You are on page 1of 16

View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

M/s. Abdul Hakim

Bill of Quantities

Bill of Quantities

Unit Total
Price Unit Price Price Total Price
ItemNo Group ItemCode DescriptionofItem MeasurementUnit Quantity
In In Words In In Words
figures (BDT) Figures (BDT)
(BDT) (BDT)

Brick work of Kiln 1st


class bricks/automatic
machine made first
class bricks in cement
mortar (1:6) in
superstructure with
Portland Composite
cement (CEM II/AM,
42.5N) and best
quality sand (minimum
FM1.2) with uniform
Eleven
width and depth joints, Six Thousand
Thousand
true to vertical and Three
Five Hundred
Building horizontal lines, in/c Hundred and
1 5.04.03.01.2 cum 1.810 6397.001 11578.572 and
Works raking out joints, filling Ninety-Seven
Seventy-Eight
interstices tightly with point Zero
point Five
mortar, cleaning and Zero One
Seven Two
soaking bricks at least
for 24 hours before
use, washing of sand,
necessary scaffolding,
curing for requisite
period, etc. all
complete as per
direction of the E-I-C.
Kiln bricks Add for
each additional floor
up to 5th floor

125mm brick work with


Kiln 1st class
bricks/automatic
machine made first
class bricks in cement
mortar (1:4) with
Portland Composite
cement (CEM II/AM,
42.5N) and best
quality sand (minimum
FM1.2) and making
bond with connected
Seventy-Nine
walls with uniform Nine Hundred
Thousand
width and depth joints, and
Building Nine Hundred
2 5.04.10.01.2 true to vertical and sqm 84.256 949.001 Forty-Nine 79959.028
Works and Fifty-Nine
horizontal lines in/c point Zero
point Zero
necessary scaffolding, Zero One
Two Eight
raking out joints,
cleaning and soaking
the bricks at least for
24 hours before use,
washing of sand,
curing for requisite
period, etc. all
complete as per
direction of the E-I-C.
Kiln bricks Add for
each additional floor
up to 5th floor

RCC:1:2:4, 20MPa, Fifteen Sixty-Four


Building
3 5.05.02.03.2 Stone Chips (SC): cum 4.193 15353.001 Thousand 64375.133 Thousand
Works

1 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

Reinforced cement
concrete works with
minimum cement
content relates to mix
ratio (tentative 1:2:4)
and maximum water
cement ratio 0.40
having minimum
required average
strength, f'cr = 26 Mpa
and satisfying a
specified compressive
strength f'c = 20 Mpa
at 28 days on standard
cylinders as per
standard practice of
Code AASHTO/ ASTM
and Portland
Composite Cement
conforming to BDS EN
197-1 : 2003 CEM-II
42.5N, best quality
sand of minimum FM
2.2, 20mm down well
graded crushed stone
chips (Preferably stone
chips from
Madhyapara, Dinajpur)
(LAA value not
exceeding 35)
conforming to ASTM C
33 or Aggregate
Grading Appendix-3
LGED Schedule of
Rates or any other
International
recognized envelop Three Three
and Water reducing Hundred and Hundred and
chemical admixture of Fifty-Three Seventy-Five
complying type A point Zero point One
under ASTM C 494, Zero One Three Three
in/c cost of breaking
chips, screening
through proper sieves,
cleaning and washing
thoroughly, centering,
shuttering in position,
with plain 16 BWG
steel sheet fitted over
38mm thick wooden
plank panels suitably
braced and Standard
size Bamboo Props
making shuttering fully
leak proof, placing of
reinforcement cage in
position, mixing the
aggregates with
standard mixer
machine with hoper,
fed by standard
measuring boxes,
maintaining allowable
slump of 75mm to
100mm casting in steel
forms, compacting by
Mechanical vibrators
and tapered rods and
curing at least for 28
days, removing
centering-shuttering
after approved
specified time period,
i/c cost of additional
testing charges of
materials and cylinders

2 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

required. Excluding the


cost of reinforcement
and its fabrication,
welding, coupling,
placing, binding etc.
additional quantity of
Plasticizer i.e. Water
reducing chemical
admixture of complying
type A under ASTM C
494 to reduce mixing
water required for
normal workability and
to maintain low water-
cement (W/C) ratio
(Doses of admixture to
be fixed by the mix
design from approved
laboratory instruction
by the Engineer)
Additional quantity of
cement to be added if
required to attain the
strength at the
contractor's own cost
etc. all complete as per
direction and approval
of the Engineer in
charge.Note : Using
Concrete Mixer. In
pedestal, column,
capital lift wall and wall
: Add for each
additional floor up to
5th Floor

RCC:1:2:4, 20MPa,
Stone Chips (SC):
Reinforced cement
concrete works with
minimum cement
content relates to mix
ratio (tentative 1:2:4)
and maximum water
cement ratio 0.40
having minimum
required average
strength, f'cr = 26 Mpa
and satisfying a
specified compressive
strength f'c = 20 Mpa
at 28 days on standard
cylinders as per
standard practice of Twelve One
Code AASHTO/ ASTM Thousand Thousand
and Portland Nine Hundred Four Hundred
Building
4 5.05.02.04.2 Composite Cement cum 0.110 12968.001 and 1426.480 and
Works
conforming to BDS EN Sixty-Eight Twenty-Six
197-1 : 2003 CEM-II point Zero point Four
42.5N, best quality Zero One Eight
sand of minimum FM
2.2, 20mm down well
graded crushed stone
chips (Preferably stone
chips from
Madhyapara, Dinajpur)
(LAA value not
exceeding 35)
conforming to ASTM C
33 or Aggregate
Grading Appendix-3
LGED Schedule of
Rates or any other
International
recognized envelop
and Water reducing

3 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

chemical admixture of
complying type A
under ASTM C 494,
in/c cost of breaking
chips, screening
through proper sieves,
cleaning and washing
thoroughly, centering,
shuttering in position,
with plain 16 BWG
steel sheet fitted over
38mm thick wooden
plank panels suitably
braced and Standard
size Bamboo Props
making shuttering fully
leak proof, placing of
reinforcement cage in
position, mixing the
aggregates with
standard mixer
machine with hoper,
fed by standard
measuring boxes,
maintaining allowable
slump of 75mm to
100mm casting in steel
forms, compacting by
Mechanical vibrators
and tapered rods and
curing at least for 28
days, removing
centering-shuttering
after approved
specified time period,
i/c cost of additional
testing charges of
materials and cylinders
required. Excluding the
cost of reinforcement
and its fabrication,
welding, coupling,
placing, binding etc.
additional quantity of
Plasticizer i.e. Water
reducing chemical
admixture of complying
type A under ASTM C
494 to reduce mixing
water required for
normal workability and
to maintain low water-
cement (W/C) ratio
(Doses of admixture to
be fixed by the mix
design from approved
laboratory instruction
by the Engineer)
Additional quantity of
cement to be added if
required to attain the
strength at the
contractor's own cost
etc. all complete as per
direction and approval
of the Engineer in
charge.Note : Using
Concrete Mixer. In Tie
Beam and Lintel : Add
for each additional
floor up to 5th Floor

RCC:1:2:4, 20MPa, Thirteen Twenty


Building Stone Chips (SC): Thousand Thousand
5 5.05.02.05.2 Reinforced cement cum 1.521 13359.001 Three 20319.041 Three
Works
concrete works with Hundred and Hundred and

4 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

minimum cement
content relates to mix
ratio (tentative 1:2:4)
and maximum water
cement ratio 0.40
having minimum
required average
strength, f'cr = 26 Mpa
and satisfying a
specified compressive
strength f'c = 20 Mpa
at 28 days on standard
cylinders as per
standard practice of
Code AASHTO/ ASTM
and Portland
Composite Cement
conforming to BDS EN
197-1 : 2003 CEM-II
42.5N, best quality
sand of minimum FM
2.2, 20mm down well
graded crushed stone
chips (Preferably stone
chips from
Madhyapara, Dinajpur)
(LAA value not
exceeding 35)
conforming to ASTM C
33 or Aggregate
Grading Appendix-3
LGED Schedule of
Rates or any other
International
recognized envelop
and Water reducing
chemical admixture of
complying type A Fifty-Nine Nineteen
under ASTM C 494, point Zero point Zero
in/c cost of breaking Zero One Four One
chips, screening
through proper sieves,
cleaning and washing
thoroughly, centering,
shuttering in position,
with plain 16 BWG
steel sheet fitted over
38mm thick wooden
plank panels suitably
braced and Standard
size Bamboo Props
making shuttering fully
leak proof, placing of
reinforcement cage in
position, mixing the
aggregates with
standard mixer
machine with hoper,
fed by standard
measuring boxes,
maintaining allowable
slump of 75mm to
100mm casting in steel
forms, compacting by
Mechanical vibrators
and tapered rods and
curing at least for 28
days, removing
centering-shuttering
after approved
specified time period,
i/c cost of additional
testing charges of
materials and cylinders
required. Excluding the
cost of reinforcement

5 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

and its fabrication,


welding, coupling,
placing, binding etc.
additional quantity of
Plasticizer i.e. Water
reducing chemical
admixture of complying
type A under ASTM C
494 to reduce mixing
water required for
normal workability and
to maintain low water-
cement (W/C) ratio
(Doses of admixture to
be fixed by the mix
design from approved
laboratory instruction
by the Engineer)
Additional quantity of
cement to be added if
required to attain the
strength at the
contractor's own cost
etc. all complete as per
direction and approval
of the Engineer in
charge.Note : Using
Concrete Mixer. In Tee
Beam, Ell Beam,
Rectangular Beam etc.
(exposed breadth and
width of ribs to be
measured only). Add
for each additional
floor up to 5th Floor

RCC:1:2:4, 20MPa,
Stone Chips (SC):
Reinforced cement
concrete works with
minimum cement
content relates to mix
ratio (tentative 1:2:4)
and maximum water
cement ratio 0.40
having minimum
required average
strength, f'cr = 26 Mpa
and satisfying a
specified compressive
strength f'c = 20 Mpa
at 28 days on standard
cylinders as per
standard practice of Fifty-Seven
Thirteen
Code AASHTO/ ASTM Thousand
Thousand
and Portland Eight
Building Two Hundred
6 5.05.02.06.2 Composite Cement cum 4.358 13266.001 57813.232 Hundred and
Works and Sixty-Six
conforming to BDS EN Thirteen point
point Zero
197-1 : 2003 CEM-II Two Three
Zero One
42.5N, best quality Two
sand of minimum FM
2.2, 20mm down well
graded crushed stone
chips (Preferably stone
chips from
Madhyapara, Dinajpur)
(LAA value not
exceeding 35)
conforming to ASTM C
33 or Aggregate
Grading Appendix-3
LGED Schedule of
Rates or any other
International
recognized envelop
and Water reducing

6 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

chemical admixture of
complying type A
under ASTM C 494,
in/c cost of breaking
chips, screening
through proper sieves,
cleaning and washing
thoroughly, centering,
shuttering in position,
with plain 16 BWG
steel sheet fitted over
38mm thick wooden
plank panels suitably
braced and Standard
size Bamboo Props
making shuttering fully
leak proof, placing of
reinforcement cage in
position, mixing the
aggregates with
standard mixer
machine with hoper,
fed by standard
measuring boxes,
maintaining allowable
slump of 75mm to
100mm casting in steel
forms, compacting by
Mechanical vibrators
and tapered rods and
curing at least for 28
days, removing
centering-shuttering
after approved
specified time period,
i/c cost of additional
testing charges of
materials and cylinders
required. Excluding the
cost of reinforcement
and its fabrication,
welding, coupling,
placing, binding etc.
additional quantity of
Plasticizer i.e. Water
reducing chemical
admixture of complying
type A under ASTM C
494 to reduce mixing
water required for
normal workability and
to maintain low water-
cement (W/C) ratio
(Doses of admixture to
be fixed by the mix
design from approved
laboratory instruction
by the Engineer)
Additional quantity of
cement to be added if
required to attain the
strength at the
contractor's own cost
etc. all complete as per
direction and approval
of the Engineer in
charge.Note : Using
Concrete Mixer. In roof
slab of all types,
cantilever slab and
drop panels (excluding
floor slab of ground
floor at plinth level).
Add for each additional
floor up to 5th Floor

7 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

RCC:1:2:4, 20MPa,
Stone Chips (SC):
Reinforced cement
concrete works with
minimum cement
content relates to mix
ratio (tentative 1:2:4)
and maximum water
cement ratio 0.40
having minimum
required average
strength, f'cr = 26 Mpa
and satisfying a
specified compressive
strength f'c = 20 Mpa
at 28 days on standard
cylinders as per
standard practice of
Code AASHTO/ ASTM
and Portland
Composite Cement
conforming to BDS EN
197-1 : 2003 CEM-II
42.5N, best quality
sand of minimum FM
2.2, 20mm down well
graded crushed stone
chips (Preferably stone
chips from
Madhyapara, Dinajpur)
(LAA value not
exceeding 35)
conforming to ASTM C
33 or Aggregate
Grading Appendix-3
LGED Schedule of One
Eighteen
Rates or any other Thousand
Thousand
International Five Hundred
Building Two Hundred
7 5.05.02.07.2 recognized envelop cum 0.084 18209.001 1529.556 and
Works and Nine
and Water reducing Twenty-Nine
point Zero
chemical admixture of point Five
Zero One
complying type A Five Six
under ASTM C 494,
in/c cost of breaking
chips, screening
through proper sieves,
cleaning and washing
thoroughly, centering,
shuttering in position,
with plain 16 BWG
steel sheet fitted over
38mm thick wooden
plank panels suitably
braced and Standard
size Bamboo Props
making shuttering fully
leak proof, placing of
reinforcement cage in
position, mixing the
aggregates with
standard mixer
machine with hoper,
fed by standard
measuring boxes,
maintaining allowable
slump of 75mm to
100mm casting in steel
forms, compacting by
Mechanical vibrators
and tapered rods and
curing at least for 28
days, removing
centering-shuttering
after approved
specified time period,
i/c cost of additional

8 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

testing charges of
materials and cylinders
required. Excluding the
cost of reinforcement
and its fabrication,
welding, coupling,
placing, binding etc.
additional quantity of
Plasticizer i.e. Water
reducing chemical
admixture of complying
type A under ASTM C
494 to reduce mixing
water required for
normal workability and
to maintain low water-
cement (W/C) ratio
(Doses of admixture to
be fixed by the mix
design from approved
laboratory instruction
by the Engineer)
Additional quantity of
cement to be added if
required to attain the
strength at the
contractor's own cost
etc. all complete as per
direction and approval
of the Engineer in
charge.Note : Using
Concrete Mixer. In
sunshade, cornice,
railing, drop wall,
louver and fins
(Average 62mm to
87mm thick) Add for
each additional floor
up to 5th Floor

Supplying and
fabrication of Ribbed
or deformed bar
reinforcement for all
types of RCC work
including straightening,
removing ruts,
cleaning, cutting,
hooking, bending,
lapping and/or welding
wherever required as
directed, placing in
position, tieing with 22
BWG black annealed
binding wire (PVC
coated in case of One Lakh
FBEC rebar) double Eighty-One
fold, cost of binding Seventy-Eight Thousand Six
Building
8 5.06.01.02 wire and anchoring to kg 2329.342 78.001 point Zero 181691.005 Hundred and
Works
the adjoining members Zero One Ninety-One
wherever necessary, point Zero
supplying and placing Zero Five
with proper cover
blocks (1:1), supports,
chairs, spacers,
splices or laps etc.
including cost of all
materials, cost of
labour, cost of
equipment &
machinery, loading
and unloading,
transportation, all other
incidental charges and
work at all leads and
lifts etc. to complete

9 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

the work as per


design, drawing,
specifications and
direction of the E-I-C.
Measurement relating
to nominal mass,
dimensions and
tolerances of various
types of steel shall
conform to relevant
BDS/ ASTM codes.
Reinforcement shall be
measured only in
lengths of bar as
actually placed in
position on standard
weight i.e. 7850 kg/m3
(BNBC Table 6.2.1)
basis. No separate
payment shall be
allowed for Chairs of
any shape & profile,
spacer bar of any
shape & profile, lap/
splice unless otherwise
shown in the drawing,
wastages, binding
wire, concrete cover
blocks etc. as the cost
of these is included in
the unit rate. Note:
Tests for reinforcing
bars shall be
conducted at LGED/
BUET/ DUET/ CUET/
KUET/ RUET. Grade
400 (RB 400/ 400W):
Ribbed or Deformed
bar produced and
marked as per BDS
ISO 6935-2:2006 with
minimum yield
strength, fy (ReH) =
400 MPa, but the
tested yield strength
shall not exceed fy by
more than the 125
MPa and the ratio of
tested ultimate
strength, fu (Re) to
tested yield strength
(fy) shall be at least
1.25 and minimum
elongation after
fracture (A5.65) &
minimum total
elongation at
maximum force (Agt) is
14% and 2.5%
respectively.

Minimum 12mm thick


cement plaster (1:4)
with Portland
Composite cement
(CEM II/AM, 42.5N)
and best quality sand Two Hundred
(minimum FM1.2) to Nine Hundred
and
Building dado, plinth wall up to and Four
9 5.12.01 sqm 3.660 247.001 Forty-Seven 904.024
Works 150mm below ground point Zero
point Zero
level, water tank or Two Four
Zero One
any where directed
with neat cement
finishing in/c washing
of sand, racking out
joint and picking up

10 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

cement morter i/c


finishing the edges and
corners and curing for
the requisite period
etc. all complete as per
direction of the E-I-C.

Minimum 12mm thick


cement plaster (1:6)
with Portland
Composite cement
(CEM II/AM, 42.5N)
and best quality sand
(minimum FM1.2) to Thirty-Two
wall both inner and Thousand
Two Hundred
outer surface, finishing Five Hundred
Building and Twenty
10 5.12.02.02 the corner and edges sqm 148.087 220.001 32579.288 and
Works point Zero
in/c washing of sand Seventy-Nine
Zero One
cleaning the surface, point Two
scaffolding and curing Eight Eight
for the requisite period
etc. all complete as
per direction of the
E-I-C. Add for each
additional floor for 5th
floor

Minimum 6mm thick


cement plaster (1:4)
with Portland
Composite cement
(CEM II/AM, 42.5N)
and best quality sand
(minimum FM1.2) to
ceiling RCC columns,
beams, surface of stair Fifteen
case, sunshades, Thousand
Two Hundred
cornices, railings, drop Four Hundred
Building and Six point
11 5.12.03.02 wall, louvers, fins and sqm 74.870 206.001 15423.295 and
Works Zero Zero
finishing the corners Twenty-Three
One
and edges in/c point Two
washing of sand Nine Five
cleaning the surface,
scaffolding and curing
for the requisite period
etc. all complete as
per direction of the
E-I-C. Add for each
additional floor upto
5th floor

Plaster rule pointing


works 250mmx75mm
size as brick shape by
10mmx10mm grove on
outside wall over
minimum 12mm thick
cement plaster (1:6)
with Portland Eighteen
Composite cement Two Hundred Thousand
(CEM II/AM, 42.5N), and Four Hundred
Building
12 5.12.22 best quality sand sqm 69.007 268.001 Sixty-Eight 18493.945 and
Works
(minimum FM1.2), point Zero Ninety-Three
finishing the corners Zero One point Nine
and edges including Four Five
washing of sand,
cleaning the surface,
scaffolding and curing
for requisite period etc.
all complete as per
drawing and direction
of the E-I-C.

Providing drip One Hundred Three


Building course/nosing and Thousand
13 5.12.10 /throating at the edge m 28.560 124.001 Twenty-Four 3541.469 Five Hundred
Works
of sunshade or cornice point Zero and

11 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

with cement mortar


(1:2) with Portland
Composite cement
(CEM II/AM, 42.5N)
and best quality sand Forty-One
(minimum FM1.2) in/c. Zero One point Four Six
scaffolding, curing at Nine
least for 7 days etc. all
complete for all floors
as per direction of the
E-I-C .

25mm thick artificial


patent stone floor
(1:2:4) with Portland
Composite cement
(CEM II/AM, 42.5N),
best quality coarse
sand (minimum
FM1.8) and 10mm
down well graded
Three
picked brick chips Three
Thousand Six
(LAA value not Hundred and
Building Hundred and
14 5.13.01 exceeding 38) in/c sqm 11.459 318.001 Eighteen 3643.973
Works Forty-Three
breaking graded point Zero
point Nine
picked chips, Zero One
Seven Three
screening, mixing,
laying the concrete in
alternate panels,
compacting and
finishing the top with
neat cement, curing,
etc. all complete as
per direction of the
E-I-C.

Painting with plastic


emulsion paint of best
quality and approved
colour in a seal
container from
authorized
manufacturer. Applying
each coat and
successive coat is to
be applied as per
manufacturer special
procedure, to wall and
ceiling in two coats
over a coat of priming
coat of water sealer
and ready mixed putty
of approved brand. It
applied on sand
Twenty
papered and cleaned
Two Hundred Thousand Six
surface and after
Building and Two point Hundred and
15 5.16.05.01 drying applied sealer sqm 102.406 202.001 20686.114
Works Zero Zero Eighty-Six
coat, 2 coats of ready
One point One
mixed wall putty of
One Four
approved brand, each
coat dried and
smoothened by sand
papering. Applying
plastic emulsion paint
one vertical and one
horizontal coat for
each coat and
successive coat is to
be applied after drying
up of previous coat by
brush/roller/spray in/c
cleaning the plinth,
floors, doors, windows,
portions and
ventilators by washing,
rubbing, as necessary

12 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

and sand papering the


surface and necessary
scaffolding, etc. curing
for the requisite period
etc. all complete for all
floors i/c cost of all
materials as per
direction of the E-I-C.

On exterior surface
applying as per
manufacturer
instruction specific
coat of weather coat of
approved quality and
colour delivered from
authorized local agent
of the manufacturer in
a sealed container.
Applying one vertical Forty
and one horizontal Two Hundred Thousand
Building coat for each coat and and Fifteen Seven
16 5.16.09.01 sqm 189.558 215.001 40755.160
Works successive coat is to point Zero Hundred and
be applied after drying Zero One Fifty-Five
up of previous coat by point One Six
brush/roller/spray in/c
cleaning, washing,
rubbing, as necessary
and sand papering the
surface and necessary
scaffolding, etc. all
complete for all floors
i/c cost of all materials
as per direction of the
E-I-C. 3 coat

Supplying, fitting and


fixing steel glazed sky
light frame (Stair Back
fixed Window) at stairs
as per design having
?T' section made with
flat bar 25mmx3mm as
base and 19mmx3mm
flat bar as
perpendicular at mid of
base flat bar welded
200mm c/c grid and
Outer frame having
25mmx25mmx3mm
MS angle in/c all cost
of charges for
fabrication and
manufacture by Two Four
welding, riveting, etc. Thousand Thousand
supplying all essential Four Hundred One Hundred
Building
17 5.08.14.02 fittings like 150mm sqm 1.696 2468.001 and 4185.730 and
Works
long clamps for fitting Sixty-Eight Eighty-Five
frame in/c supplying, point Zero point Seven
fitting, fixing 5mm thick Zero One Three
glass panes at grid
opening by putty and
painting the sky light
with two coats of
synthetic enamel paint
over a coat of
anticorrosive priming,
making necessary
holes in wall and RCC
work as necessary,
filling with CC (1:2:4:)
and mending good the
damages for all floors,
etc. all complete as
per direction of the
E-I-C and as per

13 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

drawing and design.

Supplying, fitting &


fixing of Pad lock &
key heavy duty Steel
sheet body of
approved and
Four Hundred Eight
accepted color, quality
and Hundred and
Building and type made in India
18 5.08.30.01 each 2.000 426.001 Twenty-Six 852.002 Fifty-Two
Works or equivalent best
point Zero point Zero
quality etc. all
Zero One Zero Two
complete as per
direction of the E-I-C.
75mm Pad lock & key
heavy duty Steel sheet
body

Painting to dado,
skirting, out side plinth
wall from 6'' below GL
to plinth level with two
coats of synthetic
enamel paint of prior
approved colour and
brand over a coat of
priming. Applying one
vertical and one
horizontal coat for Six Hundred
One Hundred
each coat and and
Building and Ninety
19 5.16.10.04 successive coat is to sqm 3.660 190.001 695.404 Ninety-Five
Works point Zero
be applied after drying point Four
Zero One
up of previous coat by Zero Four
brush/ roller/ spray in/c
cleaning, washing,
rubbing, as necessary
and sand papering the
surface and necessary
scaffolding, etc. all
complete for all floors
i/c cost of all materials
as per direction of the
E-I-C.

Supplying, fitting and


fixing door frame with
MS angle
(50mmx50mmx6mm),
fixing, 250mm long 6
nos. of iron clamps of
same size (one end
bifurcated) with vertical
members of the frame,
fixing the frame in wall
with cement concrete
(1:2:4) in Portland
Composite cement
CEM II/AM, 42.5N),
Nine
best quality sand
Thousand
(minimum FM1.8) and Nine Hundred
Five Hundred
Building 20mm down well and Fifty-Four
20 5.07.03.1 m 10.060 954.001 9597.250 and
Works graded 1st class brick point Zero
Ninety-Seven
chips, mending good Zero One
point Two
damages, fixing 3 nos.
Five
of 100mm size iron
hinges with the vertical
members of the frame
for single leaf shutter,
painting all iron faces
in 2 coats over a coat
of priming with enamel
paint of approved
colour and quality, in/c
cutting, sizing, welding
for all floors, etc. all
complete as per plan
and direction of the
E-I-C MS angle

14 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

50mmx50mmx6mm
size

Supplying, fitting and


fixing combined steel
window shutter, frames
and grill welded
together as per
drawing & design
having requisite Nos.
of vertical and
horizontal standard
MS
(19mmx19mmx3mm)
?Z' section for shutter
and MS flat bar all
around
(25mmx4.5mm) and
(19mmx3mm), 10mm
square bar as grill
welded horizontally @
100mm c/c, only catch
locking handle position
gap should 125mm, at
inner face of window
frame with F.I. clamp
75mmx3mm duly
embedded with
Cement Concrete
(1:2:4:) and mending
Three Nine
good the damages in/c
Thousand Thousand
all cost of charges for
One Hundred Two Hundred
Building fabrication and
21 5.08.12.02 sqm 2.924 3162.001 and 9245.691 and
Works manufacture by
Sixty-Two Forty-Five
welding, riveting, etc.
point Zero point Six Nine
supplying all essential
Zero One One
fittings like stopper,
handle, 3 nos catch
hook 300mm long
adjustable iron cleat,
50mm long pin hinge
in/c supplying, fitting,
fixing 18 BWG M.S.
sheet in position
welded to steel shutter
with Tee stiffener (2
nos.) made with 25mm
and 19mm flat bars
fitted to shutter frame
in Two equal part and
upper part should be
provided with 5mm
clear glass, vertically
in each shutter panel
and putty and painting
the window with two
coats of synthetic
enamel paint over a
coat of anticorrosive
priming, , etc for all
floors. all complete as
per direction of the
E-I-C

Painting to door and


window frames,
shutters and any type
of MS rod, FI bar, MS One
box, MS angle grill, Thousand
One Hundred
gate etc. in two coats Five Hundred
Building and Ninety
22 5.16.10.01 with synthetic enamel sqm 8.115 190.001 1541.858 and
Works point Zero
paint of best quality Forty-One
Zero One
and approved colour point Eight
over a coat of priming. Five Eight
Applying one vertical
and one horizontal

15 of 16 7/12/20, 10:15 PM
View Form https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?fo...

coat for each coat and


successive coat is to
be applied after drying
up of previous coat by
brush/roller/spray in/c
cleaning, washing,
rubbing, as necessary
and sand papering the
surface and necessary
scaffolding, etc. all
complete for all floors
i/c cost of all materials
as per direction of the
E-I-C.

44mm thick on an
average roof top
cement concrete
screed in proportion
(1:1.5:3) with Portland
Composite cement
(CEM II/AM, 42.5N)
and best quality sand
(minimum FM 2.5) and
12mm down well
graded crushed stone
chips broken from One Lakh
boulder ( LAA value Twenty-Seven
Six Hundred
not exceeding 33), Thousand
and
Building including Cement Four Hundred
23 5.12.18 sqm 195.173 653.001 Fifty-Three 127448.164
Works grouting, mixing and
point Zero
concrete, laying with Forty-Eight
Zero One
neat cement finishing point One Six
on the following day of Four
roof slab casting, cost
of all materials, labour
and transportation to
the site, finishing the
edges and corners,
curing for the requisite
period etc. all
complete as per
drawing, specification
and direction of the
E-I-C

Supplying fitting and


fixing steel door
shutter with 18 BWG
MS sheet/plain plate
Three
hinged to RCC Eleven
Thousand
columns reinforcement Thousand Six
Five Hundred
Building with Hundred and
24 5.08.20 sqm 3.246 3578.001 and 11614.191
Works 38mmx38mmx5mm Fourteen
Seventy-Eight
MS Angle and point One
point Zero
25mmx6mm flat bar Nine One
Zero One
stiffener etc. all
complete as per
drawing and direction
of E-I-C.

One Hundred One Hundred


and and
Additional
25 N.S.I.04 Unforeseen Works LS 1.000 194.001 Ninety-Four 194.001 Ninety-Four
Item
point Zero point Zero
Zero One Zero One

Seven Lakh
Twenty
Thousand
Grand Total: 720093.606 AND
Ninety-Three
point Six Zero
Six

This Bill of Quantities is Electronically Signed by Ms. Abdul Hakim on behalf of M/s. Abdul Hakim

16 of 16 7/12/20, 10:15 PM

You might also like