SFERE D-series

Electronic DIN rail energy meter

The D-series electronic meters are manufactured using


energy metering microprocessor, utilizing digital sampling
and SMT circuit technology.

It conforms to IEC 62053-22:2003 energy measurement


accuracy. lt is primarily used for low voltage AC network
kWh metering. lt also measures the electrical parameters of .-*{}*
voltage, current, power, energy and power factor. t
{i.*
The DIN rail mount construction allows the meter to be
installed in compact electrical distribution box. '**"*-**"**,
SFEFE { "F
Three Phase
Measurements are displayed with a large LCD display for
ease of reading.

Pulse kWh output are standard feature for remote network


reading. Anti-tampering sealing seal for closing the meter
f L

-.**_*ie.-._--._--,-
against unauthorized access. Modbus-RTU communication
interface and multi tariff are optional feature. Single Phase

Single Phase meter Electric


l\,4odel Voltaq-. Multi Tariff
5(30)A, 10(60)A, Network

Three Phase meter DDS L946 1P2W 23OVAC L-N No

DDSF 1945 1P2W 23OVAC L-N Yes


1.5(64) all type
CT Ratio Selectable DTS 1945 4OOVAC L-L
3P4W No
Class Accuracy CIass 0.5 (also available Class 1) 23OVAC L-N
4OOVAC L-L
501'z/ 60Hz DTSF 1946 3P4W Yes
23OVAC L-N
0.90Un to 1.10Un DSS L946 3P3W 4OOVAC L-L No
DSSF 1945 3P3W 4OOVAC L-L Yes
Burden (CT Circuit)

Storage Temperature -25'C to 70"C


5 to 95%RH non-condensing
IP 54 (panel)

IEC 62053-22: 2OO3


IEC 61000 -4-2,3,4,5,6, B,lI
IEC 61000-2-6

Fig 1. Dimension for 1P2W model


(DDS1946, DDSF1946)
72(W) x 9a.3(H)x 63.5(D) mm

lTtTtl| | - ,,1
tl
single phase direct connection single phase connection via CT

a
o
Fig 2. Dimension for 3P3W & 3P4W model I
SFERE D-series
Electronic DIN rail energy meter

Single Phase Three Phase


DDS 1945 DDSF 1946 DSS 1946 DSSF 1946 DTS 1946 DTSF 1946

Single phase
(1P2w)
a o
Three phase three
Wiring mode o a
wire (3P3W)
Three phase four wire
(3P4W) a a

230V a o

Voltage range 3x23014O0V o O

3x400V a a
5(30)A,
Direct input 10(60)A, 20(100)A
Cu rrent
20(100)A
specification
1.5(6)A
lnput via CT
CT Ratio user selectable 30-5,000A/5A

Voltage & current a o a a o o

Power a a a a 'o a
Real-trme
measu rem ent
Power factor a o O a o a

Freq uency a a a a o a

THD a O o a

Bi-directional energy a a a o o a
Energy
Four-quadrant energy
metering
Multi-rate energy o a o

Demand

Events record

Communication I RS485 o o o o o o
interface I Modbus-RTU
Energy pulse O o o o a a

Display mode LCD LCD LCD LCD LCD LCD

o:Yes
- :No
O :Optional Authorized Distributor

Note:
120A 3P4W & 3P3W Direct connection models are available on request
Other voltages are available on request.

@
o