Load Sensing Signal
IHA

Internationale Hydraulik Akademie GmbH


Am Promigberg 26, D- 01108 Dresden
LS Signal
150
bar 50 bar

The highest load


pressure is
switched to the
pump controller Shuttle valve

A1 A2

Min.

LS

Max.

Max. Min.
spring 15 bar +LS P

3| IHA Dresden
LS Signal

The highest load


pressure is
switched to the
A B
pump controller the pressure will rise by spool leakage

P T

0
Min.

LS
Max.

Max. Min.
spring 15 bar +LS

4| IHA Dresden
LS Signal

100
The highest load pressure is
switched to the pump
controller
A B

Standby is P T
already 115 bar

LS

Max. Min.
Spring 15 bar +LS

5| IHA Dresden
LS Signal

100
The highest load pressure
is switched to the pump
controller
A B

Standby is P T
already 115 bar

LS

Max. Min.

Spring 15 bar +LS

6| IHA Dresden
LS Signal

100
The highest load
pressure is switched to
the pump controller
A B

∆p for extension
is 15 bar

Standby is P T
already 115 bar

Min.
0
LS

Max.

Max. Min.
Feder 15 bar +LS

7| IHA Dresden
LS Signal

100
The highest load
pressure is switched to
the pump controller
A B

∆p for retraction P T
is 115 bar!
LS from wrong port!
Meter-in edge controls
the flow  speed Min.
0
LS

Max.

Max. Min.
Feder 15 bar +LS

8| IHA Dresden
LS Signal

100

LS is unloaded in center position


The LS-signal must be connected
A B to the meter-in edge!

T P T

Min.
0

LS
unloaded
0
Max.

Max.
Min.
Spring 15 bar +LS

9| IHA Dresden
LS Signal

100

The LS-signal must be connected


A B to the meter-in edge!

pilot

T P T

Min.
0

0
Max.

Max.
Min.
Spring 15 bar +LS

10 | IHA Dresden
LS Signal

100

The LS-signal must be connected


A B to the meter-in edge!

pilot

T P T

Min.
0

0
Max.

Max.
Min.
Spring 15 bar +LS

11 | IHA Dresden
LS Signal
150
bar 50 bar

A B A B

T P T T P T

LS
P

Max.

spring 15 bar +LS

12 | IHA Dresden