Professional Documents
Culture Documents
Observation Report
Disciplines
Sr No. Discipline Name Group Name
1 Mechanical Buildings Materials
2 Mechanical Soil and Rock
3 Mechanical Mechanical Properties of Metals
Proposed Scope
Details Data Feeded by Lab Observations
Location 1 PLOT-327/2702, OMFED
Location BACK SIDE, C.S PUR, BBSR-751017
KHORDHA
Discipline: Discipline: Mechanical
Group: Buildings Materials
Product/Material of test Bitumen
Specific Test Performed Ductility
Test method IS :1208, 2014
Range of Testing/Limit of detection 5.0 cm to 150 cm
(±)MU @Value 1.96 cm @ 98.6 cm
Test Performed at PermanentFacility
Location 1 PLOT-327/2702, OMFED
Location BACK SIDE, C.S PUR, BBSR-751017
KHORDHA
Discipline: Discipline: Mechanical
Group: Buildings Materials
Product/Material of test Bitumen
Specific Test Performed Gradation & Extraction
Test method IRC-SP-11, 1988
Range of Testing/Limit of detection 1.0 % to 10 %
(±)MU @Value 0.14 % @ 5.0 %
Test Performed at PermanentFacility
Location 1 PLOT-327/2702, OMFED
Location BACK SIDE, C.S PUR, BBSR-751017
KHORDHA
Discipline: Discipline: Mechanical
Group: Buildings Materials
Product/Material of test Bitumen
Specific Test Performed penetration
Test method IS :1203 , 2014
Range of Testing/Limit of detection 5.0 Div to 400 Div.
(±)MU @Value 1.44 Div. @ 55.0 Div.
Test Performed at PermanentFacility
Location 1 PLOT-327/2702, OMFED
Location BACK SIDE, C.S PUR, BBSR-751017
KHORDHA
Discipline: Discipline: Mechanical
Group: Buildings Materials
Product/Material of test Bitumen
Specific Test Performed Softening Point
Test method IS :1205, 2014
Range of Testing/Limit of detection 5.0 Deg C to 70.0 Deg C
(±)MU @Value 3.06 Deg C @ 54.0 Deg C
Test Performed at PermanentFacility
Location 1 PLOT-327/2702, OMFED
Location BACK SIDE, C.S PUR, BBSR-751017
KHORDHA
Discipline: Discipline: Mechanical
Group: Buildings Materials
Product/Material of test Bitumen
Specific Test Performed Specific Gravity
Test method IS :1202, 2014
Range of Testing/Limit of detection 0.8to 1.20
(±)MU @Value 0.10@ 1.00
Test Performed at PermanentFacility
Location 1 PLOT-327/2702, OMFED
Location BACK SIDE, C.S PUR, BBSR-751017
KHORDHA
Discipline: Discipline: Mechanical
Group: Buildings Materials
Product/Material of test Bricks
Specific Test Performed Compressive Strength
Test method IS :3495 (part-I), 2016
Range of Testing/Limit of detection 1.0 N/mm2 to 30.0 N/mm2
(±)MU @Value 1.0 N/mm2 @ 9.99 N/mm2
Organisation Details
Details Data Feeded by Lab Observations
Location: Location 1
Discipline: Mechanical
Group:
Person Responsible for Technical
Employee Type
Operations
Name Mr.-Saroj kumar nayak
Designation Technical assistant
Qualification MA FROM Utkal University-2007
Specialization soil
Experience in Years Related to Present
8
Work
Relevant Technical Training in house
Landline No 0674-2741383
Mobile No 9439767693
Email t.sarojkumar@gmail.com
whether proposed as authorised signatory No
Location: Location 1
Discipline: Mechanical
Group:
Person Responsible for Technical
Employee Type
Operations
Name Mr.-Sanjaya kumar Mohanty
Designation Technical assistant
Qualification Bachlor of Arts in Utkal University
Specialization soil
Experience in Years Related to Present
04
Work
Relevant Technical Training in house
Landline No 0674-2741383
Mobile No 9437233613
Email sanjayamohanty193@gmail.com
whether proposed as authorised signatory No
Location: Location 1
Discipline: Mechanical
Group:
Person Responsible for Technical
Employee Type
Operations
Name Mr.-MithunSahoo
Designation Testing Engineer
Diploma in civil Engineering in BOSE
Qualification
,Cuttack
Specialization Building Materials
Experience in Years Related to Present
03
Work
Relevant Technical Training in house
Landline No 0674-2741383
Mobile No 7735461335
Email mithunsahoo@gmail.com
whether proposed as authorised signatory No
Location: Location 1
Discipline: Mechanical
Group:
Person Responsible for Technical
Employee Type
Operations
Name Mr.-Sunil kumar pradhan
Designation Technical assistant
Qualification 10th pass
Soil,Rock,Building Materials &
Specialization
Reinforcement of Steel
Experience in Years Related to Present
03
Work
Relevant Technical Training in house
Landline No 0674-2741383
Mobile No 8895481156
Email sunilkumarpradhan196@gmail.com
whether proposed as authorised signatory No
Location: Location 1
Discipline: Mechanical
Group:
Person Responsible for Technical
Employee Type
Operations
Name Mr.-Narendra kumar mishra
Designation Technical assistant
Qualification Bsc from KBDAV ,Nirakarpur
Specialization soil & ducomentation
Experience in Years Related to Present
03
Work
Relevant Technical Training in house
Landline No 0674-2741383
Mobile No 7873391872
Email narendrakumishraqc@gmail.com
whether proposed as authorised signatory No
Location: Location 1
Discipline: Mechanical
Group:
Person Responsible for Technical
Employee Type
Operations
Name Mr.-somonath sahoo
Designation Testing Engineer
Bsc from salipur colleage in the year-
Qualification
2007
Soil,Rock,Building Materials &
Specialization
Reinforcement of Steel
Experience in Years Related to Present
10
Work
Relevant Technical Training in house
Landline No 0674-2741383
Mobile No 7978643884
Email somonathsahoo@gmail.com
whether proposed as authorised signatory No
Location: Location 1
Discipline: Mechanical
Buildings Materials,Mechanical Properties
Group:
of Metals,Soil and Rock
Employee Type Quality Manager
Name Mr.-Sushant Kumar Sahu
Designation QualityManager
Diploma in civil Engineering in
Qualification
Bhubaneswar Polytechnic
Observation 1 Remarks: Please upload 4
Soil,Rock,Building Materials & day training certificate.
Specialization
Reinforcement of Steel
Experience in Years Related to Present
07
Work
in house & 4days training programme
Relevant Technical Training
under process
Landline No 0674-2741383
Mobile No 9776918557
Email Susa1985sahu@gmail.com
whether proposed as authorised signatory Yes
Specimen Signature Download
Location: Location 1
Discipline: Mechanical
Group:
Person Responsible for Technical
Employee Type
Operations
Name Mr.-Kalandi Ghadai
Designation Technical assistant
Qualification 10th fail
Specialization soil
Experience in Years Related to Present
04
Work
Relevant Technical Training in house
Landline No 0674-2741383
Mobile No 9776350187
Email kalandighadai@gmail.com
whether proposed as authorised signatory No
Location: Location 1
Discipline: Mechanical
Group: Buildings Materials
Employee Type Chief Executive of the Laboratory
Name Mr.-P.C Subudhi
Designation
B-TECH IN CIVIL JRNRV
Qualification
UNIVERSITY-2010
Specialization Building Materials
Experience in Years Related to Present
18
Work
Relevant Technical Training In House
Landline No 0674-2741383
Mobile No 9437282818
Email pcsubudhi@gmail.com
whether proposed as authorised signatory Yes
Specimen Signature Download
Location: Location 1
Discipline: Mechanical
Group:
Person Responsible for Technical
Employee Type
Operations
Name Mr.-Uttam kumar Dalai
Designation Testing Engineer
Diploma in civil Engineering in BOSE
Qualification
,Cuttack
Specialization Building Materials
Experience in Years Related to Present
05
Work
Relevant Technical Training in house
Landline No 0674-2741383
Mobile No 7437998971
Email uttam123.dalai@gmail.com
whether proposed as authorised signatory No
Location: Location 1
Discipline: Mechanical
Group:
Person Responsible for Technical
Employee Type
Operations
Name Mr.-Bibhuti bhusan Sahoo
Designation Technical assistant
Qualification B-tech in computer science
Specialization Building Materials
Experience in Years Related to Present
01
Work
Relevant Technical Training in house
Landline No 0674-2741383
Mobile No 9658323435
Email b.sahoo.july05@gmail.com
whether proposed as authorised signatory No
Equipment Details
Details Data Feeded by Lab Observations
Location: Location 1
Discipline: Mechanical
Name of Equipment measuring Cylender
UID STEPL/LAB/EQP/MC-38
Model
Serial No
Year Of Make
Range 50-500ml
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Plunger Dial Gauge
UID STEPL/LAB/EQP/PD-6 (b)
Model
Serial No
Year Of Make
Range 0-25mm &0.01mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Bitumen Extractor
UID SA/LAB/EQUIPMENT/BE/48
Model
Serial No
Year Of Make
Range Asper result
Least Count of Equipment
Calibration Date 08-01-2019
Calibration Due on 07-01-2020
CalibratedBy External
External/ laboratory nameExternal/
EIE Instrument Pvt Ltd
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Brass Sieve
UID STEPL/LAB/EQP/B. SIEVE-26 (i)
Model
Serial No
Year Of Make
Range 425 micron
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment CBR Mould
UID STEPL/LAB/EQP/CBRM/10(2)
Model
Serial No
Year Of Make
Range REFER TO RESULT
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. &Calibration Services Pvt
laboratory name Ltd
Location: Location 1
Discipline: Mechanical
Name of Equipment Digital Compression Testing Machine
UID STEPL/LAB/EQP/CTM-02
Model
Serial No H04035
Year Of Make 2011
Range 0.0 KN -3000KN
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ YEA ENGG &CALIBRATION
laboratory name SERVICES PVT LTD
Location: Location 1
Discipline: Mechanical
Name of Equipment Mortar cube mould
UID STEPL/LAB/EQP/MCM/35(h)
Model
Serial No
Year Of Make
Range 70.6 mmX70.6mm X70.6mm
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. &Calibration Services Pvt
laboratory name ltd.
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A.SIEVE-24 (r)
Model
Serial No
Year Of Make
Range 45mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/SIEVE-24(k)
Model
Serial No
Year Of Make
Range 13.2 mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Brass Sieve
UID STEPL/LAB/EQP/B.SIEVE-26 (d)
Model
Serial No
Year Of Make
Range 2.36mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Measuring Cylender
UID STEPL/LAB/EQP/MC-39
Model
Serial No
Year Of Make
Range 20-200ml &2ml
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Plunger Dial Gauge
UID STEPL/LAB/EQP/PD-17
Model
Serial No
Year Of Make
Range 0-25mm &0.01mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Weighing Balance (sp. Gravity M/C)
UID SA/LAB/EQP/DSGM/70
Model
Serial No
Year Of Make
Range 0-5 kg & 0.5 gm
Least Count of Equipment
Calibration Date 28-08-2018
Calibration Due on 27-08-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Water Bath
UID SA/LAB/EQP/WB-55
Model
Serial No
Year Of Make
Range amb. to 110 degree C
Least Count of Equipment
Calibration Date 14-08-2018
Calibration Due on 13-08-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment CBR Mould
UID STEPL/LAB/EQP/CBRM/10(3)
Model
Serial No
Year Of Make
Range Refer to Result
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. &Calibration Services Pvt
laboratory name Ltd
Location: Location 1
Discipline: Mechanical
Name of Equipment Mortar cube Vibrating Machine
UID STEPL/LAB/EQP/MCVM-16
Model
Serial No
Year Of Make
Range
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young engg. &Calibration Services Pvt
laboratory name ltd.
Location: Location 1
Discipline: Mechanical
Name of Equipment mortar cube Mould
UID STEPL/LAB/EQP/MCM/35(i)
Model
Serial No
Year Of Make
Range 70.6mmX 70.6mm X 70.6mm
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. & Calibration Services Pvt
laboratory name Ltd.
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A. SIEVE-25 (c)
Model
Serial No
Year Of Make
Range 40mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/SIEVE-25(i)
Model
Serial No
Year Of Make
Range 12.5mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Brass Sieve
UID STEPL/LAB/EQP/B,SIEVE -26(d.)
Model
Serial No
Year Of Make
Range 2.00mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Measuring Cylender
UID STEPL/LAB/EQP/MC-40
Model
Serial No
Year Of Make
Range 10-100ml &1.0ml
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Plunger Dial gauge
UID STEPL/LAB/EQP/PD-17(a)
Model
Serial No
Year Of Make
Range 0-25mm & 0.01mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Digital Vernier Caliper
UID STEPL/LAB/EQP/DC-45
Model
Serial No
Year Of Make
Range 0-300mm & L.C 0.01mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Integral Proving Ring
UID SA/LAB/EQP/PDG/6B
Model
Serial No pr.2KN.0485
Year Of Make
Range 2 KN
Least Count of Equipment
Calibration Date 29-09-2018
Calibration Due on 28-11-2020
CalibratedBy External
External/ laboratory nameExternal/
DVG LAB & Consultants Pvt ltd
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment CBRMould
UID STEPL/LAB/EQP/CBRM/10(4)
Model
Serial No
Year Of Make
Range Refer to Result
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/
Young Engg. & Calibration Pvt Ltd
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Mortar cube Mould
UID stepl/lab/eqp/mcm/35(a)
Model
Serial No
Year Of Make
Range 70.6mmX70.6mmx70.6mm
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. &Calibration services Pvt
laboratory name Ltd.
Location: Location 1
Discipline: Mechanical
Name of Equipment Mortar cube Mould
UID STEPL/LAB/EQP/MCM/35(j)
Model
Serial No
Year Of Make
Range 70.6mm X70.6mm x70.6mm
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. & Calibration Services Pvt
laboratory name Ltd.
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A.SIEVE-25(d)
Model
Serial No
Year Of Make
Range 26.5mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A.SIEVE-25(j)
Model
Serial No
Year Of Make
Range 10.00mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Brass Sieve
UID STEPL/LAB/EQP/B. SIEVE-26(e)
Model
Serial No
Year Of Make
Range 1.70mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment AIV APPARATUS
UID SA/LAB/EQP/AIV-19
Model
Serial No
Year Of Make
Range Refer to Result
Least Count of Equipment
Calibration Date 21-09-2018
Calibration Due on 20-09-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment DIG. Weighing Balance
UID STEPL/LAB/EQP//DB/29
Model
Serial No
Year Of Make
Range 0.0-15.0 kg& 0.001kg
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Sieve Shaker
UID STEPL/LAB/EQP/SS-08
Model HS-31.15
Serial No 1102226
Year Of Make
Range As per Result
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. & Calbration Services pvt
laboratory name ltd
Location: Location 1
Discipline: Mechanical
Name of Equipment Hot Air Oven
UID STEPL/LAB/EQP/HAO-46
Model
Serial No
Year Of Make
Range 0-200 degree& l.C-1.0 degree
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
NenoTechnical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Proving Ring
UID SA/LAB/EQUIPMENT/PR/7A
Model
Serial No PR.25KN .01435
Year Of Make
Range 25 KN
Least Count of Equipment
Calibration Date 29-09-2018
Calibration Due on 28-11-2020
CalibratedBy External
External/ laboratory nameExternal/
DVG Laboratory &Consultants Pvt .Ltd
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment CBR Mould
UID STEPL/LAB/EQP/CBRM/10(5)
Model
Serial No
Year Of Make
Range Refer to Result
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/
Young Engg. & Calibration Pvt Ltd
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Mortar cube Mould
UID STEPL/LAB/EQP/MCM/35(b)
Model
Serial No
Year Of Make
Range
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. & Calibration services Pvt
laboratory name Ltd.
Location: Location 1
Discipline: Mechanical
Name of Equipment Mortar cube mould
UID STEPL/LAB/EQP/MCM/35 (h)
Model
Serial No
Year Of Make
Range 70.6mm X 70.6mm X70.6mm
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. & Calibration Services Pvt
laboratory name Ltd.
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A. SIEVE-24 (i)
Model
Serial No
Year Of Make
Range 25mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A.SIEVE-25 (k)
Model
Serial No
Year Of Make
Range 9.5 mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Brass Sieve
UID STEPL/LAB/EQP/B. SIEVE-26(f)
Model
Serial No
Year Of Make
Range 1.18 mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Digital Techometer
UID SA/LAB/EQP/TM/105
Model DT 2234B
Serial No 01205581
Year Of Make
Range 2.5 to 99999 rpm & 0.1rpm to 999rpm
Least Count of Equipment
Calibration Date 31-05-2019
Calibration Due on 31-05-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. &Calibration Services Pvt
laboratory name Ltd
Location: Location 1
Discipline: Mechanical
Name of Equipment Measuring Flask
UID STEPL/LAB/EQP/MC-37
Model
Serial No
Year Of Make
Range 1000ml
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Plunger Dial Gauge
UID STEPL/LAB/EQP/PD-7 (b)
Model
Serial No
Year Of Make
Range 0-25mm &0.01mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Softening Point Apparatus
UID SA/LAB/EQUIPMENT/RBA/103
Model
Serial No
Year Of Make
Range As per Result
Least Count of Equipment
Calibration Date 08-01-2019
Calibration Due on 07-01-2020
CalibratedBy External
External/ laboratory nameExternal/
EIE Instrumentspvt ltd
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Brass Sieve
UID STEPL/LAB/EQP/B.SIEVE-26 (d)
Model
Serial No
Year Of Make
Range 2.00 mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment CBR Mould
UID STEPL/LAB/EQP/CBRM/10(1)
Model
Serial No
Year Of Make
Range REFER TO RESULT
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. & Calibrationservices Pvt
laboratory name Ltd.
Location: Location 1
Discipline: Mechanical
Name of Equipment CBR Mould
UID STEPL/LAB/EQP/CBRM/10(9)
Model
Serial No
Year Of Make
Range Refer to result
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg.. & Calibration Services Pvt
laboratory name Ltd
Location: Location 1
Discipline: Mechanical
Name of Equipment VicatNeedle Apparatus
UID SA/LAB/EQP/VA-14
Model
Serial No HC37.10
Year Of Make
Range Refer to Result
Least Count of Equipment
Calibration Date 30-08-2018
Calibration Due on 29-08-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Mortar cube mould
UID STEPL/LAB/EQP/MCM/35 (f)
Model
Serial No
Year Of Make
Range 70.6mmX70.6mm X70.6mm
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. & Calibration Services
laboratory name Pvt.ltd
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Seive
UID STEPL/LAB/EQP/A. SEIVE-25 (b)
Model
Serial No
Year Of Make
Range 53mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/SIEVE 24(j)
Model
Serial No
Year Of Make
Range 16 mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment BrassSieve
UID STEPL/LAB/EQP/B.SIEVE-26 (b)
Model
Serial No
Year Of Make
Range 4.0mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Los Angles Abrasion Tester
UID SA/LAB/EQP/LAA-20
Model
Serial No
Year Of Make
Range As perresult
Least Count of Equipment
Calibration Date 28-08-2018
Calibration Due on 27-08-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment DIG. Weighing Balance
UID STEPL/EQP/LAB/DWB/32
Model
Serial No
Year Of Make
Range 0-10kg&0.5gm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Laboratory Weights
UID SA/LAB/EQP/WB-78
Model
Serial No
Year Of Make
Range 1mg to 100gm
Least Count of Equipment
Calibration Date 13-08-2018
Calibration Due on 12-08-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Measuring Cylender
UID STEPL/LAB/EQP/MC-41
Model
Serial No
Year Of Make
Range 5 to 25 ml & L.c 0.5ml
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Proctor Mould With Rammer
UID SA/LAB/EQP/PMR -09B
Model
Serial No
Year Of Make
Range Refer to result
Least Count of Equipment
Calibration Date 30-08-2018
Calibration Due on 29-08-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment CBR Mould
UID STEPL/LAB/EQP/CBRM/10(6)
Model
Serial No
Year Of Make
Range Refer to Result
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/
Young Engg. & Calibration Pvt Ltd
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment 90 micron Brass Sieve
UID STEPL/LAB/EQP/B.SIEVE-26(l)
Model standard test sieve
Serial No
Year Of Make
Range 90 micron
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
NENO TECHNICAL SERVICES
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Mortar cube mould
UID STEPL/LAB/EQP/MCM/35(c)
Model
Serial No
Year Of Make
Range 70.6mm X 70.6mm X 70.6mm
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. &Calibration Services Pvt
laboratory name ltd.
Location: Location 1
Discipline: Mechanical
Name of Equipment Humidity Chamber
UID STEPL/LAB/EQP/HC-57
Model
Serial No
Year Of Make 2017
Range 0.0 to 70.0 c & 10.00 TO 99.0% RH
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A. SIEVE-24(j)
Model
Serial No
Year Of Make
Range 22.4mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A.SIEVE-25(l)
Model
Serial No
Year Of Make
Range 6.3 mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Brass Sieve
UID STEPL/LAB/EQP/B.SIEVE-26(h)
Model
Serial No
Year Of Make
Range 600 mic
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Digital Compression Testing Machine
UID SA/LAB/EQP/CTM-02 (A)
Model HLA592101
Serial No
Year Of Make
Range 0.0-500 KN
Least Count of Equipment
Calibration Date 26-07-2017
Calibration Due on 26-09-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment DIG. Weighing Balance
UID STEPL/LAB/EQP/DB/30
Model
Serial No
Year Of Make
Range 0-100 KG & 0.01 KG
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Standard Penetrometer
UID SA/LAB/EQUIPMENT/BPM/53
Model
Serial No Yuri/.../070276
Year Of Make
Range 0.5 to 100mm
Least Count of Equipment
Calibration Date 08-01-2019
Calibration Due on 07-01-2020
CalibratedBy External
External/ laboratory nameExternal/
EIE Instruments Pvt Ltd
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Measuring Cylender
UID STEPL/LAB/EQP/MC-42
Model
Serial No
Year Of Make
Range 1 to 10ml &L.c-0.2ml
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Proctor Mould with Rammer
UID SA/LAB/EQP/PMR-09 A
Model
Serial No
Year Of Make
Range refer to result
Least Count of Equipment
Calibration Date 29-08-2018
Calibration Due on 29-08-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment CBR Mould
UID STEPL/LAB/EQP/CBRM/10(7)
Model
Serial No
Year Of Make
Range Refer to result
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. & Calibrationservices Pvt
laboratory name Ltd
Location: Location 1
Discipline: Mechanical
Name of Equipment Dig. Weighing Balance
UID SA/LAB/EQP/DB-27
Model
Serial No
Year Of Make
Range 0-600gm
Least Count of Equipment
Calibration Date 29-09-2018
Calibration Due on 28-09-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Digital Weighing BaLANCE
UID SA/LAB/EQP/DB-28
Model DE-620AS(GREEN LED)
Serial No
Year Of Make
Range 0-620gm
Least Count of Equipment
Calibration Date 29-09-2018
Calibration Due on 28-09-2019
CalibratedBy External
External/ laboratory nameExternal/
NENO TECHNICAL SERVICES
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Mortar cube Mould
UID STEPL/LAB/EQP/MCM/35 (d)
Model
Serial No
Year Of Make
Range 706 mm X 70.6mmx70.6mm
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg.& Calibration Services Pvt
laboratory name Ltd.
Location: Location 1
Discipline: Mechanical
Name of Equipment Analog Stop Watch
UID STEPL/LAB/EQP/SW-63
Model
Serial No
Year Of Make
Range 0.0-15 min , & 0.1 sec
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A. SIEVE-25(e)
Model
Serial No
Year Of Make
Range 20.00mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A.SIEVE-25(m)
Model
Serial No
Year Of Make
Range 4.75mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Brass Sieve
UID STEPL/LAB/EQP/B.SIEVE-26(j)
Model
Serial No
Year Of Make
Range 300 mic
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Flexure Beam Testing Apparatus
UID STEPL/LAB/EQP/FTM/03
Model
Serial No H-33851
Year Of Make
Range 0-200 KN
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Steel Tape
UID SA/LAB/EQP/ST-36
Model
Serial No
Year Of Make
Range 0.0-3000mm
Least Count of Equipment
Calibration Date 21-09-2018
Calibration Due on 20-09-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment DIG.Weighing Balance
UID STEPL/LAB/EQP/DB/31
Model
Serial No
Year Of Make
Range 0-30. KG &0.005 kg
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Specific Gravity Bottle
UID SA/LAB/EQP/BSPG/104
Model
Serial No
Year Of Make
Range 50ml
Least Count of Equipment
Calibration Date 08-01-2019
Calibration Due on 07-01-2020
CalibratedBy External
External/ laboratory nameExternal/
EIE Instruments Pvt Ltd
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Universal Testing Machine (Digital)
UID STEPL/LAB/EQP/UTM-01
Model HL-590.05
Serial No H-04203
Year Of Make
Range 0 - 1000 KN
Least Count of Equipment
Calibration Date 27-07-2019
Calibration Due on 26-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment liquid limitApparatus
UID SA/LAB/EQP/CA-12
Model
Serial No
Year Of Make
Range Refer to result
Least Count of Equipment
Calibration Date 21-09-2018
Calibration Due on 20-09-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment CBR Mould
UID STEPL/LAB/EQP/CBRM/10(8)
Model
Serial No
Year Of Make
Range Refer to Result
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. & Calibration Services Pvt
laboratory name Ltd
Location: Location 1
Discipline: Mechanical
Name of Equipment Le- Chartlier Apparatus
UID SA/LAB/EQP/LCA-15
Model
Serial No HC38.05
Year Of Make
Range Refer to result
Least Count of Equipment
Calibration Date 30-08-2018
Calibration Due on 29-08-2019
CalibratedBy External
External/ laboratory nameExternal/
Neno technical services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Mortar Cube Mould
UID STEPL/LAB/EQP/MCM/35 (e)
Model
Serial No
Year Of Make
Range 70.6mmX 70.6mm X70.6mm
Least Count of Equipment
Calibration Date 05-06-2019
Calibration Due on 05-06-2020
CalibratedBy External
External/ laboratory nameExternal/ Young Engg. & Calibration Services Pvt
laboratory name .Ltd
Location: Location 1
Discipline: Mechanical
Name of Equipment DG. Thermo Hygrometer
UID STEPL/LAB/EQP/DTH-33
Model
Serial No
Year Of Make
-50.00 to 70.0C ,0.1C & 10.0 to 99.0
Range
%RH, 1%
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Techniacal Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment G.I Test Sieve
UID STEPL/LAB/EQP/A. SIEVE-24(l)
Model
Serial No
Year Of Make
Range 19mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Brass Sieve
UID STEPL/LAB/EQP/B.SIEVE-26 (a)
Model
Serial No
Year Of Make
Range 4.75mm
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name
Location: Location 1
Discipline: Mechanical
Name of Equipment Brass Sieve
UID STEPL/LAB/EQP/B.SIEVE-26 (k)
Model
Serial No
Year Of Make
Range 150 mic
Least Count of Equipment
Calibration Date 15-07-2019
Calibration Due on 14-07-2020
CalibratedBy External
External/ laboratory nameExternal/
Neno Technical Services
laboratory name