AC system is used at ship due to various advantages over DC system.
Electrical power of AC system has 2 components: Active Power & Reactive Power
Resistor: It consumes Real power (Active Power) and dissipates in the form of
heat and light energy.
WANT TO JOIN
Active Power
MERCHANT
Assume a circuit with a resistor (R), voltage (V) and current ow (I). Waveforms of
NAVY?
voltage and current are in phase and power waveform (by multiplying voltage and
current) is positive always i.e. (-) V and (-) I gives (+) Power. It means power ow is
Reach to us, for personalized
always (+) positive and power is taken from the supply and converted by the resistor
mentor ship in Merchant Navy
into a power output. This power is nothing but Active Power.
GET STARTED
In DC system, there NOW power, so its unit is Kw or W. Simply, (1 V) . (1 A) = 1
is only active
W.
Active power is the power loss across resistance. More accurately, It is the power loss
across reactance, where Reactance = (Inductance + Resistance). It’s the actual power
which is really transferred to the load.
Reactive Power
It represents that the energy is rst stored and then released in the form of
magnetic eld or electrostatic eld in case of inductor or capacitor.
It’s the power that continuously bounce back and forth between load and source.
Power absorbed and returned in load due to its reactive properties and hence
named as reactive power. It’s also called as useless power or watt-less power. It’s unit
is volt-ampere-reactive (VAR) or simply 1 VAR = (1 V) . (1 A).
WANT TO JOIN
MERCHANT
Electrical Power in Single Phase & Three Phase System
NAVY?
Single Phase Three Phase
Reach to us, for personalized
Active Power (P) = VI Cos φ
mentor ship in Merchant NavyActive Power (P) = √3 VI Cos φ
Reactive Power (Q) = VI Sin φ Reactive Power (Q) = √3 VI Sin φ
GET STARTED NOW
Understanding the relationship of active power, reactive power & apparent power:
Power Triangle
Beer Analogy
Relationship between active power, reactive power and total power can be easily
understood by beer mug analogy. Here if we put beer in a beer mug then actual
quantity of beer is like active power, foam in mug is like reactive power and total
beer in mug I.e. nothing but (actual quantity + foam) is like total power.
WANT TO JOIN
Here only actual quantity will full ll your demand i.e. thirst not foam. In the same
MERCHANT
manner, only active power full ll the requirement not reactive power.
NAVY?
Reach to us, for personalized
mentor ship in Merchant Navy
Same relationship can be understood with chips packet analogy also. Here actual
chips present in the packet is like active power (useful), empty or air in the packet is
like reactive power (useless) and total capacity (full packet) is like total power.
Concept of Power Factor
When these three terms (active power, reactive power & apparent power) comes
into picture then there is introduction of another term called Power Factor. Actually
all loads consume both reactive power as well as active power. But they should
consume active power ideally. So for improving the performance of equipment, we
have to improve power factor.
Power factor signi es the amount of active power (useful power) i.e. power available
out of the total power. For example, if p.f = 0.8 then it means 80% of total power
consumed is active power (real power). It’s a measure of how ef ciently electrical
power is converted into useful work output.
Also, Cosine of angle between current and voltage is called power factor. Ratio
between resistance and impedance is also called power factor. Ratio of active power
and apparent power is called power factor.
Power Factor
0 WANT TO JOIN
It represents that load is Inductive and draws only Reactive
power. Active power = 0
1
MERCHANT
It represents that load is Resistive and draws only Active power.
NAVY?
Active power = Apparent power
Power factor must be closer to 1 i.e. total power must be almost equal to active
power to achieve following:
Higher reactive power means higher electrical utilization or higher ef ciency of
machine.
Low energy consumption so that lower expenses on electricity, reduction in heat
losses in transformers, motors etc. and stabilization of voltage.
Here, we can improve power factor to achieve the above mentioned advantages
with the help of Capacitor, Synchronous Condenser, Phase Advancer etc.
Power factor is inversely proportional to current. So, if power factor increases, current
reduces and vice versa. In case of low power factor, current will be high and due to
high current losses will be high and bigger size of conductor required that will be
costly. Due to lower power factor, voltage regulation is affected i.e. there will be
higher voltage drop.
Any system which has a power factor close to 1 is considered as good or excellent
system.
Power Rating
It indicates the power at which machinery gives best performance without affecting
the machinery. There are various power ratings for appliances like watt or KW,
ampere or amps, volts, KVA. For 100% ef cient machinery KVA and KW is equal but
practically it’s not possible.
WANT TO JOIN
KW Rating: Power consuming appliances are rated in KW rating, because we know
MERCHANT
their power factor. For example Motor, Electric kettle etc. are rated in KW.
NAVY?
KVA Rating: Power supplying devices are rated in KVA rating, because we don’t
know their power factor as power factor is decided by the loads. For example,
Reach to us, for personalized
Transformer, Generator etc. are rated in KVA.
mentor ship in Merchant Navy
GET STARTED NOW
Air Pump Images Picture
90 Degree Actives
Tag: Electrical Power, Marine Engineering
Share:
Marine Engineer, graduated from MERI Mumbai with ying colors, sailing
with reputed company, interested in ocean, writing with tea.
WANT TO JOIN
MERCHANT
YOU MAY ALSO LIKE
NAVY?
Reach to us, for personalized
mentor ship in Merchant Navy
LEAVE A REPLY
Your email address will not be published. Required elds are marked *
Comment *
POST COMMENT
WANT TO JOIN
MERCHANT
SEARCH
NAVY?
Search …
LATEST POSTS
MERCHANT
NAVY? What is VIT, Conventional VIT and Super VIT
14 Oct 2018
Reach to us, for personalized
mentor ship in Merchant Navy
What is Turbocharger Surging at Ship
GET STARTED NOW
13 Nov 2019
What is Tie Rod, Function, Number, Pinching Screw and
Maintenance at Ship
26 Oct 2019
WANT TO JOIN
MERCHANT
NAVY?
FROM BLOG
October 14,
GET2018
STARTED NOW
COMPANY
NEWS
About Us
NAVY?
MARINE ENGINEERING
NAVIGATION
NAVIGATION
SHOP
CONTACT US
Email Us:
info@ankitacademy.com
Call Us:
+91 84529 66641
+91 99698 21121
WANT TO JOIN
MERCHANT
NAVY?
Reach to us, for personalized
mentor ship in Merchant Navy