You are on page 1of 6

Client : Date : DEC-05

Project : Calc'd by : MM
Estimate no : Checked by : KP
Contract no :
Sheet no : C05-C2 / 1

CONNECTION NO.C05-C2 ( Splice connection with flange & web plates )

LOADS
Column ( HE 1000M )

Capacity of single Flange Ff := 3201.2 ⋅ kN 50% Capacity of Web Fw := 2681.8 ⋅ kN

HE1000M

A
60

60 120 120 120 120 60


120
120

60
140
120

C/L OF SPLICE
120

140
120

140
120

60
120
60

EXTERNAL COVER PLATE


WEB PLATE 300x40THK (1 NO) (TYP)
600x20THK(2 NOS)

INTERNAL COVER PLATE


100x40THK (2 NOS) (TYP)
180
50

SECTION A-A
NOTES:-

All bolts are M30. Grade 8.8.


All main steel & fittings are S275.

Variation no: Rev date Description


Client : Date : DEC-05
Project : Calc'd by : MM
Estimate no : Checked by : KP
Contract no :
Sheet no : C05-C2 / 2

Material Properties Design Values

N
Design strength of S275 material py275 := 275 ⋅ For S 275 Steel Ke275 := 1.2
Up to & including 16 thk 2
mm

N
Design strength of S275 material py265 := 265 ⋅ For Double line bolts k 2 := 2.5
beyond 16thk and up to & including 2
mm
40mm thk

N
Bearing Strength of S275 Material pbs275 := 460 For Single line bolts k 1 := 0.5
2
mm

Sectional properties Column 1 Column 2


HE1000M HE1000M

Depth Dc1 := 1008mm Dc2 := 1008mm

Width Wc1 := 302mm Wc2 := 302mm

Thickness of flange Tc1 := 40mm Tc2 := 40mm

Thickness of web tc1 := 21mm tc2 := 21mm

Root radius rc1 := 30mm rc2 := 30mm

2 2
Cross sectional area, Ac1 := 44400.mm Ac2 := 44400mm

Bolts Flange Web


Bolt diameter d1 := 30mm d2 := 30mm

Diameter of hole Dh1 := 33mm Dh2 := 33mm

Number of bolt rows nr1 := 4 nr2 := 2

Number of bolt columns nc1 := 2 nc2 := 5

Total number of bolts n1 = 8 n2 = 10

Shear Capacity of bolt Ps1 = 210 kN Ps2 = 210 kN

Variation no: Rev date Description


Client : Date : DEC-05
Project : Calc'd by : MM
Estimate no : Checked by : KP
Contract no :
Sheet no : C05-C2 / 3

Flangeplate(Ext) Flangeplate(Int) Webplate


Length Lf := 960mm Lfi := 960mm Lw := 540mm

Width Wf := 300mm Wfi := 100mm Ww := 600mm

Thickness tfp := 40mm tfpi := 40mm twp := 20mm

Pitch Distance pf := 120mm pfi := 120mm pw := 140mm

Gauge Distance gf1 := 180mm gfw := 120mm

End Distance(top) eft := 60mm efti := 60mm ewt := 60mm

End Distance(bottom) efb := 60mm efbi := 60mm ewb := 60mm

Edge Distance ef := 60mm efi := 50mm ew := 60mm

End Distance column ecf := 60mm ecw := 70mm

Design loads
The force acting / flange Ff := Wc1 ⋅ Tc1 ⋅ py265 Ff = 3201.2 kN

( )
50
The force acting in the web Fw := Ac1 ⋅ py265 − 2Ff ⋅ Fw = 2681.8 kN
100

For flange connection

Check for flange bolt


Bearing capacity in flange Pb := n1 ⋅ d1 ⋅ Tc1 ⋅ pbs275 Pb = 4416 kN
Ff
Shear force per bolt/ shear face Fs := Fs = 200.1 kN
2n1

Ps1 (210.38 kN) > Fs (200.08 kN): Therefore O.K.

Pb (4416 kN) > Ff (3201.2 kN): Therefore O.K.

Block shear in outer column flange plate


Lf
Tensile length Lt := 60mm Shear length Lv := − eft Lv = 420 mm
2

Block shear
⎣ ( )
Pr := 2 ⋅ 0.6 ⋅ Tc1 ⋅ ⎡Lv + Ke275 ⋅ Lt − k 1 ⋅ Dh1 ⎤ ⋅ py265
⎦ Pr = 6006.4 kN

Pr (6006.38 kN) > Ff (3201.2 kN): Therefore O.K.

Variation no: Rev date Description


Client : Date : DEC-05
Project : Calc'd by : MM
Estimate no : Checked by : KP
Contract no :
Sheet no : C05-C2 / 4

Tension on outer flange plate


Axial Tensile / Compressive Fo := 0.5Ff (Assume 50% taken by outer plate) Fo = 1600.6 kN
force in outer flange
2
Gross area of plate Ag := Wf ⋅ tfp Ag = 12000 mm
2
Net area of plate An := Ag − 2 ⋅ Dh1 ⋅ tfp An = 9360 mm
2
Effective net area Ae := Ke275 ⋅ An Ae = 11232 mm

(
Tension capacity of outer flange plate Pt := min Ag , Ae ⋅ py265) Pt = 2976.48 kN

Pt (2976.48 kN) > Fo (1600.6 kN): Therefore O.K.

Compression on outer flange plate(1 No)


Effective Length for Buckling Leff := 2 ⋅ eft Leff = 120 mm
2
tfp
Min radius of gyration ryy := ryy = 11.547 mm
12

1.0 ⋅ Leff
Slenderness ratio λ := λ = 10.39
ryy

N
pc = 265 ( B.S 5950-2000,Cl - 4.7.4 & TABLE 24)
2
mm
Compressive Capacity Pc := Ag ⋅ pc Pc = 3180 kN

Pc (3180 kN) > Fo (1600.6 kN): Therefore O.K.

Tension on inner flange plate


Axial Tensile / Compressive Fi := Ff ⋅ 0.5 (Assume 50% taken by inner plate) Fi = 1600.6 kN
force in inner flange
2
Gross area of plates(2 Nos) Ag := 2 ⋅ Wfi ⋅ tfpi Ag = 8000 mm

2
Net area of plate(2 Nos) An := Ag − 2Dh1 ⋅ tfpi An = 5360 mm

2
Effective net area Ae := Ke275 ⋅ An Ae = 6432 mm

(
Tension capacity of inner flange plate Pt := min Ag , Ae ⋅ py265
(2 No)
) Pt = 1704.5 kN

Pt (1704.48 kN) > Fi (1600.6 kN): Therefore O.K.

Variation no: Rev date Description


Client : Date : DEC-05
Project : Calc'd by : MM
Estimate no : Checked by : KP
Contract no :
Sheet no : C05-C2 / 5

Compression on inner flange plate


Effective Length for Buckling Leff := 2 ⋅ efti Leff = 120 mm
2
tfpi
Min radius of gyration (ryy) ryy := ryy = 11.547 mm
12

1.0 ⋅ Leff
Slenderness ratio ( λ) λ := λ = 10.39
ryy

N
pc = 265 ( B.S 5950-2000,Cl - 4.7.4 & TABLE 24)
2
mm
Compressive Capacity ( Pc) Pc := Ag ⋅ pc Pc = 2120 kN

Pc (2120 kN) > Fi (1600.6 kN): Therefore O.K.

For web connection

Check for web bolt


Bearing capacity Pb := n2 ⋅ d2 ⋅ tc1 ⋅ pbs275 Pb = 2898 kN

Fw
Shear force per bolt/ shear face Fs := Fs = 134.1 kN
2n2

Pb (2898 kN) > Fw (2681.8 kN): Therefore O.K.

Ps2 (210.38 kN) > Fs (134.09 kN): Therefore O.K.

Block shear in column web

Shear length (
Lv := 2 pw + ecw ) Lv = 420 mm k := 4

Tensile length (
Lt := nc2 − 1 gfw ) Lt = 480 mm

Block shear
⎣ (
Pr := 0.6 ⋅ tc1 ⋅ ⎡Lv + Ke275 ⋅ Lt − k ⋅ Dh2 ⎤ ⋅ py265
⎦ ) Pr = 2796.75 kN

Pr (2796.75 kN) > Fw (2681.8 kN): Therefore O.K.

Variation no: Rev date Description


Client : Date : DEC-05
Project : Calc'd by : MM
Estimate no : Checked by : KP
Contract no :
Sheet no : C05-C2 / 6

Tension capacity of web plate


Axial Tensile / Compressive Fw = 2681.8 kN
force in web
2
Gross area of plate Ag := 2Ww ⋅ twp Ag = 24000 mm

2
Net area of plate An := Ag − nc2 ⋅ Dh2 ⋅ twp An = 20700 mm

2
Effective net area Ae := Ke275 ⋅ An Ae = 24840 mm

Tension capacity of web (


Pt := min Ag , Ae ⋅ py265 ) Pt = 6360 kN

Pt (6360 kN) > Fw (2681.8 kN): Therefore O.K.

Compression capacity of web plate

Effective Length for Buckling Leff := 2 ⋅ 70 mm Leff = 140 mm

2
twp
Min radius of gyration (ryy) ryy := ryy = 5.774 mm
12

1.0 ⋅ Leff
Slenderness ratio ( λ) λ := λ = 24.25
ryy

N
pc = 258.4 ( B.S 5950-2000,Cl - 4.7.4 & TABLE 24)
2
mm

Compressive Capacity ( Pc) Pc := Ag ⋅ pc Pc = 6201.1 kN

Pc (6201.07 kN) > Fw (2681.8 kN): Therefore O.K.

Variation no: Rev date Description

You might also like