Configuration and Commissioning


NEC iPasolink.
TP Vega Project

Commissioning Print Screen


Internal Only▲

LOGIN TO iPasolink Equipment.

User Name: Admin


Password: 12345678
Internal Only▲

Main Window
Internal Only▲

Equipment Configuration

Click on “Setup”
to start
configuration.
Internal Only▲

NE Name

Type NE name here and use same format.


Don’t write link ID .Only mention station ID
e.g: site_id-iPaso (200/400/1000)-1 (1
represent the sequence number of IDU on
same station. If there are two IDU write “1” on
upper IDU and write “2” on second IDU and so
on.)
Internal Only▲

Pluggable Module Detection

If new modem card or any other card used,


click on “Auto Detect” or select manually
from the drop down list. Otherwise you
cannot use new cards.
Internal Only▲

Link Configuration

Select link configuration from the drop down


list.
Note: For 1+1 link configuration make sure
the license is available otherwise you cannot
select 1+1 configuration.
Internal Only▲

Click “OK” button after finish.


Internal Only▲

Radio Configuration:

In Radio configuration
Menu, Click on “Setup”
Internal Only▲

ODU Information:

Make sure that ODU information is not “invalid” here. If it is “invalid” check ODU
power, IF cable, IF Connectors etc.

Set Channel spacing as per link budget.


Internal Only▲

Modulation Scheme:

Select Modulation as per link budget.


Internal Only▲

Radio Mode:

Select Radio Mode:


Internal Only▲

Frequency:

Set frequency as per link budget:


Internal Only▲

Press “OK” button after finish:


Internal Only▲

Modem Port Setting

Click on Provisioning->Modem Function Setting->Modem


Port Setting.
Internal Only▲

Link Name/ID:

Click on MODEM Slots and type LINK ID as per actual


scenario. We can identify the links with the this setting. So
this is mandatory.
Internal Only▲

Transmit Power Setting:

Click on “Tx Power Setting” to set the radio transmit power.


Internal Only▲

Tx Power Setting:

Click on desired link MODEM slot and set the power as per link
budget..
Internal Only▲

Metering:

Click on Metering->
Current Metering
Click on MODEM to
check the RSL change
during Alignment.
Internal Only▲

Comments:
 After aforementioned steps we can start the alignment.
 Keep watching RSL at Metering and lock the antennas at more than 3db of
required RSL given in link budget.
Internal Only▲

NMS Configuration for Root NE:

Click on Network Management Configuration and


then click on General Setting.
Click on setup to set the IP.
Internal Only▲

General Setting.

Set IP, Subnet Mask and GW as per given DCN plan and check
“connect NMS port to NMS” to yes for root NE which is
connected with NEC server through router.
Internal Only▲

General Setting (Detailed)

Click on Setup to start


configuration.
Internal Only▲

Inband Management & Ethernet Port Setting

Set Inband
Management to
“not used”

Set NMS port


“Used”
Internal Only▲

NE Branch Setting

Set branch
number to “2
branches”
Default Gateway
is same as the
GW given in
General Setting.
Therefore no
need to change.
Internal Only▲

NMS Branch IP Setting.

Click on “1” to set


branch 1 IP.
Branch 1 is NMS
and the IP given
in General Setting
will appear
automatically
there so no need
to change.
Internal Only▲

NE Branch Setting:

Click on “2” and


set NE branch IP
and subnet mask
as per given DCN
plan.
Note: All MODEM
with this IDU will
automatically get
Branch 2 IP.

Check “yes “ for


Connect to NMS
port and check
“any” for Protect
LCT connection.
Internal Only▲

Routing Setting.

No need to change Routing Setting. Gateway will


automatically appear here when General Setting is
finished.
Internal Only▲

NMS Setting Service Setting

Click on User
Account/ Security
Setting->Security
Management-
>Service Status
Setting.

Service Status
Summary. Should
be same as here.
Internal Only▲

SNMP Setting.

Click on “SNMP”
and enable SNMP
V1, SNMP V3.
Set UDP port to
161.
Internal Only▲

SNMP Community

Click on “SNMP
Community” and set:
Community Name:
public
Access Level: Admin.
Access Control: Enable
Service IP Address:
0.0.0.0
Subnet Mask:
255.255.255.255
Internal Only▲

SNMP Trap Entry and NTP

SNMP Trap Entry


: No change.
NTP Should be in
Running Status
and parameters
should be same
as given here.
Internal Only▲

NTP Server Address and FTP

SNMP Service
Address : No
change.
FTP Should be in
Running Status
and parameters
should be same
as given here.
Internal Only▲

SFTP, HTTP and HTTPS

SFTP : Stopped
HTTP: Running
and TCP port is
80.
HTTPS: Stopped
Internal Only▲

Normal NE NMS Configuration:

For Normal NE we use


the same steps in
General Setting but set
“Connect NMS port to
NMS” to NO.
Internal Only▲

General Setting (Detailed)

Set Inband
Management to
“not used”

Set NMS port


“Used”;;
Internal Only▲

NE Branch Setting:

Set Branch number to


‘1’
Default GW and
branch “1” IP’s will be
same as in general
Setting. No need to
change here.

Set NMS port to “NO”


and Restrict LCT
connection to “Any”
Internal Only▲

Equipment Cascade setting

If there are two IDU’s in station then for DCN we need to


cascade setting for the two IDU’s. Click on Equipment
Cascade Setting and then click on Setup.
Internal Only▲

Equipment Cascade Setting:

Select Number
of NE’s in
station: 2 for
two IDU’s
Own Cascade
ID: 1 is for the
same IDU
connected with
your laptop. 2
is for other IDU
on the same
station.
Set the IP of
other IDU and
click OK.
Internal Only▲

Comments
 Service Status setting in Normal NE is same as root NE. So do the same steps for normal NE.
 In a hub if there are two IDU’s use LAN cable between NMS port to NMS port.
 If in any case NMS port is used we can configure first Eth Port as NE management.
Internal Only▲

Ethernet Function Setting:

Click on Bridge
Setting and then
click on Modify .
Internal Only▲

Bridge Setting:

Set Aging “On”


FDB Aging
Time:300s
GbE Max Frame
Size: 2000 bytes
FE Max Fame
Size:1522bytes
Vlan Mode:802.1Q
(Mandatory)
Default VLAN ID1
Default VLAN TPID:
8100
Internal Only▲

Ethernet Ports Enable/Disable

Ethernet port can be enable or disable from Eth Port


Setting. Click on desired port to enable or disable.
Internal Only▲

Ethernet Port Speed:

If Ethernet port
enabled its speed
should be set
“auto”.
Internal Only▲

VLAN Creation: Example: Site MMN012-MMN008-MMN751_BSC

We want to create
VLAN for ZTE
SDR. First we
enable eth port-1
for SDR. Set the
station ID in port
name.
Internal Only▲

VLAN Setting: Example site:MMN012

Click on VLAN Setting and then click on VLAN List.


Internal Only▲

VLAN List

Click on “Add VLAN. Type VLAN id and VLAN


Service Name. Type site id in VLAN service Name.
Internal Only▲

VLAN Assignment to Eth Port:

Click on Main Board Port01 to assign a VLAN


from VLAN list:
Internal Only▲

VLAN Assignment:

Set port mode “trunk” and check the planned


VLAN ID from list.
Internal Only▲

VLAN assignment to MODEM (radio link) Port:

Click on Main Board Port01 to assign a VLAN


from VLAN list:
Internal Only▲

VLAN Assignment:

Set port mode “trunk” and check the planned


VLAN ID from list.
Internal Only▲

VLAN Main Page after Creation:

After VLAN creation the VLAN ID’s will appear


against each port like here:
Internal Only▲

Far End MMN008 VLAN Creation:

First of all VLAN id of Site MMN012 should be


added in VLAN list of MMN008.:
Internal Only▲

VLAN Assignment of Modem (Radio Link) Port

Assign the VLAN of Site MMN012 to the link MMN012-


MMN008 Modem. Use the same procedure as described in
previous slides:
Internal Only▲

VLAN Assignment to other port facing MMN751-BSC

As there are two IDU on MMN008 station and our example link is in
second IDU but the link with BSC is in first IDU. Therefore we use
Ethernet Ports and a physical LAN cable between two IDU’s. So we
assign VLAN to eth port02 which is connected with first IDU.
Internal Only▲

MMN008 facing MMN751 IDU.

Assignment of
VLAN of
MMN012
coming from
other IDU via
eth port.

Assignment of
VLAN of
MMN012 to
the link facing
BSC_MMN75
1.
Internal Only▲

BSC Site MMN751

At MMN751 VLAN for


MMN012 should be added in
VLAN list.
Internal Only▲

VLAN assignment to Link facing MMN008

Assign the
VLAN of
MMN012 to
Modem Port
MMN008--
MMN751.
Internal Only▲

VLAN Assignment to LAG Ethernet Group:

At BSC site VLANs of all


cluster Sites are assigned to
two GbE Optical Ports.
Normally 3rd &4th port is used
in iPaso. We set LAG function
over these ports. These ports
are physically connected with
PTN via fiber cables and then
PTN is connected with BSC. So
we assign VLAN of our example
site MMN012.
Internal Only▲

Tips for VLAN Configuration:


 VLAN is used for ZTE SDR in Telenor Vega Project.
 We assign VLAN to ZTE SDR and same VLAN is assigned to NEC iPasolink’s ethernet and modem
ports from terminal site to up till BSC site.
 In a hub site we simply assign the VLAN to MODEM facing terminal site and to MODEM facing BSC
site. Same rule of thumb is used for all the hub in the path.
 If there are two IDU’s in a hub we use physical LAN cable between two IDU and assign all the VLAN
coming from sites to both end IDU’s eth ports.
 VLAN mode is always “trunk”
Internal Only▲

Equipment Clock Setting:

Use this setting for Root NE. Root NE is always master and
all other NE’s are salve in iPaso Network.
Internal Only▲

Equipment Clock Setting: Slave

For normal NE use this Clock Setting. Normal NE is always


Slave.
Note: In a hub if there are two IDU’s then the first IDU will be
slave and second IDU will be master. All other IDU connected
with second IDU will be slave.
Internal Only▲

Ethernet QoS Setting:

Click on QoS/
Classification
Setting.
Click on
classification
mode.
Internal Only▲

Equipment Based QoS Mode:

Set Equipment
Based QoS
mode.
Internal Only▲

Select Profile No.

Click on
“Select Profile
No”.
Internal Only▲

Profile 0.

Select the
profile no “0”
to set planned
QoS
parameters.
Internal Only▲

Profile “0” configuration:

Select the
profile no “0”
to set planned
QoS
parameters.

Click on entry
“1” to set the
Priority.

Note: By default
required setting
for Profile “0” is
available in
iPasolink. No
need to change
profile “0”
setting.
Internal Only▲

Profile 1 Configuration.

Select the
profile no “1”
to set planned
QoS
parameters.

Click on entry
“1” to set the
Priority.
Internal Only▲

Profile 1 Setting:

Set the classify


field, classify
Priority and
Classify internal
Priority as per
given Plan.

Click on entry
no one by one
as per
required
entries and set
classify
priorities.
Internal Only▲

Ingress Setting:

No need to set Ingress


Setting.
Internal Only▲

Port Setting:

No need to change Port


Setting.
Internal Only▲

Link Aggregation.

Click on Eth Port and Enable Port


3 and port 4 optical ports. Set the
name of ports as the given ports
in PTN.
Internal Only▲

Link Aggregation

Click Link aggregation


Setting and click on
“Add Lag”
Internal Only▲

LAG configuration.

Select ETH GRP1, Set


the Name, Set LAG on Port
Mode: Static 3 and Port 4 as
Interval: Short given here.
Distribution Rule: L2
Internal Only▲

Link Aggregation Status:

After LAG creation if the fiber cables connected with PTN


then the status should be up. Example is here.
Internal Only▲

VLAN assignment to LAG

Assign All VLAN


from VLAN list to
LAG .
Example is given
here.
Internal Only▲

VLAN assignment to LAG.


Internal Only▲

Thank you.