Table of contents
Project 0
Site 1
Building 1
Storey 1
balcony
Room summary....................................................................................................................................................................................... 3
Luminaire layout plan.............................................................................................................................................................................. 4
Workplane (balcony) / Perpendicular illuminance (adaptive).................................................................................................................. 5
bath
Room summary....................................................................................................................................................................................... 6
Luminaire layout plan.............................................................................................................................................................................. 7
Workplane (bath) / Perpendicular illuminance (adaptive)........................................................................................................................8
bed room
Room summary..................................................................................................................................................................................... 11
Luminaire layout plan............................................................................................................................................................................ 12
Workplane (bed room) / Perpendicular illuminance (adaptive)............................................................................................................. 13
Bed room
Room summary..................................................................................................................................................................................... 17
Luminaire layout plan............................................................................................................................................................................ 18
Workplane (Bed room) / Perpendicular illuminance (adaptive)............................................................................................................. 19
corridor
Room summary..................................................................................................................................................................................... 23
Luminaire layout plan............................................................................................................................................................................ 24
Workplane (corridor) / Perpendicular illuminance (adaptive)................................................................................................................ 25
kitchen
Room summary..................................................................................................................................................................................... 29
Luminaire layout plan............................................................................................................................................................................ 30
Workplane (kitchen) / Perpendicular illuminance (adaptive)................................................................................................................. 31
master bath
Room summary..................................................................................................................................................................................... 35
Workplane (master bath) / Perpendicular illuminance (adaptive)..........................................................................................................36
Master bed room
Room summary..................................................................................................................................................................................... 39
Workplane (Master bed room) / Perpendicular illuminance (adaptive)................................................................................................. 40
salon
Room summary..................................................................................................................................................................................... 44
Workplane (salon) / Perpendicular illuminance (adaptive).................................................................................................................... 45
shower
Room summary..................................................................................................................................................................................... 49
Workplane (shower) / Perpendicular illuminance (adaptive)................................................................................................................. 50
toilet
Room summary..................................................................................................................................................................................... 54
Workplane (toilet) / Perpendicular illuminance (adaptive)..................................................................................................................... 55
Page 2
Project 0 21/10/2019
balcony
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (balcony) Perpendicular illuminance (adaptive) [lx] * 100 (≥ 100) 62.9 122 0.63 0.52
Height: 0.000 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 5.17 W/m² = 5.15 W/m²/100 lx (Floor area of room 7.74 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 3
Project 0 21/10/2019
balcony
Page 4
Project 0 21/10/2019
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Isolines [lx]
Scale: 1 : 50
Scale: 1 : 50
Scale: 1 : 50
Page 5
Project 0 21/10/2019
bath
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (bath) Perpendicular illuminance (adaptive) [lx] * 273 (≥ 300) 222 311 0.81 0.71
Height: 0.000 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 13.72 W/m² = 5.02 W/m²/100 lx (Floor area of room 5.32 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 6
Project 0 21/10/2019
bath
Page 7
Project 0 21/10/2019
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Page 8
Project 0 21/10/2019
Isolines [lx]
Scale: 1 : 25
Scale: 1 : 25
Page 9
Project 0 21/10/2019
Scale: 1 : 25
Page 10
Project 0 21/10/2019
bed room
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (bed room) Perpendicular illuminance (adaptive) [lx] * 184 (≥ 200) 125 221 0.68 0.57
Height: 0.000 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 4.29 W/m² = 2.33 W/m²/100 lx (Floor area of room 18.66 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 11
Project 0 21/10/2019
bed room
Page 12
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / bed room / Workplane (bed room) / Perpendicular illuminance (adaptive)
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Page 13
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / bed room / Workplane (bed room) / Perpendicular illuminance (adaptive)
Isolines [lx]
Scale: 1 : 25
Page 14
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / bed room / Workplane (bed room) / Perpendicular illuminance (adaptive)
Scale: 1 : 25
Page 15
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / bed room / Workplane (bed room) / Perpendicular illuminance (adaptive)
Scale: 1 : 25
Page 16
Project 0 21/10/2019
Bed room
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (Bed room) Perpendicular illuminance (adaptive) [lx] * 264 (≥ 300) 136 461 0.52 0.30
Height: 0.000 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 6.68 W/m² = 2.53 W/m²/100 lx (Floor area of room 16.39 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 17
Project 0 21/10/2019
Bed room
Page 18
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / Bed room / Workplane (Bed room) / Perpendicular illuminance (adaptive)
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Page 19
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / Bed room / Workplane (Bed room) / Perpendicular illuminance (adaptive)
Isolines [lx]
Scale: 1 : 25
Page 20
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / Bed room / Workplane (Bed room) / Perpendicular illuminance (adaptive)
Scale: 1 : 25
Page 21
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / Bed room / Workplane (Bed room) / Perpendicular illuminance (adaptive)
Scale: 1 : 25
Page 22
Project 0 21/10/2019
corridor
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (corridor) Perpendicular illuminance (adaptive) [lx] * 127 (≥ 100) 25.5 187 0.20 0.14
Height: 0.000 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 4.37 W/m² = 3.45 W/m²/100 lx (Floor area of room 18.31 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 23
Project 0 21/10/2019
corridor
Page 24
Project 0 21/10/2019
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Page 25
Project 0 21/10/2019
Isolines [lx]
Scale: 1 : 50
Page 26
Project 0 21/10/2019
Scale: 1 : 50
Page 27
Project 0 21/10/2019
Scale: 1 : 50
Page 28
Project 0 21/10/2019
kitchen
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (kitchen) Perpendicular illuminance (adaptive) [lx] * 501 (≥ 500) 225 982 0.45 0.23
Height: 1.000 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 11.01 W/m² = 2.20 W/m²/100 lx (Floor area of room 9.95 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 29
Project 0 21/10/2019
kitchen
Page 30
Project 0 21/10/2019
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Page 31
Project 0 21/10/2019
Isolines [lx]
Scale: 1 : 25
Page 32
Project 0 21/10/2019
Scale: 1 : 25
Page 33
Project 0 21/10/2019
Scale: 1 : 25
Page 34
Project 0 21/10/2019
master bath
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (master bath) Perpendicular illuminance (adaptive) [lx] * 389 (≥ 300) 197 478 0.51 0.41
Height: 0.000 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 12.04 W/m² = 3.10 W/m²/100 lx (Floor area of room 6.06 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 35
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / master bath / Workplane (master bath) / Perpendicular illuminance (adaptive)
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Page 36
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / master bath / Workplane (master bath) / Perpendicular illuminance (adaptive)
Isolines [lx]
Scale: 1 : 25
Scale: 1 : 25
Page 37
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / master bath / Workplane (master bath) / Perpendicular illuminance (adaptive)
Scale: 1 : 25
Page 38
Project 0 21/10/2019
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (Master bed room) Perpendicular illuminance (adaptive) [lx] * 184 (≥ 200) 98.6 250 0.54 0.39
Height: 0.000 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 3.97 W/m² = 2.16 W/m²/100 lx (Floor area of room 25.19 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 39
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / Master bed room / Workplane (Master bed room) / Perpendicular illuminance (adaptive)
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Page 40
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / Master bed room / Workplane (Master bed room) / Perpendicular illuminance (adaptive)
Isolines [lx]
Scale: 1 : 50
Page 41
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / Master bed room / Workplane (Master bed room) / Perpendicular illuminance (adaptive)
Scale: 1 : 50
Page 42
Project 0 21/10/2019
Site 1 / Building 1 / Storey 1 / Master bed room / Workplane (Master bed room) / Perpendicular illuminance (adaptive)
Scale: 1 : 50
Page 43
Project 0 21/10/2019
salon
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (salon) Perpendicular illuminance (adaptive) [lx] * 207 (≥ 200) 76.5 286 0.37 0.27
Height: 0.800 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 3.27 W/m² = 1.58 W/m²/100 lx (Floor area of room 42.78 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 44
Project 0 21/10/2019
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Page 45
Project 0 21/10/2019
Isolines [lx]
Scale: 1 : 50
Page 46
Project 0 21/10/2019
Scale: 1 : 50
Page 47
Project 0 21/10/2019
Scale: 1 : 50
Page 48
Project 0 21/10/2019
shower
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (shower) Perpendicular illuminance (adaptive) [lx] * 219 (≥ 300) 203 235 0.93 0.86
Height: 0.000 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 20.76 W/m² = 9.48 W/m²/100 lx (Floor area of room 1.93 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 49
Project 0 21/10/2019
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Page 50
Project 0 21/10/2019
Isolines [lx]
Scale: 1 : 10
Page 51
Project 0 21/10/2019
Scale: 1 : 10
Page 52
Project 0 21/10/2019
Scale: 1 : 10
Page 53
Project 0 21/10/2019
toilet
Clearance height: 3.000 m, Reflection factors: Ceiling 70.0%, Walls 50.0%, Floor 20.0%, Maintenance factor: 0.70
Workplane
Surface Result Average (Target) Min Max Min/average Min/max
1 Workplane (toilet) Perpendicular illuminance (adaptive) [lx] * 216 (≥ 300) 149 256 0.69 0.58
Height: 0.000 m, Wall zone: 0.000 m
*This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Lighting power density: 13.54 W/m² = 6.26 W/m²/100 lx (Floor area of room 2.70 m²)
The energy consumption quantities do not take into account light scenes and their dimming levels.
Page 54
Project 0 21/10/2019
This result is no longer current! Possibly an object has been modified or added. The project should be recalculated in its entirety to get current results.
Isolines [lx]
Scale: 1 : 25
Scale: 1 : 25
Page 55
Project 0 21/10/2019
Scale: 1 : 25
Page 56