You are on page 1of 12

3/30/24, 11:53 AM View Form

M/S. Prianka Enterprise

Bill of Quantities

Bill of Quantities

Unit Total
Item Unit Price Total Price
Price Price
Item Code Measurement
Group Description of Item Quantity
no. (if Unit In figures In Figures
In Words In Words
any) (BDT) (BDT)
(BDT) (BDT)

Providing layout and carry over PWD Bench-Mark


Thirty-
(BM) at site from nearby BM pillar, Property lines,
Eight
existing ground level (EGL), formation ground
Two Thousand
level (FGL), highest flood levels (HFL), plinth
Hundred Eight
levels (PL), mean sea level (MSL), setting and
1 C/W N/A Sqm 194.400 200.001 point 38880.194 Hundred
marking all pillars, marker, pegs etc, showing and
Zero Zero and
maintaining reduced levels (RL?s) including
One Eighty
locating, establishing, protecting all public utilities
point One
within the premise of work and finally all to be
Nine Four
presented in black and white,

Mobilization and cleaning site before commencing


actual physical work and during contract period
and demobilization after completion of the Works
under contract accepted by Engineer,This work
Thirty-
shall also covers clayey cleaning and clearing,
Eight
cutting or filling, dressing the project area on and
Two Thousand
in the ground to an extent that all the events of
Hundred Eight
works of the project can be executed smoothly in a
2 C/W N/A Sqm 194.400 200.001 point 38880.194 Hundred
working environment with a particular attention on
Zero Zero and
safety and security in all respects, and to stockpile
One Eighty
the end outcome to a place for disposal agreed by
point One
the Engineer, where, payments are to be based on
Nine Four
ground area determined by the Engineer and be
proportionate to the percentage progress of work
under contract as a whole in all respects and
approved by the Engineer

Earth work in excavation in all kinds of soil for


foundation trenches including, layout, providing
center lines, local bench-mark pillars, leveling,
ramming and preparing the base, fixing bamboo
spikes and marking layout with chalk powder,
providing necessary tools and plants, protecting
Sixty-
and maintaining the trench dry etc,, stacking, Three
Eight
cleaning the excavated earth at a safe distance Hundred
Thousand
out of the area enclosed by the layout etc, all and Fifty
3 C/W N/A Sqm 194.400 350.001 68040.194 AND
complete and accepted by the Engineer, subject to point
Forty
submit method statement of carrying out Zero Zero
point One
excavation work to the Engineer for approval, One
Nine Four
However, Engineer?s approval shall not relieve
the contractor of his responsibilities and
obligations under the contract, Layout and marking
for earthwork in excavation in foundation accepted
by the Engineer-in-charge, [Plinth area of the
structure shall be considered for measurement]

Earth work in excavation in all kinds of soil for


foundation trenches including, layout, providing
center lines, local bench-mark pillars, leveling,
ramming and preparing the base, fixing bamboo Seventy-
spikes and marking layout with chalk powder, Five
providing necessary tools and plants, protecting Thousand
Three
and maintaining the trench dry etc,, stacking, One
Hundred
cleaning the excavated earth at a safe distance Hundred
and Fifty
4 C/W N/A out of the area enclosed by the layout etc, all Cum 214.710 350.001 75148.715 and
point
complete and accepted by the Engineer, subject to Forty-
Zero Zero
submit method statement of carrying out Eight
One
excavation work to the Engineer for approval, point
However, Engineer?s approval shall not relieve Seven
the contractor of his responsibilities and One Five
obligations under the contract, Earthwork in
excavation in foundation trenches up to 1,5 m
depth and maximum 10 m lead,

Supplying of straight and strong borrak bamboo


Four Twenty-
posts of having minimum 75 mm diameter
Hundred Four
althrough and driving the same vertically in the
5 C/W N/A Meter 60.000 400.001 point 24000.060 Thousand
ground up to required depth by any means
Zero Zero point
shaping the top of the post, all complete and
One Zero Six
accepted by the Engineer-in-charge,

6 C/W N/A Palisading work by supplying bitumen drum sheet Ls 5.000 6000.001 Six 30000.005 Thirty
walling tied with 20 BWG G,I, wire fixing the same Thousand Thousand

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 1/12
3/30/24, 11:53 AM View Form
with already driven borrak bamboo posts with half point point
split borrak bamboo runners at 450mm c/c Zero Zero Zero Zero
horizontally with iron nails, G,I wire etc, all One Five
complete and accepted by the Engineer, (Rate is
excluding the cost of bamboo post),

50 mm down graded picked jhama khoa


consolidation in foundation trenches by mixing the
same with best quality local sand (F,M, 1,2) in 2:1 Six Thirty
(khoa: sand) proportion to achieve minimum dry Thousand Thousand
7 C/W N/A density of 95percent with optimum moisture Ls 5.000 6000.001 point 30000.005 point
content (Modified proctor test) including breaking Zero Zero Zero Zero
and screening chips, laying and spreading in 150 One Five
mm layers uniformly,and compacting etc, all
complete and accepted by the Engineer-in-charge

One Lakh
Thirty-
Sand filling in foundation trenches and plinth with Eight
sand having F,M, 0,5 to 0,8 in 150mm layers Thousand
Five
including leveling, watering and compaction to Five
Hundred
achieve minimum dry density of 90% with optimum Hundred
8 C/W N/A Cum 277.090 500.001 point 138545.277
moisture content (Modified proctor test) by and
Zero Zero
ramming each layer up to finished level as per Forty-
One
design supplied by the design office only etc, all Five point
complete and accepted by the Engineer, Two
Seven
Seven

Five
Earth filling in foundation trenches and plinth in Thousand
150 mm layer with earth available within 90 m of One One
the building site to achive minimum dry density of Hundred Hundred
90percent with optimum moisture content and Fifty and
9 C/W N/A Cum 34.630 150.001 5194.535
(Modified proctor test) including carrying watering, point Ninety-
leveling, dressing and compacting to a specified Zero Zero Four
percentage each layer up to finished level etc, all One point Five
complete and accepted by the Engineer, Three
Five

Fourteen
Thousand
Supplying and laying of single layer polythene
Sixty Nine
sheet weighing one kilogram per 6,5 square meter
point Hundred
10 C/W N/A in floor or any where below cement concrete Sqm 249.850 60.001 14991.250
Zero Zero and
complete in all respect and accepted by the
One Ninety-
Engineer,
One point
Two Five

One Lakh
Forty-
One layer of brick flat soling in foundation or in Six Nine
floor with first class or picked jhama bricks Hundred Thousand
11 C/W N/A including preparation of bed and filling the Sqm 249.850 600.001 point 149910.250 Nine
interstices with local sand, leveling etc, complete Zero Zero Hundred
and accepted by the Engineer, One and Ten
point Two
Five

Twenty-
Mass concrete (1:3:6) in foundation or floor with
Nine
cement, sand (F,M, 1,2) and picked jhama chips
Thousand
including breaking chips, screening, mixing, laying, Seven
One
compacting to levels and curing for at least 7 days Thousand
Hundred
12 C/W N/A including the supply of water, electricity and other Cum 4.160 7000.001 point 29120.004
and
charges and costs of tools and plants etc, all Zero Zero
Twenty
complete and accepted by the Engineer, (Cement: One
point
CEM-II/A-M) Mass concrete in foundation (1:3:6)
Zero Zero
with cement, brick chips and sand of F,M, 1,2
Four

13 C/W N/A Reinforced cement concrete works with minimum Cum 17.950 12000.001 Twelve 215400.018 Two Lakh
cement content relates to mix ratio 1:1,5:3 having Thousand Fifteen
minimum f'cr = 30 MPa, satisfying a specified point Thousand
compressive strength f?c = 25 MPa at 28 days on Zero Zero Four
standard cylinders as per standard practice of One Hundred
Code ACI/BNBC/ASTM, Cement conforming to point
BDS EN-197-1 -CEM-I, 52,5N (52,5 MPa) / ASTM- Zero One
C 150 Type ? I, best quality Sylhet sand or coarse Eight
sand of equivalent F,M, 2,2 and 20 mm down well
graded stone chips conforming to ASTM C-33,
making and placing shutter in position and
maintaining true to plumb, making shutter water-
tight properly, placing reinforcement in position;
mixing with standard mixer machine with hopper,
fed by standard measuring boxes or mixing in
batching plant, casting in forms, compacting by
vibrator machine and curing at least for 28 days,
removing centering-shuttering after specified time
approved; including cost of water, electricity,
testing charges of materials and concrete

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 2/12
3/30/24, 11:53 AM View Form
cylinders as required, cost of all materials and
other charges etc, all complete, approved and
accepted by the Engineer-in- harge, (Rate is
excluding the cost of reinforcement and its
fabrication, placing, binding etc, and the cost of
shuttering & centering) a) Individual and
Combined footings,

Reinforced cement concrete works with minimum


cement content relates to mix ratio 1:1,5:3 having
minimum f'cr = 30 MPa, satisfying a specified
compressive strength f?c = 25 MPa at 28 days on
standard cylinders as per standard practice of
Code ACI/BNBC/ASTM, Cement conforming to
BDS EN-197-1 -CEM-I, 52,5N (52,5 MPa) / ASTM-
C 150 Type ? I, best quality Sylhet sand or coarse
sand of equivalent F,M, 2,2 and 20 mm down well
graded stone chips conforming to ASTM C-33,
One Lakh
making and placing shutter in position and
Seventy-
maintaining true to plumb, making shutter water-
Twelve Five
tight properly, placing reinforcement in position;
Thousand Thousand
mixing with standard mixer machine with hopper,
14 C/W N/A Cum 14.590 12000.001 point 175080.015 AND
fed by standard measuring boxes or mixing in
Zero Zero Eighty
batching plant, casting in forms, compacting by
One point
vibrator machine and curing at least for 28 days,
Zero One
removing centering-shuttering after specified time
Five
approved; including cost of water, electricity,
testing charges of materials and concrete
cylinders as required, cost of all materials and
other charges etc, all complete, approved and
accepted by the Engineer-in- harge, (Rate is
excluding the cost of reinforcement and its
fabrication, placing, binding etc, and the cost of
shuttering & centering), b) Padestals, Column,
Column Capitals, lift wall and walls upto Ground
Floor, Ground Floor,

Reinforced cement concrete works with minimum


cement content relates to mix ratio 1:1,5:3 having
minimum f'cr = 30 MPa, satisfying a specified
compressive strength f?c = 25 MPa at 28 days on
standard cylinders as per standard practice of
Code ACI/BNBC/ASTM, Cement conforming to
BDS EN-197-1 -CEM-I, 52,5N (52,5 MPa) / ASTM-
C 150 Type ? I, best quality Sylhet sand or coarse
sand of equivalent F,M, 2,2 and 20 mm down well
Eleven
graded stone chips conforming to ASTM C-33,
Lakh
making and placing shutter in position and
Eighty-
maintaining true to plumb, making shutter water-
Nine
tight properly, placing reinforcement in position; Twelve
Thousand
mixing with standard mixer machine with hopper, Thousand
Nine
15 C/W N/A fed by standard measuring boxes or mixing in Cum 99.160 12000.001 point 1189920.099
Hundred
batching plant, casting in forms, compacting by Zero Zero
and
vibrator machine and curing at least for 28 days, One
Twenty
removing centering-shuttering after specified time
point
approved; including cost of water, electricity,
Zero Nine
testing charges of materials and concrete
Nine
cylinders as required, cost of all materials and
other charges etc, all complete, approved and
accepted by the Engineer-in- harge, (Rate is
excluding the cost of reinforcement and its
fabrication, placing, binding etc, and the cost of
shuttering & centering), c) Floor / roof slab, T-
beam, L-beam and rectangular beam, tie beam,
lintel, stair case slab and steps etc, upto ground
floor, Ground Floor,

Centering and shuttering, including strutting, Sixteen


propping etc, (The formwork must be rigid enough Thousand
both in and out of plane, to make the concrete Five Five
surface true to the designed shape and size by Hundred Hundred
16 C/W N/A using necessary MS sheets of minimum 16 BWG, Sqm 33.130 500.001 point 16565.033 and Sixty-
angles of minimum size 40 mm x 40 mm x 5 mm, Zero Zero Five point
flat bars etc,) and removal of form after hardening One Zero
of the concrete for: a) Individual and combined Three
footing Three

Centering and shuttering, including strutting,


Seventy-
propping etc, (The formwork must be rigid enough
One
both in and out of plane, to make the concrete
Five Thousand
surface true to the designed shape and size by
Hundred Two
using necessary MS sheets of minimum 16 BWG,
17 C/W N/A Sqm 142.500 500.001 point 71250.143 Hundred
angles of minimum size 40 mm x 40 mm x 5 mm,
Zero Zero and Fifty
flat bars etc,) and removal of form after hardening
One point One
of the concrete for: b) Pedestal, column, column
Four
capital, lift wall and wall up to ground floor, Ground
Three
Floor,

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 3/12
3/30/24, 11:53 AM View Form

Centering and shuttering, including strutting,


One Lakh
propping etc, (The formwork must be rigid enough
Fifty-Five
both in and out of plane, to make the concrete
Five Thousand
surface true to the designed shape and size by
Hundred Eight
using necessary MS sheets of minimum 16 BWG,
18 C/W N/A Sqm 311.610 500.001 point 155805.312 Hundred
angles of minimum size 40 mm x 40 mm x 5 mm,
Zero Zero and Five
flat bars etc,) and removal of form after hardening
One point
of the concrete for: c) Formwork/shuttering, prop
Three
and necessary supports etc, (steel) Tie beam and
One Two
Lintels : Ground Floor, Ground Floor,

One Lakh
Centering and shuttering, including strutting, Fifteen
propping etc, (The formwork must be rigid enough Thousand
both in and out of plane, to make the concrete Five Two
surface true to the designed shape and size by Hundred Hundred
19 C/W N/A using necessary MS sheets of minimum 16 BWG, Sqm 230.550 500.001 point 115275.231 and
angles of minimum size 40 mm x 40 mm x 5 mm, Zero Zero Seventy-
flat bars etc,) and removal of form after hardening One Five point
of the concrete for: Floor and roof slab up to Two
Ground Floor, Three
One

Supplying, fabrication, and fixing to details as per


design : Ribbed or deformed bar reinforcement for
Reinforced Cement Concrete, produced and
marked in accordance with BDS ISO 6935 - 2:
2006 (or standard subsequently released from
BSTI) including straightening and cleaning rust, if
any, bending and binding in position with supply of
G,I, wires, splices or laps what so ever etc, Eighteen
complete in all respects and accepted by the Lakh Two
Engineer ( Measurement shall be recorded only on One Thousand
Standard Mass per Unit length of Bars, while, dia Hundred Six
of bars exceeds its standard), Grade 400 (RB 400 and Ten Hundred
20 C/W N/A Kg 16387.170 110.001 1802605.087
/RB 400W: complying BDS ISO 6935-2:2006) point and Five
ribbed or deformed bar produced and marked Zero Zero point
according to Bangladesh standard, with minimum One Zero
yield strength, fy (ReH)= 400 MPa but fy not Eight
exceeding 450 MPa and whatever is the yield Seven
strength within allowable limit as per BNBC/ ACI
318, the ratio of ultimate tensile strength fu to yield
strength fy, shall be at least 1,25 and minimum
elongation after fracture and minimum total
elongation at maximum force is 16% and 8%
respectively : up to ground floor, a) up to Plinth
Level & b) up to ground floor,

Brick works with first class bricks with cement


sand (F,M, 1,2) mortar (1:4) in exterior walls Thirty-
including filling the interstices with mortar, raking Five
out joints, cleaning and socking the bricks at least Thousand
Six
for 24 hours before use and washing of sand, Four
Hundred
necessary scaffolding, curing at least for 7 days Hundred
21 C/W N/A Cum 59.120 600.001 point 35472.059
etc, all complete including cost of water, electricity and
Zero Zero
and other charges (measurement to given as 250 Seventy-
One
mm width for one brick length and 375 mm for one Two point
brick and a half brick length) accepted by the Zero Five
Engineer-in-charge, (Cement: CEM-II/B-M) In Nine
ground floor: Upto Plinth, Ground floor

Damp proof course (DPC) (1:1,5:3) of cement


Sixty
concrete with cement, sand and stone chips
Five Thousand
including breaking of chips, screening, centering,
Thousand Seven
shuttering, casting, curing and finishing with a coat
22 C/W N/A Sqm 12.140 5000.001 point 60700.012 Hundred
of bitumen including the supply of water, electricity,
Zero Zero point
costs of tools & plants and other charges etc, all
One Zero One
complete and accepted by Engineer-in-charge,
Two
(Cement: CEM-II/B-M)

One Lakh
Minimum 6 mm thick cement sand (F,M, 1,2)
Forty-
plaster (1:4) with fresh cement to ceiling, R,C,C,
Seven
columns, beams, surface of stair case, sunshades,
Three Thousand
cornices, railings, drop wall, louvers, fins and
Hundred Seven
finishing the corners and edges including washing
23 C/W N/A Sqm 492.650 300.001 point 147795.493 Hundred
of sand, cleaning the surface, curing at least for 7
Zero Zero and
days, cost of water, electricity, scaffolding and
One Ninety-
other charges etc, all complete in all respect as
Five point
per drawing and accepted by the Engineer-in-
Four Nine
charge, (Cement: CEM-II/B-M) Ground floor,
Three

24 C/W N/A Minimum 12 mm thick cement sand (F,M, 1,2) Sqm 42.300 300.001 Three 12690.042 Twelve
plaster with neat cement finishing to dado with Hundred Thousand
cement (1:4) up to 150 mm including washing of point Six
sand, finishing the edges and corners and curing Zero Zero Hundred
at least for 7 days, cost of water, electricity, One and
scaffolding and other charges etc, all complete in Ninety
all respect as per drawing and accepted by the point

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 4/12
3/30/24, 11:53 AM View Form
Engineer-in-charge, (Cement: CEM-II/B-M), Zero Four
Ground floor, Two

One Lakh
Thirty-
Minimum 12 mm thick cement sand (F,M, 1,2)
Five
plaster (1:6) having with fresh cement to both
Three Thousand
inner and outer surface of wall, finishing the edges
Hundred Nine
and corners including washing of sand, cleaning
and Fifty Hundred
25 C/W N/A the surface, curing at least for 7 days, cost of Sqm 388.320 350.001 135912.388
point and
water, electricity, scaffolding and other charges
Zero Zero Twelve
etc, all complete in all respect as per drawing and
One point
accepted by the Engineer-in-charge, (Cement:
Three
CEM-II/B-M), Ground floor,
Eight
Eight

Supplying, fitting and fixing of rolling shutter of any


design and shape made of 24 SWG G,P, sheet
unit minimum 69 mm width having 10 mm and 12
mm dia circular folding at ends, rolled in machine,
locked together properly to form rolling shutter, top
of the shutter to be fitted with circular spring box
made of 26 BWG sheet, containing best quality
spring made in China, nutted with 38 mm G,I, pipe
at one end and the other end nutted to shutter
including fitting the G,I, pipe again with 375 mm x
300 mm x 6 mm pankha at ends with side guide Seventy-
Three
channel (side channel consist of 50 mm x 100 mm Five
Thousand
x 6 mm M,S, plate with 2 mm x 19 mm x 3 mm F,I, Thousand
Five
bar, middle channel consist of 2 mm x 150 mm x 6 Six
26 C/W N/A Sqm 21.600 3500.001 Hundred 75600.022
mm M,S, plate with 2 mm x19 mm x 6 mm fixed to Hundred
point
wall or column with clamps embedded in R,C,C, point
Zero Zero
part by cement concrete (1:2:4) including cutting Zero Two
One
holes (minimum 3 mm x 25 mm x 6 mm) mending Two
the damages, finishing, curing, bottom end of
shutter fitted to folded G,P, sheet (min 125 mm
width in two layers), which is again fitted to 25 mm
x 25 mm x 3 mm angle, providing handle with F,I,
bar 25 mm x 6 mm and locking arrangement in
both sides, painting two coats with approved
colour and brand of synthetic enamel paint over a
coat of priming etc, complete in all respect
accepted by the Engineer-in-charge, [Rate is
excluding the cost of painting]

Supplying, fitting and fixing of Aluminium sliding


window as per the U,S, Architectural Aluminium
Manufacturer?s Association (AAMA) standard
specification having 1,2 mm thick outer bottom
(size 75,50 mm, 32mm), 1,2 mm thick outer top
(size 75,50 mm, 16,80 mm), 1,2 mm thick shutter
top (size 33 mm,26,80, 22 mm), 1,2 mm thick
shutter bottom (size 60mm, 24,40 mm), 1,2 mm
thick outer side (size 75,50 mm,19,90 mm), 1,2
Sixty-One
mm thick sliding fixed side (size 31 mm, 26 Three
Thousand
mm),1,2 mm thick shutter lock (size 49,20 mm Thousand
Seven
26,20 mm) and 1,2 mm thick inter lock (size 34,40 Five
Hundred
27 C/W N/A mm, 32,10 mm) sections all aluminium members Sqm 17.640 3500.001 Hundred 61740.018
and Forty
(total weight kg/sqm) will be anodized to point
point
aluminium bronze/silver colour with a coat not less Zero Zero
Zero One
than 15 micron in thickness and density of 4 mg One
Eight
per square cm etc, including all accessories like
sliding door key lock, sliding door wheel, sliding
door mohiar, sliding door neoprene, bolts and nuts
including sealants, keeping provision for fitting 5
mm thick glass including labour charge for fitting of
accessories, making grooves and mending good
damages, carriage, and electricity complete in all
respect as per drawing and accepted by the
Engineer, Silver colour Window1, ii) Ground Floor

Sixty-One
Supplying, fitting and fixing in Aluminium door Three
Thousand
frames, windows, partitions and curtain wall Thousand
Seven
distortion free glass of approved quality and shade Five
Hundred
28 C/W N/A including cost of fitting fixing all necessary Sqm 17.640 3500.001 Hundred 61740.018
and Forty
accessories etc, complete in all respect as per point
point
drawing and accepted by the Engineer-in-charge, Zero Zero
Zero One
Silver colour Window 1, i) Ground Floor, One
Eight

Supplying, fitting and fixing window grills of any


Sixty-One
design made with approx 20 x 5 mm F,I, bar as Three
Thousand
inner members but no outer frame; including Thousand
Seven
fabricating, welding cost of electricity and tools Five
Hundred
29 C/W N/A and plants etc, complete for all floors accepted by Sqm 17.640 3500.001 Hundred 61740.018
and Forty
the Engineer, (Total weight per sqm should be point
point
approx 10 kg, and add or deduct, @ Tk, 152 for Zero Zero
Zero One
each kg, excess or less respectively) i) Ground One
Eight
Floor,

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 5/12
3/30/24, 11:53 AM View Form

38 mm thick artificial patent stone (1:1,5:3) flooring


with cement, best quality coarse sand (50%
quantity of Sylhet sand or coarse sand of One Lakh
equivalent F,M, 2,2 and 50% best quality local One
Five
sand of FM 1,2) and 12 mm down well graded Thousand
Hundred
stone chips, laying the concrete in alternate Seven
30 C/W N/A Sqm 203.520 500.001 point 101760.204
panels, compacting and finishing the top with neat Hundred
Zero Zero
cement and curing at least for 7 days in all floors and Sixty
One
including cost of water, electricity and other point Two
charges etc, all complete and accepted by the Zero Four
Engineer-in-charge,(Cement: CEM-II/B-M) In
ground floor, i) Ground Floor

Interior premium acrylic emulsion painting (silky


finish) of approved best quality and colour
delivered from authorized local agent of the
manufacturer(Berger luxury silk emulsion/Elite
super aclose silky finish/Asian royal luxury silk
emulsion or equivalent brand) in a sealed
container; applying to interior wall and ceiling with Two Lakh
surface preparation including cleaning drying, Six
making free from dirt, grease, wax, removing all Thousand
Three
chalked and scaled materials, fungus, mending One
Hundred
good the surface defects using sand paper and Hundred
31 C/W N/A Sqm 687.210 300.001 point 206163.687
necessary scaffolding; applying 1 coat of interior and Sixty-
Zero Zero
sealer of specified brand on prepared,surface; Three
One
then applying 1 coat of interior putty of specified point Six
brand for levelling, spot filling, crack filling and Eight
cutting by sand paper/zero water paper; finally Seven
applying 2 coats of interior emulsion paint by
spreading with ush/roller/spray machine &
necessary scaffolding etc,upto desired finishing,
elapsing specified time for drying or recoating; all
complete in all floors and accepted by the
Engineer-in-charge, i) Ground Floor,

Exterior premium acrylic emulsion paint of


approved best quality and color with high
performance against dirt picking tendency and
efflorosence resistence properties along with water
resisting properties and resistance properties
against fungi, fading and flaking from authorized
local agent of the manufacturer in a sealed
Fifty-
container; applying to exterior surface with surface
Eight
preparation including cleaning drying, making free
Thousand
from dirt, grease, wax, removing all chalked and Three
Two
scaled materials, fungus, mending good the Hundred
Hundred
32 C/W N/A surface defects using sand paper and necessary Sqm 194.160 300.001 point 58248.194
and
scaffolding; applying necessary exterior sealer of Zero Zero
Forty-
specified brand on prepared surface; then One
Eight
applying necessary exterior putty of specified
point One
brand for levelling, spot filling, crack filling and
Nine Four
cutting by sand paper/zero water paper; finally
applying 2 coats of exterior emulsion paint
spreading by brush/roller/spray & necessary
scaffolding etc, upto desired finishing, elapsing
specified time for drying or recoating; all complete
in all floors and accepted by the Engineer-in-
charge, i) Ground Floor,

Standard synthetic enamel paint of approved best Twenty-


quality and colour delivered from authorized local Three
agent of the manufacturer in a sealed container, Thousand
having high water resistance, high bondibility, Five
Three
flexibility property; using specified brand thinner Hundred
Hundred
applying to metallic or wooden surface by and
33 C/W N/A Sqm 78.480 300.001 point 23544.078
brass/roller/spray in 2 coats over single coat anti- Forty-
Zero Zero
corrosive coating including cleaning, drying, Four
One
making free from dirt, grease, wax, removing all point
chalked and scaled materials, all complete in all Zero
floors and accepted by the Engineer-in-charge, i) Seven
Ground Floor, Eight

Standard synthetic enamel paint of approved best


quality and colour delivered from authorized local Sixty-
agent of the manufacturer in a sealed container, Eight
having high water resistance, high bondibility, Thousand
Three
flexibility property; using specified brand thinner Three
Hundred
applying to metallic or wooden surface by Hundred
34 C/W N/A Sqm 227.940 300.001 point 68382.228
brass/roller/spray in 2 coats over single coat anti- and
Zero Zero
corrosive coating including cleaning, drying, Eighty-
One
making free from dirt, grease, wax, removing all Two point
chalked and scaled materials, all complete in all Two Two
floors and accepted by the Engineer-in-charge, i) Eight
Ground Floor, Roof

35 C/W N/A Supplying, fitting and fixing of 100 mm inside Rm 45.780 800.001 Eight 36624.046 Thirty-Six
diameter & wall thickness 2,7 mm - 3,4 mm best Hundred Thousand
quality uPVC rain water down pipe fitting, fixed in point Six

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 6/12
3/30/24, 11:53 AM View Form
position with head and shoes, bends, min,20 mm Zero Zero Hundred
width F,I, Bar clamp and nails, and including all One and
accessories such as round grating/domed roof Twenty-
grating, bands, sockets approved and accepted by Four
the Engineer- in- charge, i) Ground Floor, Roof point
Zero Four
Six

Twenty-
Two
Eight Thousand
Hundred Nine
36 C/W N/A Drain Work Cum 28.700 800.001 point 22960.029 Hundred
Zero Zero and Sixty
One point
Zero Two
Nine

Eight Eight
Hundred Hundred
37 C/W N/A Dismantling work L/S 1.000 800.001 point 800.001 point
Zero Zero Zero Zero
One One

Eight Eight
Hundred Hundred
38 C/W N/A Building Name Plate L/S 1.000 800.001 point 800.001 point
Zero Zero Zero Zero
One One

Eight Eight
Hundred Hundred
39 C/W N/A Site Cleaning L/S 1.000 800.001 point 800.001 point
Zero Zero Zero Zero
One One

Eight Eight
Hundred Hundred
40 C/W N/A Unseen Work L/S 1.000 800.001 point 800.001 point
Zero Zero Zero Zero
One One

ROAD WORK : Providing layout and carry over


PWD Bench-Mark (BM) at site from nearby BM Sixty-Six
pillar, Property lines, existing ground level (EGL), Five Thousand
formation ground level (FGL), highest flood levels Hundred One
(HFL), plinth levels (PL), mean sea level (MSL), and Fifty Hundred
41 C/W N/A Sqm 120.330 550.001 66181.620
setting and marking all pillars, marker, pegs etc, point and
showing and maintaining reduced levels (RL?s) Zero Zero Eighty-
including locating, establishing, protecting all One One point
public utilities within the premise of work and Six Two
finally all to be presented in black and white,

Mobilization and cleaning site before commencing


actual physical work and during contract period
and demobilization after completion of the works
under contract to be accepted by the Engineer-in-
charge, This work shall also cover cleaning and
clearing, cutting or filling, dressing the project area
Two Thirty
on and in the ground to an extent that all the
Hundred Thousand
events of works of the project can be executed
and Fifty AND
42 C/W N/A smoothly in a working environment with a Sqm 120.330 250.001 30082.620
point Eighty-
particular attention on safety and security in all
Zero Zero Two point
respects, and to stockpile the end outcome to a
One Six Two
place for disposal agreed by the Engineer-in-
charge, where, payments are to be based on
ground area determined by the Engineer-in-charge
and be proportionate to the percentage progress
of work under contract as a whole in all respects
and approved by the Engineer-in-charge

Thirty Thirty
Thousand Thousand
43 C/W N/A Temporary Labour Shed L/S 1.000 30000.001 point 30000.001 point
Zero Zero Zero Zero
One One

44 C/W N/A Earth work in excavation in all kinds of soil for Sqm 120.330 250.001 Two 30082.620 Thirty
foundation trenches including, layout, providing Hundred Thousand
center lines, local bench-mark pillars, leveling, and Fifty AND
ramming and preparing the base, fixing bamboo point Eighty-
spikes and marking layout with chalk powder, Zero Zero Two point
providing necessary tools and plants, protecting One Six Two
and maintaining the trench dry etc,, stacking,
cleaning the excavated earth at a safe distance
out of the area enclosed by the layout etc, all
complete and accepted by the Engineer, subject to
submit method statement of carrying out
excavation work to the Engineer for approval,
However, Engineer?s approval shall not relieve

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 7/12
3/30/24, 11:53 AM View Form
the contractor of his responsibilities and
obligations under the contract, Layout and marking
for earthwork in excavation in foundation accepted
by the Engineer-in-charge, [Plinth area of the
structure shall be considered for measurement]

Mechanical compaction of earth beyond plinth


area, required for pre-approved specific Ten
engineering purpose in 150 mm layers including Thousand
Six
levelling, watering and consolidation each layer Eight
Hundred
with chain dozer, grader, roller etc, to achieve Hundred
45 C/W N/A Cum 18.050 600.001 point 10830.018
minimum dry density of 95percent with optimum and Thirty
Zero Zero
moisture content (modified proctor test) up to point
One
finished level all complete and accepted by the Zero One
engineer-in-charge subjected to submission of the Eight
method statement,

Earth work in road embankment up to a lift of 1,5


m in all kinds of soil including cutting and throwing
earth in layers not exceeding 150 mm in thickness,
breaking clods up to 40 mm size in each layer, Thirty-Six
Four
ramming, leveling and dressing as per required Thousand
Hundred
side slope and alignment with earth borrowed from One
46 C/W N/A Cum 90.250 400.001 point 36100.090
the road side govt, acquired land for any leads and Hundred
Zero Zero
maintaining the embankment true to level and side point
One
slopes as per profiles for one year from the date of Zero Nine
completion including making dug, bailing, profiling
etc, complete and accepted by the Engineer-in-
charge,

Seven
Sand filling in foundation trenches and plinth with
Thousand
sand having F,M, 0,5 to 0,8 in 150mm layers
Five Five
including leveling, watering and compaction to
Hundred Hundred
achieve minimum dry density of 90 with optimum
47 C/W N/A Cum 15.040 500.001 point 7520.015 and
moisture content (Modified proctor test) by
Zero Zero Twenty
ramming each layer up to finished level as per
One point
design supplied by the design office only etc, all
Zero One
complete and accepted by the Engineer,
Five

Providing compacted sub-base course with well


graded material of crushed well burnt picked
Nine
jhama / 1st class brick bats and sand (FM 0,8)
Thousand
with mixing proportion 2 : 1 having compacted
Six
thickness made as per specification including local Four
Hundred
handling, spreading uniformly to proper grade Hundred
and
48 C/W N/A camber and super elevation, packing, rolling Cum 24.070 400.001 point 9628.024
Twenty-
properly with 8 to 10 ton capacity power driven Zero Zero
Eight
road roller and watering properly for compaction of One
point
100 MDD (standard) blinding with sand including
Zero Two
cost of fuel, lubricants, spares, maintenance,
Four
driver etc, all complete and accepted by the
Engineer-in-charge,

Seven
Thousand
Supplying and laying of single layer polythene
Sixty Two
sheet weighing one kilogram per 6,5 square meter
point Hundred
49 C/W N/A in floor or any where below cement concrete Sqm 120.330 60.001 7219.920
Zero Zero and
complete in all respect and accepted by the
One Nineteen
Engineer,
point
Nine Two

Brick works of width one brick or one and a half


brick length with first ,bricks in cement sand (F,IM,
1,2) mortar (1,6) in superstructure including raking
out joints, filling the interstices with mortar Six
One
cleaning and soaking the bricks at least for 24 Thousand
Thousand
50 C/W N/A hours before use and washing of send necessary Cum 0.300 6000.001 point 1800.000
Eight
scaffolding curing at least for 7 days etc, all Zero Zero
Hundred
complete (measurement to given as 250 mm width One
for one brick length and 375 mm for brick length
and accepted by the Engineer,( (Cement: CEM-
11/A-M) In ground floor

Minimum 12 mm thick cement sand (F,M, 1,2) One


plaster with neat cement finishing to plinth wall Thousand
Three
(1:4) with cement up to 150 mm below ground Two
Hundred
level with neat cement finishing including washing Hundred
and Fifty
51 C/W N/A of sand, finishing the edges and corners and Sqm 3.650 350.001 1277.504 and
point
curing at least for 7 days, cost of water, electricity Seventy-
Zero Zero
and other charges etc, all complete in all respect Seven
One
as per drawing and accepted by the Engineer, point Five
(Cement: CEM-II/A-M) Ground floor Zero Four

52 C/W N/A Providing expansion joints across the R,C,C, road Sqm 13.990 1200.001 One 16788.014 Sixteen
pavement with 20 mm gap between the adjacent Thousand Thousand
panels, Supplying dowel bars of size 12 mm dia Two Seven
and 600 mm long M,S rod placed 750 mm c/c, 300 Hundred Hundred
mm of the bar being fixed within one slab keeping point and

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 8/12
3/30/24, 11:53 AM View Form
remaining portion the bar free within the adjacent Zero Zero Eighty-
slab being inserted in 20 mm dia and 300 mm long One Eight
P,V,C, pipe embedded in the slab, inside of pipe point
fully greased, filling the gap between the slabs Zero One
(with admixture) of hot bitumen and coarse sand Four
(F,M, 2,2) in proportion of 2:1, finishing the top with
bitumen, spreading coarse sand over the joint, all
complete as per plan, drawing and accepted by
the Engineer-in-charge,

Reinforced cement concrete works with minimum


cement content relates to mix ratio 1:1,5:3 having
minimum f'cr = 30 MPa, satisfying a specified
compressive strength f?c = 25 MPa at 28 days on
standard cylinders as per standard practice of
Code ACI/BNBC/ASTM, Cement conforming to
BDS EN-197-1 -CEM-I, 52,5N (52,5 MPa) / ASTM-
C 150 Type ? I, best quality Sylhet sand or coarse
sand of equivalent F,M, 2,2 and 20 mm down well Two Lakh
graded stone chips conforming to ASTM C-33, Fifty-Two
making and placing shutter in position and Thousand
Twelve
maintaining true to plumb, making shutter water- Seven
Thousand
tight properly, placing reinforcement in position; Hundred
53 C/W N/A Cum 21.060 12000.001 point 252720.021
mixing with standard mixer machine with hopper, and
Zero Zero
fed by standard measuring boxes or mixing in Twenty
One
batching plant, casting in forms, compacting by point
vibrator machine and curing at least for 28 days, Zero Two
removing centering-shuttering after specified time One
approved; including cost of water, electricity,
testing charges of materials and concrete
cylinders as required, cost of all materials and
other charges etc, all complete, approved and
accepted by the Engineer-in-charge, (Rate is
excluding the cost of reinforcement and its
fabrication, placing, binding etc, and the cost of
shuttering & centering), Road

Supplying, fabrication, and fixing to details as per


design : Ribbed or deformed bar reinforcement for
Reinforced Cement Concrete, produced and
marked in accordance with BDS ISO 6935 - 2:
2006 (or standard subsequently released from
BSTI) including straightening and cleaning rust, if
Eight
any, bending and binding in position with supply of
Lakh
G,I, wires, splices or laps what so ever etc,
Ninety-
complete in all respects and accepted by the
One Six
Engineer ( Measurement shall be recorded only on
Hundred Thousand
Standard Mass per Unit length of Bars, while, dia
and Ten Nine
54 C/W N/A of bars exceeds its standard), Grade 400 (RB 400 Kg 8153.810 110.001 896927.254
point Hundred
/RB 400W: complying BDS ISO 6935-2:2006)
Zero Zero and
ribbed or deformed bar produced and marked
One Twenty-
according to Bangladesh standard, with minimum
Seven
yield strength, fy (ReH)= 400 MPa but fy not
point Two
exceeding 450 MPa and whatever is the yield
Five Four
strength within allowable limit as per BNBC/ ACI
318, the ratio of ultimate tensile strength fu to yield
strength fy, shall be at least 1,25 and minimum
elongation after fracture and minimum total
elongation at maximum force is 16% and 8%
respectively : up to ground floor,

55 E/W N/A CONCEALED CONDUIT POINT WIRING ( BYA) Point 29.000 1100.001 One 31900.029 Thirty-
(WITHOUT SWITCH) Concealed conduit wiring for Thousand One
following point looping at the switch board with One Thousand
earth terminal with IC - 2x1,5 sqmm PVC insuated Hundred Nine
cable ( BYA ) & IC - 2x1,5 sqmm PVC insulated point Hundred
FCC ( BYA ) Green Yellow bi - colour including Zero Zero point
circuit wiring ( From SDB to Switchboard ) with IC - One Zero Two
2x2,5 sqmm PVC insulated cable ( BYA ) & IC - Nine
225 sqmm PVC insulated ECC ( BYA ) ( Green
Yellow bi - colour ) through PVC conduit tone
conduit from switch board to common point on
ceiling is considered to draw 3 pair of cable ) of
reputed manufacturer of minimum 25 mm dia &
1,7 mm wall copper, thickness complete with 18
SWG GP sheet / PVC switch board pull box with
3mm thick ebonite sheet cover , fixing materials
etc ( without switch ) as required including
mending the damages good , All electrical
contacts shall be of brass connected through
connector or soldering ( no twisting shall be
allowed ) and cables shall be manufactured and
tested according to IEC BS VDE standard along
with relevant BDS standard as per detailed
specification mentioned in Annexure - 1 , The work
shall be carried out as per direction & approval of
the Engineer In Charge, Cable manufacturer (s)
must have valid type test certificate (within last
seves years) from internationally accredited

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 9/12
3/30/24, 11:53 AM View Form
laboratory (like CPRI, KEMA des accepted /
approved by the Engineer In Charge, Light /
exhaust or wall bracket fan point, Fan point

Concealed conduit wiring with the following PVC


insulated and stranded cable (BYA) & PVC
insulated green/white coloured ECC wire (BYA)
through PVC conduit of reputed manufacturer)
complete with 18 SWG GP sheet pull box with
3mm thick ebonite sheet cover, fixing materials,
other accessories etc, as required including
mending the damages good, All electrical contacts
shall be of brass/copper connected through
One
connector or soldering ( no twisting shall be Seventy-
Thousand
allowed) and cables shall be manufactured and Seven
One
tested according to relavent IEC/BDS/BS/VDE Thousand
56 E/W N/A RM 70.000 1100.001 Hundred 77000.070
standards and as per detailed specification point
point
mentioned in Annexure-A, The work shall be Zero
Zero Zero
carried out as per direction/approval/acceptance of Seven
One
the Engineer,Cables manufactured by BRB/
Paradise/BBS/Poly/ Supersign / Fecto Industries
(Citizen)/ Evana/Khawaja (777 Energy
Cable)/MEP/RR/Singer/Macro/
Transcom(Transtec) or equivalent approved by the
Engineering-in-Charge, 1C-2x2,5 sq,mm,(BYA)
cable with 2,5 sq,mm (BYA) ECC wire through
PVC pipe of minimum inner dia 16 mm having wall
thickness of 1,5 mm

Concealed conduit wiring with the following PVC


insulated and stranded cable (BYA) & PVC
insulated green/white coloured ECC wire (BYA)
through PVC conduit of reputed manufacturer)
complete with 18 SWG GP sheet pull box with
3mm thick ebonite sheet cover, fixing materials,
other accessories etc, as required including
mending the damages good, All electrical contacts
shall be of brass/copper connected through
One
connector or soldering ( no twisting shall be Thirty-
Thousand
allowed) and cables shall be manufactured and Three
One
tested according to relavent IEC/BDS/BS/VDE Thousand
57 E/W N/A RM 30.000 1100.001 Hundred 33000.030
standards and as per detailed specification point
point
mentioned in Annexure-A, The work shall be Zero
Zero Zero
carried out as per direction/approval/acceptance of Three
One
the Engineer,Cables manufactured by BRB/
Paradise/BBS/Poly/ Supersign / Fecto Industries
(Citizen)/ Evana/Khawaja (777 Energy
Cable)/MEP/RR/Singer/Macro/
Transcom(Transtec) or equivalent approved by the
Engineering-in-Charge, 1C-2x10 sq,mm,(BYA)
cable with 10 sq,mm (BYA) ECC wire through PVC
pipe of minimum inner dia 20 mm having wall
thickness of 1,5 mm

GANG SWITCH, Providing & fixing 250 volt 5/6


amps (minimum) Concealed type following
switch/switch socket Manufactured / Assembled
and tested in accordance with IEC / VDE / NEMA /
BS / JIS along with relevant BDS IEC standard , Five Three
mounted on required size 18 SWG galvanized Hundred Thousand
58 E/W N/A plain sheet board Plastic Board ( Self - Each 6.000 500.001 point 3000.006 point
extinguishing 650 degree centigrade ) of 76,2 mm Zero Zero Zero Zero
, ( 3 inch ) depth, All electrical contacts shall be of One Six
brass/copper, Assembled and made in
BANGLADESH/CHINA/INDIA/TURKEY/VIETNAM,
Four gang switch, One gang switch & one 5/10
Amps pin socketcombined

Five Two
GANG TYPE FAN REGULATOR Assembled and Hundred Thousand
59 E/W N/A made in Each 4.000 500.001 point 2000.004 point
BANGLADESH/CHINA/INDIA/TURKEY/VIETNAM Zero Zero Zero Zero
One Four

SOCKET OUTLETS, Providing & fixing 250 volt


single phase 3 - pin combined switch socket outlet
( surface / Concealed type ) Manufactured /
Assembled and tested in accordance with IEC /
Five Three
VDE / NEMA / BS / JIS along with relevant BDS
Hundred Thousand
IEC standard , mounted on required size 18 SWG
60 E/W N/A Each 6.000 500.001 point 3000.006 point
galvanized plain sheet board Plastic Board ( Self -
Zero Zero Zero Zero
extinguishing 650 degree centigrade ) of 76,2 mm
One Six
, ( 3 inch ) depth , ( Manufacturer shall have
certificate of standard which they follow )
13/15/16/20 Amps, Assembled and made in
BANGLADESH/CHINA/INDIA/TURKEY/VIETNAM

61 E/W N/A Supplying, fitting and fixing of the 250 V, A,C, Each 4.000 4000.001 Four 16000.004 Sixteen
capacitor type ceiling fan, with regulator and other Thousand Thousand

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 10/12
3/30/24, 11:53 AM View Form
accessories etc, (1400 mm sweep capacitor type : point point
Millet/G,E,C,/Singer or equivalent,) & all complete Zero Zero Zero Zero
as per direction of the Engineer in charge: One Four

Providing and fixing of following axial flow A,C


capacitor type wall mounted exhaust fan complete
with blade, steel frame standard wall louver Two Eight
shutter, PVC insulated connecting wire etc Thousand Thousand
62 E/W N/A complete as required including cutting wall and Each 4.000 2000.001 point 8000.004 point
mending good the damages as per direction of the Zero Zero Zero Zero
Engineer-in-charge (12inch) Ehaust fan plastic One Four
body (Foreign made approved by the Engineering-
in-Charge)

Braket light Fittings Light source : Ix9W LED, Two Two


Material : SS pipe ( Da - 20mm , thick - 1,2mm ) & Thousand Thousand
SS Sheet body, MS Sheet , Glass , 1-230m , H - Five Five
63 E/W N/A 200mm , P - 150min, GLORIA cat no , GWHI - Each 1.000 2500.001 Hundred 2500.001 Hundred
2503-2863, Energy Cat No - 30007, Commo Cat point point
No - HDR1 - GWH4-03, Asha Cat No - ACS - RS - Zero Zero Zero Zero
1223 657, Crescent - CB - 2028 1 or equivalent, One One

Tube Light Fittings Light source 20W T - 8 LED Two


tube, Material : MS Sheet , Design Acrylic ( thick Thousand Twenty
2,5mm ), 1-1240mm B - 60mm 11-106mm, Gloria Five Thousand
64 E/W N/A cat no - GTF ( LED ) 755x1x20W, Energy EMC - Each 8.000 2500.001 Hundred 20000.008 point
43002, Cosmo cat no - RDTC1-11F - 03, Asha Cat point Zero Zero
No, ACS - ILS 317x1x40W, Cracant - CTI,S - Zero Zero Eight
68x1x40 Watt or equivalent, One

Ceilling mounted Soucer light Light source 7W Twenty-


Three
LED Bulb, Material : MS Shoct , Brass aloy , Glass Four
Thousand
Size : D - 313mm 11-12mm, Gloria cat no - GCLF Thousand
65 E/W N/A Each 8.000 3000.001 point 24000.008
640 LED CFL - 7 Energy EPSI - 9023, Anha Cat point
Zero Zero
No, ACS - P3652, Crescant - CPM - 423 - P - BLK Zero Zero
One
or equivalent Eight

SINCLE PHASE DISTRIBUTION BOARD (SPDB)


Providing and fixing single phase distribution
board (SPDB) [concealed / surtacel] having the
followi omponen ts and specification: 1, Steel
board : Approximate size: 20inchx 15inchx4inch,
MS sheet : I8SWG with hinged type door and
locking arrangement duly painted with powder
coating with epoxy polyester resin on all surfaces
of board (gray / off-white) etc, ln front side there
will be tempered thick fiber glass of minimum 8
mm thickness with rubber gaskers to observe the
inside arrangemenl, 2, Copper bar: Approximate Five Five
size: 10inchx 1inchx 3mm (2 nos) and 6inchx Thousand Thousand
66 E/W N/A 1inchx 3mm, (I no) mounted on insulator at both Each 1.000 5000.001 point 5000.001 point
ends, capacity: 60- I 00A, 3, 1 No, DPMCB(main Zero Zero Zero Zero
control) and following nos,SpMCB, DpMCB and One One
SPMCB Manufactured / Assembled and tested in
accordance with relevant BDS IEC 60898-t:2016
and IEC / VDE / NEMA / BS / JIS standard,
Minimum breaking capacity 6/10 KA with thermal
overcunent and instantaneous electromagnetic
short circuit release, 4, Loop Cable Ifrom
phase,bar to SPMCB(circuit and power)] Size: lC-
I x2,5 sq mm (BYM) with DPMCB and SpMCBs
accepted / approved by the Engineer-in-charge, 8-
way SPDB Incoming: 1x50A DP MCB (10 KA)
Outgoing : 8x5-10A SP MCB (10 KA)

Twenty-
Twelve
Four
Thousand
Thousand
67 E/W N/A Lightning Arrester Set 2.000 12000.001 point 24000.002
point
Zero Zero
Zero Zero
One
Two

Providing & fixing 25,4 mm ( l inch) dia 457 mm ( I


5 ti) long solid copper rod with 6,6 mm thick 150
mm x l50 mm copper made base with sharp end
top, fixed on the top of 2,0inch( 2,5 - 3 mm thick ) Four
Twenty-
dia l0 feet long Gl pole by necessary accessories Hundred
Seven
The pole shall fixed on parapet wall with and Fifty
68 E/W N/A Per meter 60.000 450.001 27000.060 Thousand
necessary CC work and other accessories for point
point
anesting lightning as per plan (enclosed) and as Zero Zero
Zero Six
per direction ofthe Engineer [Fig:421], Providing & One
drawing no-2 HDBC wire through 12,7 mm (7r) dia
C l pipe including htting, fixing the G,l, pipe in wall
or column complete as required,

https://www.eprocure.gov.bd/resources/common/ViewBOQForms.jsp?formId=4732570&userId=45947&nture=Works&tenId=877243&procMtd=… 11/12
3/30/24, 11:53 AM View Form

Earthing Earthing the electrical installation with 40


mm (1,5inch) dia c,l, pipe (earth electrode) having
6,35 mm, dia hole across the pipe at 305 mm,
interval securely bonded by soldering with 2 nos,
ofNo-2 SWG HDBC earth leads (at the top ofthe
Three Three
electrode) with its protection by 20 mm, (3/4inch)
Thousand Thousand
dia G,l, pipe up-to plinth level run at a depth of
69 E/W N/A Each 1.000 3000.001 point 3000.001 point
609,6 mm (2 ft) below G,L up-to main board to be
Zero Zero Zero Zero
eanhed including necessary connecting copper
One One
sockets, bolts, nuts, etc, complete for maintaining
earth resistance within I ohm, IFig : 4,191 Depth of
bonom of main electrode at 31242 mm, (102,5 ft)
from CL & length ofelectrode J0480 mm, (100 ft)
(For Lighting Arrester)

FIRE EXTINGUISHER DRY CHEMICAL


POWDER TYPE Supply and fixing of the following
capacities multi purpose ABC dry chemical powder
stored pressure type with manometer system fire
extinguisher suitable for repeated use complete
with wall bracket , Nitrogen ( N2 ) cartridge , easy
refilling system etc, as per sample accepted &
Five Five
approved by the Engineer in Charge, Mono
Thousand Thousand
Ammonium Phosphate ( minimum 40 percent )
70 E/W N/A Each 1.000 5000.001 point 5000.001 point
based ABC dry chemical agent & has a moisture -
Zero Zero Zero Zero
proof , anti - caking properties , Working pressure
One One
12 BAR minimum & Test pressure 25 BAR
minimum , Proper fire rating ( as per NFPA 10 - BS
/ EN ) according to the capacity of the extinguisher
Manufacturer's certificate shall have to be
submitted if needed Also sample of the dry
chemical powder will be tested by the proper
authority in Bangladesh if needed, 5 Kg capaciy

FIRE EXTINGUISHER CARBON - DI - OXIDE


TYPE Supply and fixing of the following capacities
Carbon - di - Oxide stored pressure type with
manometer system fire extinguisher suitable for
repeated use complete with wall bracket , CO ,
cartridge , easy refilling system etc, as per sample Five Five
accepted & approved by the Engineer in Charge, Thousand Thousand
71 E/W N/A Working pressure : 12 BAR minimum & Test Each 1.000 5000.001 point 5000.001 point
pressure : 25 BAR minimum , Proper fire rating ( Zero Zero Zero Zero
as per NFPA 10 / BS / EN ) according to the One One
capacity of the extinguisher , Manufacturer's
certificate shall have to be submitted if needed ,
Also sample of the Carbon - di - Oxide will be
tested by the proper authority in Bangladesh if
needed 5 Kg , Capacity,

Seventy-
Two Lakh
Forty-
Five
Thousand
Grand
7245442.118 Four
Total:
Hundred
and
Forty-Two
point One
One Eight

This Bill of Quantities is Electronically Signed by Mr. Md. Alam on behalf of M/S. Prianka Enterprise