You are on page 1of 18

Quick Links

Logout

QUESTION 1
1. Select the most appropriate option 
Two alternators A and B are sharing a resistive load (p.f. = 1 ) equally. Now if the
excitation of alternator A is increased
1 alternator A will become lagging and alternator B will
. become leading

2 alternator A will become leading and alternator B will


. become lagging

3 both alternators will continue to operate on unity power


. factor

4 both alternators will operate on lagging power factor


.

5 both alternators will operate on leading power factor.


.

4 points   
QUESTION 2
1. Choose the right option - the question may have more than one correct
answer 
Which among the following types of maintenance management procedures is/are
included in a system of planned maintenance:
1 Corrective Maintenance
.

2 Predictive Maintenance
.

3 Repair Maintenance
.

4 Overall preventive
. maintenance

4 points   
QUESTION 3
1. Choose the right option - the question may have more than one correct
answer 
Which among the following is/are the approache(s) for Residual Life Assessment
of Power Plant components?
1 Assessing the condition and remaining life of power plant
. components

2 Optimize inspection and maintenance schedules, to make Run,


. Repair, Replace decision

3 Data analysis based on operational history


.
4 Periodic examination of critical components
.

4 points   
QUESTION 4
1. Select the most appropriate option 
For a transmission line with negligible losses, the lagging reactive power (VAR)
delivered at Ihe receiving end, for a given receiving end voltage, is directly
proportional to the
1 square of the line
. voltage drop

2 line voltage drop


.

3 line inductive reactance


.

4 line capacitive
. reactance

4 points   
QUESTION 5
1. Choose the right option - the question may have more than one correct
answer 
Which of the following is/are the basic ingredients of a 'budget'?
1 It is prepared in advance and based on future plan of action
.

2 It relates to a future period and based on objectives to be


. attaine

3 It is a statement expressed in monitory terms


.

4 It is prepared for implementation of the policy formulated by


. the management.

4 points   
QUESTION 6
1. Choose the right option - the question may have more than one correct
answer 
What capacities beyond design value is/are required in renovation in order to
maintain the rated capacity of the boiler, provided the furnace size is adequate
to burn increased quantities of the inferior quality of coal?
1 raw coal feeding
. system

2 pulverizers
.

3 primary air fan


. system
4 environmental
. regulations

3 points   
QUESTION 7
1. Select the most appropriate option 
Major overhauls are normally planned to coincide with -
1 statutory inspection periods
.

2 favourable season/weather
.

3 budgetary expenditure
.

4 scheduled implementation of saefty


. standards

3 points   
QUESTION 8
1. Select the most appropriate option 
How are MHD generators different from traditional electric generators?
1 They operate at high temperatures without moving parts
.

2 They are modern and speedy generators


.

3 It relies on moving a conductor through a magnetic field to


. generate electric current

4 It pumps liquid metals


.

3 points   
QUESTION 9
1. Choose the right option - the question may have more than one correct
answer 
How do fuses attain faster current limitation as compared to circuit breakers?
1 Fuses are passive elements and are inherently secure and hence attain
. current limitation faster

2 As the current exceeds the fuse's limits it blows thereby disconnecting the
. load from the source

3 Through automatic synchronization


.

4 By means of arc quenching


.

3 points   
QUESTION 10
1. Select the most appropriate option 
When a synchronous motor is running at synchronous speed, the damper
winding produces -
1 damping torque
.

2 eddy current torque


.

3 torque aiding the


. developing torque

4 no torque
.

1 points   
QUESTION 11
1. Fit the best option 
ELECTRIC
To effectively supply electricity to cities and towns   grids are also
used.
1 points   
QUESTION 12
1. Select the most appropriate option 
Which of the following is an advantage of static capacitor for power factor
improvement?
1 Little
. maintenance cost

2 Ease in
. installation

3 Low losses   
.

4 All of the above


.

1 points   
QUESTION 13
1. Select the most appropriate option 
The _______ system is the subsystem in smart grid that provides advanced
management and control services
1 Communicat
. ion

2 Infrastructur
. e

3 Managemen
. t

4 Protection
.

1 points   
QUESTION 14
1. State whether the given statement is true or false 
An electric utility is neither owned not heavily regulated by government
1 fals
. e

2 tru
. e

1 points   
QUESTION 15
1. State whether the given statement is true or false 
Coal, oil, and even solar and nuclear powers can be used to create the steam
necessary to run a thermal plant.
1 true
.

2 Fals
. e

1 points   
QUESTION 16
1. State whether the given statement is true or false 
In the process of power generation in a thermal power plant,a furnace is used to
heat the fuel and supply the heat produced to the boiler
1 tru
. e

2 fals
. e

1 points   
QUESTION 17
1. Select the most appropriate option 
A synchronous condenser is virtually which of the following ?
1 Induction motor
.

2 Under excited
. synchronous motor

3 Over excited synchronous


. motor

4 D.C. generator
.

5 none of the above


.
1 points   
QUESTION 18
1. State whether the given statement is true or false 
Waste heat from industrial processes is occasionally concentrated in a steam
boiler and turbine.
1 fals
. e

2 tru
. e

1 points   
QUESTION 19
1. Select the most appropriate option 
The efficiency of pumped storage plant is generally about:
1 95perc
. ent

2 85perc
. ent

3 65perc
. ent

4 40perc
. ent

1 points   
QUESTION 20
1. Select the most appropriate option 
_______ are single chip computers that allow the devices into which they are built
to process data, accept commands, and communicate information like a
computer.
1 switch gears
.

2 microprocessor
. s

3 copper
. conductors

4 overhead cable
. trays

1 points   
QUESTION 21
1. Select the most appropriate option 
Solid high-level waste from nuclear power stations is -
1 disposed of deep underground and well away from the biosphere
.
2 placed in underground repositories, not necessarily deep, with
. little delay

3 generally buried more conventionally


.

4 removed from stack gases and buried where seepage and run-off
. can be controlled

1 points   
QUESTION 22
1. Select the most appropriate option 
Static capacitors are rated in terms of -
1 kW
.

2 kWh
.

3 kVAR
.

4 none of the
. above

1 points   
QUESTION 23
1. State whether the given statement is true or false 
Rotor is the rotating part of an electrical machine.
1 tru
. e

2 fals
. e

1 points   
QUESTION 24
1. Select the most appropriate option 
The regulating reservoir storing water temporarily when load on plant is reduced
is:
1 Forebay
.

2 Surge tank
.

3 Reservoir
.

4 None of the
. above

1 points   
QUESTION 25
1. Select the most appropriate option 
Salient poles are generally used on -
1 high speed prime movers
. only

2 medium speed prime movers


. only

3 low speed prime movers only


.

4 low and medium speed prime


. movers

1 points   
QUESTION 26
1. Select the most appropriate option 
As an energy efficient application, slip power recovery system fits well for ____
1 Squirrel cage and slip ring
. motors

2 DC motor
.

3 Slip ring motors only


.

4 None of the above


.

1 points   
QUESTION 27
1. Fit the best option 
GENERATING STATION
The   at an electric power station makes one power plant different
from the other.
1 points   
QUESTION 28
1. State whether the given statement is true or false 
In addition to the effect of ash quantity, the physical properties of ash may have
repercussion on boiler efficiency.
1 tru
. e

2 fals
. e

1 points   
QUESTION 29
1. Select the most appropriate option 
_______ is a schedule, document or booklet which shows, in written forms the
budgeting organization and procedures
1 Code of Conduct
.

2 Memorandum of
. Association

3 Budget Manual
.

4 Minutes of meeting
.

1 points   
QUESTION 30
1. Select the most appropriate option 
The difference in expansion between rotor and cylinder is termed as _______
(expansion)
1 experien
. tial

2 differenti
. al

3 rational
.

4 sunstanti
. al

1 points   
QUESTION 31
1. Select the most appropriate option 
The role of efficiency and performance monitoring lies in maximising _______
from the thermal power plants.
1 efficienc
. y

2 generati
. on

3 producti
. on

4 cost
.

1 points   
QUESTION 32
1. Select the most appropriate option 
Heavy water is:
1 H2
. O
2 HO
. 2

3 D2
. O

4 B2
. O

1 points   
QUESTION 33
1. Select the most appropriate option 
In a power plant, coal is carried from storage place to boilers generally by means
of -
1 bucket
.

2 V-belts
.

3 trolleys
.

4 manua
. lly

1 points   
QUESTION 34
1. Select the most appropriate option 
Which of the following plants is almost inevitably used as base load plant ?
1 Diesel engine
. plant

2 Gas turbine
. plant

3 Nuclear power
. plant

4 Pumped storage
. plant

1 points   
QUESTION 35
1. Select the most appropriate option 
_______ refers to the boiler heat loss to the atmosphere by conduction, radiation,
and convection.
1 Steam flow
.

2 Ash fusion
.
3 Radiation
. loss

4 Cooled
. furnaces

1 points   
QUESTION 36
1. Select the most appropriate option 
Tan Delta and DLA tests of stator winding indicate -
1 the status condition of stator winding
. insulation

2 condition of the rotor winding


.

3 stator winding temperatures


.

4 Both 2 & 3
.

1 points   
QUESTION 37
1. Select the most appropriate option 
Which of the following generating stations has the minimum running cost?
1 hydro-electric
. station

2 nuclear power
. station

3 thermal power
. station

4 diesel power
. plant

1 points   
QUESTION 38
1. Fit the best option 

Hydropower plants, sometimes called   plants, use water to produce


nearly a quarter of the world's total requirement of electricity.
1 points   
QUESTION 39
1. Select the most appropriate option 
Ratio of maximum demand to connected load is termed as:
1 Load factor
.

2 Power
. factor

3 Demand
. factor

4 Form factor
.

1 points   
QUESTION 40
1. Select the most appropriate option 
Maximum demand controller is used to ___________.
1 switch off essential loads in a logical
. sequence

2 exceed the demand of the plant


.

3 switch off non-essential loads in a


. logical sequence

4 controls the power factor of the plant


.

1 points   
QUESTION 41
1. Select the most appropriate option 
Which technology is immune to High Magnetic Field?
1 Fibre-optic accelerometers
.

2 generator stator bars


.

3 the turbine cover


.

4 geometrical centres of rotor


. and stator

1 points   
QUESTION 42
1. Select the most appropriate option 
The traditional electrical grid carries power from _______ generators to a large
number of users or customers
1 hi-tech
.

2 electric
. al

3 central
.
4 distribut
. ed

1 points   
QUESTION 43
1. Select the most appropriate option 
A graphical representation of the discharge and time is known as _______
1 Load-curve
.

2 Load–duration
. curve

3 Monograph
.

4 Hydrograph
.

1 points   
QUESTION 44
1. Fit the best option 
THREE
 phase electrical power is the most common method used in
electrical grids throughout the world.
1 points   
QUESTION 45
1. State whether the given statement is true or false 
Geothermal energy power plants, wind turbines and renewable power plants do
not generate electricity for human consumption.
1 fals
. e

2 tru
. e

1 points   
QUESTION 46
1. Fit the best option 
INSULATION
Radiation loss depends on the effectiveness of the boiler casing 
1 points   
QUESTION 47
1. Select the most appropriate option 
In India, _______ power holds the fourth position among the different resources of
electricity
1 Thermal
.

2 Hydro
.
3 Renewable
. resource

4 Nuclear
.

1 points   
QUESTION 48
1. Select the most appropriate option 
Which of the following is not a Primary Energy Source?
1 Oil
.

2 Natural
. Gas

3 Electricit
. y

4 Wood
.

1 points   
QUESTION 49
1. State whether the given statement is true or false 
The variables of a moving sun do not create problems in building a large
capacity solar thermal power plant.
1 tru
. e

2 fals
. e

1 points   
QUESTION 50
1. Select the most appropriate option 
_______ is the static part of rotary electromagnetic devices such as electric
motors, alternators, and generators.
1 Stator
.

2 Rotor
.

3 Armature
.

4 Field
. winding

2 points   
QUESTION 51
1. Select the most appropriate option 
Thorium Breeder Reactors are most suitable for India because - a) they develop
more power b) its technology is simple c) abundance of thorium deposits are
available in India d) these can be easily designed
1b & c
.

2a & c
.

3a & d
.

4 Only
. c

2 points   
QUESTION 52
1. Choose the right option - the question may have more than one correct
answer 
Possible cause(s) for overcurrent is/are:
1 short circuits, excessive load,
. device failure

2 incorrect design, mismatched


. loads

3 device mismatch, low voltage


.

4 correct design, load factor


.

2 points   
QUESTION 53
1. State whether the given statement is true or false 
During power generation in a thermal power plant, special mountings like an
economizer uses the air sent into the combustion chamber to improve the
efficiency of the combustion process.
1 tru
. e

2 fals
. e

2 points   
QUESTION 54
1. Fit the best option 
COOLING
 towers are heat removal devices used to transfer process waste
heat to the atmosphere.
2 points   
QUESTION 55
1. Select the most appropriate option 
Which of the following devices may be used to provide protection against
lightening over voltages ?
1 Horn gaps
.

2 Rod Gaps
.

3 Surge
. absorbers

4 All of the
. above

2 points   
QUESTION 56
1. Select the most appropriate option 
Provision of _______ on generator, turbine and main transformers could be
considered for installation on all existing power stations.
1 Optimum utilisation of the men &
. material

2 On Line Condition Monitoring System


.

3 Procurement of the equipment spares


.

4 Catchment Area Treatment studies for


. the Stations

2 points   
QUESTION 57
1. Select the most appropriate option 
_______ is defined as the ratio of average load to capacity or the ratio of average
load to peak load in a period of time.
1 Capacity
. factor

2 Load
. management

3 Higher load
. factor

4 High load
. factor

2 points   
QUESTION 58
1. Choose the right option - the question may have more than one correct
answer 
What are the new problems faced by the generation owners in the power
generation industry?
1 Deregulation
.

2 Opening of free
. markets

3 Budgetary Controls
.

4 New Technology
.

2 points   
QUESTION 59
1. Select the most appropriate option 
What is the environmental impact of the power plants using natural bodies of
water for cooling on aquatic organisms?
1 Aquatic organisms which adapt to the warmer discharge water may be
. injured if the plant shuts down in cold weather.

2 It lowers the water level which is harmful for aquatic organisms


.

3 It lowers the oxygen level and leaves hazardour gases in the water bodies
.

4 It disturbs their aquatic life


.

2 points   
QUESTION 60
1. Select the most appropriate option 
What does the Skin effect of a conductor results in ?
1 reduced effective resistance but increased effective internal
. reactance of the conductor

2 increased effective resistance but reduced effective internal


. reactance of. the conductor

3 reduced effective resistance as well as effective internal reactance


.

4 increased effective resistance as well as effective internal reactance.


.

2 points   
QUESTION 61
1. Select the most appropriate option 
On arrival at a substation, the power steps down from a transmission level
voltage to a _______ level voltage
1 Distributi
. on
2 High
.

3 Distant
.

4 Demand
.

2 points   
QUESTION 62
1. State whether the given statement is true or false 
Other generators do not incorporate permanent magnets or field windings that
establish a constant magnetic field.
1 tru
. e

2 fals
. e

2 points   
QUESTION 63
1. Select the most appropriate option 
What is the most important thing in warm/hot start up unit activity?
1 To check leakages in the system and monitor pressure
.

2 To synchronize the unit


.

3 To match the steam temperature with that of H.P. cylinder before steam
. admission to turbine.

4 To stop the machine for few hours


.

2 points   

Click Save and Submit to save and submit. Click Save All Answers to save all answers.

Save and Submit


 

You might also like