Design of Base Plate & Anchor Bolts for Service Water Tank(Narimanam site):

Max. Compression under D.L.+L.L. = 18.13 kN


= 1813 kG
Provide 250 X 300 Base Plate.

Bearing Pressure w = 2.417 kG/cm2

fy = 1890 kG/cm2

62.5 125

250 75

300

Thickness required t = 0.422 cm


= 4.223296 mm

Provide 16 thk. Plate minimum.

Design of anchor bolts under DL+WL+Tank Empty

Max. horizontal shear on each bolt = 4.57 kN


= 457 kG
Max. uplift = 8.12 kN
= 812 kG
Provide 20 Ø bolts 4 Nos.

Shear/Bolt = 114.25 kG
Max. uplift/Bolt = 203 kG

Gross Area of 20 mm dia. Bolt = 3.14 cm2


Net Area of 20mm dia. Bolt = 2.45 cm2

Actual Stress in shear = 36.39 kG/cm2


Allowable Stress in Shear as per IS:800-1984 = 80 Mpa
= 800 kG/cm2

Actual Stress in tension = 82.86 kG/cm2

Allowable Stress in tension for Anchor Bolts(Mild Steel = 1500 kG/cm2 >

Check for Combined Stress


36.39/800 + 82.86/1500 = 0.10 < 1.4

ok
82.86 kG/cm2