Section 7
Table 7.10: Design axial resistances of welded joints between square or circular
hollow section
2
k n f y0t0 § 2E ·
N1,Rd = ¨¨ 4 1 E ¸¸ / J M 5
1 E sin T1 © sin T 1 ¹
8,9J 0,5 k n f y 0 t 02 § b1 b2 ·
Ni,Rd = ¨¨ ¸¸ / J M 5
sin T i © 2b0 ¹
§ Oov
Member i or member j may be either tension or
compression but one should be tension and the
Ni,Rd = f yi t i ¨ beff be ,ov 2hi 4t i ·¸ / J M 5
© 50 ¹
other compression.
Brace failure 50% Ȝov < 80%
> @
Ni,Rd = f yi t i beff be ,ov 2hi 4t i / J M 5
> @
Ni,Rd = f yi t i bi be ,ov 2hi 4t i / J M 5
*) Only the overlapping brace member i need be checked. The brace member efficiency (i.e. the design
resistance of the joint divided by the design plastic resistance of the brace member) of the
overlapped brace member j should be taken as equal to that of the overlapping brace member.