You are on page 1of 1

Strength and Moment Along Reinforcement in Z direction

Bar size = 20 mm
Number of Bars = 16
Required Steel Area = 4639.9812sq.mm
Provided Steel Area = 6082.0520sq.mm

Balanced Neutral Axis Depth= = 0.1976m

Actual Neutral Axis Depth (Xb)= = 0.0943m

Strength and Moment from Concrete

Cc = = 572.27 kN

Mc = = 91.52 kNm

Calculate strength and moment from one bar.

Distance between extreme fiber and bar, db= 0.07m

Strain in bar, = = 0.0009

Maximum Strain, = = 0.0021

as

= 179992.76kN/m^2

= 0.0016

as

11.52kN/m^2
=
Tension Resisted by
= 50.94kN
Bars,
Moment Resisted by
6.83kNm
Bars,
Total Bar Capacity, Cs (Bar Stress-Concrete Stress)X Bar Area = -820.59kN
=
Capacity of Column =
Capacity of effective
-248.32kN
concrete+ capacity of
steel = Cc + Cs =
Total Moment (Individual Bar Capacity X Moment Arm) = 97.74kNm
capacity provided by
Bars,Ms =
Total Moment, Moz= Mc + Ms = 189.25kNm

Check for Bi-Axial Bending

0.86

Design Moment Mnx = 153.76kNm


Design Moment Mnz = 48.63kNm
Total Moment Mox = 189.26kNm
Total Moment Moz = 189.26kNm
if Mnx or Mnz = 0, then  = 1.0
otherwise,  = 1.5

Combined Footing 2

Page 18 of 174