IPaso Link Configuration and Commissioning
IPaso Link Configuration and Commissioning
Main Window
Internal Only▲
Equipment Configuration
Click on “Setup”
to start
configuration.
Internal Only▲
NE Name
Link Configuration
Radio Configuration:
In Radio configuration
Menu, Click on “Setup”
Internal Only▲
ODU Information:
Make sure that ODU information is not “invalid” here. If it is “invalid” check ODU
power, IF cable, IF Connectors etc.
Modulation Scheme:
Radio Mode:
Frequency:
Link Name/ID:
Tx Power Setting:
Click on desired link MODEM slot and set the power as per link
budget..
Internal Only▲
Metering:
Click on Metering->
Current Metering
Click on MODEM to
check the RSL change
during Alignment.
Internal Only▲
Comments:
After aforementioned steps we can start the alignment.
Keep watching RSL at Metering and lock the antennas at more than 3db of
required RSL given in link budget.
Internal Only▲
General Setting.
Set IP, Subnet Mask and GW as per given DCN plan and check
“connect NMS port to NMS” to yes for root NE which is
connected with NEC server through router.
Internal Only▲
Set Inband
Management to
“not used”
NE Branch Setting
Set branch
number to “2
branches”
Default Gateway
is same as the
GW given in
General Setting.
Therefore no
need to change.
Internal Only▲
NE Branch Setting:
Routing Setting.
Click on User
Account/ Security
Setting->Security
Management-
>Service Status
Setting.
Service Status
Summary. Should
be same as here.
Internal Only▲
SNMP Setting.
Click on “SNMP”
and enable SNMP
V1, SNMP V3.
Set UDP port to
161.
Internal Only▲
SNMP Community
Click on “SNMP
Community” and set:
Community Name:
public
Access Level: Admin.
Access Control: Enable
Service IP Address:
0.0.0.0
Subnet Mask:
255.255.255.255
Internal Only▲
SNMP Service
Address : No
change.
FTP Should be in
Running Status
and parameters
should be same
as given here.
Internal Only▲
SFTP : Stopped
HTTP: Running
and TCP port is
80.
HTTPS: Stopped
Internal Only▲
Set Inband
Management to
“not used”
NE Branch Setting:
Select Number
of NE’s in
station: 2 for
two IDU’s
Own Cascade
ID: 1 is for the
same IDU
connected with
your laptop. 2
is for other IDU
on the same
station.
Set the IP of
other IDU and
click OK.
Internal Only▲
Comments
Service Status setting in Normal NE is same as root NE. So do the same steps for normal NE.
In a hub if there are two IDU’s use LAN cable between NMS port to NMS port.
If in any case NMS port is used we can configure first Eth Port as NE management.
Internal Only▲
Click on Bridge
Setting and then
click on Modify .
Internal Only▲
Bridge Setting:
If Ethernet port
enabled its speed
should be set
“auto”.
Internal Only▲
We want to create
VLAN for ZTE
SDR. First we
enable eth port-1
for SDR. Set the
station ID in port
name.
Internal Only▲
VLAN List
VLAN Assignment:
VLAN Assignment:
As there are two IDU on MMN008 station and our example link is in
second IDU but the link with BSC is in first IDU. Therefore we use
Ethernet Ports and a physical LAN cable between two IDU’s. So we
assign VLAN to eth port02 which is connected with first IDU.
Internal Only▲
Assignment of
VLAN of
MMN012
coming from
other IDU via
eth port.
Assignment of
VLAN of
MMN012 to
the link facing
BSC_MMN75
1.
Internal Only▲
Assign the
VLAN of
MMN012 to
Modem Port
MMN008--
MMN751.
Internal Only▲
Use this setting for Root NE. Root NE is always master and
all other NE’s are salve in iPaso Network.
Internal Only▲
Click on QoS/
Classification
Setting.
Click on
classification
mode.
Internal Only▲
Set Equipment
Based QoS
mode.
Internal Only▲
Click on
“Select Profile
No”.
Internal Only▲
Profile 0.
Select the
profile no “0”
to set planned
QoS
parameters.
Internal Only▲
Select the
profile no “0”
to set planned
QoS
parameters.
Click on entry
“1” to set the
Priority.
Note: By default
required setting
for Profile “0” is
available in
iPasolink. No
need to change
profile “0”
setting.
Internal Only▲
Profile 1 Configuration.
Select the
profile no “1”
to set planned
QoS
parameters.
Click on entry
“1” to set the
Priority.
Internal Only▲
Profile 1 Setting:
Click on entry
no one by one
as per
required
entries and set
classify
priorities.
Internal Only▲
Ingress Setting:
Port Setting:
Link Aggregation.
Link Aggregation
LAG configuration.
Thank you.
Yasir Masood
Microwave Expert
ZTE (Pvt) Ltd Pakistan