You are on page 1of 14

Contractor: Engineering: Project: Company:

NAWARA PROJECT
(PIPELINE)

Contract n°: OTP/PP/189 OMV/BIMS EPCC PPL


Contractor doc. n°: Engineering doc. n°: Job n°: P13IT02472 Company: doc. n°:

NAWPPL-BIMS-NPPL-000- Class NAWPPL-BIMS-NPPL-000-


Sheet 1 of 14
QC-PRO-00033 1 QC-PRO-00033

NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING


OD 24” – TH.11,91 MM - V bevel
(TECHNICAL SHEETS)

C01 29.04.2015 Issued for OMV review CBU OFE MCI


A01 28.04.2015 Issued for internal review CBU OFE MCI
Rev. Date REVISION TITLE PREPARED CHECKED APPROVED CLIENT

This document is the property of ETAP & OMV. It shall not be copied, reproduced and circulated without the Authorization of ETAP & OMV
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 2 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 3 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 4 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 5 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 6 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 7 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 8 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 9 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 10 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 11 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 12 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 13 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.
NAWARA PROJECT (PIPELINE)

SPECIFIC PROCEDURE FOR AUTOMATIC ULTRASONIC TESTING 24” – 11,91 mm - V bevel


Contractor doc. n°: Engineering doc. n°: Rev.: A01 C01 Company: doc. n°:
NAWPPL-BIMS-NPPL-000- NAWPPL-BIMS-NPPL-000-
QC-PRO-00033 Sheet 14 of 14 QC-PRO-00033

ATTACHMENT 1 : AUT SPECIFIC PROCEDURE OD 24” – TH.11,91 MM - V bevel

File name: NAWPPL-BIMS-NPPL-000- QC-PRO-00033 C01 Specific Procedure for Automatic Ultrasonic Testing 24” – 11,91 mm - V bevel.