You are on page 1of 9

Totem Tech www.totemtek.

com

Installation Manual for AT05 Ver 1.04

1/9
Copyright Totem Technology Co., Ltd – 2016
Totem Tech www.totemtek.com

IO Port specification .................................................................................................................................................... 4

Power connection ....................................................................................................................................................... 5

Ignition detection ......................................................................................................................................................... 5

Digital Input (DI4 (+), DI2 (-)) ....................................................................................................................................... 6

Relay connection ........................................................................................................................................................ 7

Digital output (DO1, DO2, DO3).................................................................................................................................. 7

Analog input (ANI1)..................................................................................................................................................... 8

RS232, 1-Wire ............................................................................................................................................................ 8

2/9
Copyright Totem Technology Co., Ltd – 2016
Totem Tech www.totemtek.com

Document History
Date Version Change item
2016-12-22 Ver 1.04 Update mistake on DO connection
2016-12-21 Ver. 1.03 Update 1 wire connection
2016-10-27 Ver. 1.02 Installation manual

3/9
Copyright Totem Technology Co., Ltd – 2016
Totem Tech www.totemtek.com

IO Port specification

ACC(+) DI2(-) SOS DI4(-) ANI1 DO B(-) 5V GND TX RX

VCC+ VCC GND GND DI3(-) DO VCC DO A(-) Microphone 1-wire 1-wire

Label Color
Section Inactive active Max description
indicator

ACC + >3V 50v Connect with ignition


3 secs de-bounce time.
DI2 ( + ) > 3V 50v
Triggered by positive
Open drain or <
SOS GND SOS button
3V
3 secs de-bounce
Open drain or
DI4 ( - ) GND time. Triggered by
<3V
negative
Analog input to collect
ANI 1 / / 50V
voltage
45V/500m Digital output to control
DO B ( - ) Open drain GND
A A relay
Connect with vehicle
VCC < 9V 9-50v 50v battery
positive
Connect with vehicle
VCC GND GND
battery GND
GND GND SOS GND
Open drain or 3 secs de-bounce time.
DI3 ( - )
<3V Triggered by negative
DO VCC VCC Out 12V 12V VCC out for relay
Digital output to control
DO A ( - ) Open drain >3V 50V
relay or other purpose
5V

GND

TX

RX
B Microphone

Microphone
1-Wire

1-Wire

4/9
Copyright Totem Technology Co., Ltd – 2016
Totem Tech www.totemtek.com

IO port connection

Power connection

INWARD POWER RANGE: 9 – 50V

Ignition detection
Note: GPRS message time interval may different after you connect with ignition (can set in Configuration Manager.)

5/9
Copyright Totem Technology Co., Ltd – 2016
Totem Tech www.totemtek.com

Digital Input (DI3 (-), DI4 (-), DI2 (+))

Positive trigger use to detect windows, door which trigger by positive circuit. Please be noticed that some of
windows/door are built with negative trigger, in this case, we need to use negative trigger digital input (DI2 (-) / Digital
input 2)
In some case, like truck, there is no circuit at back door, so an extra door sensor is required.

Note: Digital input cable connect with any cable from door sensor is fine. No polarity for the door sensor cable.

6/9
Copyright Totem Technology Co., Ltd – 2016
Totem Tech www.totemtek.com

Relay connection

Digital out has 3 control mode:


1. Controls by firmware (in this mode, not able to cut off engine by GPRS/SMS command.)
2. Control by user.
3. Disable.
If want to send command to control output, need to change mode to ‘User defined’. Refer to ‘user manual for
configuration for more detailed information’
Default setting for digital output: controlled by firmware.

85
87a
87 30

86

Digital output (DO2, DO3, DO4)

Other digital output can also connect with a Buzzer or LED lamp to give an alert to driver.

Note: Make sure the buzzer / LED lamp voltage is 12V, or it can NOT be connected with DO VCC. DO VCC voltage
output is 12 V.

7/9
Copyright Totem Technology Co., Ltd – 2016
Totem Tech www.totemtek.com

Analog input (ANI)

Analog use for detecting the voltage for peripheral device.


Typical application is connect with a fuel sensor. Sensor provide by us is a capacitor fuel sensor, length can be cut to
suit different tank size.
After cut, sensor need to calibrate again. For more detailed, please refer to our ‘FL05 fuel sensor manual’

RS232, 1-Wire

Standard firmware come with RFID, OBD feature.


1-wire: standard firmware come with1 i-Button.
All these peripheral with a complete 4PIN connector for connecting with device. No need pay extra for this connector.

Note: External need to supply when Ibutton, Temperature sensor or RS232 device connect with device.

8/9
Copyright Totem Technology Co., Ltd – 2016
Totem Tech www.totemtek.com

------------------------------------------------------------------------------------------END----------------------------------------------------------------------------------------

9/9
Copyright Totem Technology Co., Ltd – 2016