INSPECTION & TESTING REQUIREMENTS REVISION: 12/01/2016 CODE NUMBER: PAGE:

SAUDI ARAMCO FORM-175 REPLACES: 02/13/2011 IR790700 1 of 1


SCOPE: IMPELLER: Separately Ordered, for API Pumps with rated power equal to or greater than 300 HP per stage.

TEST AND INSPECTION PER: 31-SAMSS-004 & API-610, and Specifications As Noted Below.

(1).VISUAL INSPECTION BY BUYER INSPECTION REPRESENTATIVE


(2) REVIEW AND VERIFICATION OF MATERIAL CERTIFICATES AND INSPECTION RECORDS
(3) SUBMISSION OF MANUFACTURING, INSPECTION AND QUALITY RECORDS
0010
0030
*** R X
Pre-Fabrication/Production Requirements
Material Test Reports
Specification Details / Notes:
Verify compliance to P.O. specifications.

0020
0020
*** R X
In process inspection & test requirement
Nondestructive Testing Requirements: a)Radiographic
Specification Details / Notes:
If the peripheral velocity of the impeller at rated speed is 75 m/s
Examination (250 fps) or higher. After rough machining, see 31 -SAMSS-004
for details.

0030 R X Nondestructive Testing Requirements: b)Liquid Penetrant For impellers, if the peripheral velocity at rated speed is 45 m/s
Examination or Wet Fluorescent Magnetic Particle Inspection. (150 fps) or higher, per ASME Sec. VIII, Div.1 Appx 6 & 8.

0060 R X Post Weld Heat Treatment Mandatory after major weld repairs per applicable
specifications.

0070 R X Hardness Testing For parts exposed to sour service and shall meet ISO 15156.

0030
0010
*** R X
Final inspection & test requirements
Dynamic Balancing
Specification Details / Notes:
Per API 610. Shall be dynamically balanced to grade G.2.5 of
ISO 1940.

0020 R X Dimensions Per P.O. and applicable specifications.

0030 R X Compliance Certificate

0040 R X Product Test Certificate and records

Notes:
(1) Refer detailed instruction sheet SA175 form IR000003 of inspection requirement for ideal use of this form.

End of IR790700