You are on page 1of 4

CONCRETE DESIGN OF SLOPED FOOTING 07/13/2020

Concrete Mix
R.C.C. DESIGN OF RECTANGULAR SLOPED FOOTING
Job: INT/MES/694/2018 Footing Category: F1 M25
M30
Steel Grade
FE-250
FE-415
FE-500
Reinforcement
Ø8
Ø10
Ø12
Ø16
Ø20
1. INPUT DATA (Design Based on Indian Standards Code IS:456-2000)

Grade of Concrete fck = 30 N/mm2 Exposure


Grade of Steel 'fy' fy = 500 N/mm2 Very Severe
Proposed Reinforcement Dia. Ø = 16 mm Extreme
Clear Cover to Reinforcement c = 75 mm Footing Depth
Maximum upward pressure or SBC q0.max = 100 kN/m At Column Face
2

Column/Pedestal Length a = 0.10 m ###


---------|---------
diagram above
As shown in

Column/Pedestal Width b = 0.10 m ###


Footing Length L = 0.60 m ###
\

Footing Width W = 0.60 m ###


Area Provided A = 0.36 m2 ###
/

2. DEPTH CALCULATION
Factored upward pressure; Q = q0.maxϒƖ (ϒƖ=1.5) Q = 150 kN/m2 ###
Bending moment at - XX Mux = 2.03 kNm ###
Depth required in bending at - XX Dreq.x = 71.08 mm ###
Bending moment at - YY Muz = 2.03 kNm ###
Depth required in bending at - YY Dreq.z = 71.08 mm ###
Hence, depth required from Bending Dreq = 72 mm ###
Depth Provided at column face Dprov = 300 mm ###
Depth Provided at free end dprov = 300 mm ###
Effective depth at critical section D' = 217 mm ###
HENCE, DEPTH PROVIDED IS SATISFACTORY IN BENDING ###
3. REINFORCEMENT CALCULATION
Nominal Bending Stress Mu/bd2 at - XX σƒx = 0.43 N/mm2 ###
Corresponding Reinforcement % from SP16 preq.x = 0.11 % ###
Ast required in bending at XX Ast.Req = 22 mm2 ###
Min. Ast required at XX Ast.Min = 216 mm2 ###
Required bar spacing across 'L' Sreq.x = 558 mm c/c ###
Provided bar spacing across 'L' Sprov.x = 150 mm c/c
Nominal Bending Stress Mu/bd2 at - YY σƒy = 0.43 N/mm2
Corresponding Reinforcement % from SP16 preq.y = 0.11 %
Ast Required in bending at YY Ast.Req = 22 mm2
Min. Ast required at YY Ast.Min = 216 mm2

Page 1 of 4
CONCRETE DESIGN OF SLOPED FOOTING 07/13/2020
Required bar spacing across 'W' Sreq.y = 558 mm c/c
Provided bar spacing across 'W' Sprov.y = 150 mm c/c

5. CHECK FOR BENDING/ONE-WAY SHEAR ALONG 'L'


Depth at Critical Section along L dcx = 300 mm
Width at Critical Section || to XX XX' = 534 mm
One way shear force in XX' Vux = 3 kN
Nominal Shear Stress in Concrete τvXX' = 0.02 N/mm2
% Reinforcement provided across L ptx = 0.447 %
Permissible Bending Shear Stress in Concrete τc = 0.474 N/mm2

HENCE, FOOTING IS SAFE IN BENDING/ONE-WAY SHEAR ALONG 'L'

4. CHECK FOR BENDING/ONE-WAY SHEAR ALONG 'W'


Depth at Critical Section along W dcy = 300 mm
Width at Critical Section || to YY YY' = 534 mm
One way shear force in YY' Vuy = 3 kN
Nominal Shear Stress in Concrete τvYY' = 0.02 N/mm2
% Reinforcement provided across W pty = 0.447 %
Permissible Bending Shear Stress in Concrete τc = 0.474 N/mm2

HENCE, FOOTING IS SAFE IN BENDING/ONE-WAY SHEAR ALONG 'W'

6. CHECK FOR TWO-WAY/PUNCHING SHEAR


Depth at Critical Section along L (dpx @ distance D'/2 from XX) = 253 mm
Depth at Critical Section along W (dpy @ distance D'/2 from YY) = 253 mm
Width at Critical Section along L XX" = 317 mm
Width at Critical Section along W YY" = 317 mm
Punching Shear Resistance Area {2 x [(dpx . XX") + (dpy . YY")]} = 0.321 m2
Punching Shear Force Area A' = {(L x W) - (XX" x YY")} = 0.26 m2
Punching Shear Force; V'u = Q x A" V'u = 39 kN
Punching Shear Stress in Concrete τ'v = 0.122 N/mm2
Permissible Punching Shear Stress in Concrete τ'c = 1.369 N/mm2

HENCE, FOOTING IS SAFE IN TWO-WAY/PUNCHING SHEAR

7. CHECK FOR MAXIMUM SHEAR STRESS IN CONCRETE


Max. Permissible Shear Stress in Concrete τc.Max = 3.50 N/mm2
HENCE, SHEAR CAPACITY OF FOOTING IS FOUND SAFE AND IS WITHIN LIMITS
OF MAX. PERMISSIBLE SHEAR STRENGTH
8. FOOTING DESIGN SUMMARY
Footing Sizing:
Length of Footing L = 0.6 m
Width of Footing W = 0.6 m
Footing Depth @ Column Face D = 300 mm
Footing Depth @ Free End d = 300 mm

Footing Reinforcement:
Across Long Edge L 16 mm Dia @ 150 mm c/c.
Across Short Edge W 16 mm Dia @ 150 mm c/c.