You are on page 1of 1

K3G280-AU06-B2(mID:162089) EC centrifugal fan - RadiPac

backward curved, single inlet


epM centrifugal modul (K-Box)

Nominal data
Air performance measured as per ISO 5801 Installation category A.
Nominal voltage range V 1~ 200 .. 277 For detailed information on the measuring setup, please contact ebm-papst.
Frequency Hz 50/60 Suction-side noise levels: LwA measured as per ISO 13347 / LpA with 1 m
distance to fan axis.
Fan speed n min-1 2800
The values given are valid under the measuring conditions mentioned above and
Input power Ped W 715 may vary according to the actual installation situation.
Current draw I A 3.1 With any deviation from the standard setup, the specific values have to be
checked and reviewed with the unit installed.
Mass kg 11.5
qv = airflow pfs = static pressure
Min. ambient temp. °C -25 pf = total pressure (static + dynamic) n = fan speed
Max. ambient temp. °C 40 Ped = electrical input power SFP = specific fan power
ηed = qv x pf / Ped (overall efficiency) ηes = overall static efficiency
Protection class I = current draw LWA(A,in) = sound power inlet
Approvals CCC LWA(A,out) = sound power outlet
LWA(A,in+out) = sound power inlet+outlet
Number of blades 7 ρcalculated to = air density converted to the application
Mounting position Shaft horizontal or rotor on bottom ρmeasured at = air density measured environment
Ucontrol = control voltage
rotor on top on request

Data in operating point

qv m³/h 1700 qv [cfm]


qv cfm 1001 500 1 000 1 500 2 000
pfs Pa 500 900 3.6
pf Pa 516 850 3.4
n min-1 2314 800 3.2
Ped W 426.3 750 3
SFP kW/(m³/s) 0.903 700 2.8
ηed % 57.2
650 2.6
ηes % 55.4
600 2.4
I A 1.92
550 2.2
LWA(A,in) dB(A) 75.6

pfs_ [in. wg]


500 2
pfs [Pa]

LWA(A,out) dB(A) 81.3


LWA(A,in+out) 450 1.8
dB(A) 82.3
Ucontrol V 6.8 400 1.6

Settings 350 1.4

ρcalculated to kg/m³ 1.2 300 1.2

ρmeasured at kg/m³ 1.14 250 1


200 0.8
150 0.6
100 0.4
50 0.2
0 0
300 800 1 300 1 800 2 300 2 800 3 300 3 800
qv [m³/h]

90 90
81.3
76.8
75.6
Sound power in dB

Sound power in dB

75.3

80 80
73.3

73.2
72.2

70.8
70.3

69.3
68.7

66.5

70 70
64.7
65

62.2
63

60.5
60.1

60 60

50 50

40 40
63 125 250 500 1000 2000 4000 8000 LwA 63 125 250 500 1000 2000 4000 8000 LwA
Octave band center frequency on the suction side in Hz Octave band center frequency on the pressure side in Hz

ebm-papst FanScout v3.0.2.13700 collection: 10304/13.04.2017 printed: 2/13/2018 5:58:47 PM · Page 1 / 1

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

You might also like