OBSERVATION & TABULATION:

Brake drum dia D =0.2m Input total head h in m of water = Pressure gauge reading in kg/cm2x10
Rope dia T =0.015m Venturimeter head h in m of water = (P x 10) meter
Effective radius of = (D/2 +T) Discharge Q = k √h (h in m of water)
Brake drum = 0.115m Input powr IP =  QH kW (h in m of water)
Weight of rope & hanger = 1kg Brake drum net load W =(W1 + weight of rope hanger) –W2 kg
Spear Opening = Full Turbine output OP = (2 NW Re x 9.81) / 60000 kW
Gate valve opening = Full Efficiency  = (Output / Input) x 100%
‘K’ Value = 3.183 x 10-3 Pumpset brand & model = CRI; 5H3

Sl Pressure Pressure Gauge Discharge Weight Spring Net Speed Output Input Efficiency
N gauge reading Venturi on balance Load
reading -meter hanger reading
P.S P1 p2 P h Q W1 W2 W N OP IP 
2 2 3
kg/cm kg/cm metres m /sec kg kg kg rpm kW KW %
1. 3.45 3.8 3.0 0.8 8 9.0029x10-3 0 0 1 1432 0.1691 3.047 5.5
2. 3.45 3.8 3.0 0.8 7 8.4214x10-3 2 0.5 2.5 1400 0.4133 2.8502 14.5
3. 3.45 3.8 3.0 0.8 7 8.4214x10-3 4 1.1 3.9 1360 0.6263 2.8502 21.9
4. 3.45 3.8 3.0 0.8 7 8.4214x10-3 6 1.9 5.1 1334 0.8033 2.8502 28.2
5. 3.45 3.8 3.0 0.8 7 8.4214x10-3 8 2.4 5.6 1294 0.8556 2.8502 30.0
6. 3.45 3.8 3.0 0.8 7 8.4214x10-3 10 3.0 8 1262 1.1921 2.8502 41.8