/F 11
25
25 15
25

Green
2
1 1 2
25

bar 3

BVR Hydraulic symbol Materials


Radial Pressure Gauge - Case: Painted Steel
- Window: Transparent plastic
Settings Ordering code 2 - Dial: Painted Steel
1.4 bar ±10% BV R 14 P01 1 - Pointer: Painted Aluminium
2.5 bar ±10% BV R 25 P01 3 - Pressure connection: Brass
Dial scale - Pressure element: Bourdon tube Cu-alloy sof t soldered
BV R 14 P01
Red Technical data
Yellow
- Max working pressure: Static: 7 bar
Fluctuating: 6 bar
43
43
16 ø 43 øøø43

Short time: 10 bar


Green - Working temperature: From -40 °C to +60 °C
bar
2
- Compatibility with fluids: Mineral oils, Synthetic fluids
A/F 11
11 1
1 HFA, HFB, HFC according to ISO 2943
16

A/F
16

A/F 11 - Accuracy: 2 Class 2.5 according to EN 13190


BV R 25 P01
3
EN 10226
EN 10226 - R1/8” - Degree of protection: IP31 according to EN 60529
EN 10226 -- R1/8”
3
R1/8” Yellow Red
16

A/F 11 4

EN 10226 - R1/8” 5
Green 2
23

1 1 2
23
23

3
bar
23

Clogging Indicators 6
BAROMETRIC INDICATORS
Dimensions

BVP - BVQ Hydraulic symbol Materials


Visual Pressure Indicator - Body: Brass
- Cover / internal parts: Nylon
Setting Ordering code - Caps: VMQ
BV P 15 H P01 - Seal: HNBR
1.5 bar ±10%
BV Q 15 H P01
BV P 20 H P01 Technical data
2.0 bar ±10% - Reset: BVP - Automatic reset
BV Q 20 H P01
BVQ - Manual reset
- Max working pressure: 10 bar
- Proof pressure: 15 bar
- Working temperature: From -25 °C to +80 °C
2
- Compatibility with fluids: Mineral oils, Synthetic fluids
1 1 2
3
HFA, HFB, HFC according to ISO 2943
- Degree of protection: IP45 according to EN 60529
55

A/F 27
Max tightening Signals
14

55

torque: 25 N∙m
2
EN 10226 - R1/8” 1 Absence of pressure Presence of pressure Clogged filter element
(no3 indicator) (green button rises gradually) (red button risen)
14

EN 10226 - R1/8”
R1/8”

2
1
1
3 2
3
DESIGNATION & ORDERING CODE 4

Series Configuration example 1: BE 5 M 15 H A 41 P01


BE Electrical pressure indicator Configuration example 2: BL A 20 H A 71 P01
BL Electrical/Visual pressure indicator
Configuration example 3: BV R 14 P01
BV Visual pressure indicator
Configuration example 4: BV P 20 H P01

Type BE BL BV
A Standard type • • A Axial connection pressure gauge
M With wired electrical connection • R Radial connection pressure gauge
T With thermal switch • P Visual indicator with automatic reset
Q Visual indicator with manual reset

Pressure setting BEA-BEM BET BLA BVA-BVR BVP-BVQ


14 1.4 bar •
15 1.5 bar • •
20 2.0 bar • • • •
25 2.5 bar • •
Seals BE BLA BVA-BVR BVP-BVQ
H HNBR • • •
Thermostat BEA-BEM BET BLA BV
A Without • •
F With •

Electrical connections BEA BEM BET BL BV


10 Connection AMP Superseal series 1.5 •
30 Connection Deutsch DT-04-2-P •
41 Connection via four-core cable •
50 Connection EN 175301-803 • •
51 Connection EN 175301-803, transparent base with lamps 24 Vdc •
Option
52 Connection EN 175301-803, transparent base with lamps 110 Vdc • P01 MP Filtri standard
53 Connection EN 175301-803, transparent base with lamps 230 Vdc • Pxx Customized
71 Connection IEC 61076-2-101 D (M12), black base with lamps 24 Vdc •

7 Clogging Indicators
DIFFERENTIAL INDICATORS
Dimensions

DEA*50 Hydraulic symbol Materials


Electrical Differential Indicator - Body: Brass
- Base: Black Nylon
2
Settings Ordering code - Contacts: Silver
1 1 2
1.2 bar ±10% DE A 12 x A 50 P01 3
- Seal: HNBR - FPM
2.0 bar ±10% DE A 20 x A 50 P01
5.0 bar ±10% DE A 50 x A 50 P01 Technical data
7.0 bar ±10% DE A 70 x A 50 P01 - Max working pressure: 420 bar
4
9.5 bar ±10% DE A 95 x A 50 P01 - Proof pressure: 630 bar
- Burst pressure: 1260 bar
Electrical symbol
- Working temperature: From -25 °C to +110 °C
3
2
- Compatibility with fluids: Mineral oils, Synthetic
3 fluids
1 1 HFA, HFB, HFC1 according to ISO 2943
3 - Degree protection: IP66 according to EN 60529
2 2
IP69K according to ISO 20653
53

53

50
Electrical data
- Electrical connection: EN 175301-803
A/F 30 - Resistive load: 0.2 A / 115 Vdc
Max tightening
torque: 65 N∙m

2
1
1
3 2

DEH*48 Connection diagram Materials


3
4
Hazardous Area - Body: AISI 316 Stainless steel
5
Electronic Differential Indicator - Contacts: Rhodium (tungsten optional)
Settings Ordering code Red Black - Seal: MFQ - FPM
5.0 bar ±10% DE H 50 x A 48 P01
White Protection class Ex ia IIC T4/T6: Intrinsically safe
7.0 bar ±10% DE H 70 x A 48 P01
28 4 Temperature class T4 (135 °C) and T6 (85
4 °C)
M20 x 1.5
Technical data
3 3
- Max working pressure: 420 bar 3
- Working temperature: From -60 °C to +125 °C
1 1 1
- Connection type: M20 x 1.5 - 3 core polyrad cable supplied with 5 meters
2 A/F 25 mm 2 - Contact type: SPCO/SPDT (Hermetically
2 sealed - volt free contacts)
Max tightening - Compatibility with fluids: Mineral oils, Synthetic5 fluids
87.5

torque: 50 N∙m HFA, HFB, HFC according to ISO 2943


114

- Degree of protection: IP 66/67/68 according to EN 60529

Electrical data
- Certification / Approvals: - Current Ratings 24v DC 830mA - 110v AC 180mA
ATEX, IECEx, TRCU, INMETRO - Electrical Ratings Ui 30V - Li 250mA - Pi 1.3W
- Certification included
as standard

DEH*49 Connection diagram Materials


Hazardous Area - Body: AISI 316 Stainless steel
Electronic Differential Indicator - Contacts: Rhodium (tungsten optional)
Red Black - Seal: MFQ - FPM
Settings Ordering code
5.0 bar ±10% DE H 50 x A 49 P01 White Protection class Ex d IIC T4/T6: Flameproof
7.0 bar ±10% DE H 70 x A 49 P01
28 Temperature class T4 (135 °C) and T6 (85 °C)
Green
1/2” NPT Technical data
- Max working pressure: 420 bar
- Working temperature: From -60 °C to +120 °C : ATEX, IECEx, TRCU, INMETRO
From -60 °C to +105 °C : UL/CSA
- Connection type: 1/2” NPT - 3 core polyrad cable supplied with 5 meters
A/F 25 mm - Contact type: SPCO/SPDT (Hermetically sealed - volt free contacts)
Max tightening - Compatibility with fluids: Mineral oils, Synthetic fluids
87.5

torque: 50 N∙m HFA, HFB, HFC according to ISO 2943


- Certification / Approvals: - Degree of protection: IP 66/67/68 according to EN 60529
114

ATEX, IECEx, TRCU, INMETRO,


UL/CSA Class I Division 1 Electrical data
Groups A-D, - Current Ratings 24v DC 830mA - 110v AC 180mA
UL/CSA Class II Division 1 - Electrical Ratings Supply Voltage 24 VDC 110 VAC
Groups E-G Max switching current 830mA 180mA
- Certification included Max voltage 150 V AC/DC
as standard Power watts 20 W VA

Clogging Indicators 8
DIFFERENTIAL INDICATORS
Dimensions

DEH*70 Connection diagram Materials


Hazardous Area - Body: AISI 316 Stainless steel housing with internal
Electronic Differential Indicator Brown engineered resin switch
Settings Ordering code
1
Blue - Contacts: Rhodium
4 2
5.0 bar ±10% DE H 50 x A 70 P01 3 Black - Seal: MFQ - FPM
7.0 bar ±10% DE H 70 x A 70 P01
Protection class EX ia IIC T6: Intrinsically safe

Temperature class T6 (85 °C)


M12
Technical data
28 mm O.D. - Max working pressure: 420 bar
- Working temperature: From -20 °C to +80 °C
- Connection type: 4 pole male M12 connector - plastic
- Contact type: SPCO/SPDT (Hermetically sealed - volt free contacts)
42.5
90

A/F 25 mm - Compatibility with fluids: Mineral oils, Synthetic fluids


Max tightening HFA, HFB, HFC according to ISO 2943
torque: 50 N∙m - Degree of protection: IP 66/67 according to EN 60529
26.5

- Certification / Approvals: Electrical data


ATEX, IECEx, TRCU, INMETRO - Current Ratings 24v DC 830mA - 110v AC 180mA
- Electrical Ratings Ui 30V - Li 250mA - Pi 1.3W

75
- Certification included

60
as standard

DEM*10 Hydraulic symbol Materials


Electrical Differential Indicator - Body: Brass
- Base: Black Nylon
Settings Ordering code 2
- Contacts: Silver
1.2 bar ±10% DE M 12 x x 110 P01 1 2
- Seal: HNBR - FPM
2.0 bar ±10% DE M 20 x x 10 P01 3

5.0 bar ±10% DE M 50 x x 10 P01 Technical data


7.0 bar ±10% DE M 70 x x 10 P01 - Max working pressure: 420 bar
9.5 bar ±10% DE M 95 x x 10 P01 - Proof pressure: 630 bar
Electrical symbol
- Burst pressure: 1260 bar
2 - Working temperature: 2 From -25 °C to +110 °C 2
Thermal lockout - Compatibility with fluids: Mineral oils, Synthetic fluids
2
HFA, HFB, HFC according to ISO 2943
flexible cable: 290 to “A”

1
1
- Degree protection: 1 IP66 according to EN 60529 1
75

3
60

Electrical data
- Electrical connection: AMP Superseal series 1.5
- Resistive load: 0.2 A / 115 Vdc
- Switching type: Normally open contacts (NC on request)
- Thermal lockout: Normally open up to 30 °C (option “F”)
A/F 28
Max tightening
75

torque: 65 N∙m
60

2
1
1
3 2 C

2 DEM*20 Hydraulic
2 symbol
3
Materials 2
4 A
Electrical1 Differential Indicator - Body: Brass
5 B
1 - Base: 1 Black Nylon
Settings Ordering code 2 - Contacts: Silver
1.2 bar ±10% DE M 12 x x 120 P01 1 2
- Seal: HNBR - FPM
2.0 bar ±10% DE M 20 x x 20 P01 3

5.0 bar ±10% DE M 50 x x 20 P01 Technical data


7.0 bar ±10% DE M 70 x x 20 P01 - Max working pressure: 420 bar
9.5 bar ±10% DE M 95 x x 20 P01 - Proof pressure: 630 bar
Electrical symbol C
- Burst pressure: 1260 bar
2 2 - Working temperature: 2 From -25 °C to +110 °C
Thermal lockout - Compatibility with fluids: Mineral oils, Synthetic fluids A
2
1
HFA, HFB, HFC according to ISO 2943 B
1 1 1
3 - Degree protection: IP66 according to EN 60529
75
60

Electrical data
- Electrical connection: AMP Time junior
- Resistive load: 0.2 A / 115 Vdc
- Switching type: Normally open contacts (NC on request)
A/F 28
Max tightening - Thermal lockout: Normally open up to 30 °C (option “F”)
torque: 65 N∙m
2
1
1
3 2
3
9 Clogging Indicators
4
5 C
DIFFERENTIAL INDICATORS
Dimensions

75
60

DEM*30 Hydraulic symbol Materials


Electrical Differential Indicator - Body: Brass
- Base: Black Nylon
Settings Ordering code 2
- Contacts: Silver
1.2 bar ±10% DE M 12 x x 30 P01
1 1 2
- Seal: HNBR - FPM
3
2.0 bar ±10% DE M 20 x x 30 P01
5.0 bar ±10% DE M 50 x x 30 P01 Technical data
7.0 bar ±10% DE M 70 x x 30 P01 - Max working pressure: 420 bar
9.5 bar ±10% DE M 95 x x 30 P01 - Proof pressure: 630 bar
Electrical symbol - Burst pressure: 1260 bar
- Working temperature:
C From -25 °C to +110 °C
2 2 2 - Compatibility with fluids: Mineral oils, Synthetic fluids
1 A HFA, HFB, HFC according to ISO 2943
3 - Degree protection:
B IP66 according to EN 60529
1 1
75

Electrical data
- Electrical connection: Deutsch DT-04-2-P
- Resistive load: 0.2 A / 115 Vdc
A/F 28 - Switching type: Normally open contacts (NC on request)
Max tightening - Thermal lockout: Normally open up to 30 °C (option “F”)
torque: 65 N∙m
2
75

1
1
3 2

DEM*35 Hydraulic symbol


3
4
Materials
Electrical Differential Indicator C
5
- Body: Brass
- Base: Black Nylon
Settings
2
Ordering code 2
A - Contacts: Silver
1.2 bar ±10% DE M 12 x x 35 P01 1 1 2
B - Seal: HNBR - FPM
2.0 bar 1±10% DE M 20 x x 35 P01 3

5.0 bar ±10% DE M 50 x x 35 P01


Technical data
7.0 bar ±10% DE M 70 x x 35 P01
- Max working pressure: 420 bar
9.5 bar ±10% DE M 95 x x 35 P01
Electrical symbol - Proof pressure: 630 bar
- Burst pressure: 1260 bar
C - Working temperature: From -25 °C to +110 °C
2 2
- Compatibility with fluids: Mineral oils, Synthetic fluids
HFA, HFB, HFC according to ISO 2943
flexible cable: 240 to “A”

A 1

B
3 - Degree protection: IP66 according to EN 60529
1
Electrical data
53

53

50

- Electrical connection: Deutsch DT-04-3-P


- Resistive load: 0.2 A / 115 Vdc
- Switching type: SPDT contact
2 - Thermal lockout: Normally open up to 30 °C (option “F”)
A/F 28 1 1 2
Max tightening 3
torque: 65 N∙m 2
1
1
3 2

DLA*51
C
- DLA*52 Hydraulic symbol Materials
3
4
Electrical/Visual
A Differential Indicator - Body: 5 Brass
- Base: Transparent Nylon
Settings B
Ordering code 2 - Contacts: Silver
1.2 bar ±10% DL A 12 x A xx P01 1 - Seal: HNBR - FPM
2.0 bar ±10% DL A 20 x A xx P01 3
5.0 bar ±10% DL A 50 x A xx P01 Technical data
7.0 bar ±10% DL A 70 x A xx P01 - Max working pressure: 420 bar
Electrical symbol
9.5 bar ±10% DL A 95 x A xx P01 - Proof pressure: 630 bar
4 4
- Burst pressure: 1260 bar
- Working temperature: From -25 °C to +110 °C
- Compatibility with fluids: Mineral oils, Synthetic fluids
3 3 3
HFA, HFB, HFC according to ISO 2943
1 1
2
- Degree protection: 1IP66 according to EN 60529
1 2IP69K according to ISO 20653
53

50

2 2 1
3 2
5
Electrical data 3
- Electrical connection:
4 EN 175301-803
A/F 30 - Type 5 51 52
Max tightening - Lamps 24 Vdc 110 Vdc
torque: 65 N∙m - Resistive load: 1 A / 24 Vdc 1 A / 110 Vdc

Clogging Indicators 10
53

50
1
2 DIFFERENTIAL INDICATORS
1 2
3
Dimensions

DLA*71 Hydraulic symbol Materials


Electrical/Visual Differential Indicator - Body: Brass
- Base: Black Nylon
Settings Ordering code 2
- Contacts: Silver
1.2 bar ±10% DL A 12 x A 71 P01 1
- Seal: HNBR - FPM
2.0 bar ±10% DL A 20 x A 71 P01 3
5.0 bar ±10% DL A 50 x A 71 P01 Technical data
7.0 bar ±10% DL A 70 x A 71 P01 - Max working pressure: 420 bar
9.5 bar ±10% DL A 95 x A 71 P01 2
- Proof pressure: 630 bar
- Burst pressure: 1260 bar
Electrical
1 symbol 1 2
3 - Working temperature: From -25 °C to +110 °C
- Compatibility with fluids: Mineral oils, Synthetic fluids
4 4
HFA, HFB, HFC according to ISO 2943
GREEN
LAMP
RED
LAMP
- Degree protection: IP65 according to EN 60529
2 1 IP69K according to ISO 20653
50

3 3 1
3 2
1 1 Electrical data 3
2 2 2 - Electrical connection:
4
IEC 61076-2-101 D (M12)
A/F 30 1 - Lamps 5 24 Vdc
5 3 - Resistive load: 0.4 A / 24 Vdc
Max tightening
torque: 65 N∙m 59 58

DLE*A50 Hydraulic symbol Materials


- Body: Brass
58

58
Electrical/Visual Differential Indicator
- Base: Black Nylon
2
Settings Ordering code - Contacts: 1 Silver
1
1.2 bar ±10% DL E 12 x A 50 P01 3 - Seal: 2 HNBR - FPM
2.0 bar ±10% DL E 20 x A 50 P01 3
5.0 bar ±10% DL E 50 x A 50 P01 Technical data 4
7.0
4 bar ±10% DL E 70 x A 50 P01 - Max working pressure:
5 420 bar
9.5 bar ±10% DL E 95 x A 50 P01 - Proof pressure: 630 bar
59 2 - Burst pressure: 58 1260 bar
3
1 1 - Working
2 temperature: From -25 °C to +110 °C
3
1
- Compatibility with fluids: Mineral oils, Synthetic fluids
HFA, HFB, HFC according to ISO 2943
2
Electrical symbol - Degree protection: IP65 according to EN 60529
5 3
Electrical data
58

58

1 - Electrical connections: EN 175301-803 1


- Resistive load: 5 A / 250 Vac
2 2 2
- Available the connector with lamps
1
3
A/F 32
Max tightening
59 torque: 95 N∙m 58

DLE*F50 Hydraulic symbol Materials


Electrical/Visual Differential Indicator - Body: Brass
- Base: Black Nylon
58

Settings Ordering code 2


3- Contacts: Silver
1.23 bar ±10% DL E 12 x F 50 P01 1 - Seal: 1 HNBR - FPM
2.01 bar ±10% DL E 20 x F 50 P01 3 2
1
5.0 bar ±10% DL E 50 x F 50 P01 Technical data 3
7.02 bar ±10% DL E 70 x F 50 P01 2 4
- Max working pressure: 420 bar
9.5 bar ±10% DL E 95 x F 50 P01 - Proof pressure:5 630 bar
58 - Burst pressure: 1260 bar
- Working temperature: From -25 °C to +110 °C
- Compatibility with fluids: Mineral oils, Synthetic fluids
HFA, HFB, HFC according to ISO 2943
- Degree protection: IP65 according to EN 60529
Electrical symbol
58

3 Electrical data
Thermal lockout - Electrical connections: EN 175301-803
- Resistive load: 5 A / 250 Vac
1
- Thermal lockout setting: +30 °C
2

A/F 32
Max tightening
torque: 95 N∙m

11 Clogging Indicators
2
1

DIFFERENTIAL INDICATORS
3

Dimensions

DTA*70 Hydraulic symbol Materials

47

39
- Body: Brass

34
Electronic Differential Indicator
2
- Internal parts: Brass - Nylon
Settings Ordering code 1 - Contacts: Silver Industry 4.0
1 READY
1.2 bar ±10% DT A 12 x x 70 3P01 2 - Seal: HNBR - FPM
2.0 bar ±10% DT A 20 x x 70 P01 3
5.0 bar ±10% DT A 50 x x 70 P01 4 Technical data
7.0 bar ±10% DT A 70 x x 70 P01 5 - Max working pressure: 420 bar
9.5 bar ±10% DT A 95 x x 70 P01 - Proof pressure: 630 bar
- Burst pressure: 1260 bar
- Compatibility with fluids: Mineral oils, Synthetic fluids
HFA, HFB, HFC according to ISO 2943
- Degree protection: IP67 according to EN 60529
Electrical symbol
Electrical data
47

39
- Electrical connection: IEC 61076-2-101 D (M12)

34
1 +24 Vdc
- Power supply: 24 Vdc
2 4 ÷ 20 mA
- Analogue output: From 4 to 20 mA
75% - N.O.
A/F 30
3 Digital output - Thermal lockout: 30 °C (all output signals stalled up to 30 °C)
Max tightening 4
100% - N.O.
Digital output
torque: 50 N∙m
5 0 Vdc

DVA Hydraulic symbol Materials


Visual Differential Indicator - Body: Brass
- Internal parts: Brass - Nylon
Settings Ordering code - Contacts: Silver
1.2
1
bar ±10% DV A 12 x P01
+24 Vdc
- Seal: HNBR - FPM
2.0 bar ±10% DV A 20 x P01
2 ÷
4 20 mA
5.0 bar ±10% DV A 50 x P01 Technical data
7.0
3 bar ±10% DV A 70 x P01
75% - N.O. - Reset: Automatic reset
9.5 bar ±10% DV A 95 x P01 - Max working pressure: 420 bar
100% - N.O.
4 - Proof pressure: 630 bar
5 0 Vdc - Burst pressure: 1260 bar
Green / Red - Working temperature: From -25 °C to +110 °C
clogging indicator 2 - Compatibility with fluids: Mineral oils, Synthetic fluids
1 2
3
1
HFA, HFB, HFC according to ISO 2943
- Degree protection: IP65 according to EN 60529
39

34

A/F 28
Max tightening
torque: 65 N∙m
2
1
3

DVM Hydraulic symbol Materials


Visual Differential Indicator - Body: Brass
- Internal parts: Brass - Nylon
Settings Ordering code - Contacts: Silver
1.2 bar ±10% DV M 12 x P01 - Seal: HNBR - FPM
2.0 bar ±10% DV M 20 x P01
5.0 bar ±10% DV M 50 x P01 2 Technical data
7.0 bar ±10% DV M 70 x P01 1 - Reset:
1
Manual reset
9.5 bar ±10% DV M 95 x P01 3 2
- Max working pressure: 420 bar
3
- Proof pressure: 630 bar
4
- Burst pressure: 1260 bar
5
Red - Working temperature: From -25 °C to +110 °C
clogging indicator 2 - Compatibility with fluids: Mineral oils, Synthetic fluids
1 1 2 HFA, HFB, HFC according to ISO 2943
3
- Degree protection: IP65 according to EN 60529
34

A/F 30
Max tightening
torque: 65 N∙m
2
1
3

Clogging Indicators 12
10
10
DIFFERENTIAL INDICATORS
Dimensions

A/F30A/F30 T2 Materials
Indicator plug - Body: Phosphatized steel
- Seal: HNBR / FPM
Seal Ordering code
HNBR T2 H
FPM T2 V

A/F 30
Max tightening
torque: 50 N∙m

DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATORS


Series Configuration example 1: DE M 50 H F 50 P01
DE Electrical or Electronic differential indicator Configuration example 2: DE H 50 F A 70 P01
DL Electrical / Visual differential indicator
Configuration example 3: DL E 70 V A 71 P01
DT Electronic differential indicator
DV Visual differential indicator Configuration example 4: DT A 50 H F 70 P01
Configuration example 5: DV M 95 V P01
Type DE DL DT DV
A Standard type • • • A With automatic reset
M With wired electrical connection • M With manual reset
E For high power supply •
H Hazardous area •
Pressure setting DEA DEH DEM DLA DLE DT DV
12 1.2 bar • • • • • •
20 2.0 bar • • • • • •
50 5.0 bar • • • • • • •
70 7.0 bar • • • • • • •
95 9.5 bar • • • • • •

Seals DEA DEH DEM DLA DLE DT DV


F MFQ •
H HNBR • • • • • •
V FPM • • • • • • •
Thermostat DEA DEH DEM DLA DLE DT DV
A Without • • • • •
F With thermostat • • •
Electrical connections DEA DEH DEM DLA DLE DT DV
10 Connection AMP Superseal series 1.5 •
20 Connection AMP Timer Junior •
30 Connection Deutsch DT-04-2-P •
35 Connection Deutsch DT-04-3-P •
48 Connection M20 •
49 Connection 1/2” NPT •
50 Connection EN 175301-803 • •
51 Connection EN 175301-803, transparent base with lamps 24 Vdc •
52 Connection EN 175301-803, transparent base with lamps 110 Vdc • Option
70 Connection IEC 61076-2-101 D (M12) • • P01 MP Filtri standard
71 Connection IEC 61076-2-101 D (M12), black base with lamps 24 Vdc • Pxx Customized

DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATOR PLUG


Series Configuration example T2 H
T2 Indicator plug
Seals
H HNBR
V FPM

13 Clogging Indicators
STAINLESS STEEL DIFFERENTIAL INDICATORS
Dimensions

DEH*48 Connection diagram Materials


Hazardous Area - Body: AISI 316 Stainless steel
Electronic Differential Indicator - Contacts: Rhodium (tungsten optional)
Settings Ordering code Red Black - Seal: MFQ - FPM
5.0 bar ±10% DE H 50 x A 48 P01
White Protection class EX ia IIC T4/T6: Intrinsically safe
7.0 bar ±10% DE H 70 x A 48 P01
28 Temperature class T4 (135 °C) and T6 (85 °C)
M20 x 1.5
Technical data
- Max working pressure: 420 bar
- Working temperature: From -60 °C to +125 °C
- Connection type: M20 x 1.5 - 3 core polyrad cable supplied with 5 meters
A/F 25 mm - Contact type: SPCO/SPDT (Hermetically sealed - volt free contacts)
Max tightening - Compatibility with fluids: Mineral oils, Synthetic fluids
87.5

torque: 50 N∙m HFA, HFB, HFC according to ISO 2943


114

- Degree of protection: IP 66/67/68 according to EN 60529

Electrical data
- Certification / Approvals: - Current Ratings 24v DC 830mA - 110v AC 180mA
ATEX, IECEx, TRCU, INMETRO - Electrical Ratings Ui 30V - Li 250mA - Pi 1.3W
- Certification included
as standard

DEH*49 Connection diagram Materials


Hazardous Area - Body: AISI 316 Stainless steel
Electronic Differential Indicator - Contacts: Rhodium (tungsten optional)
Red Black - Seal: MFQ - FPM
Settings Ordering code
5.0 bar ±10% DE H 50 x A 49 P01 White Protection class Ex d IIC T4/T6: Flameproof
7.0 bar ±10% DE H 70 x A 49 P01
28 Temperature class T4 (135 °C) and T6 (85 °C)
Green
1/2” NPT Technical data
- Max working pressure: 420 bar
- Working temperature: From -60 °C to +120 °C : ATEX, IECEx, TRCU, INMETRO
From -60 °C to +105 °C : UL/CSA
- Connection type: 1/2” NPT - 3 core polyrad cable supplied with 5 meters
A/F 25 mm - Contact type: SPCO/SPDT (Hermetically sealed - volt free contacts)
Max tightening - Compatibility with fluids: Mineral oils, Synthetic fluids
87.5

torque: 50 N∙m HFA, HFB, HFC according to ISO 2943


- Certification / Approvals: - Degree of protection: IP 66/67/68 according to EN 60529
114

ATEX, IECEx, TRCU, INMETRO,


UL/CSA Class I Division 1 Electrical data
Groups A-D, - Current Ratings 24v DC 830mA - 110v AC 180mA
UL/CSA Class II Division 1 - Electrical Ratings Supply Voltage 24 VDC 110 VAC
Groups E-G Max switching current 830mA 180mA
- Certification included Max voltage 150 V AC/DC
as standard Power watts 20 W VA

DEH*70 Connection diagram Materials


Hazardous Area - Body: AISI 316 Stainless steel housing with internal
Electronic Differential Indicator Brown engineered resin switch
Settings Ordering code
1
Blue - Contacts: Rhodium
4 2
5.0 bar ±10% DE H 50 x A 70 P01 3 Black - Seal: MFQ - FPM
7.0 bar ±10% DE H 70 x A 70 P01
Protection class EX ia IIC T6: Intrinsically safe

Temperature class T6 (85 °C)


M12
Technical data
28 mm O.D. - Max working pressure: 420 bar
- Working temperature: From -20 °C to +80 °C
- Connection type: 4 pole male M12 connector - plastic
- Contact type: SPCO/SPDT (Hermetically sealed - volt free contacts)
42.5
90

A/F 25 mm - Compatibility with fluids: Mineral oils, Synthetic fluids


Max tightening HFA, HFB, HFC according to ISO 2943
torque: 50 N∙m - Degree of protection: IP 66/67 according to EN 60529
26.5

- Certification / Approvals: Electrical data


ATEX, IECEx, TRCU, INMETRO - Current Ratings 24v DC 830mA - 110v AC 180mA
- Certification included - Electrical Ratings Ui 30V - Li 250mA - Pi 1.3W
as standard

Clogging Indicators 14
STAINLESS STEEL DIFFERENTIAL INDICATORS
Dimensions

DEX*50 Hydraulic symbol Materials


Electrical Differential Indicator - Body: AISI 316L
- Base: Black Nylon
2
Settings Ordering code - Contacts: Silver
1 1 2
5.0 bar ±10% DE X 50 x A 50 P01 3
- Seal: HNBR - MFQ
7.0 bar ±10% DE X 70 x A 50 P01
9.5 bar ±10% DE X 95 x A 50 P01 Technical data
- Max working pressure: 420 bar
- Proof pressure: 630 bar 4
- Burst pressure: 1260 bar
Electrical symbol
- Working temperature: From -25 °C to +110 °C
3
2
- Compatibility with fluids: Mineral oils,
3 Synthetic fluids

1 1 HFA, HFB,1 HFC according to ISO 2943


- Degree protection: IP66 according to EN 60529
53

53

50
3
2 2
IP69K according to ISO 20653
53

53

50
Electrical data
A/F 30 - Electrical connection: EN 175301-803
Max tightening - Resistive load: 0.2 A / 115 Vdc
torque: 65 N∙m
2
1 1 2
3
2
1
1
3 2

DLX*51 - DLX*52 Hydraulic symbol Materials 4


3

Electrical/Visual Differential Indicator - Body: 5 AISI 316L


- Base: Transparent Nylon
Settings Ordering code 2 - Contacts: Silver
5.0 bar ±10% DL X 50 x A x x P01 1 - Seal: HNBR - MFQ
7.0 bar ±10% DL X 70 x A x x P01 3
4 4
9.5 bar ±10% DL X 95 x A x x P01 Technical data
Electrical symbol - Max working pressure: 420 bar
4
- Proof pressure: 4
630 bar
3 3 3
- Burst pressure: 1260 bar
1
GREEN
LAMP
RED
LAMP
1 - Working temperature: From -25 °C1 to +110 °C
2 2 - Compatibility with fluids: Mineral oils,2Synthetic fluids
3 3 3HFA, HFB, HFC according to ISO 2943
5
53

50

1 1
2
- Degree protection: 1IP66 according to EN 60529

2 2 1
1 2
IP69K according to ISO 20653
3 2
Electrical data 3 5
A/F 30
Max tightening - Electrical connection:
4 EN 175301-803
torque: 65 N∙m - Type 5 51 52
- Lamps 24 Vdc 110 Vdc
- Resistive load: 1 A / 24 Vdc 1 A / 110 Vdc

DVX Hydraulic symbol Materials


Visual Differential Indicator - Body: AISI 316L
- Internal parts: AISI 316L - Nylon
Settings Ordering code - Contacts: Silver
5.0 bar ±10% DV X 50 x P01 - Seal: HNBR - MFQ
7.0 bar4 ±10% DV X 70 x P01 4

9.5 bar ±10% DV X 95 x P01 Technical data


- Reset: Automatic reset
3 3 - Max working pressure: 420 bar
1 Green / Red 1 - Proof pressure: 630 bar
2 clogging indicator 2
- Burst pressure: 1260 bar
- Working temperature: From -25 °C to +110 °C
5 2 - Compatibility with fluids: Mineral oils, Synthetic fluids
39

34

1 2
3
1
HFA, HFB, HFC according to ISO 2943
- Degree protection: IP65 according to EN 60529
A/F 28
Max tightening
torque: 65 N∙m

2
1
3

15 Clogging Indicators
STAINLESS STEEL DIFFERENTIAL INDICATORS
Dimensions

DVY Hydraulic symbol Materials


Visual Differential Indicator - Body: AISI 316L
- Internal parts: AISI 316L - Nylon
Settings Ordering code - Contacts: Silver
5.0 bar ±10% DV Y 50 x P01 - Seal: HNBR - MFQ
7.0 bar ±10% DV Y 70 x P01
9.5 bar ±10% DV Y 95 x P01 Technical data
- Reset: Manual reset
- Max working pressure: 420 bar
- Proof pressure: 630 bar
Red - Burst pressure: 1260 bar
clogging indicator - Working temperature: From -25 °C to +110 °C
2 - Compatibility with fluids: Mineral oils, Synthetic fluids
34

1 1 2 HFA, HFB, HFC according to ISO 2943


3
- Degree protection: IP65 according to EN 60529

A/F 30
Max tightening
torque: 65 N∙m
10

2
10

1
3

X2 Materials
A/F30A/F30

Indicator plug - Body: AISI 316L


- Seal: HNBR / MFQ
Seal Ordering code
HNBR X2 H
MFQ X2 F
2
1
1
3 2
3
4
5

A/F 30
Max tightening
torque: 50 N∙m

Clogging Indicators 16
STAINLESS STEEL DIFFERENTIAL INDICATORS
Dimensions

DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATORS


Series Configuration example 1: DE H 50 F A 70 P01
DE Electrical or Electronic differential indicator Configuration example 2: DE X 50 H A 50 P01
DL Electrical / Visual differential indicator
Configuration example 3: DL X 95 V A 71 P01
DV Visual differential indicator
Configuration example 4: DV Y 70 V P01

Type DE DL DV
H Hazardous area •
X Standard type • • •
Y Optional type •

Pressure setting
50 5.0 bar
70 7.0 bar
95 9.5 bar

Seals DEH DEX DLX DV


F MFQ •
H HNBR • • •
V FPM • • • •

Thermostat
A Without

Electrical connections DEH DEX DLX DV


48 Connection M20 •
49 Connection 1/2” NPT •
50 Connection EN 175301-803 •
51 Connection EN 175301-803, transparent base with lamps 24 Vdc • Option
52 Connection EN 175301-803, transparent base with lamps 110 Vdc • P01 MP Filtri standard
70 Connection IEC 61076-2-101 D (M12) • Pxx Customized

DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATOR PLUG


Series Configuration example X2 H
X2 Indicator plug
Seals
H HNBR
F MFQ

17 Clogging Indicators
CLOGGING INDICATORS QUICK REFERENCE GUIDE
Filter Filter Visual Electrical Electrical / Visual Electronic
family series indicator indicator indicator indicator
SUCTION

VLA21AA51P01
FILTERS

SF2 250 - 350 VLA21AA52P01


VVA16P01
SF2 500 - 501 - 503 - 504 - 505 VEA21AA50P01 VLA21AA53P01
VVR16P01
SF2 510 - 535 - 540 VLA21AA71P01
BVA14P01 BLA15HA51P01
MPFX-MPTX-MPF-MPT with bypass 1.75 bar BVR14P01 BEA15HA50P01 BLA15HA52P01
MPH with bypass 1.75 bar BVP20HP01 BEM15HA41P01 BLA15HA53P01
BVQ20HP01 BLA15HA71P01
BVA25P01 BLA20HA51P01
RETURN

MPFX-MPTX-MPF-MPT with bypass 3 bar


FILTERS

BVR25P01 BEA20HA50P01 BLA20HA52P01


MPH with bypass 2.5 bar BLA20HA53P01
BVP20HP01 BEM20HA41P01
FRI 255 BLA20HA71P01
BVQ20HP01
DLA20xA51P01
MPLX DLA20xA52P01
DVA20xP01 DEA20xA50P01 DLA20xA71P01 DTA20xF70P01
FRI 025 - 040 - 100 - 250 - 630 - 850 DVM20xP01 DEM20xAxxP01 DLE20xA50P01
DLE20xF50P01
RETURN / SUCTION

VLB21AA51P01
Suction VVB16P01 VLB21AA52P01
MRSX 116 - 165 - 166 VEB21AA50P01 VLB21AA53P01
line VVS16P01
FILTERS

VLB21AA71P01
BEA25HA50P01 BLA25HA51P01
BVA25P01
BEM25HA41P01 BLA25HA52P01
Return MRSX 116 - 165 - 166 BVR25P01
BET25HF10P01 BLA25HA53P01
line LMP 124 MULTIPORT BVP20HP01
BET25HF30P01 BLA25HA71P01
BVQ20HP01
BET25HF50P01
VLB21AA51P01
Suction MPS 050 - 070 - 100 - 150 VVB16P01 VLB21AA52P01
VEB21AA50P01 VLB21AA53P01
line MPS 200 - 250 - 300 - 350 VVS16P01
VLB21AA71P01
BVA14P01 BLA15HA51P01
SPIN-ON
FILTERS

Return MPS 050 - 070 - 100 - 150 BVR14P01 BEA15HA50P01 BLA15HA52P01


line MPS 200 - 250 - 300 - 350 BVP20HP01 BEM15HA41P01 BLA15HA53P01
BVQ20HP01 BLA15HA71P01
DLA12xA51P01
MPS 051 - 071 - 101 - 151 DLA12xA52P01
DVA12xP01 DEA12xA50P01
In-line MPS 301 - 351 DLA12xA71P01
DVM12xP01 DEM12xAxxP01
MSH 050 - 070 - 100 - 150 DLE12xA50P01
DLE12xF50P01
LMP 110 - 112 - 116 - 118 - 119 MULTIPORT
LMP 120 - 122 - 123 MULTIPORT
LMP 210 - 211 - LDP DLA20xA51P01
With LMP 400 - 401 & 430 - 431 DLA20xA52P01
DVA20xP01 DEA20xA50P01 DTA20xF70P01
bypass LMP 900 - 901 DLA20xA71P01
PRESSURE FILTERS

DVM20xP01 DEM20xAxxP01
valve LMP 902 - 903 DLE20xA50P01
LOW & MEDIUM

LMP 950 - 951 DLE20xF50P01


LMP 952 - 953 - 954
LMD 211 - 400 - 401 - 431 - 951 - LDD
LMP 110 - 112 - 116 - 118 - 119 MULTIPORT
LMP 120 - 122 - 123 MULTIPORT
LMP 210 - 211 - LDP DLA50xA51P01
Without LMP 400 - 401 & 430 - 431 DLA50xA52P01
DVA50xP01 DEA50xA50P01 DTA50xF70P01
bypass LMP 900 - 901 DLA50xA71P01
DVM50xP01 DEM50xAxxP01
valve LMP 902 - 903 DLE50xA50P01
Hazardous
N
LMP 950 - 951 DLE50xF50P01
E

LMP 952 - 953 - 954 area electronic


W

LMD 211 - 400 - 401 - 431 - 951 - LDD indicator


FMP 039 - 065 - 135 - 320
FHP 010 - 011 - 065 - 135 - 350 - 500 DLA50xA51P01 DEH50xA48P01
With FMM 050 - 150 DLA50xA52P01 DEH50xA49P01
bypass DVA50xP01 DEA50xA50P01 DTA50xF70P01
FHA 051 DLA50xA71P01 DEH50xA70P01
valve FHM 006 - 007 - 010 - 050 - 065 - 135 - 320 - 500 DVM50xP01 DEM50xAxxP01 DLE50xA50P01 DEH70xA48P01
HIGH PRESSURE

FHB 050 - 135 - 320 DLE50xF50P01 DEH70xA49P01


FHF 325 DEH70xA70P01
FILTERS

FHD 021 - 051 - 326 - 333


FMP 039 - 065 - 135 - 320
FHP 010 - 011 - 065 - 135 - 350 - 500 DLA70xA51P01 DEH50xA48P01
Without FMM 050 - 150 DLA70xA52P01 DEH50xA49P01
bypass FHA 051 DVA70xP01 DEA70xA50P01 DTA70xF70P01 DEH50xA70P01
DLA70xA71P01
valve FHM 006 - 007 - 010 - 050 - 065 - 135 - 320 - 500 DVM70xP01 DEM70xAxxP01 DEH70xA48P01
DLE70xA50P01
FHB 050 - 135 - 320 DLE70xF50P01 DEH70xA49P01
FHF 325 DEH70xA70P01
FHD 021 - 051 - 326 - 333
FZH 010 - 011 - 039 DEH50xA48P01
STAINLESS STEEL

FZP 039 - 136 DEH50xA49P01


HIGH PRESSURE

With
FZX 011 DVX50xP01 DLX50xA51P01 DEH50xA70P01
bypass DEX50xA50P01
FZB 039 DVY50xP01 DLX50xA52P01 DEH70xA48P01
FILTERS

valve
FZM 039 DEH70xA49P01
FZD 051 DEH70xA70P01
FZH 010 - 011 - 039 DEH50xA48P01
Without FZP 039 - 136 DEH50xA49P01
DVX70xP01 DLX70xA51P01 DEH50xA70P01
bypass FZB 039 DEX70xA50P01
DVY70xP01 DLX70xA52P01 DEH70xA48P01
valve FZM 039
FZD 010 - 021 - 051 DEH70xA49P01
DEH70xA70P01

Clogging Indicators 18
NOTES

19 Clogging Indicators
NOTES

Clogging Indicators 20
All data, details and words contained in this publication are provided for information purposes only.
MP Filtri reserves the right to make modifications to the models and versions of the described products at any time
for both technical and / or commercial reasons.
The colors and the pictures of the products are purely indicative.
Any reproduction, partial or total, of this document is strictly forbidden.
All rights are strictly reserved.
WORLDWIDE NETWORK

HEADQUARTERS
MP Filtri S.p.A.
Pessano con Bornago
Milano - Italy
+39 02 957031
sales@mpfiltri.it

BRANCH OFFICES
ITALFILTRI LLC MP Filtri India Pvt. Ltd.
Moscow - Russia Bangalore - India
+7 (495) 220 94 60 +91 80 4147 7444 / +91 80 4146 1444
mpfiltrirussia@yahoo.com sales@mpfiltri.co.in

MP Filtri Canada Inc. MP Filtri (Shanghai) Co., Ltd.


Concord, Ontario - Canada Shanghai - Minhang District- China
+1 905 303 1369 +86 21 58919916 116
sales@mpfiltricanada.com sales@mpfiltrishanghai.com

MP Filtri France SAS MP Filtri U.K. Ltd.


Villeneuve la Garenne Bourton on the Water
Paris - France Gloucestershire - United Kingdom
+33 (0)1 40 86 47 00 +44 (0) 1451 822 522
sales@mpfiltrifrance.com sales@mpfiltri.co.uk

MP Filtri Germany GmbH MP Filtri U.S.A. Inc.


St. Ingbert - Germany Quakertown, PA - U.S.A.
+49 (0) 6894 95652 2-0 +1 215 529 1300
sales@mpfiltri.de sales@mpfiltriusa.com

PASSION TO PERFORM
EN - Rev. 12-2019

mpfiltri.com

You might also like