You are on page 1of 2

Section : 1S3

Type : Extg. Slab Check


Design Code : BS8110:2000
Prepared By : Date : 7/4/2020
Project : Checked By : MPA Job ID :

One-Way Slab Design (Based on BS8110:2000-Part1)


***********************************
Slab Marking = 1S3 _1st Storey
DESIGN INFORMATION
Material Data
Concrete Strength, fcu = 30 N/mm2
Steel Strength of Bent-up Bars, fyb = 460 N/mm2
Steel Strength of Stirrups, fys = 460 N/mm2
Concrete Desity, = 24 kN/m3
Aggregate Size, hagg = 20 mm One Way Slab Load Distribution
Slab Data
Short Span Length, La = 2.2 m
Long Span Length, Lb = 4.5 m
Span Ratio, Lb/La = 2.05 > 2.0
P
Hence, the Slab is One-Way.
Slab Thickness, h = 120 mm
Top Cover = 20 mm
Bottom Cover = 20 mm
Effective Depth from Bottom, d = 95 mm
L
Effective Depth for Top, d' = 25 mm
Main Span Length, L = 2.2 m
Loading Analysis
Self Weight of Slab = 2.9 kN/m2
Finishing+Ceiling = 2.0 kN/m2
M&E Service Load = 0.0 kN/m2
Brick Wall = 0.0 kN/m2
Column Point Load PDL = 35.8 kN
= 3.6 kN/m2
Total Dead Load, DLT = 8.5 kN/m2 Check Spacing
Imposed Live Load, LL = 5.0 kN/m2 smin = hagg+5 or db
Column Point Load PLL = 0.0 kN = 10 mm
= 0.0 kN/m2 smax = 3d or 750
Total Live Load LLT = 5.0 kN/m2 = 280 mm
Total Factored Load, 1.4 DLT+1.6LLT = 19.9 kN/m2 [OK]
Factored Shear Force, Vu = 21.9 kN
Factored Bending Moment, Mu = 10.7 KNm
Provided Reinforcement Details Provided As
Main Bar: Span 1T - 10 @ 250 mm = 314 mm2/m
Support 1T - 10 @ 250 mm = 314 mm2/m
Distribution Bar: Span 1T - 10 @ 250 mm = 314 mm2/m
Support 1T - 10 @ 250 mm = 314 mm2/m

DESIGN REINFORCEMENT FOR BENDING


2
K=Mu/fcubd = 0.04 < 0.156
Compression Steel is not Required. & Use only As,min for Compression Steel.
Distribution Bar:
As,min = 0.13/100 *b *h = 156 mm2/m (For High Strength Steel)
As,min = 0.24/100 *b *h = 288 mm2/m (For Mild Steel)
For Span & Support, As,prov'd = 314 mm2/m > As,min [OK]
z = d[0.5+√(0.25-K/0.9)] = 91 mm
Section : 1S3
Type : Extg. Slab Check
Design Code : BS8110:2000
Prepared By : Date : 7/4/2020
Project : Checked By : MPA Job ID :
= 0.95 d > 0.95d
Main Bar: As,req'd = Mu/0.87 fy z
= 296 mm2/m
As,prov'd = 314 mm2/m > As,req'd [OK]
CHECK SHEAR
At Support, Shear Stress, v = Vu/bd = 0.23 N/mm2 ≤ 0.8√fcu
Limit Shear stress, 0.8√fcu < 5 N/mm2 = 4.38 N/mm2 [OK]
At Distance "d", Vd = 20.0 KN
vd=Vd / bd = 0.21 N/mm2
100 As / bd = 0.33 %
Concrete Shear Stress, vc = 0.67 N/mm2 > vd [OK]
Shear Reinforcement is not required.
Check vc<vd<vc+0.4 If Shear Reinforcement is required [Skip This Step]
vc + 0.4 = 1.07 N/mm2 > vd
Norminal Shear Reinforcement is required.
Avs,nom/sv = 0.4*b / 0.87 fys = 1.00 mm2/mm
Provide Shear Links at Support 0T - 0 @ 125 mm
Avs,prov'd / s = 0.00 mm2/mm
CHECK DEFLECTION
Basic Span/Depth Ratio = 26 (For Continuous)
Moment Distribution Factor, βb = 1.0
M/bd^2 = 1.19
fs=2/3fy(AsReq'd/As prov'd) + 1/βb = 290.2 N/mm2
2
Modification Factor, M.Ftension = 0.55+(477-fs)/(120(0.9+M/bd ))
= 1.30 < 2.0
100As'prov'd/bd = 0.00
Modification Factor, M.FComp = 1+(100As'prov'd/bd)/(3+100 As'prov'd/bd)
= 1.00 < 1.5
Allowable Span-Effective Depth ratio, L/d = 33.71
Actual L/d = 23.16 < Allowable L/d [OK]
CHECK PUNCHING SHEAR DUE TO POINT LOAD
1st Parameter
Total Fatored Point Load P = 35.8 kN
Column Width, a = 300 mm
Column Breadth, b = 300 mm
a
Effective Depth of Slab, d = 82 mm Load 2nd
b Area Parameter
Shear Links @ 1st Perimeter 0T - 8 mm diameter
Shear Links @ 2nd Perimeter 0T - 8 mm diameter 1.5d

Check Shear Stress at Face of Loaded Area


Perimeter, u = 2*(a+b) 0.75d

= 1200 mm
Shear Stress, v=P/ud = 0.36 N/mm2 < 0.8√fcu [OK]
Check 1st Critcal Shear Perimeter at 1.5d from Load Face
P
Perimeter, u = 2*(a+2*1.5d+b+2*1.5d)
= 2184 mm
Shear Stress, v=P/ud = 0.20 N/mm2
u
100 As / bd = 0.38 %
Concrete Shear Stress, vc = 0.72 N/mm2 > v
Hence, Punching Shear Reinforcement is not required.

You might also like