6 Civil work 02.1.1 Layout and marking for earthwork in excavation in foundation accepted by the Engineer-in-charge. [Plinth area of SqM 54.48 980.640
the structure shall be considered for measurement] 18.0
7 Civil work 2.17 "Mechanical compaction of earth beyond plinth area, required for pre-approved specific engineering purpose in 150 CuM 33.04 6,872.320
mm layers including levelling, watering and consolidation each layer with chain dozer, grader, roller etc. to achieve 208.0
minimum dry density of 95% with optimum moisture content (modified proctor test) up to finished level all
8 Civil work 03.1.1 One layer brick flat soling in foundation or in floor with first class/picked jhama bricks (BDS 208) including SqM 312.08 156,040.000
complete and accepted by the engineer-in-charge subjected to submission of the method statement. 500.0
preparation of bed and filling the interstices with local sand, leveling etc. complete and accepted by the Engineer-in-
charge
9 Civil work 3.4 & 3.4.1 Lean / blinding concrete (1:3:6) in foundation or in floor with cement, sand (F.M. 1.2) and picked jhama brick chips CuM 1.03 7,881.560
including breaking of chips, screening, mixing, laying, compacting to required level and curing for at least 7 days 7,652.0
including the supply of water, electricity, costs of tools & plants and other charges etc. all complete and accepted by
Lean / blinding concrete in foundation(1:3:6)with cement, brick chips and sand of F.M. 1.2 -
the Engineer-in-charge.(Cement: CEM-II/B-M)
10 Civil work 2.13 Earth filling in foundation trenches and plinth in 150 mm layer with earth available within 90 m of the building site CuM 90.93 17,185.770
to achive minimum dry density of 95% with optimum moisture content (Modified proctor test) including carrying 189.0
watering, leveling, dressing and compacting to a specified percentage each layer up to finished level etc. all complete
11 Civil work 02.10.1 Sand filling in foundation trenches and plinth with sand having minimum F.M. 0.5 in 150 mm layers including CuM 132 141,108.000
and accepted by Engineer-in-charge. 1,069.0
leveling, watering and compaction to achieve minimum dry density of 95% with optimum moisture content
(Modified proctor test) by ramming each layer up to finished level as per design supplied by the design office only,
12 Civil work 3.6 & 03.6.1 Damp proof course (DPC) (1:1.5:3) of cement concrete with cement, sand and picked jhama brick chips or stone SqM 126 184,716.000
all complete and accepted by the Engineer-in-charge. 1,466.0
chips including breaking of chips, screening, centering, shuttering, casting, curing and finishing with a coat of
bitumen including the supply of water, electricity, costs of tools & plants and other charges etc. all complete and
75mm thick damp proof course(1:1.5:3)with cement, Sylhet sand (F.M-2.2) and stone chips. -
accepted by Engineer-in-charge. (Cement: CEM-II/B-M)
13 Civil work 3.7 Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor or any SqM 216 9,936.000
where below cement concrete complete in all respect and accepted by Engineer-in-charge. 46.0
14 Civil work 4.1 Brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:6) in foundation and plinth, filling the CuM 8.9 64,756.400
joints/interstices fully with mortar, racking out the joints, cleaning and soaking the bricks at least for 24 hours before 7,276.0
use and curing at least for 7 days etc. all complete including cost of water, electricity and other charges and accepted
15 Civil work 4.16 "125 mm brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:4) and making bond with SqM 243.49 278,065.580
by the Engineer-in-charge. (Cement: CEM-II/B-M) 1,142.0
connected walls including necessary scaffolding, raking out joints, cleaning and soaking the bricks for at least 24
hours before use and washing of sand, curing at least for 7 days in all floors including cost of water, electricity and
" -
other charges etc. all complete and accepted by the Engineer-in-charge. (Cement: CEM-II/B-M) In ground floor
16 Civil work 4.16 "125 mm brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:4) and making bond with SqM 82.24 96,056.320
connected walls including necessary scaffolding, raking out joints, cleaning and soaking the bricks for at least 24 1,168.0
hours before use and washing of sand, curing at least for 7 days in all floors including cost of water, electricity and
" -
other charges etc. all complete and accepted by the Engineer-in-charge. (Cement: CEM-II/B-M)1st floor
17 Civil work 6.6 & 6.6.3 "Supplying, fitting and fixing country made glazed wall tiles complying BDS ISO 13006: 2015, irrespective of color SqM 61.43 110,635.430
&/or design, with 20 mm thick cement sand (F.M. 1.2) mortar (1:3) base and raking out the joints with white cement 1,801.0
including cutting, laying and hire charge of machine and finishing with care etc. including cost of water, electricity
" -
and other charges complete in all respect and accep. by the Engineer-in-charge.(Cement: CEM-II/A-M).
Wall tiles more than 250 mm x 400 mm & less than or equal to 300 mm x 600 mm in sizes -
18 Civil work 6.2 & 06.2.2 Supplying, fitting and fixing country made mirror polished homogeneous floor tiles complying BDS ISO 13006: Sqm 180.76 314,341.640
2015, water absorption ≤ 0.5%, modulus of rupture (MOR) ≥ 27 N/mm2, irrespective of color &/or design, with 20 1,739.0
mm thick cement sand (F.M. 1.2) mortar (1:4) base and raking out the joints with white cement including cutting and
-
laying the tiles in proper way and finishing with care etc. all complete and accepted by the Engineer-in-charge.
19 Civil work 6.3 & 06.3.1 "Supplying, fitting and fixing country made homogeneous matt finished/ rustic floor tiles complying BDS ISO SqM 13.38 22,344.600
13006: 2015, water absorption ≤ 0.5%, modulus of rupture (MOR) ≥ 27 N/mm2, irrespective of color &/or design, 1,670.0
with 20 mm thick cement sand (F.M. 1.2) mortar (1:4) base and raking out the joints with white cement including
" -
cutting and laying the tiles in proper way and finishing with care etc. all complete and accepted by the Engineer-in-
20 Civil work 6.1 & 6.10.1 Supplying, fitting and fixing country made GP homogeneous stair tiles having non skidding offsets, complying BDS SqM 4 5,624.000
ISO 13006: 2015, water absorption ≤ 0.5%, modulus of rupture (MOR) ≥ 27 N/mm2, irrespective of color &/or 1,406.0
design, with 20 mm thick cement sand (F.M. 1.2) mortar (1:4) base and raking out the joints with white cement
-
including cutting and laying the tiles in proper way and finishing with care
Glazed stair tiles having size of width 250 mm to 300 mm and length 300 mm -
21 Civil work 6.15 & 6.15.1 Supplying, fitting and fixing 20mm to 25mm thick machine made cement pavement tiles having minimum SqM 217.93 251,927.080
compressive strength of 27 MPa, irrespective of color &/or design, with 20 mm thick cement sand (F.M. 1.2) mortar 1,156.0
(1:4) base and making the joints carefully in true straight line including cutting, laying and hire charge of machine
-
and finishing with care etc. including water, electricity and other charges complete in all respect and accepted by the
22 Civil work 7.2 & 07.2.1 Reinforced cement concrete works with minimum cement content relates to mix ratio 1:2:4 having maximum water CuM 75.71 963,334.040
cement ratio.40 and minimum f'cr = 30.5 MPa, satisfying a specified compressive strength f'c = 22 MPa at 28 days 12,724.0
on standard cylinders as per standard practice of Code ACI/BNBC/ASTM, cement conforming to BDS EN-197-1-
-
CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type ? I, best quality Sylhet sand or coarse sand of equivalent F.M. 2.2
Individual & combined footing, pile cap, raft/mat, floor slab and foundation beam up to plinth level -
23 Civil work 07.2.2 Pedestals, column, column capital, lift wall and RCC wall up to ground floor CuM 21.29 277,962.240
13,056.0
24 Civil work 07.2.3 "Floor / Roof slab, T-beam, L-beam and rectangular beam, Tie beam, lintel, stair case slab and steps etc. up to CuM 48.59 624,721.630
ground floor 12,857.0
" -
25 Civil work 07.2.4 "Cornice, railing, drop wall, louver, fins, sunshade, false ceiling, waffle and ribbed floor slab etc. up to ground floor CuM 1.02 13,655.760
13,388.0
" -
26 Civil work 7.12 & 7.12.1 "Centering and shuttering, including strutting, propping etc. (The formwork must be rigid enough both in and out of SqM 55.48 31,512.640
plane, to make the concrete surface true to the designed shape and size by using necessary MS sheets of minimum 16 568.0
BWG, angles of minimum size 40 mm x 40 mm x 5 mm, flat bars etc.) and removal of form for
" -
35 Civil work 11.1 & 11.1.5 Supplying and making door and window frames (Chowkat) for all floors in/c wall side grove cutting, moulding by CuM 0.40 105,734.000
& 11.1.5.1 CNC machine or any other means with matured seasoned wood of required size including painting two coats of coal 264,335.0
tar to the surface in contact with wall, fitting and fixing in position etc. all complete and accepted by the Engineer-in-
-
charge. (All sizes of wood are finished).
Frame made from seasoned Jessore & Other Local Teak (10,573.40) -
36 Civil work 11.2.2 Supplying, fitting and fixing M.S. flat bar clamp of 150 mm x 38 mm x 6 mm size having bifurcated ends to door Each 56 7,056.000
and window frames with necessary rowel plug, screws etc. including cutting grooves in chowkat if necessary etc. all 126.0
complete and accepted by the Engineer-in-charge.
37 Civil work 11.3.1 Supplying, fitting and fixing double leaf door frame for all floors made with 38mm x 38 mm x 6 mm M.S. angle meter 17.3 12,456.000
fitted with 150 mm long 6 nos. iron clamps of same size M.S. angle (with one end bifurcated) with the vertical 720.0
members of the frame, fixing the frame in wall with cement concrete (1:2:4), mending good the damages, fixing 6
38 Civil work 11.3.2 Supplying, fitting and fixing double leaf door frame for all floors made with 38mm x 38 mm x 6 mm M.S. angle meter 25.39 17,671.440
Nos. of 100 mm long iron hinges with the vertical members of the frame all complete including making holes in 696.0
fitted with 150 mm long 6 nos. iron clamps of same size M.S. angle (with one end bifurcated) with the vertical
members of the frame, fixing the frame in wall with cement concrete (1:2:4), mending good the damages, fixing 6
39 Civil work 12.1 & "Supplying, fitting and fixing of 38 mm thick well matured seasoned (moisture content should be between 12% to Sqm 8.46 116,113.500
Nos. of 100 mm long iron hinges with the vertical members of the frame all complete including making holes in 13,725.0
12.1.3.1 16%) solid wood single leaf door shutter having stile section 100m x 38mm, top rail section 125mm x 38mm, lock
rail section 100mm x 38mm and bottom rail section 225mm x 38mm (made from minimum 250mm wide plank)
" -
with 4nos 100mm long, 3mm thick hinge, 12mm dia 250mm long tower bolt, 12mm dia 200mm long socket bolt,
40 Civil work 12.3 & "Supplying, fitting and fixing 38mm thick well matured seasoned (moisture content should be between 12 to 16%) Sqm 9.52 144,037.600
12.3.3.1 wooden double leaf panel door shutters having stile and top rail section 100mm x 38mm, lock rail section 125mm x 15,130.0
38mm and bottom rail section 225mm x 38mm, panelling 38mm thick both sides raised (made from minimum
" -
250mm wide plank) with 4nos 100mm long, 3mm thick hinge, 12mm dia 250mm long tower bolt, 12mm dia 200mm
41 Civil work 12.19 & Supplying, fitting and fixing of well matured wooden louver shutter (Chattogram Teak) having 75.50 mm x 38 mm Sqm 0.83 13,982.180
12.19.1 size all around frame and inner horizontal wooden louver blade 65 mm x 20 mm spaced @ 38 mm c/c, fitted and 16,846.0
fixed with 2 nos hinges, 1 no handle and 2 nos magnetic catch. All complete in all floors and accepted by the
-
Engineer-in-charge.
With SS Fittings -
42 Civil work 12.21 & "Supplying, fitting and fixing mortice door lock with lever handle of approved quality including all necessary tools Each 3 3,636.000
12.21.1 and accessories etc. all complete approved and accepted by the Engineer-in-charge. 1,212.0
" -
Standard Quality -
43 Civil work 12.22 & "Supplying, fitting and fixing rim/round door lock of approved quality including all necessary tools and accessories Each 5 5,140.000
12.22.1 etc. all complete and accepted by the Engineer-in-charge. 1,028.0
" -
Standard Quality -
44 Civil work 12.23 & "Supplying, fitting and fixing best quality heavy type 19 mm dia and 300 mm long hasp bolt including cutting Each 3 1,638.000
12.23.2 grooves in door shutter and frames, screws etc. all complete approved and accepted by the Engineer-in-charge. 546.0
-
" -
SS Hasp Bolt -
45 Civil work 12.25 Supplying, fitting and fixing approved best quality foreign made stainless steel/brass door viewer/eye viewer from Each 1 589.000
12 mm to 20 mm diameter with adjustable thickness suitable for fitting from 37 mm to 50 mm thick door shutter in/c 589.0
all necessary work as per direction and accepted by the Engineer-in-charge.
46 Civil work 13.5.2 "Supplying, fitting and fixing window grill made of 12 mm x 12 mm M.S. solid bar @ 100mm c/c with outer frame SqM 28.15 78,594.800
of 38 mm x 6mm F.I. bar and 25 mm x 6 mm F.I. bar for clamp as per design including fabrication, welding, cost of 2,792.0
electricity workshop charges, labour charges for fitting and fixing grills in position, local carriage charges, cutting
" -
grooves, mending good the damages, tools and plants, finished with anti-corrosive painting (Red-Oxide) etc.
47 Civil work 13.9 Supplying, fitting and fixing MS verandah grill as per design and shape with 75 mm x 50 mm MS box with 3mm SqM 0.9 4,146.300
wall thickness middle rail (horizontal), 50 mm x 25 mm vertical rail with 3mm wall thickness @ approx. 750 mm c/c 4,607.0
, 25x25 mm MS box with 2 mm wall thickness horizontally @100mm c/c as per required measurement including
48 Civil work 14.4 & 14.4.2 "Supplying, fitting and fixing of aluminium sliding doors as per the U.S. Architectural Aluminium Manufacturer's Sqm 3.25 12,174.500
cutting grooves in wall up to 150 mm depth and mending good the damages with C.C. (1:1.5:3), finished with anti- 3,746.0
Association (AAMA) standard specification and BDS 1879:2014 having minimum 1.2 mm thick outer bottom (size
75.50 mm, 17.79 mm, 0.47 kg/m), minimum 1.2 mm thick outer top (size 75.50 mm, 28.50 mm, 0.705
" -
kg/m) ,minimum 1.2 mm thick shutter top (size 33 mm, 26.80 mm, 0.42 kg/m), minimum 1.2 mm shutter bottom
49 Civil work 14.9 & 14.9.1 "Supplying, fitting and fixing of equal diamension frame(EDF) section aluminium sliding window with mosquito SqM 25.09 160,626.180
& 14.9.1.1 mesh as per the U.S. Architectural Aluminium Manufacturer's Association (AAMA) standard specification and BDS 6,402.0
1879:2014 having 1.5 mm thick outer bottom (size 91.50 mm, 38.00 mm), 1.5 mm thick outer top (size 91.00 mm,
" -
28.70 mm), 1.5 mm thick shutter top (size 65.00 mm, 27.30 mm), 1.5 mm thick shutter bottom (size 72.20 mm,
50 Civil work 14.11 & "Supplying, fitting and fixing of aluminium top hung/casement windows as per the U.S. Architectural Aluminium Sqm 2.09 23,322.310
14.11.1 Manufacturer's Association (AAMA) standard specification and BDS 1879:2014 having 1.5 mm thick casement 11,159.0
outer (size 38.86 mm, 36.36 mm, 0.395kg/m), 1.9 mm thick casement shutter (size 47.62 mm, 28.57 mm, 0.692
kg/m), and 1.245 mm thick shutter glass clip (size 15.87 mm, 27 mm, 0.188 kg/m) sections of all aluminium
" -
51 Civil work 14.16 & Supplying, fitting and fixing in Aluminium door frames, windows, partitions and curtain wall distortion free glass of SqM 30.48 44,897.040
14.16.1.1.1 approved quality and shade including cost of fitting fixing all necessary accessories etc. complete in all respect as per 1,473.0
drawing and accepted by the Engineer-in-charge.
-
52 Civil work 14.16.4.2 10mm thick clear tempered glass SqM 1.38 5,851.200
4,240.0
53 Civil work 15.1.1 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to both inner-and outer surface of SqM 260 73,060.000
wall, finishing the corner and edges including washing of sand, cleaning the surface, curing at least for 7 days, cost 281.0
of water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and accepted by the
54 Civil work 15.1.2 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to both inner-and outer surface of SqM 566 168,668.000
Engineer-in-charge. (Cement: CEM-II/B-M) ground floor. 298.0
wall, finishing the corner and edges including washing of sand, cleaning the surface, curing at least for 7 days, cost
of water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and accepted by the
55 Civil work 15.1.2 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to both inner-and outer surface of SqM 176 54,736.000
Engineer-in-charge. (Cement: CEM-II/B-M) ground floor. 311.0
wall, finishing the corner and edges including washing of sand, cleaning the surface, curing at least for 7 days, cost
of water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and accepted by the
56 Civil work 15.11.1 Making groove in plaster on outside wall upto 50 mm X 6 mm size including scaffolding, curing etc. complete as per meter 175 4,725.000
Engineer-in-charge. (Cement: CEM-II/B-M) 1st Floor. 27.0
drawing and accepted by the Engineer-in-charge.
57 Civil work 16.1.1 Exterior standard acrylic emulsion paint of approved best quality and color having water resisting properties and SqM 305 79,605.000
resistance properties against fungi, fading & flaking delivered from authorized local agent of the manufacturer in a 261.0
sealed container; applying to exterior surface with surface preparation including cleaning, drying, making free from
58 Civil work 16.2.1 Interior standard acrylic emulsion paint (plastic or matt finish) of approved best quality and colour delivered from SqM 685 167,825.000
dirt, grease, wax, removing all chalked and scaled materials, fungus, mending good the surface defects using sand 245.0
authorized local agent of the manufacturer in a sealed container; applying to interior wall and ceiling with surface
preparation including cleaning drying, making free from dirt, grease, wax, removing all chalked and scaled
59 Civil work 16.3.1 Standard synthetic enamel paint of approved best quality and colour delivered from authorized local agent of the SqM 21.9 4,730.400
materials, fungus, mending good the surface defects using sand paper and necessary scaffolding; applying necessary 216.0
manufacturer in a sealed container, having high water resistance, high bondibility, flexibility property; using
specified brand thinner applying to metallic or wooden surface by brass/roller/spray in 2 coats over single coat anti-
60 Civil work 16.9.1 Standard French polishing to Wooden board surface by three coats over a coat of priming including putty, cleaning, SqM 40.61 16,528.270
corrosive coating including cleaning, drying, making free from dirt, grease, wax, removing all chalked and scaled 407.0
finishing and polishing with sand paper etc. all complete in all floors and accepted by the Engineer-in-charge.
61 Civil work 16.7.2 Epoxy enamel paint of approved quality and colour delivered from authorized local agent of the manufacturer in a SqM 41.96 18,168.680
sealed container; surface preparation including cleaning, drying, making free from dirt, grease, wax, removing all 433.0
chalked and scaled materials, fungus (if required must be treated with fungicidal solution) flaking paints, washing
62 Civil work 17.4 Average 100 mm thick finished lime terracing with 20 mm down graded first class brick chips (khoa), surki from 1st CuM 20.2 342,935.400
the surface with soap water/caustic soda, mending good the surface defects, smoothening the surface by putty, sand 16,977.0
class bricks and minimum lime content 500 kg per 2.83 cubic meter (stone lime brought at site, not being powdered
in open air and to be slaked in presence of engineer-in-charge and to be measured in volume three days after slaking
63 Civil work 10.6 Supply, fabrication and installation of hot rolled structural grade steel channel and angle in roof truss or any form of Kg 56 7,224.000
for using in the mix) in the proportion 7:2:2 (brick chips : surki : lime) including preparation of the mix on the 129.0
structure of any thickness conforming to ASTM A36 with a minimum yield strength of 250 MPa, including the cost
of testing, application of red/grey-oxide primer etc. (up to level-4) all complete as per drawing, specification and
Total Tk. 7529903.890
direction of Engineer-in-charge.
3 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Electrical works 1.6 & 1.6.1.1 Concealed conduit wiring for following point looping at the switch board with earth teRMinal with 1C-2x1.5 sqmm Point 96 128736.000
PVC insulated and sheathed stranded cable (BYM) & same size PVC insulated ECC (BYA) (Green / White color) 1,341.00
including circuit wiring with IC-2x2.5 sqmm PVC insulated and sheathed stranded cable (BYM) & same size PVC
2 Electrical works 1.6.1.2 Fan point Point 4 5364.000
insulated ECC (BYA) Green / White color through PVC conduit (one conduit from switch board to common point 1,341.00
3 Electrical works 1.6.1.1 Exit light & Evacuation light Point 8 10728.000
1,341.00
4 Electrical works 1.15 & Concealed conduit wiring with following PVC insulated and sheathed stranded cable (BYM) & PVC Insulated RM 850 338300.000
1.15.1.3 Green/ White coloured ECC wire (BYA) though PVC Conduit of reputed manufacturer complete with 18 SWG GP 398.00
sheet and pull box with 3mm thick ebonite sheet cover, fixing materials etc. as required including mending damages
5 Electrical works 1.15 & lC-2x2.5sqmm(BYM ) cable with 2.5sqmm (BYA) ECC wire through PVC pipe of minimum inner dia 16 mm RM 1050 305550.000
goods. all electrical contacts shall be of brass / copper connected though connectoror soldering ( no twisting shall be 291.00
1.15.1.2 having wall thickness of1.5mm
6 Electrical works 1.17.2.4 1C-4x10mm2 (NYY/2XY)Cable with 10mm2 (BYA) ECC wirw through PVC Pipe of minimum inner dia 40mm, RM 15 18690.000
wall thciness 2.2 mm. 1,246.00
7 Electrical works 1.18, "Providing & laying of the following PVC insulated & sheathed cable (NYY) / (XLPE) insulated & PVC sheathed RM 130 397670.000
1.18.1.12 & cable (2XY) with PVC insulated Green / Yellow bi-colour ECC wire (BYA) connecting at both ends, through PVC 3,059.00
1.18.1.12.1 pipe & accessories in the following manner. All electrical contacts shall be of brass / copper connccted through
In Katcha Ground" 0.000
connector or soldering (no twisting shall be allowed) and cables shall be manutbctured and tested according to IEC /
22 Electrical works 6.10 & Providing & fixing the water tight light fitting of following manufacturers model & catalogue number suitable U- Each 9 12438.000
6.10.1.2 type glass cover (minimum total height of fitting 310mm), G.I wire net guard, brass holder, earth terminal, necessary 1,382.00
wiring with 2 x 0.4 sq.mm stranded PVC insulated flexible FR cable etc. complete. suitable for LED lamp (except
23 Electrical works 14.76 Supply and installation of "Exit light" complete with recgchargeable battery and charge light and other necessary Each. 4 14724.000
lamp) as per sample accepted / approved by the Engineer.Material: Aluminium aloy Aluminium Sheet, MS Sheet, GI 3,681.00
accessories suitable for AC / DC power supply (220V single phase) as per NFPA 101.
24 Electrical works 14.77 Supply and installation of "Evacuation light" (directional sign) complete with recgchargeable battery and charge Each. 2 8590.000
light and other necessary accessories suitable for AC / DC power supply (220V single phase) as per NFPA 101. 4,295.00
25 Electrical works 7.2 & Supply, Installation, Testing & commissioning of split type room air-cooler comprising condensing and evaporating Each 7 934101.000
7 .2.1.3.2 units having cooling capacity as mentioned below based on indoor temperature 27º-30ºC DB / 19.5º-22ºC WB and 133,443.00
outdoor temperature 35º-40ºC DB at high speed condition suitable for installation & operation in tropicalized
0.000
country like Bangladesh & standard as mentioned below:
(l ). Type : Compact weather proof outdoor type condensing unit, (2). Compressor : Hermitically sealed reciptocating 0.000
/ rotary compressor, (3). Refrigerant : lntemationally accepted & recommended and most commonly used gas (CFC
free), (4). Blower motor : Welt balanced type direct driven centrifugal type blower fan, (5). Power supply : (5.1).
0.000
200-250 V, singte phase, 50 Hz AC supply [up to 30000 BTU/HR], (5.2). 380-440 v 3-phase, 50 Hz, AC supplv
3 Nos. - 415V, l50A hard drawn electrolytic copper bus bar. I No. - 415V, 2.5 KVAR, 50 Hz TP power capacitor 0.000
bank with built in / separate discharge coil for connection directly with line through fuse. I No. - 4 | 5V, 2.5 KVAR,
50 Hz TP power capacitor bank with built in / separate discharge resistor. 5 No. - 415V. l0 KVAR,50 Hz TP power
37 Electrical works 4.19 & 4.19.6 Earthing System: Earthing the electrical installation with 40mm (1.5") dia G.I. pipe (Earth electrode) having 6.35mm Set 3 154608.000
caPac itor bank with built in / I No. - 415V, 5 KVAR, 50 Hz TP power capacitor bank with built in / separate 51,536.00
dia holes across the dia at 305mm interval securedly bonded with 2x2 SWG HDBC earth lead with washer, nuts,
bolts etc. sunk upto undermentioned depth and protection of earth lead by 20 mm dia G.I. pipe upto plinth level run
38 Electrical works 4.2 Construction of earthing inspection pit inside measurement 600 mm :i 600 mm with 250 mm thick brick in cement Each 3 22086.000
at a depth of 609.6mm (2 ft) below G.L. upto main board/test point to be earthed including necessary connecting 7,362.00
mortar (l:4) with l00mm thick RCC top slab ( I :2:4) with l7o re-enforcement 450 mm dia water sealed Cl man-hole
cover with locking anangement including necessary earth works' site filling and one brick flat soling 75 mm thick
39 Electrical works 5.7 & 5.7.6 Providing of following capacity multistage Bore-well Submersible water Pump Motor set manufactured according to set 1 151663.000
( I :3:6) base concrete for making inlet channel & l2mm thick (l:2) cement plastcr with neat finishing etc. all 151,663.00
relevant BDS standard and ISO 9906:2012. Crade 3B / DIN / NEMA / IEC / BS / VDE / JIS & ISO 9001:2015
standard. CE certitied / UL listed comprising of 2900 RPM, single/ three phase submersible rewindable type (oil /
40 Electrical works 21.22.3 & Providing & fixing 415V + 10 % , 50Hz three phase elechonics digital energy meter (KWH meter) steel body with Each 1 6587.000
water cooled ) motor having insulation: Class F & Protection : IP68 (minimum), suitable for operation at 230 /400 V 6,587.00
21.22.3.1 glass cover on prepared board inconformity with BDS IEC standard. l0- 100 Amps (Single Tariff)
41 Electrical works L.S Miscellaneous charges for obtaining permission for connection from DESA/DESCO/PDB/REB/Chief Electrical KW 45 90000.000
Advisor, Govt. of the Peoples Republic of Bangladesh including Security Deposit, HT metering fgees and licencing 2,000.00
Board fees etc.
42 Electrical works 10.3.2 Supply,installation,testing,commissioning multimedia projector including all necessary accessories & Each 1 54935.000
Wananty/Service Support of following technical speciflcation or equivalent: Projection lechnology: 3LCD 54,935.00
Technology, RGB liquid crystal shutter. LCD Panel: 0.59 inch with MLA (D9), lmage Size (Projected Distance): 33"
43 Electrical works 10.4 & Supply, installation, testing. commissioning multimedia projector screen (10'x7.5') including all necessary Each 1 20364.000
to 320" 1.68 m - 2.02 m ( 60 inch screen), Projector Lens: Optical, Lamp Type: UHE.210 W, 6,000 h durability, 20,364.00
10.4.5.2 accessories & Warranty/Service Support of following technical specificalion or equivalent: Motorized./ Electric
screen (Motorized 150" Diagonal)
44 Sound System 16.13.1 Supply, tnstallation, Testing & Commissioning of dual channel power amplifier including accessories of following Each 1 143091.000
Work technical specification or equivalent- Stereo Power Output: RMS (Dual Channels)- 8Ox2: 2l5W- 350W,4Ox2: 143,091.00
350W- 460W, Bridged Mono Power Output : RMS- 8Qx I : 700W- 950W, Frequency Response: 20Hz- 20 KHz,
45 Sound System 16.16.4 Supply, lnstallation, Testing & Commissioning of Wireless Microphones (Hand Held Type) of following technical Each 2 135322.000
Signal to Noise Ratio > 97 dB Total Harmonic Distortion (THD) <0.5%, Power Supply: 120 or 230 Vac 50Hz, 67,661.00
Work specification or equivalent- suitable for I transmitter, Preset with 16 selectable UHF channel, RF frequency range;
600 MHz-750MHz or any suitable carrier frequency range, Channel 16, Frequency Response: 50Hz-l8KHz,
46 Sound System 16.10 & Supply, Installation, Testing & Commissioning of Column / wall speaker ideal for airports, lounges, convention Each 3 72639.000
operating range 100m. CE Cenified/UL Listed Country of Origin: USA, UK, Japan. EU Countries; suitable for use 24,213.00
Work 16.10.3 centers, corporate boardrooms, hotels / hospitality, houses of worship, museums offrces, of patois, spaces schools,
theaters and theme parks, superior sound quantity, wide dispersion and smooth off-axis overage, superior sound
47 Sound System 16.28.2 Speaker cables, l2 AWG (copper made twin core shielded . PVC Jacket,PE Insulation. Dielectric srength: minimum Meter 150 22800.000
quality, wide dispersion and smooth off axis coverage, fast and easy installation of following technical specification 152.00
Work 500 Vac )
48 TV Line Work 4.15 & 4.15.1 TV socket (UK MEM/LEGRAND/GERMANY/ ENGLAND) Each 8 11344.000
1,418.00
49 TV Line Work TV Line 1.22.1.4 TV cable 40 4480.000
Work RG-11 112.00
50 TV Line Work 1.25 & 1.25.2 Providing & Iaying of following PVC pipe (besr quality PVC pipe of repured manufacturer) embedded in wall / RM 40 2000.000
column / ceiling / floor etc. with all accessories, l8 SWG GP sheet pull box with 3 mm ttrict ebonite street cover, 50.00
fixing materials etc. as required including mending the damages good. Minimum inner dia 20 mm & minimum wall
51 Intercom Work l7.l.1 Supply, installation, testing & commissioning of 6+8 line (extension capacity 24 line) digital PABX system. Basic Each 1 18017.000
thickness I .5 mm. 18,017.00
unit: 6+8 line PABX system; Hardware: (CPU card, T&T/ Land Line card, power supply unit & casing); Software:
System operating software & billing software; Features: Direct inward station access including necessary, AUTO /
52 Intercom Work 17.3.2.1 Supply, installation, testing & commissioning of single line telephone set for executive use with provision volume Each 3 7980.000
DISA (voice), CID (caller ID). card co-line card, etc. built in billing system automatic fax / phone switching key 2,660.00
up+ down, redial, flash etc.. including display with CID system (Min 30 Stations) complete.Suitable for use in
tropical country Iike Bangladesh complete with required accessories and in conformity to specified codes &
53 Internet Work 17.16.1 Supply. installation, testing & commissioning of router with following specification & features or equivalent as per Each 1 202575.000
specification of intemational standards & CE / UL /CSA certified. Model & sample to be approved by the Engineer 202,575.00
direction of the Engineer in charge.System features:Aggregate Throughput: 35 Mbps to 75 Mbps or above; Total
onboard WAN or LAN I0/100/1000 ports: 2; RJ-45-based ports: 2; SFP-based ports: I, Default memory double-data-
54 Internet Work 17.27 & Supply, installation, testing & commissioning of fiber optic cable (lndoor) with following specification or equivalent RM 70 8400.000
rate 3 (DDR3) error-conection-code (ECC) DRAM (Combined control/services/data planes): minimum 4 120.000
17.27.1 as per direction of the Engineer in charge.Specification:Armored single loose tube fiber optic cable (50 / 125 μm
multi-mode, 6-core) suitable for internal & extenal applications in ducts or intra-building links in campus
55 Fire works 14.1 & Supply & fixing the following capacities multi purpose ABC dry chemical powder stored pressure type with Each 5 9380.000
environments and having outer diameter of app. 6.5 mm and weight app. 35.0 kg / km etc.. complete with all 1,876.00
14.1.1.3 manometer system fire extinguisher suitable for repeated use complete with wall bracket, CO2 cartridge, easy
refilling system etc. as per sample accepted & approved by the Engineer. Mono Amonium Phosphate based 40%
56 Fire works 14.1.2.1 Supply & fixing the following capacities Carbon-di-Oxide type fire extinguisher suitable for repeated use complete Each 5 15515.000
ABC dry chemical agent & has a moisture-proof, anti-caking properties. Working pressure : 12 BAR minimum & 3,103.00
with wall bracket, discharge nozzle etc. as per sample accepted & approved by the Engineer.3 Kg. capacity.
57 Fire works 14.48 & Supply and installation of convcntional fire alarm control panel of following capacity with power supply unit, Each 1 86568.000
14.48.1 bateries and other accessories. The panel shall be complete with zone indicaling LED, fault indicarion and optional 86,568.00
telephonc jack erc. The panel shall have input 220V AC and output 24V DC. Panel shall be confirmed UL listed /
58 Fire works 14.49 Supply ard installation of conventional smoke delector complete with base. Shall be UL listed / FM approved. Shall Each 7 22813.000
FM approved.08 zonc capacity 3,259.00
have buih-in alarm LED. Powcr supply shall be 24VDC.
59 Fire works 14.5 Supply and installation of conventional heat detcctor complele with base. Shall be UL listed / FM approred. Shall Each 1 3259.000
have built-in alarm LED. Powcr supply shall be 24VDC. 3,259.00
60 Fire works 14.51 Supply and installation of convcntional type manual call poinl like break glass swilch or single action pull station Each 4 13852.000
complete with back box and all othcr accessories and consumables. Power supply shall be 24VDC. It shall bc UL 3,463.00
listcd / FM approved.
61 Fire works 14.78 & Surface conduit wiring with the following FPLR/ FPLP/ FPL type UL listed / FM Approved / LPCB Approved Meter 180 43020.000
14.78.1 cable. PVC lnsulation for each core shall be FR (Fire Rated) & Drain wire. shield (Aluminum Foil tape/ PET tape) 239.00
shall meet the minimum requircment as per NEC (National Eleclric Code) or NFPA 70 or BS. Jacket shall be Fire
Total Tk. 4470448.000
Rated. All electrical contacts shall be of brass / coppcr connected through connector or soldering (no twisling shall
4 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Sanitary works 26.01 & "Supplying, fitting and fixing of European type country made best quality glazed porcelain combi closet (two piece), Each 2 35418.000
26.01.6 including plastic seat cover with soft closing ,cistern system, water consumption 6 litre, siphon wash down/siphon jet 17,709.00
single or dual flushinging system which reduce water consumption, hygienic glaze in toilet bowl ,glaze in inner
" 0.000
waste line, round bowl, outlet range 280~305 mm.The sanitary ware shall conform BDS1162:2014. The glaze shall
0.000
"Approx. 702~ 750x 380~412 mm size, minimum 40.0 kg of weight, Equivalent to COTTO: C118 / RAK:Shino or 0.000
similar brand.
" 0.000
2 Sanitary works 26.05 & "Supplying, fitting and fixing of country made glazed vitreous standing bowl urinal. The sanitary ware shall conform Each 1 3436.000
26.05.01 BDS1162:2014. The glaze shall be thoroughly fused to body. The minimum thickness of body at any section shall be 3,436.00
5 mm. When assembled together and when examined from a distance of 60 cm, the outer surface shall not show to
" 0.000
the unaided eye, blemishes or defects in excess of those listed in BDS standard. The mean value of water absorption
3 Sanitary works 26.13 & "Supplying of country made glazed vitreous W/H wash basin of any color including pedestal.The sanitary ware shall 26.13.2 5 20170.000
conform BDS1162:2014. The glaze shall be thoroughly fused to body. The minimum thickness of body at any 4,034.00
section shall be 5 mm. When assembled together and when examined from a distance of 60 cm, the outer surface
" 0.000
shall not show to the unaided eye, blemishes or defects in excess of those listed in BDS standard. The mean value of
26.13.2 Approx. 457 x 406 mm, minimum weight 15.3 kg 0.000
4 Sanitary works 26.19 & Supplying, fitting and fixing of 5 mm thick unframed super quality double coated mirror with all necessary fitting Sqm 1.67 2844.010
26.19.2 including making holes in walls and mending good the damages with cement mortar (1:4) etc. all complete approved 1,703.00
and accepted by the Engineer-in-charge.
0.000
5 Sanitary works 26.21 Supplying, fitting and fixing of super quality 600 x 125 mm white glass (plate) shelf having 5 mm thickness with Each 2 2020.000
fancy C.P. brackets, screws and frames including making holes in walls and mending good the damages with cement 1,010.00
mortar (1:4) etc. all complete approved and accepted by the Engineer- in charge.
6 Sanitary works 26.22 & Supplying, fitting and fixing of country made best quality towel rail/ring/shelf minimum 20 mm in dia with C.P. Each 3 2142.000
26.22.1 holder including making holes in walls and mending good the damages with cement mortar (1:4) etc. all complete 714.000
approved and accepted by the Engineer- in- charge.
0.000
7 Sanitary works 26.23 & Supplying, fitting and fixing of best quality toilet paper holder of standard size including making holes in walls and Each 2 576.000
26.23.1 mending good the damages with cement mortar (1:4) etc. all complete approved and accepted by the Engineer- in- 288.000
charge.
0.000
8 Sanitary works 26.26 & Supplying, fitting and fixing of Push-Up type liquid soap dispenser to dispense 16 oz (.47 liters) of soap, detergent or Each 3 3975.000
26.26.1 lotion. Unit shall be fabricated of tamper resistant, chrome plated plastic, a translucent white polyethylene soap 1,325.000
container, and a corrosion resistant dispensing valve which can provide no more than 5 lbs (22.2 Newtons) pressure
0.000
and unit can be reloaded by unscrewing base from bracket collar, inverting unit, and unscrewing soap container in
9 Sanitary works 26.27 & "Supplying, fitting and fixing of floor grating net in traps or in drains including making holes in walls/floors and Each 5 4920.000
26.27.5 mending good the damages with cement mortar (1:4) etc. all complete approved and accepted by the Engineer- in- 984.000
charge. of following type.
" 0.000
10 Sanitary works 26.30 & "Supplying, fitting and fixing of best quality surface mounted or conceal stop cock/angle stop cock (lever or round Each 16 18288.000
26.30.1 headed) with wall flange chromium plated. The faucet conforms BDS EN 200:2009. The faucet tap shall be free 1,143.000
from any leakage, permeation and other abnormalities. The water hammer value shall be 1.47 Mpa or under. The
" 0.000
faucet after it has been operated 100000 times it shall be free from a seat- leakage and shall satisfy the reverse flow
0.000
11 Sanitary works 26.31 & "Supplying, fitting and fixing of best quality pillar cock made from copper or copper alloy, chromium plated Each 5 9400.000
26.31.5 materials. The faucet conforms BDS EN 200:2009. The faucet tap shall be free from any leakage, permeation and 1,880.00
other abnormalities. The water hammer value shall be 1.47 Mpa or under. The faucet after it has been operated
" 0.000
100000 times it shall be free from a seat- leakage and shall satisfy the reverse flow preventing performance. The
0.000
12 Sanitary works 26.43 & "Supplying different inside dia best quality uPVC soil, waste and ventilation pipe having specific gravity 1.35 - 1.45, meter 12.19 6594.790
26.43.1 wall thickness 2.5 mm - 3.0 mm, and other physical, chemical, themal, fire resistivity properties etc. as per BSTI 541.000
approved manufacturer standards or ASTM, BS/ISO/IS standards fitting and fixing in position with sockets, bends,
of uPVC Pipe with all accessories such as Round grating /domed roof grating bands, sockets etc. approved and
" 0.000
0.000
13 Sanitary works 26.43.2 100 mm inside dia wall thickness 3.4- 4.0 mm meter 15.23 13158.720
864.000
14 Sanitary works 26.43.3 150 mm inside dia wall thickness 4.5 mm - 5.2 mm meter 65.52 103128.480
1,574.00
15 Sanitary works 26.46 & "Supplying different inside dia best quality CPVC pressure pipe for water supply having specific gravity 1.35 - 1.45, meter 15.29 3929.530
26.46.1 and other physical, chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer standards or 257.000
ASTM, BS/ISO/IS standards fitting and fixing in position with sockets, bends, with all accessories such as round
" 0.000
grating/domed roof grating, bends, sockets etc. approved and accepted by the Engineer-in charge.
0.000
16 Sanitary works 26.46.3 25 mm dia wall thickness 3.4 mm - 4.0 mm meter 18.28 8061.480
441.000
17 Sanitary works 26.46.5 37 mm dia wall thickness 2.5 mm - 3.1 mm meter 4.57 3930.200
860.000
18 Sanitary works 26.46.6 50 mm dia wall thickness 3.0 mm - 3.9 mm meter 15 22095.000
1,473.00
19 Sanitary works 26.58 & Supplying, fitting and fixing of food graded plastic overhead water reservoir /tank including all necessary fittings, Each 1 29,728.0 29728.000
26.58.4 hardware and consumables etc. all complete approved and accepted by the Engineer- in- charge.
0.000
20 Sanitary works 26.61 & Supplying, fitting and fixing of 12 mm dia connection pipe approved and accepted by the Engineer- in- charge. Each 2 108.000 216.000
26.61.1
0.000
21 Sanitary works 26.62 & "Supplying, fitting, fixing of foreign made best quality Reverse Osmosis Water Purifier (Kent/Unilever/Vapor water Each 1 18577.000
26.62.1 purifier or equivalent brand) for purification of water by reverse osmosis system to have potable water conforming 18,577.0
WHO standard and Bangladesh concentration parameters including installation charge, carriage, sundries etc.
" 0.000
complete approved and accepted by the Engineer-in- charge.
0.000
22 Sanitary works 26.68 Punching or cutting hole of any diameter in RCC floor for sanitary works. Each 6 1110.000
185.000
23 Sanitary works 26.74 & Construction of septic tank of different sizes with walls of brick work in cement mortar (1:6) having a lining of each 1 136453.000
26.74.3 minimum 125 mm R.C.C cast against the walls as per approved type plan over a brick flat soling and 150 mm thick 136,453.0
reinforced cement concrete flooring (1:2:4) with 125 mm thick walls in partition and 12 mm thick cement plaster
0.000
(1:4) with N.C.F. to insides of walls on floor and all around outside walls by 450 mm height at top including
0.000
50 users 0.000
25 Sanitary works 26.70 & Construction of masonry inspection pit with 250 mm thick brick work in cement mortar (1:4) including necessary each 20 77340.000
26.70.1 earth work, side filling and one layer brick flat soling, 75 mm thick (1:3:6) base concrete for making invert channel 3867.00
and 12 mm thick (1:2) cement plaster with neat finishing etc. all complete up to a depth of 700 mm approved and
0.000
accepted by the Engineer- in- charge.
"Clear 450 mm x 450 mm and depth 450 mm to 600 mm, average 525 mm for single 150 mm dia R.C.C pipes and 0.000
400 mm PVC pipe.
" 0.000
26 Sanitary works 26.70.4 Master-pit of Size: Clear 600 mm x 500 mm and average 750 mm depth for Septic tank. each 1 3796.000
3796.00
27 Sanitary works 26.72 & Construction and placing of R.C.C inspection pit cover (slab) with supplying and provisions for placing, fitting, each 21 43176.000
26.72.1 fixing 450 mm dia C.I. man-hole cover with locking/un-locking arrangement including concrete (1:2:4) with approx. 2056.00
1% re-enforcement, necessary earth cutting, or cleaning, side filling, curing etc. with minimum 12 mm cement
0.000
plaster (1:4) and neat cement finishing on edges and top all complete and accepted by the Engineer- in- charge.
950 mm x 950 mm x 75 mm R.C.C. pit cover with 450 mm dia C.I. manhole cover. 0.000
28 Sanitary works 26.73 & Construction of masonry inspection pits up to a depth of 700 mm with 250 mm thick brick work in cement mortar Each 1 10373.000
26.73.3 (1:4) including 100 mm thick R.C.C. top slab (1:2:4) with 1% reinforcement, man-hole cover with locking 10373.00
arrangement including necessary earth work, side filling and one brick flat soling. 75 mm thick (1:3:6) base concrete
0.000
for making invert channel and 12 mm thick (1:2) cement plaster with neat finishing etc. all complete approved and
"Clear 600 mm x 600 mm and depth 750 mm to 900 mm, average 825 mm for single 300 mm dia R.C.C.pipes and 0.000
375 mm and 400 mm PVC pipe with pit cover and 450 mm dia C.I. man-hole cover.
" 0.000
29 Sanitary works 27.1 Mobilization of test boring or observation well: Transportation of materials, equipments, tools and plants and boring Per set 1 7853.000
rig to work site. Construction of derrick and dismantling the same. Cleaning the site after completion of the work 7853.00
accepted by the Engineer-in-charge.
30 Sanitary works 27.2 & 27.2.1 Boring by using 100 mm dia cutter and 40 mm dia heavy type G.I pipe (wall thickness 2.9 mm, outside diameter min meter 50 9800.000
47.8 mm, weight 3.517 kg/m, capable to withstand 50 kg/cm2 pressure) and other equipments capable of drilling up 196.00
to a depth of 500 meter by water jet system through all sorts of soil strata providing protection of caving by
0.000
supplying necessary casing pipe. Collection of soil samples at every 3 meter interval and at every change of soil
33 Sanitary works 27.19.2.1 75 mm dia water grade(Class D) uPVC blind pipe/sand trap of wall thickness 4.6 mm to 5.3 mm meter 88 45584.000
518.00
34 Sanitary works 27.19.3.1 75 mm dia strainer of any slot as per design made with water grade (Class D) uPVC pipe of wall thickness 4.6 mm to meter 12 7092.000
5.3 mm 591.00
Total Tk. 771526.210
Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m lead 0.000
2 Main Gate 02.1.1 Layout and marking for earthwork in excavation in foundation accepted by the Engineer-in-charge. [Plinth area of SqM 11.61 208.980
the structure shall be considered for measurement] 18.00
3 Main Gate 3.4 & 3.4.1 Lean / blinding concrete (1:3:6) in foundation or in floor with cement, sand (F.M. 1.2) and picked jhama brick chips CuM 2.12 16222.240
including breaking of chips, screening, mixing, laying, compacting to required level and curing for at least 7 days 7,652.00
including the supply of water, electricity, costs of tools & plants and other charges etc. all complete and accepted by
0.000
the Engineer-in-charge.(Cement: CEM-II/B-M)
Blinding concrete in foundation (1:3:6) with cement, brick chips and sand of F.M. 1.2 0.000
4 Main Gate 2.13 Earth filling in foundation trenches and plinth in 150 mm layer with earth available within 90 m of the building site CuM 14.12 2668.680
to achive minimum dry density of 95% with optimum moisture content (Modified proctor test) including carrying 189.00
watering, leveling, dressing and compacting to a specified percentage each layer up to finished level etc. all complete
5 Main Gate 7.1 & 07.1.1 Reinforced cement concrete works with minimum cement content relates to mix ratio 1:2:4 having maximum water CuM 3 8521.00 25563.000
and accepted by Engineer-in-charge.
cement ratio = 0.45 and minimum f'cr = 26 MPa, satisfying a specified compressive strength f'c= 19 MPa at 28 days
on standard cylinders as per standard practice of Code ACI/BNBC/ASTM, cement conforming to BDS EN-197-1-
CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type ? I, best quality sand [50% quantity of best local sand (F.M. 1.2)
0.000
0.000
Individual & combined footing, pile cap, raft/mat, floor slab and foundation beam up to plinth level 0.000
6 Main Gate 07.1.2 Pedestal, column, column capital, lift wall and wall up to ground floor CuM 2.83 8853.00 25053.990
7 Main Gate 07.1.3 " Floor / Roof slab, T-beam, L-beam and rectangular beam, tie beam, lintel, stair case slab and step etc. up to ground CuM 2.04 17654.160
floor. 8654.00
" 0.000
8 Main Gate 7.18 & FORMWORK (Wooden) for boundary wall, gate, centry post etc .Centering and shuttering, including strutting, SqM 6.6 3313.200
07.18.1 propping etc. and removal of form for: 502.00
0.000
14 Main Gate 15.12 Minimum 10 mm thick fair face plaster using premix cement plaster (CP2 LGT/Stucco base premix or equivalent); SqM 52 103532.000
initial background should be 19 mm rough cement plaster (1:4); then after passing 7 days curing time surface of 1991.00
newly constructed rough plaster should be throughly cleaned using a stiff brush to remove any dust, loose particles,
15 Main Gate 15.13.1 Making groove in fair face plaster on outside wall upto 50 mm X 6 mm size including scaffolding, curing etc. meter 23.16 1227.480
wood pieces, mould oil etc, then the backgound needs to be throughly neutralized by applying potable water; Mixing 53.00
complete as per drawing and accepted by the Engineer-in-charge.
16 Main Gate 15.14 "Minimum 1mm thick fair face coating using Master Emaco N 303 Rendroc FC/Top Crete 220 or equivalent product SqM 52 77792.000
micro toping skim coat, a high performance single component polymer fortified, colored, cementitious micro topping 1496.00
that can be applied on a variety of horizontal and vertical plaster surfaces; initially background should be thoroughly
" 0.000
cleaned using a stiff brush to remove any dust, loose particles, mould oil etc.; then the background needs to be
17 Main Gate 19.9 & 19.9.2 Manufacturing, supplying, fitting and fixing SS Swing front gate of any design and shape made of 50 mm x 50mm x SqM 11.15 160303.550
1.5 mm S.S. box section as outer frame, 37mm x 37mm x 1.5 mm SS box section as vertical section @ 100 mm c/c 14377.00
fitted with outer frame, 25 mm x 25 mm x 1.5 mm SS box section as horizontal section , 37 mm x 1.5 mm SS round
18 Main Gate 1.2 & 1.2.1.1 SURFACE CONDUIT POINT WIRING (BYM) (WITHOUT SWITCH) Surface conduit wiring for following point Point 3 3837.000
section fitted with vertical outer section for SS lettering, 25 mm dia SS solid round pipe, placing required number of 1279.00
looping at the switch board with earth terminal with 1C-2x1.5sq.mm PVC insulated and seathed standard cable
(BYM) & 1C-2X1.5sqmm. PVC insulated ECC (BYA) (Green / Yellow bi- colour) including circuit wiring (from
0.000
SDB to switch board) with 1C-2x2.5sqmm. PVC insulated and Sheathed standard cable (BYM) and 1C-
19 Main Gate 1.9 & 1.9.1.2 Channel wiring (BYA)Surface channe wiring with the following PVC insulated standard cable (BYA) & Green RM 20 3760.000
/Yellow by colour PVCinsulated ECC wire (BYA) through minimum 1mm thick PVC channel complete with fixing 188.00
materials, other accessories etc. as required including mending the damages good. all electrical contacts shall be of
0.000
brass / copper connected through connector or soldering (no twisting shall be allowed) and cables shall be
1C-2x2.5 sqmm (BYA) cable with 2.5 sqmm (BYA) ECC wire 0.000
20 Main Gate 4.12 GANG SWITCH:Providing & fixing 250 volts 5/6 amps (minimum) concealed type following switch / switch socket Each 5 2325.000
manufactured/assembled and tested in accordence with IEC/VDE/NEMA/BS/JIS along with relevant BDS/IEC 465.00
standards mounted on required size 18 SWG galvanized plain sheet / PVC board (self-extinguishing 650˚C) of 76.2
21 Main Gate 4.12.2.1 & Made in Hongkong/ Malyasia/ Singapore/ South Korea/ Thailand Each 1 375.000
mm (3'') depth. all electrical contacts shall be of bass / copper. 375.00
4.12.2.2
0.000
22 Main Gate 4.4 & 4.4.1.1 CIRCUIT BREAKER (SPMCB)Providing and fixing on a prepared board 250 volt grade following single pole Each 1 779.000
miniature circuit breaker (SPMCBS) having minimum breaking capacity 6-KA /10 KA with thermal over-current 779.00
and instaneous electromagnetic short circuit release provision as per BDS / IEC and IEC/VDE/ NEMA/ BS/JIS
23 Main Gate - Supply & fixing of the following energy savings lamp (CFL) having Illuminate even at low voltage as 110 volts. Each 3 990.000
standards. 5-40 Amps(minimum 6 KA) MCB 330.00
Built in short circuit & over voltage protection feature & 8000 hrs. (minimum) lifetime, 230V / 250V, 50HZ
manufacturers by OSRAM / PHILIPS /ENERGYPAC / CBE / CORONA / HAVELLS/ GE EDISION I EASTERN /
PRODIP / MEP / METRO / HARMONICS / SUPERSTAR / TRANSTEC / ENERGY+ or equivalent brand Total Tk. 561041.02
3 Road Pavement- 03.1.1 One layer brick flat soling in foundation or in floor with first class/picked jhama bricks (BDS 208) including SqM 237.25 118625.000
Civil work preparation of bed and filling the interstices with local sand, leveling etc. complete and accepted by the Engineer-in- 500.0
charge
4 Road Pavement- 3.4 & 3.4.1 Lean / blinding concrete (1:3:6) in foundation or in floor with cement, sand (F.M. 1.2) and picked jhama brick chips CuM 0.39 2984.280
Civil work including breaking of chips, screening, mixing, laying, compacting to required level and curing for at least 7 days 7,652.0
including the supply of water, electricity, costs of tools & plants and other charges etc. all complete and accepted by
0.000
the Engineer-in-charge.(Cement: CEM-II/B-M)
Lean / blinding concrete in foundation (1:3:6) with cement,brick chips and sand of F.M.1.2 0.000
5 Road Pavement- 02.10.1 Sand filling in foundation trenches and plinth with sand having minimum F.M. 0.5 in 150 mm layers including CuM 82.55 88245.950
Civil work leveling, watering and compaction to achieve minimum dry density of 95% with optimum moisture content 1,069.0
(Modified proctor test) by ramming each layer up to finished level as per design supplied by the design office only,
6 Road Pavement- 3.7 Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor or any SqM 289.9 13335.400
all complete and accepted by the Engineer-in-charge. 46.0
Civil work where below cement concrete complete in all respect and accepted by Engineer-in-charge.
7 Road Pavement- 4.1 Brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:6) in foundation and plinth, filling the CuM 7.8 56752.800
Civil work joints/interstices fully with mortar, racking out the joints, cleaning and soaking the bricks at least for 24 hours before 7,276.0
use and curing at least for 7 days etc. all complete including cost of water, electricity and other charges and accepted
8 Road Pavement- 7.2 & 07.2.3 Reinforced cement concrete works with minimum cement content relates to mix ratio 1:2:4 having maximum water CuM 35.75 459637.750
by the Engineer-in-charge. (Cement: CEM-II/B-M) 12,857.0
Civil work cement ratio = 0.40 and minimum f'cr = 30.5 MPa, satisfying a specified compressive strength f'c = 22 MPa at 28
days on standard cylinders as per standard practice of Code ACI/BNBC/ASTM, cement conforming to BDS EN-
0.000
197-1-CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type ? I, best quality Sylhet sand or coarse sand of equivalent F.M.
"Floor / Roof slab, T-beam, L-beam and rectangular beam, Tie beam, lintel, stair case slab and steps etc. up to 0.000
ground floor.
" 0.000
9 Road Pavement- 8.1.3 "Grade 500 (B500DWR: complying BDS ISO 6935-2:2016 / ASTM A615) ribbed or deformed bar produced and Kg 2015 189410.000
Civil work marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 500 MPa and whatever is the 94.0
yield strength within allowable limit as per BNBC/ ACI 318, the ratio of ultimate tensile strength fu to actual yield
" 0.000
strength fy, shall be at least 1.25 and minimum elongation after fracture and minimum total elongation at maximum
10 Road Pavement- - Expansion Sheet( Foam-25mm thickness) @6.09m c/c. as per BDS standard. RM 34.45 5167.500
Civil work 150.00
Total Tk. 960464.180
8 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Surface Drain 1.6 Providing layout and carry over PWD bench-mark (BM) at site from nearby BM pillar, property lines, existing SqM 96.2 2886.000
ground level (EGL), formation ground level (FGL), highest flood levels (HFL), plinth levels (PL), mean sea level 30.00
(MSL), setting and marking all pillars, marker, pegs etc. showing and maintaining reduced levels (RL's) including
2 Surface Drain 02.1 & 02.1.1 Earth work in excavation in all kinds of soil for foundation trenches including layout, providing center lines, local SqM 72.15 1298.700
locating, establishing, protecting all public utilities within the premise of work and finally all to be presented in black 18.00
bench-mark pillars, levelling, ramming and preparing the base, fixing bamboo spikes and marking layout with chalk
powder, providing necessary tools and plants, protecting and maintaining the trench dry etc., stacking, cleaning the
excavated earth at a safe distance out of the area enclosed by the layout etc. all complete and accepted by the
Layout and marking for earthwork in excavation in foundation accepted by the Engineer-in-charge. [Plinth area of
the structure shall be considered for measurement]
3 Surface Drain 02.1.2 Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m lead CuM 60.45 9248.850
153.00
4 Surface Drain 02.10.1 Sand filling in foundation trenches and plinth with sand having minimum F.M. 0.5 in 150 mm layers including CuM 16.25 17371.250
leveling, watering and compaction to achieve minimum dry density of 95% with optimum moisture content 1069.00
(Modified proctor test) by ramming each layer up to finished level as per design supplied by the design office only,
5 Surface Drain 03.1.1 One layer Brick flat soling in foundation or in floor with first class/picked jhama bricks (BDS 208) including SqM 72.15 36075.000
all complete and accepted by the Engineer-in-charge. 500.00
preparation of bed and filling the interstices with local sand, leveling etc. complete and accepted by the Engineer-in-
charge
6 Surface Drain 03.4.1 Lean/blinding concrete in foundation (1:3:6) with cement, brick chips and sand of F.M. 1.2 CuM 5.2 39790.400
7652.00
7 Surface Drain 3.7 Supplying and laying of Single layer polythene weighing one kilogram per 6.5 square meter in floor or any where SqM 72.15 3318.900
below cement concrete complete in all respect and accepted by Engineer-in-charge. 46.00
8 Surface Drain 4.1 Brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:6) in foundation and plinth, filling the CuM 19.5 141882.000
joints/interstices fully with mortar, racking out the joints, cleaning and soaking the bricks at least for 24 hours before 7276.00
use and curing at least for 7 days etc. all complete including cost of water, electricity and other charges and accepted
9 Surface Drain 15.2 Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing to plinth wall with cement (1:4) up SqM 151.45 51493.000
by the Engineer-in-charge. (Cement: CEM-II/B-M) 340.00
to 150 mm below ground level including washing of sand, finishing the edges and corners and curing at least for 7
days, cost of water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and
Total Tk. 303364.100
accepted by the Engineer-in-charge. (Cement: CEM-II/B-M) ground floor.
9 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Land 2.16 & 2.16.2 "Site development/Improvement by carted earth or dredged sand, sandy silt (free from any organic, foreign, CuM 536.35 270320.400
Development environmental hazardous substances) carried by head or by truck or by any other means including cost of cutting or 504.00
Works by dredging of sand, sandy silt including local carrying, placing the earth/sand, sandy silt in the designated area,
"
maintaining slopes, breaking lumps, levelling and dressing in layers up to finished level etc. all complete as per
2 Land 2.17 "Mechanical compaction of earth beyond plinth area, required for pre-approved specific engineering purpose in 150 CuM 46 9568.000
Development mm layers including levelling, watering and consolidation each layer with chain dozer, grader, roller etc. to achieve 208.00
Works minimum dry density of 95% with optimum moisture content (modified proctor test) up to finished level all
submission of the method statement.
complete and accepted by the engineer-in-charge subjected to
"
3 Land 25.3 Leveling and dressing of lawn area to proper slope and grade by spading the same up to 150 mm including supplying SqM 896 7168.000
Development tools and plants etc. all complete and accepted by the Engineer-in-charge. 8.00
Works
Total Tk. 287056.400
10 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Boundary wall 02.1 & 02.1.2 Earth work in excavation in all kinds of soil for foundation trenches including layout, providing center lines, local CuM 41.56 6358.680
bench-mark pillars, levelling, ramming and preparing the base, fixing bamboo spikes and marking layout with chalk 153.00
powder, providing necessary tools and plants, protecting and maintaining the trench dry etc., stacking, cleaning the
excavated earth at a safe distance out of the area enclosed by the layout etc. all complete and accepted by the
Earthwork in excavation in foundation trenches up to 1.5 m depth and maximum 10 m lead 0.000
2 Boundary wall 02.1.1 Layout and marking for earthwork in excavation in foundation accepted by the Engineer-in-charge. [Plinth area of SqM 42.48 764.640
the structure shall be considered for measurement] 18.00
3 Boundary wall 3.4 & 3.4.1 Lean / blinding concrete (1:3:6) in foundation or in floor with cement, sand (F.M. 1.2) and picked jhama brick chips CuM 1.86 14232.720
including breaking of chips, screening, mixing, laying, compacting to required level and curing for at least 7 days 7652.00
including the supply of water, electricity, costs of tools & plants and other charges etc. all complete and accepted by
0.000
the Engineer-in-charge.(Cement: CEM-II/B-M)
Blinding concrete in foundation (1:3:6) with cement, brick chips and sand of F.M. 1.2 0.000
4 Boundary wall 03.1.1 One layer brick flat soling in foundation or in floor with first class/picked jhama bricks (BDS 208) including SqM 51.67 25835.000
preparation of bed and filling the interstices with local sand, leveling etc. complete and accepted by the Engineer-in- 500.00
charge
5 Boundary wall 2.13 Earth filling in foundation trenches and plinth in 150 mm layer with earth available within 90 m of the building site CuM 31.23 5902.470
to achive minimum dry density of 95% with optimum moisture content (Modified proctor test) including carrying 189.00
watering, leveling, dressing and compacting to a specified percentage each layer up to finished level etc. all complete
6 Boundary wall 7.1 & 07.1.1 Reinforced cement concrete works with minimum cement content relates to mix ratio 1:2:4 having maximum water CuM 17.22 146731.620
and accepted by Engineer-in-charge. 8521.00
cement ratio = 0.45 and minimum f'cr = 26 MPa, satisfying a specified compressive strength f'c= 19 MPa at 28 days
on standard cylinders as per standard practice of Code ACI/BNBC/ASTM, cement conforming to BDS EN-197-1-
0.000
CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type ? I, best quality sand [50% quantity of best local sand (F.M. 1.2)
Individual & combined footing, pile cap, raft/mat, floor slab and foundation beam up to plinth level 0.000
7 Boundary wall 07.1.2 Pedestal, column, column capital, lift wall and wall up to ground floor CuM 5.96 8853.00 52763.880
8 Boundary wall 07.1.3 " Floor / Roof slab, T-beam, L-beam and rectangular beam, tie beam, lintel, stair case slab and step etc. up to ground CuM 1.14 9865.560
floor. 8654.00
" 0.000
9 Boundary wall 7.18 FORMWORK (Wooden) for boundary wall, gate, centry post etc .Centering and shuttering, including strutting, SqM 34 17068.000
propping etc. and removal of form for: 502.00
0.000
14 Boundary wall 15.1.1 Minimum 12 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to both inner-and outer surface of SqM 533.1 149801.100
wall, finishing the corner and edges including washing of sand, cleaning the surface, curing at least for 7 days, cost 281.00
of water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and accepted by the
15 Boundary wall 16.1.1 Exterior standard acrylic emulsion paint of approved best quality and color having water resisting properties and SqM 533.1 139139.100
Engineer-in-charge. (Cement: CEM-II/B-M) ground floor. 261.00
resistance properties against fungi, fading & flaking delivered from authorized local agent of the manufacturer in a
sealed container; applying to exterior surface with surface preparation including cleaning, drying, making free from
16 Boundary wall 1.2 & 1.2.1.1 SURFACE CONDUIT POINT WIRING (BYM) (WITHOUT SWITCH) Surface conduit wiring for following point Point 24 30696.000
dirt, grease, wax, removing all chalked and scaled materials, fungus, mending good the surface defects using sand 1279.00
looping at the switch board with earth terminal with 1C-2x1.5sq.mm PVC insulated and seathed standard cable
(BYM) & 1C-2X1.5sqmm. PVC insulated ECC (BYA) (Green / Yellow bi- colour) including circuit wiring (from
0.000
SDB to switch board) with 1C-2x2.5sqmm. PVC insulated and Sheathed standard cable (BYM) and 1C-
1C-2x1.5 sqmm (BYA) cable with 1.5 sqmm (BYA) ECC wire 0.000
18 Boundary wall 4.12 & 4.12.2 GANG SWITCH:Providing & fixing 250 volts 5/6 amps (minimum) concealed type following switch / switch socket Each 24 5232.000
& 4.12.2.1 manufactured/assembled and tested in accordence with IEC/VDE/NEMA/BS/JIS along with relevant BDS/IEC 218.00
standards mounted on required size 18 SWG galvanized plain sheet / PVC board (self-extinguishing 650˚C) of 76.2
0.000
mm (3'') depth. all electrical contacts shall be of bass / copper.
0.000
19 Boundary wall - Supply & fixing of the following Energy savings lamp (CFL) having Illuminate even at low voltage as 110 volts. Each 72 23760.000
Built in short circuit & over voltage protection feature & 8000 hrs. (minimum) lifetime, 230V / 250V, 50HZ 330.00
manufacturers by OSRAM / PHILIPS /ENERGYPAC / CBE / CORONA / HAVELLS/ GE EDISION I EASTERN /
Total Tk. 879557.110
PRODIP / MEP / METRO / HARMONICS / SUPERSTAR / TRANSTEC / ENERGY+ or equivalent brand
10 Item Group Item Code Description of Item Measureme Quantity Unit Price Total Price
no. (if any) nt Unit
1 Name plate and - Name plate and logo, Materials SS (Stainless steel), Thickness 2mm-4mm, all complete and accepted by the LS 1 50000.000
Logo Engineer-in-charge. 50000.00
2 MS Collapsible 19.1.3 Manufacturing, supplying, fitting and fixing M.S. collapsible gate of any design and shape made of 25 mm x 25 mm SqM 12.36 72058.800
gate x 3 mm M.S. angle placed @ 112 mm c/c vertically and connecting the same with each other by 25 mm x 3 mm M.S 5830.00
flat bar scissors 525 mm, 600 mm long provided in 3 rows including cutting the different M.S. members to required
Total Tk. 122058.800
sizes, fabricating, welding, riveting with required size rivets, providing required size wheels, pulling handles on both
322,569.71