Standard Dimensions - Plumbing
Standard Dimensions - Plumbing
0.375 m Min. distance of water closet center to side wall 3/8" Min. NPS of fixture supply pipe for toilet
0.30 m Min. distance of urinal center to side wall 1/2" Min. NPS of fixture supply pipe for kitchen sink
0.60 m Min. distance of urinal center to urinal center 1/2" Min. NPS of fixture supply pipe for bathtub
0.375 m Min. distance of bidet center to side wall 3/8" Min. NPS of fixture supply pipe for bidet
2% Min. slope of shower receptor 3" Min. fixture drain size for a water closet
4% Max. slope of shower receptor 1.5" Min. fixture drain size for a bathtub
559 mm Min. height of threshold for shower wide door 0.05m (2”) Min. depth of water seal for trap
0.60 sq.m. Min. interior area of shower compartment 0.10m (4”) Max. depth of water seal for trap
4.9 m Min. spacing of drains for gang shower 51 mm Min. height of a water seal for each fixture trap.
Mounting height of wall hung lavatory from the Min. water seal depth or outlet diameter of
32" or 0.80 m 51 mm
FFL grease trap
Max. mounting height of toilet grab bars from
36" or 0.90 m 102 mm Max. height of a water seal for each fixture trap.
FFL
Max. mounting height of tissue paper holder
19" 38 mm (1 ½”) Min. trap diameter for a bathtub
from FFL
150 mm Min. extension of the VSTR above the roof Length of horizontal drain which does not
1.5 m (or less) require a clean-out unless such line is serving
Min. vertical extension of VSTR from any roof sinks or urinal
2.10 m
deck where it is protruded
38 mm Size of cleanout for pipe size of 38 mm ∅
Min. extension of VSTR above any other vertical
300 mm
surface.
38 mm Size of cleanout for pipe size of 51 mm ∅
Min. height of a branch vent above the fixture it
150 mm (6")
is venting
64 mm Size of cleanout for pipe size of 64 mm ∅
Min. height of vent above the highest level rim
152 mm of the fixtures served before offsetting
horizontally. 76 mm Size of cleanout for pipe size of 64 mm ∅
Min. distance of the VSTR from any openable
0.30 m
window. 102 mm or larger Size of cleanout for pipe size of 89 mm ∅
Min. front clearance of clean-out 51 mm or
305 mm
less
Max. front clearance of clean-out 51 mm or
450 mm
more
Min. vertical clearance of clean-out in under
450 mm floor piping extended to or above floor finish Fixture Unit FU 7.5 gal. per minute or 1 cubic ft. per minute
or extended outside the building
Min. horizontal clearance of clean-out in under
750 mm floor piping extended to or above floor finish
or extended outside the building SEPTIC TANK
Min. distance of water piping from any
regulating equipment, water heater,
300 mm Min. width of a septic tank.
conditioning tanks, and similar equipment
requiring union fittings.
Min. length of a septic tank.
3 m (10') Max. spacing of pipe supports at intervals.
Min. Gauge of galvanized sheet used for Min. liquid depth for a septic tank.
26 gauge
downspouts.
Max. liquid depth for septic tank.
1/8 Bend A type of pipe fitting for a Yoke Vent.
Length of house sewer from the inner face of
4 – 5 ft the foundation wall of a building to the
45˚ 1/8 bend elbow junction with another sewer.
7.48 gals
1 cubic foot of water contains
7.5 gals 1 cubic foot of water contains
4.34 psi If the water riser is 3.0 meter in height, what
will be the minimum pressure of the water