You are on page 1of 2

CONCRETE SLAB ON GRADE ANALYSIS AND DESIGN

For Slab Subjected to Wheel Loads and Reinforced with Steel Fibres
Designed as per TR 34 4th Edition
Job Name: WOLP Bhiwandi-Suroj Buildcon Pvt.Ltd Subject: Road Design Designer: TH
Design Date: 24/05/2020 Design Case: Axle load of 114 kN Checker: VJ

Input Data:

Slab Thickness, h = 160 mm


Concrete Strength Class = C28/35 Top of Slab

Char. Concrete Compressive Strength, fck = 28 MPa (cylinder)


Char. Concrete Compressive Strength, fcu = 35 MPa (cube)
Mean Concrete Axial Tensile Strength, fctm = 2.80 MPa
Secant Modulus of Elasticity, Ecm = kN/mm2 Contact Area, Lc × Wc h
32
Concrete Poisson's Ratio, μ = 0.15 (Sub-base)
Steel Fibre Type = Dramix® 3D
Steel Fibre Designation = 80/60 10 kg/cu.m of Dramix 3D 80/60BG
Fibre Dosage = 10.0 kg/m3
Residual flexural strength at 0.5 mm CMOD, fR1 = 1.2 MPa
h
Residual flexural strength at 2.5 mm CMOD, fR4 = 1.2 MPa
3
Sub-base Modulus, k = 0.048 N/mm
Concentrated Load, P = 57.0 kN Typical Section
Contact Length, Lc = 350 mm
Contact Width, W c = 350 mm Unbonded End
Load Spacing, (x<=2h) = 1200 mm (Plastic Sleeve)

Load Spacing, (x>2h) = 1200 mm h/2


Load Safety Factor, γL = 1.60 mm
Material Safety Factor - Concrete, γc = 1.50
6 mm thk 120 x 150
Material Safety Factor - Steel Fibre Concrete, γs = 1.20 plate dowels @ 600 c/c
Joint Spacing, L = 4.50 m Typical Construction Joint
Edge Load Transfer Ratio, ξedge = 15 %

Corner Load Transfer Ratio, ξcorner = 40 %

Calculations:

Capacity Calculations
Design Concrete Flexural Tensile Strength, fctd,fl = 2.69 MPa , = (1.6 − 0.001ℎ)/ (Eqn.1)
Ultimate Cracking Moment Capacity, Mun = 11.46 kNm/m = , (ℎ /6000) (Eqn.2)
Ultimate Moment Capacity, Steel Fibres, Mup = 4.59 kNm/m = 0.29σ + 0.16σ ℎ / (Eqn.8)
⬚⬚

Check Slab Bending: Single Point Load


Effective Load Radius, a = 197.47 mm = ⁄
Radius of Relative Stiffness, lr = 696.28 mm = ℎ /(12 1 − )
Ratio a/lr = 0.284
Ultimate Factored Internal Load, Pu,i = 91.20 kN
Internal Load Capacity, Pinternal = 222.71 kN P(allow) >= P(actual), O.K. (From Eqn. 21 and Eqn. 22)
Ultimate Factored Edge Load at Joint, Pu,e = 77.52 kN
Joint Edge Load Capacity, Pedge = 118.68 kN P(allow) >= P(actual), O.K. (From Eqn. 23 and Eqn. 24)
Ultimate Factored Corner Load at Joint, Pu,c = 54.72 kN
Joint Corner Load Capacity, Pcorner = 63.97 kN P(allow) >= P(actual), O.K. (From Eqn. 25 and Eqn. 26)

Page 1 of 2
Job Name: WOLP Bhiwandi-Suroj Buildcon Pvt.Ltd Subject: Road Design Designer: TH
Design Date: 25/05/2020 Design Case: Axle load of 114 kN Checker: VJ

Check Slab Bending: Dual Point Loads Acting Separately


Effective Load Radius, a = 197.47 mm = ⁄
Radius of Relative Stiffness, lr = 696.28 mm = ℎ /(12 1 − )
Ratio a/lr = 0.284
Ultimate Factored Internal Load, Pu,i = 91.20 kN
Internal Load Capacity, Pinternal = 272.50 kN P(allow) >= P(actual), O.K. (From Eqn. 27 and Eqn. 28)
Ultimate Factored Edge Load at Joint, Pu,e = 77.52 kN
Joint Edge Load Capacity, Pedge = 145.22 kN P(allow) >= P(actual), O.K. (From Eqn. 27 and Eqn. 28)

Check Slab Bending: Dual Point Load Clubbed Together


Effective Load Radius, a = 415.552 mm = 2 + ( − )⁄
Radius of Relative Stiffness, lr = 696.28 mm = ℎ /(12 1 − )
Ratio a/lr = 0.597
Ultimate Factored Internal Load, Pu,i = 182.40 kN
Internal Load Capacity, Pinternal = 251.74 kN P(allow) >= P(actual), O.K. (From Eqn. 21 and Eqn. 22)
Ultimate Factored Edge Load at Joint, Pu,e = 155.04 kN
Joint Edge Load Capacity, Pedge = 159.84 kN P(allow) >= P(actual), O.K. (From Eqn. 23 and Eqn. 24)

Check Slab Punching Shear: Single Point Load


Internal Load Perimeter, u1i = 3033.6 mm
vRd,c = 0.52 MPa Eqn. 13
Ground Reaction Force (Internal Load), Rpi = 4.45 kN Eqn. 31
Design Punching Load (Internal), Ppui = 86.75 kN
Punching Load Capacity (Internal), Ppmax = 206.58 KN P(allow) >= P(actual), O.K. Eqn. 13

Edge Load Perimeter, u1e = 1866.8 mm


vRd,c = 0.52 MPa Eqn. 13
Ground Reaction Force (Edge Load), Rpe = 6.49 kN Eqn. 32
Design Punching Load (Edge), Ppue = 71.03 kN
Punching Load Capacity (Edge), Ppmax = 127.13 kN P(allow) >= P(actual), O.K. Eqn. 13

Corner Load Perimeter, u1c = 1108.4 mm


vRd,c = 0.52 MPa Eqn. 13
Design Punching Load (Corner), Ppuc = 54.72 kN
Punching Load Capacity (Corner), Ppmax = 75.48 kN P(allow) >= P(actual), O.K. Eqn. 13

Results:

Design Outcome = SAFE


Concrete Grade (Cube), fcu = 35 MPa
Slab Thickness, h = 160 mm
Fibre Type & Dosage = Dramix® 3D 80/60 @ a dosage of 10 kg/cu.m
Modulus of Sub-base to be considered, k = 0.048 N/mm3
Maximum Panel Size, L = 4.5 m

Page 2 of 2