You are on page 1of 17

Name of Work: Construction of Training Centre, Boundary Wall, Main gate, Internal Road and Drainage System and

etc. at Faridpur Dairy farm.


1
(Package No. LDDP/W-106), Tender ID. No. 721334
Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Civil work 01.1.4.3 "Supplying and providing of First aid box with necessary materials/medicine (hygienic gown, thermometer, adhesive Each 1 16,215.000
dressings, antiseptic solutions, bandages, cotton balls or swaps, emergency blanket, gloves, hand sanitizer, ice pack, 16,215.0
saline etc ). All complete as per direction of Engineer-in -charge
2 Civil work 1.6 Providing layout and carry over PWD Bench-Mark (BM) at site from nearby BM pillar, Property lines, existing SqM 403 12,090.000
ground level (EGL), formation ground level (FGL), highest flood levels (HFL), plinth levels (PL), mean sea level 30.0
(MSL), setting and marking all pillars, marker, pegs etc. showing and maintaining reduced levels (RL's) including
3 Civil work 1.7 Mobilization and cleaning site before commencing actual physical work and during contract period and SqM 362 71,676.000
locating, establishing, protecting all public utilities within the premise of work and finally all to be presented in black 198.0
demobilization after completion of the works under contract to be accepted by the Engineer-in-charge. This work
shall also cover cleaning and clearing, cutting or filling, dressing the project area on and in the ground to an extent
4 Civil work 01.1.6 Providing and maintenance one project profile signboards to be placed at a suitable place of the site including SqM 3.75 12,146.250
that all the events of works of the project can be executed smoothly in a working environment with a particular 3,239.0
submission of proposals for the materials of the signboards and text layout containing 3D picture, safety instructions,
project information with security light etc to the Engineer-in-charge for approval which will be positioned as
5 Civil work 02.1 & 02.1.2 Earth work in excavation in all kinds of soil for foundation trenches including layout, providing center lines, local CuM 125 19,125.000
directed by the Engineer-in-charge and removing the same on completion of the works or as instructed by the 153.0
bench-mark pillars, levelling, ramming and preparing the base, fixing bamboo spikes and marking layout with chalk
powder, providing necessary tools and plants, protecting and maintaining the trench dry etc., stacking, cleaning the
Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m lead -
excavated earth at a safe distance out of the area enclosed by the layout etc. all complete and accepted by the

6 Civil work 02.1.1 Layout and marking for earthwork in excavation in foundation accepted by the Engineer-in-charge. [Plinth area of SqM 54.48 980.640
the structure shall be considered for measurement] 18.0
7 Civil work 2.17 "Mechanical compaction of earth beyond plinth area, required for pre-approved specific engineering purpose in 150 CuM 33.04 6,872.320
mm layers including levelling, watering and consolidation each layer with chain dozer, grader, roller etc. to achieve 208.0
minimum dry density of 95% with optimum moisture content (modified proctor test) up to finished level all
8 Civil work 03.1.1 One layer brick flat soling in foundation or in floor with first class/picked jhama bricks (BDS 208) including SqM 312.08 156,040.000
complete and accepted by the engineer-in-charge subjected to submission of the method statement. 500.0
preparation of bed and filling the interstices with local sand, leveling etc. complete and accepted by the Engineer-in-
charge
9 Civil work 3.4 & 3.4.1 Lean / blinding concrete (1:3:6) in foundation or in floor with cement, sand (F.M. 1.2) and picked jhama brick chips CuM 1.03 7,881.560
including breaking of chips, screening, mixing, laying, compacting to required level and curing for at least 7 days 7,652.0
including the supply of water, electricity, costs of tools & plants and other charges etc. all complete and accepted by
Lean / blinding concrete in foundation(1:3:6)with cement, brick chips and sand of F.M. 1.2 -
the Engineer-in-charge.(Cement: CEM-II/B-M)

10 Civil work 2.13 Earth filling in foundation trenches and plinth in 150 mm layer with earth available within 90 m of the building site CuM 90.93 17,185.770
to achive minimum dry density of 95% with optimum moisture content (Modified proctor test) including carrying 189.0
watering, leveling, dressing and compacting to a specified percentage each layer up to finished level etc. all complete
11 Civil work 02.10.1 Sand filling in foundation trenches and plinth with sand having minimum F.M. 0.5 in 150 mm layers including CuM 132 141,108.000
and accepted by Engineer-in-charge. 1,069.0
leveling, watering and compaction to achieve minimum dry density of 95% with optimum moisture content
(Modified proctor test) by ramming each layer up to finished level as per design supplied by the design office only,
12 Civil work 3.6 & 03.6.1 Damp proof course (DPC) (1:1.5:3) of cement concrete with cement, sand and picked jhama brick chips or stone SqM 126 184,716.000
all complete and accepted by the Engineer-in-charge. 1,466.0
chips including breaking of chips, screening, centering, shuttering, casting, curing and finishing with a coat of
bitumen including the supply of water, electricity, costs of tools & plants and other charges etc. all complete and
75mm thick damp proof course(1:1.5:3)with cement, Sylhet sand (F.M-2.2) and stone chips. -
accepted by Engineer-in-charge. (Cement: CEM-II/B-M)

13 Civil work 3.7 Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor or any SqM 216 9,936.000
where below cement concrete complete in all respect and accepted by Engineer-in-charge. 46.0
14 Civil work 4.1 Brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:6) in foundation and plinth, filling the CuM 8.9 64,756.400
joints/interstices fully with mortar, racking out the joints, cleaning and soaking the bricks at least for 24 hours before 7,276.0
use and curing at least for 7 days etc. all complete including cost of water, electricity and other charges and accepted
15 Civil work 4.16 "125 mm brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:4) and making bond with SqM 243.49 278,065.580
by the Engineer-in-charge. (Cement: CEM-II/B-M) 1,142.0
connected walls including necessary scaffolding, raking out joints, cleaning and soaking the bricks for at least 24
hours before use and washing of sand, curing at least for 7 days in all floors including cost of water, electricity and
" -
other charges etc. all complete and accepted by the Engineer-in-charge. (Cement: CEM-II/B-M) In ground floor

16 Civil work 4.16 "125 mm brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:4) and making bond with SqM 82.24 96,056.320
connected walls including necessary scaffolding, raking out joints, cleaning and soaking the bricks for at least 24 1,168.0
hours before use and washing of sand, curing at least for 7 days in all floors including cost of water, electricity and
" -
other charges etc. all complete and accepted by the Engineer-in-charge. (Cement: CEM-II/B-M)1st floor

17 Civil work 6.6 & 6.6.3 "Supplying, fitting and fixing country made glazed wall tiles complying BDS ISO 13006: 2015, irrespective of color SqM 61.43 110,635.430
&/or design, with 20 mm thick cement sand (F.M. 1.2) mortar (1:3) base and raking out the joints with white cement 1,801.0
including cutting, laying and hire charge of machine and finishing with care etc. including cost of water, electricity
" -
and other charges complete in all respect and accep. by the Engineer-in-charge.(Cement: CEM-II/A-M).
Wall tiles more than 250 mm x 400 mm & less than or equal to 300 mm x 600 mm in sizes -

18 Civil work 6.2 & 06.2.2 Supplying, fitting and fixing country made mirror polished homogeneous floor tiles complying BDS ISO 13006: Sqm 180.76 314,341.640
2015, water absorption ≤ 0.5%, modulus of rupture (MOR) ≥ 27 N/mm2, irrespective of color &/or design, with 20 1,739.0
mm thick cement sand (F.M. 1.2) mortar (1:4) base and raking out the joints with white cement including cutting and
-
laying the tiles in proper way and finishing with care etc. all complete and accepted by the Engineer-in-charge.

GP (mirror polished) 500 mm x 500 mm floor tiles -

19 Civil work 6.3 & 06.3.1 "Supplying, fitting and fixing country made homogeneous matt finished/ rustic floor tiles complying BDS ISO SqM 13.38 22,344.600
13006: 2015, water absorption ≤ 0.5%, modulus of rupture (MOR) ≥ 27 N/mm2, irrespective of color &/or design, 1,670.0
with 20 mm thick cement sand (F.M. 1.2) mortar (1:4) base and raking out the joints with white cement including
" -
cutting and laying the tiles in proper way and finishing with care etc. all complete and accepted by the Engineer-in-

Matt or rustic floor tiles of size 400 mm x 400 mm and below -

20 Civil work 6.1 & 6.10.1 Supplying, fitting and fixing country made GP homogeneous stair tiles having non skidding offsets, complying BDS SqM 4 5,624.000
ISO 13006: 2015, water absorption ≤ 0.5%, modulus of rupture (MOR) ≥ 27 N/mm2, irrespective of color &/or 1,406.0
design, with 20 mm thick cement sand (F.M. 1.2) mortar (1:4) base and raking out the joints with white cement
-
including cutting and laying the tiles in proper way and finishing with care

Glazed stair tiles having size of width 250 mm to 300 mm and length 300 mm -

21 Civil work 6.15 & 6.15.1 Supplying, fitting and fixing 20mm to 25mm thick machine made cement pavement tiles having minimum SqM 217.93 251,927.080
compressive strength of 27 MPa, irrespective of color &/or design, with 20 mm thick cement sand (F.M. 1.2) mortar 1,156.0
(1:4) base and making the joints carefully in true straight line including cutting, laying and hire charge of machine
-
and finishing with care etc. including water, electricity and other charges complete in all respect and accepted by the

Pavement tiles of size 300 mm x 300 mm -

22 Civil work 7.2 & 07.2.1 Reinforced cement concrete works with minimum cement content relates to mix ratio 1:2:4 having maximum water CuM 75.71 963,334.040
cement ratio.40 and minimum f'cr = 30.5 MPa, satisfying a specified compressive strength f'c = 22 MPa at 28 days 12,724.0
on standard cylinders as per standard practice of Code ACI/BNBC/ASTM, cement conforming to BDS EN-197-1-
-
CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type ? I, best quality Sylhet sand or coarse sand of equivalent F.M. 2.2

Individual & combined footing, pile cap, raft/mat, floor slab and foundation beam up to plinth level -

23 Civil work 07.2.2 Pedestals, column, column capital, lift wall and RCC wall up to ground floor CuM 21.29 277,962.240
13,056.0
24 Civil work 07.2.3 "Floor / Roof slab, T-beam, L-beam and rectangular beam, Tie beam, lintel, stair case slab and steps etc. up to CuM 48.59 624,721.630
ground floor 12,857.0
" -

25 Civil work 07.2.4 "Cornice, railing, drop wall, louver, fins, sunshade, false ceiling, waffle and ribbed floor slab etc. up to ground floor CuM 1.02 13,655.760
13,388.0
" -

26 Civil work 7.12 & 7.12.1 "Centering and shuttering, including strutting, propping etc. (The formwork must be rigid enough both in and out of SqM 55.48 31,512.640
plane, to make the concrete surface true to the designed shape and size by using necessary MS sheets of minimum 16 568.0
BWG, angles of minimum size 40 mm x 40 mm x 5 mm, flat bars etc.) and removal of form for
" -

Individual & combined Footing -


27 Civil work 7.12.2 In raft/mat/floor slab up to plinth level SqM 11.89 6,789.190
571.0
28 Civil work 7.12.3 Foundation beam SqM 109.01 52,978.860
486.0
29 Civil work 7.12.4 Pedestal, column, column capital, lift wall and wall up to Ground floor SqM 173.42 89,658.140
517.0
30 Civil work 7.12.5 Tie beam and lintel: ground floor SqM 14.49 7,752.150
535.0
31 Civil work 7.12.6 Floor slab, T-beam upto roof floor up to ground floor. SqM 348.79 198,461.510
569.0
32 Civil work 7.12.9 Sunshade, false ceiling: ground floor SqM 16.91 9,029.940
534.0
33 Civil work 7.12.10 Stair case slab and steps up to ground floor SqM 2.4 1,310.400
546.0
34 Civil work 8.1.3 "Grade 500 (B500DWR: complying BDS ISO 6935-2:2016 / ASTM A615) ribbed or deformed bar produced and Kg 18693 1,757,142.000
marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 500 MPa and whatever is the 94.0
yield strength within allowable limit as per BNBC/ ACI 318, the ratio of ultimate tensile strength fu to actual yield
" -
strength fy, shall be at least 1.25 and minimum elongation after fracture and minimum total elongation at maximum

35 Civil work 11.1 & 11.1.5 Supplying and making door and window frames (Chowkat) for all floors in/c wall side grove cutting, moulding by CuM 0.40 105,734.000
& 11.1.5.1 CNC machine or any other means with matured seasoned wood of required size including painting two coats of coal 264,335.0
tar to the surface in contact with wall, fitting and fixing in position etc. all complete and accepted by the Engineer-in-
-
charge. (All sizes of wood are finished).

Frame made from seasoned Jessore & Other Local Teak (10,573.40) -

Upto Size 0'-2.5" x 0'-6" (finished) -

36 Civil work 11.2.2 Supplying, fitting and fixing M.S. flat bar clamp of 150 mm x 38 mm x 6 mm size having bifurcated ends to door Each 56 7,056.000
and window frames with necessary rowel plug, screws etc. including cutting grooves in chowkat if necessary etc. all 126.0
complete and accepted by the Engineer-in-charge.
37 Civil work 11.3.1 Supplying, fitting and fixing double leaf door frame for all floors made with 38mm x 38 mm x 6 mm M.S. angle meter 17.3 12,456.000
fitted with 150 mm long 6 nos. iron clamps of same size M.S. angle (with one end bifurcated) with the vertical 720.0
members of the frame, fixing the frame in wall with cement concrete (1:2:4), mending good the damages, fixing 6
38 Civil work 11.3.2 Supplying, fitting and fixing double leaf door frame for all floors made with 38mm x 38 mm x 6 mm M.S. angle meter 25.39 17,671.440
Nos. of 100 mm long iron hinges with the vertical members of the frame all complete including making holes in 696.0
fitted with 150 mm long 6 nos. iron clamps of same size M.S. angle (with one end bifurcated) with the vertical
members of the frame, fixing the frame in wall with cement concrete (1:2:4), mending good the damages, fixing 6
39 Civil work 12.1 & "Supplying, fitting and fixing of 38 mm thick well matured seasoned (moisture content should be between 12% to Sqm 8.46 116,113.500
Nos. of 100 mm long iron hinges with the vertical members of the frame all complete including making holes in 13,725.0
12.1.3.1 16%) solid wood single leaf door shutter having stile section 100m x 38mm, top rail section 125mm x 38mm, lock
rail section 100mm x 38mm and bottom rail section 225mm x 38mm (made from minimum 250mm wide plank)
" -
with 4nos 100mm long, 3mm thick hinge, 12mm dia 250mm long tower bolt, 12mm dia 200mm long socket bolt,

Chattogram Teak (SS Fittings) -

40 Civil work 12.3 & "Supplying, fitting and fixing 38mm thick well matured seasoned (moisture content should be between 12 to 16%) Sqm 9.52 144,037.600
12.3.3.1 wooden double leaf panel door shutters having stile and top rail section 100mm x 38mm, lock rail section 125mm x 15,130.0
38mm and bottom rail section 225mm x 38mm, panelling 38mm thick both sides raised (made from minimum
" -
250mm wide plank) with 4nos 100mm long, 3mm thick hinge, 12mm dia 250mm long tower bolt, 12mm dia 200mm

Chattogram Teak (SS Fittings) -

41 Civil work 12.19 & Supplying, fitting and fixing of well matured wooden louver shutter (Chattogram Teak) having 75.50 mm x 38 mm Sqm 0.83 13,982.180
12.19.1 size all around frame and inner horizontal wooden louver blade 65 mm x 20 mm spaced @ 38 mm c/c, fitted and 16,846.0
fixed with 2 nos hinges, 1 no handle and 2 nos magnetic catch. All complete in all floors and accepted by the
-
Engineer-in-charge.

With SS Fittings -
42 Civil work 12.21 & "Supplying, fitting and fixing mortice door lock with lever handle of approved quality including all necessary tools Each 3 3,636.000
12.21.1 and accessories etc. all complete approved and accepted by the Engineer-in-charge. 1,212.0
" -

Standard Quality -

43 Civil work 12.22 & "Supplying, fitting and fixing rim/round door lock of approved quality including all necessary tools and accessories Each 5 5,140.000
12.22.1 etc. all complete and accepted by the Engineer-in-charge. 1,028.0
" -

Standard Quality -

44 Civil work 12.23 & "Supplying, fitting and fixing best quality heavy type 19 mm dia and 300 mm long hasp bolt including cutting Each 3 1,638.000
12.23.2 grooves in door shutter and frames, screws etc. all complete approved and accepted by the Engineer-in-charge. 546.0
-

" -

SS Hasp Bolt -

45 Civil work 12.25 Supplying, fitting and fixing approved best quality foreign made stainless steel/brass door viewer/eye viewer from Each 1 589.000
12 mm to 20 mm diameter with adjustable thickness suitable for fitting from 37 mm to 50 mm thick door shutter in/c 589.0
all necessary work as per direction and accepted by the Engineer-in-charge.
46 Civil work 13.5.2 "Supplying, fitting and fixing window grill made of 12 mm x 12 mm M.S. solid bar @ 100mm c/c with outer frame SqM 28.15 78,594.800
of 38 mm x 6mm F.I. bar and 25 mm x 6 mm F.I. bar for clamp as per design including fabrication, welding, cost of 2,792.0
electricity workshop charges, labour charges for fitting and fixing grills in position, local carriage charges, cutting
" -
grooves, mending good the damages, tools and plants, finished with anti-corrosive painting (Red-Oxide) etc.

47 Civil work 13.9 Supplying, fitting and fixing MS verandah grill as per design and shape with 75 mm x 50 mm MS box with 3mm SqM 0.9 4,146.300
wall thickness middle rail (horizontal), 50 mm x 25 mm vertical rail with 3mm wall thickness @ approx. 750 mm c/c 4,607.0
, 25x25 mm MS box with 2 mm wall thickness horizontally @100mm c/c as per required measurement including
48 Civil work 14.4 & 14.4.2 "Supplying, fitting and fixing of aluminium sliding doors as per the U.S. Architectural Aluminium Manufacturer's Sqm 3.25 12,174.500
cutting grooves in wall up to 150 mm depth and mending good the damages with C.C. (1:1.5:3), finished with anti- 3,746.0
Association (AAMA) standard specification and BDS 1879:2014 having minimum 1.2 mm thick outer bottom (size
75.50 mm, 17.79 mm, 0.47 kg/m), minimum 1.2 mm thick outer top (size 75.50 mm, 28.50 mm, 0.705
" -
kg/m) ,minimum 1.2 mm thick shutter top (size 33 mm, 26.80 mm, 0.42 kg/m), minimum 1.2 mm shutter bottom

Powder coated to any colour -

49 Civil work 14.9 & 14.9.1 "Supplying, fitting and fixing of equal diamension frame(EDF) section aluminium sliding window with mosquito SqM 25.09 160,626.180
& 14.9.1.1 mesh as per the U.S. Architectural Aluminium Manufacturer's Association (AAMA) standard specification and BDS 6,402.0
1879:2014 having 1.5 mm thick outer bottom (size 91.50 mm, 38.00 mm), 1.5 mm thick outer top (size 91.00 mm,
" -
28.70 mm), 1.5 mm thick shutter top (size 65.00 mm, 27.30 mm), 1.5 mm thick shutter bottom (size 72.20 mm,

Size up to: 1524 mm x 1372 mm -

Anodized to any colour -

50 Civil work 14.11 & "Supplying, fitting and fixing of aluminium top hung/casement windows as per the U.S. Architectural Aluminium Sqm 2.09 23,322.310
14.11.1 Manufacturer's Association (AAMA) standard specification and BDS 1879:2014 having 1.5 mm thick casement 11,159.0
outer (size 38.86 mm, 36.36 mm, 0.395kg/m), 1.9 mm thick casement shutter (size 47.62 mm, 28.57 mm, 0.692
kg/m), and 1.245 mm thick shutter glass clip (size 15.87 mm, 27 mm, 0.188 kg/m) sections of all aluminium
" -

Anodized to any colour -

51 Civil work 14.16 & Supplying, fitting and fixing in Aluminium door frames, windows, partitions and curtain wall distortion free glass of SqM 30.48 44,897.040
14.16.1.1.1 approved quality and shade including cost of fitting fixing all necessary accessories etc. complete in all respect as per 1,473.0
drawing and accepted by the Engineer-in-charge.
-

5 mm thick tinted glass -

52 Civil work 14.16.4.2 10mm thick clear tempered glass SqM 1.38 5,851.200
4,240.0
53 Civil work 15.1.1 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to both inner-and outer surface of SqM 260 73,060.000
wall, finishing the corner and edges including washing of sand, cleaning the surface, curing at least for 7 days, cost 281.0
of water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and accepted by the
54 Civil work 15.1.2 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to both inner-and outer surface of SqM 566 168,668.000
Engineer-in-charge. (Cement: CEM-II/B-M) ground floor. 298.0
wall, finishing the corner and edges including washing of sand, cleaning the surface, curing at least for 7 days, cost
of water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and accepted by the
55 Civil work 15.1.2 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to both inner-and outer surface of SqM 176 54,736.000
Engineer-in-charge. (Cement: CEM-II/B-M) ground floor. 311.0
wall, finishing the corner and edges including washing of sand, cleaning the surface, curing at least for 7 days, cost
of water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and accepted by the
56 Civil work 15.11.1 Making groove in plaster on outside wall upto 50 mm X 6 mm size including scaffolding, curing etc. complete as per meter 175 4,725.000
Engineer-in-charge. (Cement: CEM-II/B-M) 1st Floor. 27.0
drawing and accepted by the Engineer-in-charge.
57 Civil work 16.1.1 Exterior standard acrylic emulsion paint of approved best quality and color having water resisting properties and SqM 305 79,605.000
resistance properties against fungi, fading & flaking delivered from authorized local agent of the manufacturer in a 261.0
sealed container; applying to exterior surface with surface preparation including cleaning, drying, making free from
58 Civil work 16.2.1 Interior standard acrylic emulsion paint (plastic or matt finish) of approved best quality and colour delivered from SqM 685 167,825.000
dirt, grease, wax, removing all chalked and scaled materials, fungus, mending good the surface defects using sand 245.0
authorized local agent of the manufacturer in a sealed container; applying to interior wall and ceiling with surface
preparation including cleaning drying, making free from dirt, grease, wax, removing all chalked and scaled
59 Civil work 16.3.1 Standard synthetic enamel paint of approved best quality and colour delivered from authorized local agent of the SqM 21.9 4,730.400
materials, fungus, mending good the surface defects using sand paper and necessary scaffolding; applying necessary 216.0
manufacturer in a sealed container, having high water resistance, high bondibility, flexibility property; using
specified brand thinner applying to metallic or wooden surface by brass/roller/spray in 2 coats over single coat anti-
60 Civil work 16.9.1 Standard French polishing to Wooden board surface by three coats over a coat of priming including putty, cleaning, SqM 40.61 16,528.270
corrosive coating including cleaning, drying, making free from dirt, grease, wax, removing all chalked and scaled 407.0
finishing and polishing with sand paper etc. all complete in all floors and accepted by the Engineer-in-charge.
61 Civil work 16.7.2 Epoxy enamel paint of approved quality and colour delivered from authorized local agent of the manufacturer in a SqM 41.96 18,168.680
sealed container; surface preparation including cleaning, drying, making free from dirt, grease, wax, removing all 433.0
chalked and scaled materials, fungus (if required must be treated with fungicidal solution) flaking paints, washing
62 Civil work 17.4 Average 100 mm thick finished lime terracing with 20 mm down graded first class brick chips (khoa), surki from 1st CuM 20.2 342,935.400
the surface with soap water/caustic soda, mending good the surface defects, smoothening the surface by putty, sand 16,977.0
class bricks and minimum lime content 500 kg per 2.83 cubic meter (stone lime brought at site, not being powdered
in open air and to be slaked in presence of engineer-in-charge and to be measured in volume three days after slaking
63 Civil work 10.6 Supply, fabrication and installation of hot rolled structural grade steel channel and angle in roof truss or any form of Kg 56 7,224.000
for using in the mix) in the proportion 7:2:2 (brick chips : surki : lime) including preparation of the mix on the 129.0
structure of any thickness conforming to ASTM A36 with a minimum yield strength of 250 MPa, including the cost
of testing, application of red/grey-oxide primer etc. (up to level-4) all complete as per drawing, specification and
Total Tk. 7529903.890
direction of Engineer-in-charge.

3 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Electrical works 1.6 & 1.6.1.1 Concealed conduit wiring for following point looping at the switch board with earth teRMinal with 1C-2x1.5 sqmm Point 96 128736.000
PVC insulated and sheathed stranded cable (BYM) & same size PVC insulated ECC (BYA) (Green / White color) 1,341.00
including circuit wiring with IC-2x2.5 sqmm PVC insulated and sheathed stranded cable (BYM) & same size PVC
2 Electrical works 1.6.1.2 Fan point Point 4 5364.000
insulated ECC (BYA) Green / White color through PVC conduit (one conduit from switch board to common point 1,341.00
3 Electrical works 1.6.1.1 Exit light & Evacuation light Point 8 10728.000
1,341.00
4 Electrical works 1.15 & Concealed conduit wiring with following PVC insulated and sheathed stranded cable (BYM) & PVC Insulated RM 850 338300.000
1.15.1.3 Green/ White coloured ECC wire (BYA) though PVC Conduit of reputed manufacturer complete with 18 SWG GP 398.00
sheet and pull box with 3mm thick ebonite sheet cover, fixing materials etc. as required including mending damages
5 Electrical works 1.15 & lC-2x2.5sqmm(BYM ) cable with 2.5sqmm (BYA) ECC wire through PVC pipe of minimum inner dia 16 mm RM 1050 305550.000
goods. all electrical contacts shall be of brass / copper connected though connectoror soldering ( no twisting shall be 291.00
1.15.1.2 having wall thickness of1.5mm
6 Electrical works 1.17.2.4 1C-4x10mm2 (NYY/2XY)Cable with 10mm2 (BYA) ECC wirw through PVC Pipe of minimum inner dia 40mm, RM 15 18690.000
wall thciness 2.2 mm. 1,246.00
7 Electrical works 1.18, "Providing & laying of the following PVC insulated & sheathed cable (NYY) / (XLPE) insulated & PVC sheathed RM 130 397670.000
1.18.1.12 & cable (2XY) with PVC insulated Green / Yellow bi-colour ECC wire (BYA) connecting at both ends, through PVC 3,059.00
1.18.1.12.1 pipe & accessories in the following manner. All electrical contacts shall be of brass / copper connccted through
In Katcha Ground" 0.000
connector or soldering (no twisting shall be allowed) and cables shall be manutbctured and tested according to IEC /

8 Electrical works 1.18.1.12.2 In Pucca Floor RM 25 82650.000


3,306.00
9 Electrical works 4.10 & Providing & fixing 250 volt single phase 3-pin combined switch socket outlet (surface/concealed type)manufactured Each 46 49036.000
4.10.1.1 and tested in accordance with relevent IEC/VDE/NEMA/BS/JIS Standerds mountented on required size 18 SWG 1,066.00
galvanized plain sheet board/plastic Board (self-extinguishing 650 Celcious) of 76.2 mm.3" depth. Assambeld &
10 Electrical works 4.11.2 & Providing & fixing 250 volt single phase universal combined switch socket outlet (surface/concealed type) Each 15 10725.000
made in Made in ENGLAND / GERMANY / JAPAN / USA or EU countries. 715.00
4.11.2.1 manufactured and tested in accordance with relevant IEC/VDE/NEMA/BS/JIS standers mounted on required size 18
SWG galvanized plain sheet board/ plastic board ( self-extinguishing 650°C ) of 76.2mm (3″) depth. Simple to be
11 Electrical works 4.12 & Gang Switch: Proividing & fixing of 250V, 6 amps (minimum) concealed type following switch /switch sockets Each 30 28500.000
approved be the Engineer. (Manufacture shall have certificate of stranded which they follow. (b)5-10 Amps (Made 950.00
4.12.1.2 manufactured and tested in accordance with relavent IEC/ VDE / NEMA / BS/ JIS standerd mounted on required
size 18 SWG galvanized plain sheet / PVC board ( Self-extinguishing 650 c of 76.2 mm (3") depth. all electrical
12 Electrical works 4.12.1.3 Three gang switch Each 25 36425.000
contacts shall be of brass / copper. ( Manufacturer shall have certification of standerd which they follow). Made In 1,457.00
13 Electrical works 4.13 & 4.13.1 Gang type Fan Regulator Made in ENGLAND / GERMANY / JAPAN / USA or EU countries. Each 4 6100.000
1,525.00
14 Electrical works 6.4.2.1 Supply & fixing of LED bath-room light fitting of the following features and model with all necessary elements such Each 4 12728.000
as driver, chips etc. complete. Model & sample shall be approved by the Engineer. Material: MS Sheet, Aluminium 3,182.00
Sheet, Acrylic (thick-12mm L-400mm, H-90mm, P-40mm GLORIA cat No.GLML. 2106 Energy+ Cat no-EPML-
15 Electrical works 6.5.2 & Supply & fixing of LED spot light fitting of the following features and model with all necessary elements such as Each 10 13470.000
10029 (small) Cosmo Cat No-BDTCL-LML-01 Asha Cat No- ACS-LBB-2837 or eqivalent 15 Watt fittings. 1,347.00
6.5.2.1.4 driver, chips etc. complete. Model & sample shall be approved by the Engineer.Round panel (Surface type)Material:
Alu Aloy, Acrylic; Gloria Cat No-GSDL-513Energy + cat No-EPPLLED-2006; Cosmo cat no-BDTCL-LSRPL-
16 Electrical works "6.5.3.5 & Supply & fixing of LED fittings spot light of following specification: Surface type: Cloria- GMSL 557; Energy + Each 17 51646.000
01Adex Cat No-AD SDL 830/840/865; Asha Cat no- ACS LPL-1451Megaman WLED-DSPLR-200-UL or 3,038.00
6.5.3.5.2" EPSL-49004Cosmo cat no-BDTCL-LSL-03; Asha Cat no-ACS LPS-1472 MS Device or equivalent
17 Electrical works 6.6.2 & Supply & fixing of LED tube / panel light fitting of the following features, size and model with all necessary Each 25 80925.000
6.6.2.2.2 elements such as driver, chips etc. complete. Model & sample shall be approved by the Engineer. Square panel: 3,237.00
Material - Aluminium aloy Acrylic; Gloria Cat no-CPL-703 Energy+ EPLLED-2001/ 2002; Cosmo Cat no-
18 Electrical works 6.7.2 & Supply & fixing of LED garden / gate light fitting of the following features and model with all necessary elements Each 10 96890.000
BDTCL-LPL-01 Asha Cat no-ACS-LTLS-1651; Adex Cat no-ADPLS-36 W 840 Megaman-MQL 1030; Walton: 9,689.00
6.7.2.25 such as driver, chips etc. complete. Model & sample shall be approved by the Engineer.Material: Cast Alurninium,
Acrylic; Dia: 170 mm, Height: 750mmCast Aluminium thickness - minimum 3 mm; Glorai cat no - GGDL - 352
19 Electrical works 6.8.3 & Supply & fixing of LED street light fitting of the following features and model with all necessary elements such as Each 4 45376.000
18w ENERGY+ model no - EPGL 24043; Cosmo-BDTCL-LBL-02 Asha cal no: ACS LGL-2745 or similar product 11,344.00
6.8.3.1.2 driver, chips etc. complete. Model & sample shall be approved by the Engineer. Glorai cat no- GLST. 1205: Energy
+ EPSTL-18001Cosmp BDTCL-LSTI-03; Asha Cat No.-ACS-LSL 2343 Muspana Cat No.MPSL 100DL or
20 Electrical works 3.1 & 3.1.4 Providing following seamless tubular pole fabricated with 4.76 mm (3/16") thick MS sheet having different sections Each 4 52284.000
equivalent products of SUNKO/ Annyesha/SHWASH/ Crescent or equivalent foreign made. 150 W 13,071.00
with 152.40 mm long MS reducing collar joint complete with MS base plate, top cover & duly painted with two
coats of superior quality paint over two prime coats of red oxide etc. as required. Total length-40 ft, Inner dia - 4
21 Electrical works 6.9.3.3 "Supply & fixing LED flood light fittings of following specifications:I50W Gloria Cat no - GLFL-905, Energy + Cat Each 2 18696.000
inch, length-20ft, thickness- 4mm, Inner dia - 3 inch, length - 5 ft, Base plate - 1.5 ft x 1.5 ft x 6 mm 9,348.00
No. EPFDL-17001Cosmo cat no- BDTCL-LFDL-04, Adex - AD FLE 150W865Asha Cat No. - ACS-LFL 2156
(150W) or cquivalent.
" 0.000

22 Electrical works 6.10 & Providing & fixing the water tight light fitting of following manufacturers model & catalogue number suitable U- Each 9 12438.000
6.10.1.2 type glass cover (minimum total height of fitting 310mm), G.I wire net guard, brass holder, earth terminal, necessary 1,382.00
wiring with 2 x 0.4 sq.mm stranded PVC insulated flexible FR cable etc. complete. suitable for LED lamp (except
23 Electrical works 14.76 Supply and installation of "Exit light" complete with recgchargeable battery and charge light and other necessary Each. 4 14724.000
lamp) as per sample accepted / approved by the Engineer.Material: Aluminium aloy Aluminium Sheet, MS Sheet, GI 3,681.00
accessories suitable for AC / DC power supply (220V single phase) as per NFPA 101.
24 Electrical works 14.77 Supply and installation of "Evacuation light" (directional sign) complete with recgchargeable battery and charge Each. 2 8590.000
light and other necessary accessories suitable for AC / DC power supply (220V single phase) as per NFPA 101. 4,295.00
25 Electrical works 7.2 & Supply, Installation, Testing & commissioning of split type room air-cooler comprising condensing and evaporating Each 7 934101.000
7 .2.1.3.2 units having cooling capacity as mentioned below based on indoor temperature 27º-30ºC DB / 19.5º-22ºC WB and 133,443.00
outdoor temperature 35º-40ºC DB at high speed condition suitable for installation & operation in tropicalized
0.000
country like Bangladesh & standard as mentioned below:

"OUTDOOR UNIT / CONDENSING UNIT 0.000

(l ). Type : Compact weather proof outdoor type condensing unit, (2). Compressor : Hermitically sealed reciptocating 0.000
/ rotary compressor, (3). Refrigerant : lntemationally accepted & recommended and most commonly used gas (CFC
free), (4). Blower motor : Welt balanced type direct driven centrifugal type blower fan, (5). Power supply : (5.1).
0.000
200-250 V, singte phase, 50 Hz AC supply [up to 30000 BTU/HR], (5.2). 380-440 v 3-phase, 50 Hz, AC supplv

"INDOOR UNIT / FAN COIL UNIT 0.000


Features : ( l). Direct expansion system fan coil unit with rvell halancerl direct drivcn centrif'lrgal type fan, (2). 0.000
Fancy & adjustable air circulating louver grill. removable & washable type filter, (3). Condensing water drain our
pV( flexible pipe with necessary insulation, (4). Thermostatic switch and remote control switch, (5). Sound level :
26 Electrical works 21.1 & Supplying & fixing AC capacitor type ceiling fan (without regulator) of following specification and size complete Each 4 15592.000
maximum 44 dB(A) al 1 meter Standard : Major component shall be rnanulacturered as per relevant intemational 3,898.00
21.1.1.1 with 305 mm (1ft.) long and 0.75-1.0″ dia, 2.3 mm thickness MS pipe down rod, tempered cast aluminium blades,
2.5 µf 400v AC capacitor ,canopy, double Z ball bearing, best quality silicon sheet core ,best quality copper made
27 Electrical works 21.4.1 Fan Clamp: Providing & fixing of Box-type Fan clamp made of 25.4mm x 6.35mm flat bar with 12mm dia M.S. Rod Each 4 684.000
super enamel wire , aluminium alloyed casting body having safety pin with power coated heat/ docu paint as 171.00
hook.
28 Electrical works 21.2 & 21.2.3 Providing and fixing of following axial flow A.C capacitor type wall mounted exhaust fan complete with blade, steel Each 3 4686.000
frame standard wall louver shutter, PVC insulated connecting wire etc. complete as required including cutting wall 1,562.00
and mending good the damage as per direction of the Engineer.I2" Exhaust fan plastic body (foreign made accepted/
29 Electrical works 4.3 & 4.3.1 Providing and fixing three phase distribution board (TPDB) [concealed / surface] having the following components Each 1 64276.000
approved by the Engineer). 64,276.00
and specifications: [Fig : 4.1] 1.Steel board : size 36"x30"x6" MS sheet:18SWG with hinged type door and locking
arrangement duly painted with powder coating with epoxy polyester resin on all surfaces of board (gray / off-white)
30 Electrical works 4.18 & 4.18.1 Supply & fixing of 18 SWG metal clad 500 volt 3 phase two way change over switch of following capacity complete Each 1 4049.000
etc. In front side there will be tempered thick fiber glass with rubber gaskets to observe the inside arrangement. 4,049.00
with moving & fixed copper contacts, copper buses, brass nuts and bolts, 3 mm thich ebonite sheet separators
insulators, operating handle etc. complete including necessary hammer painting on enclosure.60 - 100 Amps. rating
31 Electrical works 4.9 & 4.9.5 Supplying and fixing of almirah type 18 SWG metal board of depth 228mm (6") duly painted with powder coating SqM 2 13400.000
with epoxy polyester resin on all surfaces of board (gray / off-white) having built in push type / suitable locking 6,700.00
anangement including metal bridges of suitable size for fixing of all electrical control devices complete with suitable
32 Electrical works 4.4 & 4.4.1.1 Providing & fixing on a prepared board 250 yolt grade following singlepole miniature circuil breaker (SpMCBs) Each 40 31160.000
anchoring arrangement in wall / column and keeping provision for cable inlets and exits as required (only fiont 779.00
having minimum breakingcapacity 6-KA / I0 KA with thermal over-current and instantaneous electromagnetic short
circuit release provision as per BDS IEC and IEC / VDE / NEMA / BS / JIS standard. i) 5-40A SP MCB (6KA)
33 Electrical works 4.6 & 4.6.1 Providing & fixing on a prepared board 500 volt grade following Triple pole molded case circuit Breaker Each 4 29856.000
(TPMCCB) with thermal over-current and instantaneous electromagnetic short circuit release provision, 7,464.00
manufactured and tested in accordance with relavent IEC / VDE / NEMA / BS/ JIS along with relavant BDS IEC
34 Electrical works 4.7.1 Copper flat bar (5 nos): 4 nos 9" x l"x 3mm and I no 4" x l" x 4mm for earthing mounted on insulalor at both ends Each 1 2543.000
standerd. 15 - 100 Amps (minimum 10 KA) 2,543.00
individually.
35 Electrical works 4.22.8 Surge protection device (SPD) for protection of over-head Iine connected to LT line.Capaciry : 50 KA 4-pole with Set 1 54297.000
wiring and SPD box. Made in GERMANY / AUSTRALIA / SPAIN or product of EU countries 54,297.00
36 Electrical works 2.1.8 & POWER FACTOR IMPROVEMENT PANEL (PFI) Supply of following 415 volt, 3 phase, 50 Hz power factor Each 1 166265.000
2.1.8.1 improvement panel complete with TP bus bars and earth block, microprocessor controlled auto power factor 166,265.00
correction relay with digital PF reading display, capacitor bank, contactor, fuse, ON indicators for every stage of
0.000
capacitor bank (except directly connected one) etc. shall be manufactured & tested as per NEMA / VDE / IEC / JIS /

"For 100 KVA transformer (PFI capacity - 60 KVAR) 0.000

3 Nos. - 415V, l50A hard drawn electrolytic copper bus bar. I No. - 415V, 2.5 KVAR, 50 Hz TP power capacitor 0.000
bank with built in / separate discharge coil for connection directly with line through fuse. I No. - 4 | 5V, 2.5 KVAR,
50 Hz TP power capacitor bank with built in / separate discharge resistor. 5 No. - 415V. l0 KVAR,50 Hz TP power
37 Electrical works 4.19 & 4.19.6 Earthing System: Earthing the electrical installation with 40mm (1.5") dia G.I. pipe (Earth electrode) having 6.35mm Set 3 154608.000
caPac itor bank with built in / I No. - 415V, 5 KVAR, 50 Hz TP power capacitor bank with built in / separate 51,536.00
dia holes across the dia at 305mm interval securedly bonded with 2x2 SWG HDBC earth lead with washer, nuts,
bolts etc. sunk upto undermentioned depth and protection of earth lead by 20 mm dia G.I. pipe upto plinth level run
38 Electrical works 4.2 Construction of earthing inspection pit inside measurement 600 mm :i 600 mm with 250 mm thick brick in cement Each 3 22086.000
at a depth of 609.6mm (2 ft) below G.L. upto main board/test point to be earthed including necessary connecting 7,362.00
mortar (l:4) with l00mm thick RCC top slab ( I :2:4) with l7o re-enforcement 450 mm dia water sealed Cl man-hole
cover with locking anangement including necessary earth works' site filling and one brick flat soling 75 mm thick
39 Electrical works 5.7 & 5.7.6 Providing of following capacity multistage Bore-well Submersible water Pump Motor set manufactured according to set 1 151663.000
( I :3:6) base concrete for making inlet channel & l2mm thick (l:2) cement plastcr with neat finishing etc. all 151,663.00
relevant BDS standard and ISO 9906:2012. Crade 3B / DIN / NEMA / IEC / BS / VDE / JIS & ISO 9001:2015
standard. CE certitied / UL listed comprising of 2900 RPM, single/ three phase submersible rewindable type (oil /
40 Electrical works 21.22.3 & Providing & fixing 415V + 10 % , 50Hz three phase elechonics digital energy meter (KWH meter) steel body with Each 1 6587.000
water cooled ) motor having insulation: Class F & Protection : IP68 (minimum), suitable for operation at 230 /400 V 6,587.00
21.22.3.1 glass cover on prepared board inconformity with BDS IEC standard. l0- 100 Amps (Single Tariff)
41 Electrical works L.S Miscellaneous charges for obtaining permission for connection from DESA/DESCO/PDB/REB/Chief Electrical KW 45 90000.000
Advisor, Govt. of the Peoples Republic of Bangladesh including Security Deposit, HT metering fgees and licencing 2,000.00
Board fees etc.
42 Electrical works 10.3.2 Supply,installation,testing,commissioning multimedia projector including all necessary accessories & Each 1 54935.000
Wananty/Service Support of following technical speciflcation or equivalent: Projection lechnology: 3LCD 54,935.00
Technology, RGB liquid crystal shutter. LCD Panel: 0.59 inch with MLA (D9), lmage Size (Projected Distance): 33"
43 Electrical works 10.4 & Supply, installation, testing. commissioning multimedia projector screen (10'x7.5') including all necessary Each 1 20364.000
to 320" 1.68 m - 2.02 m ( 60 inch screen), Projector Lens: Optical, Lamp Type: UHE.210 W, 6,000 h durability, 20,364.00
10.4.5.2 accessories & Warranty/Service Support of following technical specificalion or equivalent: Motorized./ Electric
screen (Motorized 150" Diagonal)
44 Sound System 16.13.1 Supply, tnstallation, Testing & Commissioning of dual channel power amplifier including accessories of following Each 1 143091.000
Work technical specification or equivalent- Stereo Power Output: RMS (Dual Channels)- 8Ox2: 2l5W- 350W,4Ox2: 143,091.00
350W- 460W, Bridged Mono Power Output : RMS- 8Qx I : 700W- 950W, Frequency Response: 20Hz- 20 KHz,
45 Sound System 16.16.4 Supply, lnstallation, Testing & Commissioning of Wireless Microphones (Hand Held Type) of following technical Each 2 135322.000
Signal to Noise Ratio > 97 dB Total Harmonic Distortion (THD) <0.5%, Power Supply: 120 or 230 Vac 50Hz, 67,661.00
Work specification or equivalent- suitable for I transmitter, Preset with 16 selectable UHF channel, RF frequency range;
600 MHz-750MHz or any suitable carrier frequency range, Channel 16, Frequency Response: 50Hz-l8KHz,
46 Sound System 16.10 & Supply, Installation, Testing & Commissioning of Column / wall speaker ideal for airports, lounges, convention Each 3 72639.000
operating range 100m. CE Cenified/UL Listed Country of Origin: USA, UK, Japan. EU Countries; suitable for use 24,213.00
Work 16.10.3 centers, corporate boardrooms, hotels / hospitality, houses of worship, museums offrces, of patois, spaces schools,
theaters and theme parks, superior sound quantity, wide dispersion and smooth off-axis overage, superior sound
47 Sound System 16.28.2 Speaker cables, l2 AWG (copper made twin core shielded . PVC Jacket,PE Insulation. Dielectric srength: minimum Meter 150 22800.000
quality, wide dispersion and smooth off axis coverage, fast and easy installation of following technical specification 152.00
Work 500 Vac )
48 TV Line Work 4.15 & 4.15.1 TV socket (UK MEM/LEGRAND/GERMANY/ ENGLAND) Each 8 11344.000
1,418.00
49 TV Line Work TV Line 1.22.1.4 TV cable 40 4480.000
Work RG-11 112.00
50 TV Line Work 1.25 & 1.25.2 Providing & Iaying of following PVC pipe (besr quality PVC pipe of repured manufacturer) embedded in wall / RM 40 2000.000
column / ceiling / floor etc. with all accessories, l8 SWG GP sheet pull box with 3 mm ttrict ebonite street cover, 50.00
fixing materials etc. as required including mending the damages good. Minimum inner dia 20 mm & minimum wall
51 Intercom Work l7.l.1 Supply, installation, testing & commissioning of 6+8 line (extension capacity 24 line) digital PABX system. Basic Each 1 18017.000
thickness I .5 mm. 18,017.00
unit: 6+8 line PABX system; Hardware: (CPU card, T&T/ Land Line card, power supply unit & casing); Software:
System operating software & billing software; Features: Direct inward station access including necessary, AUTO /
52 Intercom Work 17.3.2.1 Supply, installation, testing & commissioning of single line telephone set for executive use with provision volume Each 3 7980.000
DISA (voice), CID (caller ID). card co-line card, etc. built in billing system automatic fax / phone switching key 2,660.00
up+ down, redial, flash etc.. including display with CID system (Min 30 Stations) complete.Suitable for use in
tropical country Iike Bangladesh complete with required accessories and in conformity to specified codes &
53 Internet Work 17.16.1 Supply. installation, testing & commissioning of router with following specification & features or equivalent as per Each 1 202575.000
specification of intemational standards & CE / UL /CSA certified. Model & sample to be approved by the Engineer 202,575.00
direction of the Engineer in charge.System features:Aggregate Throughput: 35 Mbps to 75 Mbps or above; Total
onboard WAN or LAN I0/100/1000 ports: 2; RJ-45-based ports: 2; SFP-based ports: I, Default memory double-data-
54 Internet Work 17.27 & Supply, installation, testing & commissioning of fiber optic cable (lndoor) with following specification or equivalent RM 70 8400.000
rate 3 (DDR3) error-conection-code (ECC) DRAM (Combined control/services/data planes): minimum 4 120.000
17.27.1 as per direction of the Engineer in charge.Specification:Armored single loose tube fiber optic cable (50 / 125 μm
multi-mode, 6-core) suitable for internal & extenal applications in ducts or intra-building links in campus
55 Fire works 14.1 & Supply & fixing the following capacities multi purpose ABC dry chemical powder stored pressure type with Each 5 9380.000
environments and having outer diameter of app. 6.5 mm and weight app. 35.0 kg / km etc.. complete with all 1,876.00
14.1.1.3 manometer system fire extinguisher suitable for repeated use complete with wall bracket, CO2 cartridge, easy
refilling system etc. as per sample accepted & approved by the Engineer. Mono Amonium Phosphate based 40%
56 Fire works 14.1.2.1 Supply & fixing the following capacities Carbon-di-Oxide type fire extinguisher suitable for repeated use complete Each 5 15515.000
ABC dry chemical agent & has a moisture-proof, anti-caking properties. Working pressure : 12 BAR minimum & 3,103.00
with wall bracket, discharge nozzle etc. as per sample accepted & approved by the Engineer.3 Kg. capacity.
57 Fire works 14.48 & Supply and installation of convcntional fire alarm control panel of following capacity with power supply unit, Each 1 86568.000
14.48.1 bateries and other accessories. The panel shall be complete with zone indicaling LED, fault indicarion and optional 86,568.00
telephonc jack erc. The panel shall have input 220V AC and output 24V DC. Panel shall be confirmed UL listed /
58 Fire works 14.49 Supply ard installation of conventional smoke delector complete with base. Shall be UL listed / FM approved. Shall Each 7 22813.000
FM approved.08 zonc capacity 3,259.00
have buih-in alarm LED. Powcr supply shall be 24VDC.
59 Fire works 14.5 Supply and installation of conventional heat detcctor complele with base. Shall be UL listed / FM approred. Shall Each 1 3259.000
have built-in alarm LED. Powcr supply shall be 24VDC. 3,259.00
60 Fire works 14.51 Supply and installation of convcntional type manual call poinl like break glass swilch or single action pull station Each 4 13852.000
complete with back box and all othcr accessories and consumables. Power supply shall be 24VDC. It shall bc UL 3,463.00
listcd / FM approved.
61 Fire works 14.78 & Surface conduit wiring with the following FPLR/ FPLP/ FPL type UL listed / FM Approved / LPCB Approved Meter 180 43020.000
14.78.1 cable. PVC lnsulation for each core shall be FR (Fire Rated) & Drain wire. shield (Aluminum Foil tape/ PET tape) 239.00
shall meet the minimum requircment as per NEC (National Eleclric Code) or NFPA 70 or BS. Jacket shall be Fire
Total Tk. 4470448.000
Rated. All electrical contacts shall be of brass / coppcr connected through connector or soldering (no twisling shall

4 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Sanitary works 26.01 & "Supplying, fitting and fixing of European type country made best quality glazed porcelain combi closet (two piece), Each 2 35418.000
26.01.6 including plastic seat cover with soft closing ,cistern system, water consumption 6 litre, siphon wash down/siphon jet 17,709.00
single or dual flushinging system which reduce water consumption, hygienic glaze in toilet bowl ,glaze in inner
" 0.000
waste line, round bowl, outlet range 280~305 mm.The sanitary ware shall conform BDS1162:2014. The glaze shall

0.000

"Approx. 702~ 750x 380~412 mm size, minimum 40.0 kg of weight, Equivalent to COTTO: C118 / RAK:Shino or 0.000
similar brand.
" 0.000

2 Sanitary works 26.05 & "Supplying, fitting and fixing of country made glazed vitreous standing bowl urinal. The sanitary ware shall conform Each 1 3436.000
26.05.01 BDS1162:2014. The glaze shall be thoroughly fused to body. The minimum thickness of body at any section shall be 3,436.00
5 mm. When assembled together and when examined from a distance of 60 cm, the outer surface shall not show to
" 0.000
the unaided eye, blemishes or defects in excess of those listed in BDS standard. The mean value of water absorption

Approx. 330 X 355 X 445 mm size, minimum 10.0 kg of weight 0.000

3 Sanitary works 26.13 & "Supplying of country made glazed vitreous W/H wash basin of any color including pedestal.The sanitary ware shall 26.13.2 5 20170.000
conform BDS1162:2014. The glaze shall be thoroughly fused to body. The minimum thickness of body at any 4,034.00
section shall be 5 mm. When assembled together and when examined from a distance of 60 cm, the outer surface
" 0.000
shall not show to the unaided eye, blemishes or defects in excess of those listed in BDS standard. The mean value of
26.13.2 Approx. 457 x 406 mm, minimum weight 15.3 kg 0.000

4 Sanitary works 26.19 & Supplying, fitting and fixing of 5 mm thick unframed super quality double coated mirror with all necessary fitting Sqm 1.67 2844.010
26.19.2 including making holes in walls and mending good the damages with cement mortar (1:4) etc. all complete approved 1,703.00
and accepted by the Engineer-in-charge.
0.000

Belgium Mirror, 5 mm thickness 0.000

5 Sanitary works 26.21 Supplying, fitting and fixing of super quality 600 x 125 mm white glass (plate) shelf having 5 mm thickness with Each 2 2020.000
fancy C.P. brackets, screws and frames including making holes in walls and mending good the damages with cement 1,010.00
mortar (1:4) etc. all complete approved and accepted by the Engineer- in charge.
6 Sanitary works 26.22 & Supplying, fitting and fixing of country made best quality towel rail/ring/shelf minimum 20 mm in dia with C.P. Each 3 2142.000
26.22.1 holder including making holes in walls and mending good the damages with cement mortar (1:4) etc. all complete 714.000
approved and accepted by the Engineer- in- charge.
0.000

C.P. towel ring/ 450 mm long single towel rail 0.000

7 Sanitary works 26.23 & Supplying, fitting and fixing of best quality toilet paper holder of standard size including making holes in walls and Each 2 576.000
26.23.1 mending good the damages with cement mortar (1:4) etc. all complete approved and accepted by the Engineer- in- 288.000
charge.
0.000

PVC toilet paper holder 0.000

8 Sanitary works 26.26 & Supplying, fitting and fixing of Push-Up type liquid soap dispenser to dispense 16 oz (.47 liters) of soap, detergent or Each 3 3975.000
26.26.1 lotion. Unit shall be fabricated of tamper resistant, chrome plated plastic, a translucent white polyethylene soap 1,325.000
container, and a corrosion resistant dispensing valve which can provide no more than 5 lbs (22.2 Newtons) pressure
0.000
and unit can be reloaded by unscrewing base from bracket collar, inverting unit, and unscrewing soap container in

Push-Up type liquid soap dispenser (local): standard quality 0.000

9 Sanitary works 26.27 & "Supplying, fitting and fixing of floor grating net in traps or in drains including making holes in walls/floors and Each 5 4920.000
26.27.5 mending good the damages with cement mortar (1:4) etc. all complete approved and accepted by the Engineer- in- 984.000
charge. of following type.
" 0.000

Approx. 125 mm x 125 mm stainless steel floor grating net 0.000

10 Sanitary works 26.30 & "Supplying, fitting and fixing of best quality surface mounted or conceal stop cock/angle stop cock (lever or round Each 16 18288.000
26.30.1 headed) with wall flange chromium plated. The faucet conforms BDS EN 200:2009. The faucet tap shall be free 1,143.000
from any leakage, permeation and other abnormalities. The water hammer value shall be 1.47 Mpa or under. The
" 0.000
faucet after it has been operated 100000 times it shall be free from a seat- leakage and shall satisfy the reverse flow

0.000

12 mm dia CP Concealed Stop Cock 0.000

11 Sanitary works 26.31 & "Supplying, fitting and fixing of best quality pillar cock made from copper or copper alloy, chromium plated Each 5 9400.000
26.31.5 materials. The faucet conforms BDS EN 200:2009. The faucet tap shall be free from any leakage, permeation and 1,880.00
other abnormalities. The water hammer value shall be 1.47 Mpa or under. The faucet after it has been operated
" 0.000
100000 times it shall be free from a seat- leakage and shall satisfy the reverse flow preventing performance. The

0.000

CP Single lever movig pillar cock 0.000

12 Sanitary works 26.43 & "Supplying different inside dia best quality uPVC soil, waste and ventilation pipe having specific gravity 1.35 - 1.45, meter 12.19 6594.790
26.43.1 wall thickness 2.5 mm - 3.0 mm, and other physical, chemical, themal, fire resistivity properties etc. as per BSTI 541.000
approved manufacturer standards or ASTM, BS/ISO/IS standards fitting and fixing in position with sockets, bends,
of uPVC Pipe with all accessories such as Round grating /domed roof grating bands, sockets etc. approved and
" 0.000

0.000

50 mm inside dia wall thickness 2.5 mm - 3.0 mm 0.000

13 Sanitary works 26.43.2 100 mm inside dia wall thickness 3.4- 4.0 mm meter 15.23 13158.720
864.000
14 Sanitary works 26.43.3 150 mm inside dia wall thickness 4.5 mm - 5.2 mm meter 65.52 103128.480
1,574.00
15 Sanitary works 26.46 & "Supplying different inside dia best quality CPVC pressure pipe for water supply having specific gravity 1.35 - 1.45, meter 15.29 3929.530
26.46.1 and other physical, chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer standards or 257.000
ASTM, BS/ISO/IS standards fitting and fixing in position with sockets, bends, with all accessories such as round
" 0.000
grating/domed roof grating, bends, sockets etc. approved and accepted by the Engineer-in charge.

0.000

12 mm dia wall thickness 2.8 mm - 3.3 mm 0.000

16 Sanitary works 26.46.3 25 mm dia wall thickness 3.4 mm - 4.0 mm meter 18.28 8061.480
441.000
17 Sanitary works 26.46.5 37 mm dia wall thickness 2.5 mm - 3.1 mm meter 4.57 3930.200
860.000
18 Sanitary works 26.46.6 50 mm dia wall thickness 3.0 mm - 3.9 mm meter 15 22095.000
1,473.00
19 Sanitary works 26.58 & Supplying, fitting and fixing of food graded plastic overhead water reservoir /tank including all necessary fittings, Each 1 29,728.0 29728.000
26.58.4 hardware and consumables etc. all complete approved and accepted by the Engineer- in- charge.
0.000

3000 liter capacity 0.000

20 Sanitary works 26.61 & Supplying, fitting and fixing of 12 mm dia connection pipe approved and accepted by the Engineer- in- charge. Each 2 108.000 216.000
26.61.1
0.000

450 mm long plastic flexible lead (connection) pipe 0.000

21 Sanitary works 26.62 & "Supplying, fitting, fixing of foreign made best quality Reverse Osmosis Water Purifier (Kent/Unilever/Vapor water Each 1 18577.000
26.62.1 purifier or equivalent brand) for purification of water by reverse osmosis system to have potable water conforming 18,577.0
WHO standard and Bangladesh concentration parameters including installation charge, carriage, sundries etc.
" 0.000
complete approved and accepted by the Engineer-in- charge.

0.000

Water purification capacity: 10 L/hr, storage 6 litre; RO+MF 0.000

22 Sanitary works 26.68 Punching or cutting hole of any diameter in RCC floor for sanitary works. Each 6 1110.000
185.000
23 Sanitary works 26.74 & Construction of septic tank of different sizes with walls of brick work in cement mortar (1:6) having a lining of each 1 136453.000
26.74.3 minimum 125 mm R.C.C cast against the walls as per approved type plan over a brick flat soling and 150 mm thick 136,453.0
reinforced cement concrete flooring (1:2:4) with 125 mm thick walls in partition and 12 mm thick cement plaster
0.000
(1:4) with N.C.F. to insides of walls on floor and all around outside walls by 450 mm height at top including

For 50 users 0.000


24 Sanitary works 26.76 & "Construction of soak well of different sizes (as per detail drawing attached in annexure) (medium and large sizes) each 1 104808.000
26.76.3 with 250 mm thick solid brick work and 250 mm honey comb brick work with cement mortar (1:6) as per design 104,808.0
over R.C.C. (1:2:4) well curb with 1% reinforcement up to the depth as per drawing with 450 mm dia water sealed
" 0.000
heavy type. C.I. manhole cover with locking arrangement, filling the well up to the required depth with graded khoa

0.000

50 users 0.000

25 Sanitary works 26.70 & Construction of masonry inspection pit with 250 mm thick brick work in cement mortar (1:4) including necessary each 20 77340.000
26.70.1 earth work, side filling and one layer brick flat soling, 75 mm thick (1:3:6) base concrete for making invert channel 3867.00
and 12 mm thick (1:2) cement plaster with neat finishing etc. all complete up to a depth of 700 mm approved and
0.000
accepted by the Engineer- in- charge.

"Clear 450 mm x 450 mm and depth 450 mm to 600 mm, average 525 mm for single 150 mm dia R.C.C pipes and 0.000
400 mm PVC pipe.
" 0.000

26 Sanitary works 26.70.4 Master-pit of Size: Clear 600 mm x 500 mm and average 750 mm depth for Septic tank. each 1 3796.000
3796.00
27 Sanitary works 26.72 & Construction and placing of R.C.C inspection pit cover (slab) with supplying and provisions for placing, fitting, each 21 43176.000
26.72.1 fixing 450 mm dia C.I. man-hole cover with locking/un-locking arrangement including concrete (1:2:4) with approx. 2056.00
1% re-enforcement, necessary earth cutting, or cleaning, side filling, curing etc. with minimum 12 mm cement
0.000
plaster (1:4) and neat cement finishing on edges and top all complete and accepted by the Engineer- in- charge.

950 mm x 950 mm x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover. 0.000

28 Sanitary works 26.73 & Construction of masonry inspection pits up to a depth of 700 mm with 250 mm thick brick work in cement mortar Each 1 10373.000
26.73.3 (1:4) including 100 mm thick R.C.C. top slab (1:2:4) with 1% reinforcement, man-hole cover with locking 10373.00
arrangement including necessary earth work, side filling and one brick flat soling. 75 mm thick (1:3:6) base concrete
0.000
for making invert channel and 12 mm thick (1:2) cement plaster with neat finishing etc. all complete approved and

"Clear 600 mm x 600 mm and depth 750 mm to 900 mm, average 825 mm for single 300 mm dia R.C.C.pipes and 0.000
375 mm and 400 mm PVC pipe with pit cover and 450 mm dia C.I. man-hole cover.
" 0.000

29 Sanitary works 27.1 Mobilization of test boring or observation well: Transportation of materials, equipments, tools and plants and boring Per set 1 7853.000
rig to work site. Construction of derrick and dismantling the same. Cleaning the site after completion of the work 7853.00
accepted by the Engineer-in-charge.
30 Sanitary works 27.2 & 27.2.1 Boring by using 100 mm dia cutter and 40 mm dia heavy type G.I pipe (wall thickness 2.9 mm, outside diameter min meter 50 9800.000
47.8 mm, weight 3.517 kg/m, capable to withstand 50 kg/cm2 pressure) and other equipments capable of drilling up 196.00
to a depth of 500 meter by water jet system through all sorts of soil strata providing protection of caving by
0.000
supplying necessary casing pipe. Collection of soil samples at every 3 meter interval and at every change of soil

From 0.0 m to 50 m = 50 m 0.000

31 Sanitary works 27.2.2 Above 50 m to 100 m = 50 m meter 50 11300.000


226.00
32 Sanitary works 27.19 & Supplying the following tube well fixtures and pipes having density 1350 kg/m3, opacity 0.2% of visible light as per Each 1 233.000
27.19.1 ISO 7686, minimum required strength 25 MPa conforming to BDS-1:2013, 4.4.1, 4.4.2 at working site as per 233.00
standard practice and accepted by the Engineer-in-charge.
0.000

Best quality 75 mm dia uPVC cap 0.000

33 Sanitary works 27.19.2.1 75 mm dia water grade(Class D) uPVC blind pipe/sand trap of wall thickness 4.6 mm to 5.3 mm meter 88 45584.000
518.00
34 Sanitary works 27.19.3.1 75 mm dia strainer of any slot as per design made with water grade (Class D) uPVC pipe of wall thickness 4.6 mm to meter 12 7092.000
5.3 mm 591.00
Total Tk. 771526.210

5 Item Group Item Code Description of Item


HATIL/ Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
Equivalent
1 Sofa Ocean-
HATIL/
Furniture 3 seater solid wooden sofa . all complete and approved the Engineer in-charge. Each 3.000 75,075.00 225,225.00
117
Equivalent
HATIL/
2 HCL-201-
HATIL/
Sofa Ocean-
HATIL/
Furniture Equivalent Center Tablesolid wooden sofa.all complete and approved the Engineer in-charge
Single seater no's 3.000 45,475.00 136,425.00
117-10-3-88
Equivalent
117
Equivalent
Corner Dove-143
3 Center
HCL-201-
Dining
Table Dimensions ( W xcombination
Hx D )
HATIL/ Unit Price:woden
8,700 BDT
Furniture Table
117-10-3-89
Harper-191
Gabriella- Dove- Glass and974x628x268 corner/side table.all complete and approved the Engineer in-charge. no's 4.000 10,900.00 43,600.00
Equivalent Approx.
Color: Antique; mm (With stand)
143
&
110 (Table
Truffle- Approx.
4 Dining
HATIL/ Qty: 1 974x572x68 mm (Without stand)
Furniture with(6
191
HIF-239- glass)
Chair Display TypeXFrame no's 2.000 12,400.00 24,800.00
Harper-191
Equivalent Size: L1060
Dining Table W560 X H480 mm
HCL-203-
+ 1Truffle-
Table + Glass-204-143
110-10-1-88 LCD
5 &
Dining Truffle-191
Furniture 143-10-1-
1 Wooden Each 2.000 18,450.00 36,900.00
191 (6 Chair Dolby
Harper-191 DigitalNoPlus
Glass Type: Color;
88, HCL- Color:
Top) DiningAntique;
Dolby™
Chair
Audio(Dolby™ Digital, Dolby™ Digital and
Plus,approved
Dolby™ AC-4)
+ 1Truffle-
& Table + Size:
Qty: 1L1600 X W1000 X H760 mm. all complete the Engineer in-charge.
6 Glass-204- Harper-191
Furniture 1HCL-237-
191 (6 Chair HDR
Wooden (High Dynamic
Size: L1060 X W560 X Range)
H8 mm all complete and approved the Engineer in-charge. Each 10.000 9,050.00 90,500.00
143
107, HCL- Color: Antique;
+ 1 Table + Yes(HDR10,
Top)
HATIL/ Solid HLG)
Top-237-107
Size: L480 X W580 X H855 mm. all complete and approved the Engineer in-charge.
7 214-191-10-
Sony/
Furniture Wooden On/off
1HCL-237-
Equivalent timer
Color: Antique; Each 2.000 16,550.00 33,100.00
1-88, HCL-
Equivalent
107, HCL- Conference
Yes Table
Office
Top) Size: L1620 X W1020 X H50. all complete and approved the Engineer in-charge.
8 43" smart Creepy-111-Top
215-191-10-
214-191-10-
Creepy-111
HCL-237- Operating System
Furniture Color: Each 1.000 53,900.00 53,900.000
1-88
TV
1-88,
(Top-
107, | HCL-
KDL-
HCL- Linux American
MATERIAL AND Teak
WOODand White;
FINISH
HATIL/ Qty: 1 Base
9 43W660G
215-191-10-
ATW+Leg)
214-191-10- Nylon
Resolution
Furniture Equivalent Size: L3600 X W1200 X H750 mm Each 1.000 35,300.00 35,300.000
1-88
HATIL/
Set
1-88,
Swivel
HATIL/ HCL- S.S Chrome base
1920x1080
Equivalent Creepy-111-Leg
MATERIAL
Screen Size AND
PRODUCTS INCLUDEWOOD IN FINISH
THIS (COLOR)
SET
10 HPL-505-
215-191-10-
Chair
Equivalent MATERIAL
Color: Light ANDStructure;
Gery WOOD FINISH
Furniture Executive Black
111-1-1T-
1-88
Jackson-106
43"
Executive
MATERIAL Table
AND Top
WOOD FINISH
Each 6.000 16,000.00 96,000.000
Meeting
HATIL/ Lacquer
Qty:
SIZE
Sleep 1 Finish
timer
Table
ATW, HPL-
HPL-507- Size: Byron-301-Top
Nylon Base XAND
11 Table
Equivalent MATERIAL
L680
Yes L3600
XEbony;
W670 X W1200 WOOD
SH480-570 FINISH
X H750 X mm.
BH730 (COLOR)
all complete and approved the Engineer in-charge.
mm
Furniture Auden-136-
505-111-3- Color: Each 1.000 22,850.00 22,850.000
Kennedy- S.S
106-NB-1-
Swivel
Chrome
Antique
PARTS
Sound and base
Natural
COLOR
Output AND/OR
(RMS) FABRIC
MFC(1-6)
1L-WT
44 Qty: 1
MATERIAL AND WOOD FINISH (COLOR)
12 101
Chair SIZE
Body:
5W Artificial
+L1200
5W leather-PU-3. all complete and approved the Engineer in-charge.
Furniture (Leg- Size:
Black X W600 X H32 mm Each 55.000 9,450.00 519,750.000
HPL-650-
Lyndon-127 750mm
Speaker X 525mm X 1230mm. all complete and approved the Engineer in-charge.
Type
GT+Top- Executive
SIZE Table Panel
13 101-10-1-87
HPL-507- Open Baffle Speaker
EB+Panel- Byron-301-Panel
L590 X W620 X SH440-530 X BH510 mm
Furniture 127-NB-1- Voice Each 27.000 10,550.00 284,850.000
GT = PARTSSearch-No.
Color: Grey Texture;
COLOR AND/OR FABRIC all complete and approved the Engineer in-charge.
44
Complete Qty: 1 Total Tk. 1603200.00
Seat:Fabric_OF-12, Back:Fabric_ OF-02. all complete and approved the Engineer in-charge.
Table) Size: L1200 X W488X H16 mm
6 Item Group HPL-501-
Item Code Executive
DescriptionTable
of ItemLeg Measureme Quantity Unit Price Total Price
no. 301-1-1-00,
(if any) Auden-136-Leg nt Unit
HPL-501- Color: Grey Texture;
1 Main Gate 2.1 & 02.1.2 Earth work in excavation in all kinds of soil for foundation trenches including layout, providing center lines, local CuM 15.3 2340.900
301-1-1-00, Qty: 1 153.00
bench-mark pillars, levelling, ramming and preparing the base, fixing bamboo spikes and marking layout with chalk
HPL-501- Size: L576
powder, X W75necessary
providing X H708 tools
mm. and
all complete and approved
plants, protecting the Engineer
and maintaining the trenchin-charge.
dry etc., stacking, cleaning the
136-3-2L-00 0.000
excavated earth at a safe distance out of the area enclosed by the layout etc. all complete and accepted by the

Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m lead 0.000

2 Main Gate 02.1.1 Layout and marking for earthwork in excavation in foundation accepted by the Engineer-in-charge. [Plinth area of SqM 11.61 208.980
the structure shall be considered for measurement] 18.00
3 Main Gate 3.4 & 3.4.1 Lean / blinding concrete (1:3:6) in foundation or in floor with cement, sand (F.M. 1.2) and picked jhama brick chips CuM 2.12 16222.240
including breaking of chips, screening, mixing, laying, compacting to required level and curing for at least 7 days 7,652.00
including the supply of water, electricity, costs of tools & plants and other charges etc. all complete and accepted by
0.000
the Engineer-in-charge.(Cement: CEM-II/B-M)

Blinding concrete in foundation (1:3:6) with cement, brick chips and sand of F.M. 1.2 0.000

4 Main Gate 2.13 Earth filling in foundation trenches and plinth in 150 mm layer with earth available within 90 m of the building site CuM 14.12 2668.680
to achive minimum dry density of 95% with optimum moisture content (Modified proctor test) including carrying 189.00
watering, leveling, dressing and compacting to a specified percentage each layer up to finished level etc. all complete
5 Main Gate 7.1 & 07.1.1 Reinforced cement concrete works with minimum cement content relates to mix ratio 1:2:4 having maximum water CuM 3 8521.00 25563.000
and accepted by Engineer-in-charge.
cement ratio = 0.45 and minimum f'cr = 26 MPa, satisfying a specified compressive strength f'c= 19 MPa at 28 days
on standard cylinders as per standard practice of Code ACI/BNBC/ASTM, cement conforming to BDS EN-197-1-
CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type ? I, best quality sand [50% quantity of best local sand (F.M. 1.2)
0.000

0.000

Individual & combined footing, pile cap, raft/mat, floor slab and foundation beam up to plinth level 0.000

6 Main Gate 07.1.2 Pedestal, column, column capital, lift wall and wall up to ground floor CuM 2.83 8853.00 25053.990

7 Main Gate 07.1.3 " Floor / Roof slab, T-beam, L-beam and rectangular beam, tie beam, lintel, stair case slab and step etc. up to ground CuM 2.04 17654.160
floor. 8654.00
" 0.000

8 Main Gate 7.18 & FORMWORK (Wooden) for boundary wall, gate, centry post etc .Centering and shuttering, including strutting, SqM 6.6 3313.200
07.18.1 propping etc. and removal of form for: 502.00
0.000

Individual and combined footing. 0.000

9 Main Gate 07.18.2 Founation Beam SqM 6.97 3192.260


458.00
10 Main Gate 07.18.3 Pedestals, column, wall SqM 23.8 12090.400
508.00
11 Main Gate 07.18.5 T-beam, L-beam and rectangular beam SqM 8.93 4375.700
490.00
12 Main Gate 07.18.6 Floor & roof slab SqM 11.24 6204.480
552.00
13 Main Gate 08.1.3 "Grade 500 (B500DWR: complying BDS ISO 6935-2:2016 / ASTM A615) ribbed or deformed bar produced and Kg 928 87232.000
marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 500 MPa and whatever is the 94.00
yield strength within allowable limit as per BNBC/ ACI 318, the ratio of ultimate tensile strength fu to actual yield
" 0.000
strength fy, shall be at least 1.25 and minimum elongation after fracture and minimum total elongation at maximum

14 Main Gate 15.12 Minimum 10 mm thick fair face plaster using premix cement plaster (CP2 LGT/Stucco base premix or equivalent); SqM 52 103532.000
initial background should be 19 mm rough cement plaster (1:4); then after passing 7 days curing time surface of 1991.00
newly constructed rough plaster should be throughly cleaned using a stiff brush to remove any dust, loose particles,
15 Main Gate 15.13.1 Making groove in fair face plaster on outside wall upto 50 mm X 6 mm size including scaffolding, curing etc. meter 23.16 1227.480
wood pieces, mould oil etc, then the backgound needs to be throughly neutralized by applying potable water; Mixing 53.00
complete as per drawing and accepted by the Engineer-in-charge.
16 Main Gate 15.14 "Minimum 1mm thick fair face coating using Master Emaco N 303 Rendroc FC/Top Crete 220 or equivalent product SqM 52 77792.000
micro toping skim coat, a high performance single component polymer fortified, colored, cementitious micro topping 1496.00
that can be applied on a variety of horizontal and vertical plaster surfaces; initially background should be thoroughly
" 0.000
cleaned using a stiff brush to remove any dust, loose particles, mould oil etc.; then the background needs to be

17 Main Gate 19.9 & 19.9.2 Manufacturing, supplying, fitting and fixing SS Swing front gate of any design and shape made of 50 mm x 50mm x SqM 11.15 160303.550
1.5 mm S.S. box section as outer frame, 37mm x 37mm x 1.5 mm SS box section as vertical section @ 100 mm c/c 14377.00
fitted with outer frame, 25 mm x 25 mm x 1.5 mm SS box section as horizontal section , 37 mm x 1.5 mm SS round
18 Main Gate 1.2 & 1.2.1.1 SURFACE CONDUIT POINT WIRING (BYM) (WITHOUT SWITCH) Surface conduit wiring for following point Point 3 3837.000
section fitted with vertical outer section for SS lettering, 25 mm dia SS solid round pipe, placing required number of 1279.00
looping at the switch board with earth terminal with 1C-2x1.5sq.mm PVC insulated and seathed standard cable
(BYM) & 1C-2X1.5sqmm. PVC insulated ECC (BYA) (Green / Yellow bi- colour) including circuit wiring (from
0.000
SDB to switch board) with 1C-2x2.5sqmm. PVC insulated and Sheathed standard cable (BYM) and 1C-

Light/ Exhaust or wall bracket fan point 0.000

19 Main Gate 1.9 & 1.9.1.2 Channel wiring (BYA)Surface channe wiring with the following PVC insulated standard cable (BYA) & Green RM 20 3760.000
/Yellow by colour PVCinsulated ECC wire (BYA) through minimum 1mm thick PVC channel complete with fixing 188.00
materials, other accessories etc. as required including mending the damages good. all electrical contacts shall be of
0.000
brass / copper connected through connector or soldering (no twisting shall be allowed) and cables shall be

1C-2x2.5 sqmm (BYA) cable with 2.5 sqmm (BYA) ECC wire 0.000
20 Main Gate 4.12 GANG SWITCH:Providing & fixing 250 volts 5/6 amps (minimum) concealed type following switch / switch socket Each 5 2325.000
manufactured/assembled and tested in accordence with IEC/VDE/NEMA/BS/JIS along with relevant BDS/IEC 465.00
standards mounted on required size 18 SWG galvanized plain sheet / PVC board (self-extinguishing 650˚C) of 76.2
21 Main Gate 4.12.2.1 & Made in Hongkong/ Malyasia/ Singapore/ South Korea/ Thailand Each 1 375.000
mm (3'') depth. all electrical contacts shall be of bass / copper. 375.00
4.12.2.2
0.000

Two gang Switch 0.000

22 Main Gate 4.4 & 4.4.1.1 CIRCUIT BREAKER (SPMCB)Providing and fixing on a prepared board 250 volt grade following single pole Each 1 779.000
miniature circuit breaker (SPMCBS) having minimum breaking capacity 6-KA /10 KA with thermal over-current 779.00
and instaneous electromagnetic short circuit release provision as per BDS / IEC and IEC/VDE/ NEMA/ BS/JIS
23 Main Gate - Supply & fixing of the following energy savings lamp (CFL) having Illuminate even at low voltage as 110 volts. Each 3 990.000
standards. 5-40 Amps(minimum 6 KA) MCB 330.00
Built in short circuit & over voltage protection feature & 8000 hrs. (minimum) lifetime, 230V / 250V, 50HZ
manufacturers by OSRAM / PHILIPS /ENERGYPAC / CBE / CORONA / HAVELLS/ GE EDISION I EASTERN /
PRODIP / MEP / METRO / HARMONICS / SUPERSTAR / TRANSTEC / ENERGY+ or equivalent brand Total Tk. 561041.02

7 Item Group Item Code Description of Item Measureme Quantity


no. (if any) nt Unit
1 Road Pavement- 1.6 Providing layout and carry over PWD Bench-Mark (BM) at site from nearby BM pillar, Property lines, existing SqM 316.55 30.00 9496.500
Civil work ground level (EGL), formation ground level (FGL), highest flood levels (HFL), plinth levels (PL), mean sea level
(MSL), setting and marking all pillars, marker, pegs etc. showing and maintaining reduced levels (RL's) including
2 Road Pavement- 24.2 & 24.2.1 Earthwork in box cutting in all types of soil. Removing soil to a safe distance, maintaining proper alignment, camber SqM 280.15 16809.000
locating, establishing, protecting all public utilities within the premise of work and finally all to be presented in black 60.00
Civil work and grade including leveling, dressing and compacting the sub grade as per drawing and accepted by the Engineer-
in-charge.
0.000

Depth up to 300 mm 0.000

3 Road Pavement- 03.1.1 One layer brick flat soling in foundation or in floor with first class/picked jhama bricks (BDS 208) including SqM 237.25 118625.000
Civil work preparation of bed and filling the interstices with local sand, leveling etc. complete and accepted by the Engineer-in- 500.0
charge
4 Road Pavement- 3.4 & 3.4.1 Lean / blinding concrete (1:3:6) in foundation or in floor with cement, sand (F.M. 1.2) and picked jhama brick chips CuM 0.39 2984.280
Civil work including breaking of chips, screening, mixing, laying, compacting to required level and curing for at least 7 days 7,652.0
including the supply of water, electricity, costs of tools & plants and other charges etc. all complete and accepted by
0.000
the Engineer-in-charge.(Cement: CEM-II/B-M)

Lean / blinding concrete in foundation (1:3:6) with cement,brick chips and sand of F.M.1.2 0.000

5 Road Pavement- 02.10.1 Sand filling in foundation trenches and plinth with sand having minimum F.M. 0.5 in 150 mm layers including CuM 82.55 88245.950
Civil work leveling, watering and compaction to achieve minimum dry density of 95% with optimum moisture content 1,069.0
(Modified proctor test) by ramming each layer up to finished level as per design supplied by the design office only,
6 Road Pavement- 3.7 Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor or any SqM 289.9 13335.400
all complete and accepted by the Engineer-in-charge. 46.0
Civil work where below cement concrete complete in all respect and accepted by Engineer-in-charge.
7 Road Pavement- 4.1 Brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:6) in foundation and plinth, filling the CuM 7.8 56752.800
Civil work joints/interstices fully with mortar, racking out the joints, cleaning and soaking the bricks at least for 24 hours before 7,276.0
use and curing at least for 7 days etc. all complete including cost of water, electricity and other charges and accepted
8 Road Pavement- 7.2 & 07.2.3 Reinforced cement concrete works with minimum cement content relates to mix ratio 1:2:4 having maximum water CuM 35.75 459637.750
by the Engineer-in-charge. (Cement: CEM-II/B-M) 12,857.0
Civil work cement ratio = 0.40 and minimum f'cr = 30.5 MPa, satisfying a specified compressive strength f'c = 22 MPa at 28
days on standard cylinders as per standard practice of Code ACI/BNBC/ASTM, cement conforming to BDS EN-
0.000
197-1-CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type ? I, best quality Sylhet sand or coarse sand of equivalent F.M.

"Floor / Roof slab, T-beam, L-beam and rectangular beam, Tie beam, lintel, stair case slab and steps etc. up to 0.000
ground floor.
" 0.000

9 Road Pavement- 8.1.3 "Grade 500 (B500DWR: complying BDS ISO 6935-2:2016 / ASTM A615) ribbed or deformed bar produced and Kg 2015 189410.000
Civil work marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 500 MPa and whatever is the 94.0
yield strength within allowable limit as per BNBC/ ACI 318, the ratio of ultimate tensile strength fu to actual yield
" 0.000
strength fy, shall be at least 1.25 and minimum elongation after fracture and minimum total elongation at maximum

10 Road Pavement- - Expansion Sheet( Foam-25mm thickness) @6.09m c/c. as per BDS standard. RM 34.45 5167.500
Civil work 150.00
Total Tk. 960464.180

8 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Surface Drain 1.6 Providing layout and carry over PWD bench-mark (BM) at site from nearby BM pillar, property lines, existing SqM 96.2 2886.000
ground level (EGL), formation ground level (FGL), highest flood levels (HFL), plinth levels (PL), mean sea level 30.00
(MSL), setting and marking all pillars, marker, pegs etc. showing and maintaining reduced levels (RL's) including
2 Surface Drain 02.1 & 02.1.1 Earth work in excavation in all kinds of soil for foundation trenches including layout, providing center lines, local SqM 72.15 1298.700
locating, establishing, protecting all public utilities within the premise of work and finally all to be presented in black 18.00
bench-mark pillars, levelling, ramming and preparing the base, fixing bamboo spikes and marking layout with chalk
powder, providing necessary tools and plants, protecting and maintaining the trench dry etc., stacking, cleaning the
excavated earth at a safe distance out of the area enclosed by the layout etc. all complete and accepted by the

Layout and marking for earthwork in excavation in foundation accepted by the Engineer-in-charge. [Plinth area of
the structure shall be considered for measurement]
3 Surface Drain 02.1.2 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m lead CuM 60.45 9248.850
153.00
4 Surface Drain 02.10.1 Sand filling in foundation trenches and plinth with sand having minimum F.M. 0.5 in 150 mm layers including CuM 16.25 17371.250
leveling, watering and compaction to achieve minimum dry density of 95% with optimum moisture content 1069.00
(Modified proctor test) by ramming each layer up to finished level as per design supplied by the design office only,
5 Surface Drain 03.1.1 One layer Brick flat soling in foundation or in floor with first class/picked jhama bricks (BDS 208) including SqM 72.15 36075.000
all complete and accepted by the Engineer-in-charge. 500.00
preparation of bed and filling the interstices with local sand, leveling etc. complete and accepted by the Engineer-in-
charge
6 Surface Drain 03.4.1 Lean/blinding concrete in foundation (1:3:6) with cement, brick chips and sand of F.M. 1.2 CuM 5.2 39790.400
7652.00
7 Surface Drain 3.7 Supplying and laying of Single layer polythene weighing one kilogram per 6.5 square meter in floor or any where SqM 72.15 3318.900
below cement concrete complete in all respect and accepted by Engineer-in-charge. 46.00
8 Surface Drain 4.1 Brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:6) in foundation and plinth, filling the CuM 19.5 141882.000
joints/interstices fully with mortar, racking out the joints, cleaning and soaking the bricks at least for 24 hours before 7276.00
use and curing at least for 7 days etc. all complete including cost of water, electricity and other charges and accepted
9 Surface Drain 15.2 Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing to plinth wall with cement (1:4) up SqM 151.45 51493.000
by the Engineer-in-charge. (Cement: CEM-II/B-M) 340.00
to 150 mm below ground level including washing of sand, finishing the edges and corners and curing at least for 7
days, cost of water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and
Total Tk. 303364.100
accepted by the Engineer-in-charge. (Cement: CEM-II/B-M) ground floor.

9 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Land 2.16 & 2.16.2 "Site development/Improvement by carted earth or dredged sand, sandy silt (free from any organic, foreign, CuM 536.35 270320.400
Development environmental hazardous substances) carried by head or by truck or by any other means including cost of cutting or 504.00
Works by dredging of sand, sandy silt including local carrying, placing the earth/sand, sandy silt in the designated area,
"
maintaining slopes, breaking lumps, levelling and dressing in layers up to finished level etc. all complete as per

By dredging including necessary systems thereof.

2 Land 2.17 "Mechanical compaction of earth beyond plinth area, required for pre-approved specific engineering purpose in 150 CuM 46 9568.000
Development mm layers including levelling, watering and consolidation each layer with chain dozer, grader, roller etc. to achieve 208.00
Works minimum dry density of 95% with optimum moisture content (modified proctor test) up to finished level all
submission of the method statement.
complete and accepted by the engineer-in-charge subjected to

"

3 Land 25.3 Leveling and dressing of lawn area to proper slope and grade by spading the same up to 150 mm including supplying SqM 896 7168.000
Development tools and plants etc. all complete and accepted by the Engineer-in-charge. 8.00
Works
Total Tk. 287056.400

10 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Boundary wall 02.1 & 02.1.2 Earth work in excavation in all kinds of soil for foundation trenches including layout, providing center lines, local CuM 41.56 6358.680
bench-mark pillars, levelling, ramming and preparing the base, fixing bamboo spikes and marking layout with chalk 153.00
powder, providing necessary tools and plants, protecting and maintaining the trench dry etc., stacking, cleaning the
excavated earth at a safe distance out of the area enclosed by the layout etc. all complete and accepted by the
Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m lead 0.000

2 Boundary wall 02.1.1 Layout and marking for earthwork in excavation in foundation accepted by the Engineer-in-charge. [Plinth area of SqM 42.48 764.640
the structure shall be considered for measurement] 18.00
3 Boundary wall 3.4 & 3.4.1 Lean / blinding concrete (1:3:6) in foundation or in floor with cement, sand (F.M. 1.2) and picked jhama brick chips CuM 1.86 14232.720
including breaking of chips, screening, mixing, laying, compacting to required level and curing for at least 7 days 7652.00
including the supply of water, electricity, costs of tools & plants and other charges etc. all complete and accepted by
0.000
the Engineer-in-charge.(Cement: CEM-II/B-M)

Blinding concrete in foundation (1:3:6) with cement, brick chips and sand of F.M. 1.2 0.000

4 Boundary wall 03.1.1 One layer brick flat soling in foundation or in floor with first class/picked jhama bricks (BDS 208) including SqM 51.67 25835.000
preparation of bed and filling the interstices with local sand, leveling etc. complete and accepted by the Engineer-in- 500.00
charge
5 Boundary wall 2.13 Earth filling in foundation trenches and plinth in 150 mm layer with earth available within 90 m of the building site CuM 31.23 5902.470
to achive minimum dry density of 95% with optimum moisture content (Modified proctor test) including carrying 189.00
watering, leveling, dressing and compacting to a specified percentage each layer up to finished level etc. all complete
6 Boundary wall 7.1 & 07.1.1 Reinforced cement concrete works with minimum cement content relates to mix ratio 1:2:4 having maximum water CuM 17.22 146731.620
and accepted by Engineer-in-charge. 8521.00
cement ratio = 0.45 and minimum f'cr = 26 MPa, satisfying a specified compressive strength f'c= 19 MPa at 28 days
on standard cylinders as per standard practice of Code ACI/BNBC/ASTM, cement conforming to BDS EN-197-1-
0.000
CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type ? I, best quality sand [50% quantity of best local sand (F.M. 1.2)

Individual & combined footing, pile cap, raft/mat, floor slab and foundation beam up to plinth level 0.000

7 Boundary wall 07.1.2 Pedestal, column, column capital, lift wall and wall up to ground floor CuM 5.96 8853.00 52763.880

8 Boundary wall 07.1.3 " Floor / Roof slab, T-beam, L-beam and rectangular beam, tie beam, lintel, stair case slab and step etc. up to ground CuM 1.14 9865.560
floor. 8654.00
" 0.000

9 Boundary wall 7.18 FORMWORK (Wooden) for boundary wall, gate, centry post etc .Centering and shuttering, including strutting, SqM 34 17068.000
propping etc. and removal of form for: 502.00
0.000

Individual and combined footing. 0.000

10 Boundary wall 07.18.2 Founation Beam SqM 53.27 24397.660


458.00
11 Boundary wall 07.18.3 Pedestals, column, wall SqM 95.54 48534.320
508.00
12 Boundary wall 07.18.5 T-beam, L-beam and rectangular beam SqM 45.92 22500.800
490.00
13 Boundary wall 08.1.3 "Grade 500 (B500DWR: complying BDS ISO 6935-2:2016 / ASTM A615) ribbed or deformed bar produced and Kg 1561.74 146803.560
marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 500 MPa and whatever is the 94.00
yield strength within allowable limit as per BNBC/ ACI 318, the ratio of ultimate tensile strength fu to actual yield
" 0.000
strength fy, shall be at least 1.25 and minimum elongation after fracture and minimum total elongation at maximum

14 Boundary wall 15.1.1 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to both inner-and outer surface of SqM 533.1 149801.100
wall, finishing the corner and edges including washing of sand, cleaning the surface, curing at least for 7 days, cost 281.00
of water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and accepted by the
15 Boundary wall 16.1.1 Exterior standard acrylic emulsion paint of approved best quality and color having water resisting properties and SqM 533.1 139139.100
Engineer-in-charge. (Cement: CEM-II/B-M) ground floor. 261.00
resistance properties against fungi, fading & flaking delivered from authorized local agent of the manufacturer in a
sealed container; applying to exterior surface with surface preparation including cleaning, drying, making free from
16 Boundary wall 1.2 & 1.2.1.1 SURFACE CONDUIT POINT WIRING (BYM) (WITHOUT SWITCH) Surface conduit wiring for following point Point 24 30696.000
dirt, grease, wax, removing all chalked and scaled materials, fungus, mending good the surface defects using sand 1279.00
looping at the switch board with earth terminal with 1C-2x1.5sq.mm PVC insulated and seathed standard cable
(BYM) & 1C-2X1.5sqmm. PVC insulated ECC (BYA) (Green / Yellow bi- colour) including circuit wiring (from
0.000
SDB to switch board) with 1C-2x2.5sqmm. PVC insulated and Sheathed standard cable (BYM) and 1C-

Light/ Exhaust or wall bracket fan point 0.000


17 Boundary wall 1.9 & 1.9.1.1 Channel wiring (BYA)Surface channe wiring with the following PVC insulated standard cable (BYA) & Green RM 70 9170.000
/Yellow by colour PVCinsulated ECC wire (BYA) through minimum 1mm thick PVC channel complete with fixing 131.00
materials, other accessories etc. as required including mending the damages good. all electrical contacts shall be of
0.000
brass / copper connected through connector or soldering (no twisting shall be allowed) and cables shall be

1C-2x1.5 sqmm (BYA) cable with 1.5 sqmm (BYA) ECC wire 0.000

18 Boundary wall 4.12 & 4.12.2 GANG SWITCH:Providing & fixing 250 volts 5/6 amps (minimum) concealed type following switch / switch socket Each 24 5232.000
& 4.12.2.1 manufactured/assembled and tested in accordence with IEC/VDE/NEMA/BS/JIS along with relevant BDS/IEC 218.00
standards mounted on required size 18 SWG galvanized plain sheet / PVC board (self-extinguishing 650˚C) of 76.2
0.000
mm (3'') depth. all electrical contacts shall be of bass / copper.

Made in Hongkong/ Malyasia/ Singapore/ South Korea/ Thailand 0.000

0.000

One gang Switch 0.000

19 Boundary wall - Supply & fixing of the following Energy savings lamp (CFL) having Illuminate even at low voltage as 110 volts. Each 72 23760.000
Built in short circuit & over voltage protection feature & 8000 hrs. (minimum) lifetime, 230V / 250V, 50HZ 330.00
manufacturers by OSRAM / PHILIPS /ENERGYPAC / CBE / CORONA / HAVELLS/ GE EDISION I EASTERN /
Total Tk. 879557.110
PRODIP / MEP / METRO / HARMONICS / SUPERSTAR / TRANSTEC / ENERGY+ or equivalent brand

10 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Name plate and - Name plate and logo, Materials SS (Stainless steel), Thickness 2mm-4mm, all complete and accepted by the LS 1 50000.000
Logo Engineer-in-charge. 50000.00
2 MS Collapsible 19.1.3 Manufacturing, supplying, fitting and fixing M.S. collapsible gate of any design and shape made of 25 mm x 25 mm SqM 12.36 72058.800
gate x 3 mm M.S. angle placed @ 112 mm c/c vertically and connecting the same with each other by 25 mm x 3 mm M.S 5830.00
flat bar scissors 525 mm, 600 mm long provided in 3 rows including cutting the different M.S. members to required
Total Tk. 122058.800
sizes, fabricating, welding, riveting with required size rivets, providing required size wheels, pulling handles on both

Gross Total Tk. 17,488,619.71

322,569.71

Original Estimate Tk. 17,166,050.00

(-) App Cost Tk. 15,500,000.00

SELECT