1. Which of the following represents qualitative data?
a. Number related to the actual test value b. Five point five mmol/L c. Negative for COVID-19 d. None of the Above e. All of the Above 2. SI units was nationally adopted in 1960. a. True b. False 3. SI units: Name designated for Force. a. Katal b. Newton c. Hertz d. Candela e. Ampere 4. Which of the following symbols is classified as selected accepted non-SI? a. s b. m c. A - ampere d. cd e. Å - andstrom 5. SI unit used to define the amount of substance a. mol b. cd c. kat d. N e. Hz 6. What is the factor that represents prefix “peta”? a. 10-18 b. 10-15 c. 10-12 d. 1012 e. 1015 7. SI designation for temperature. a. Degree Celsius –selected derived b. Kelvin c. Fahrenheit – non-SI d. Katal e. Ampere 8. Glass that are strengthened chemically rather thermally a. Aluminosilicate glass b. Borosilicate glass c. Low-actinic glass d. Low-borosilicate glass e. Low-aluminosilicate glass 9. Low alkali content, and is free from magnesium-lime-zinc group of elements, heavy metals, arsenic and antimony. a. Aluminosilicate glass b. Borosilicate glass c. Low-actinic glass d. Low-borosilicate glass e. Low-aluminosilicate glass 10. Glassware recommended for testing or storage of bilirubin-rich sample. (hence, protects sensitive substace) a. Aluminosilicate glass b. Borosilicate glass c. Low-actinic glass d. Low-borosilicate glass e. Low-aluminosilicate glass 11. Widely used for stirring bars, tubing, cryogenic vial and bottle cap liners. a. Polypropylene b. Polyethylene c. Polycarbonate d. Polysterene e. Teflon 12. Used as Pipet tips. a. Polypropylene b. Polyethylene c. Polycarbonate d. Polysterene e. Teflon 13. The following are best examples of Transfer Pipet except a. Mohr b. Volumetric c. Ostwald-Folin d. Pasteur pipets e. None of the above 14. Centrifuge machine should be disinfected every ____. a. Shift b. Week c. 3 months – for calibration d. 6 months e. Annually 15. Relative centrifugal force must be calibrated with (RCF is computed with RPM. RPM is the one calibrated with tachometer. Not RCF) a. Tachometer b. Thermometer c. Amperometer d. All of the above e. None of the above 16. The centrifuge tubes are held in a vertical position when not moving but are horizontal when the centrifuge is fully in motion. a. Swinging Bucket Centrifuge b. Fixed Head Centrifuge c. Ultracentrifuge d. Dialysis e. OMG, nag chat chat rako ani sa akong quaranflings. 17. Generate low speeds only but can produce a tight pellet of precipitate or clotted cells in the bottom of the tube. a. Swinging Bucket Centrifuge b. Fixed Head Centrifuge c. Ultracentrifuge d. Dialysis e. OMG, nag twitter ko ani na time. 18. The sediment packs at an angle but not as tightly as with a horizontal head centrifuge. a. Swinging Bucket Centrifuge b. Fixed Head Centrifuge c. Ultracentrifuge d. Dialysis e. OMG, nag tiktok ko ani na time. 19. Generates the highest speed; in order to reduce the heat produced by the friction generated by high centrifugal speed. a. Swinging Bucket Centrifuge b. Fixed Head Centrifuge c. Ultracentrifuge d. Dialysis e. OMG, nag instagram ko ani na time. 20. Employs a proportioning system that mixes an acid concentrate with a bicarbonate concentrate and purified water to selectively filter a substance. a. Swinging Bucket Centrifuge b. Fixed Head Centrifuge c. Ultracentrifuge d. Dialysis e. OMG, nag FB ko ani na time. 21. Ability of a method to detect and measure even the smallest amount of the particular substance tested for. a. Sensitivity b. Specificity c. Precision d. Accuracy e. OMG, nag snacks ko ani na time. 22. Ability of a method to measure only the component desired without the interference of some other substances present in the same sample. a. Sensitivity b. Specificity c. Precision d. Accuracy e. OMG, nag mute og off cam ko ani na time para mag tan-aw TV. 23. The ability of the method to determine the exact value of the substance of interest in the sample a. Sensitivity b. Specificity c. Precision d. Accuracy e. OMG, nag mute og off cam ko ani na time kay gisugo ko mupalit og coke. 24. The ability of the method to give repeated results on the same sample that agrees with one another. a. Sensitivity b. Specificity c. Precision d. Accuracy e. OMG, nag mute og off cam ko ani na time kay gipapalit kog pan. 25. This is used to verify the acceptability of new methods prior to reporting patient result. a. Reliability b. Delta Checking – the act of comparing previous results with the current results. c. Method Evaluation d. Quality Control e. Quality Assurance 26. This is defined as the overall program that ensures that the final results reported by the laboratory are correct. a. Reliability b. Delta Checking c. Method Evaluation d. Quality Control e. Quality Assurance 27. This is to evaluate the quality; estimate if it meets customer’s expectations. a. Reliability b. Delta Checking c. Method Evaluation d. Quality Control e. Quality Assurance 28. Important in daily monitoring of accuracy and precision of analytical methods a. Internal QC b. Internal QA c. External QC d. External QA e. Delta Checking 29. Important in maintaining long-term accuracy of the analytical methods a. Internal QC b. Internal QA c. External QC d. External QA e. Delta Checking 30. The following are characteristics of an ideal WC material except a. Inexpensive and stable for long periods b. No communicable diseases c. With matrix effect d. With convenient packaging e. With known analyte concentrations 31. A type of error that is present in all measurements; due to chance (unpredictable) a. Random Error b. Ransom Error c. Systematic Error d. Systemic Error e. No sir, he doesn’t deserve my 15th chance. Di na ako marupok. 32. A type of error that is due to improper mixing of samples. a. Random Error b. Ransom Error c. Systematic Error d. Systemic Error e. Margin of Error 33. A type of error that is seen always in one direction. a. Random Error b. Ransom Error c. Systematic Error d. Systemic Error e. Zayn Malik 34. The following are necessary for LJ chart except a. Mean b. Standard Deviation c. Coeffecient of Variation d. Mode e. None of the above 35. All of the following are used histogram in QC except a. Levey-Jennings Chart b. Shewhart Chart c. Dot Chart d. All of the above e. None of the above 36. Error that is formed by the control that continue either increase or decrease for a period of 6 or more consecutive days a. Trend b. Shift c. Outlier d. Huhu, wala jud ko ka gets sir pero wala ko nag-ask kay naulaw ko huhu 37. Error that is formed by the control that distribute themselves on one side (above or below) of the mean, with no tendency toward either a consistent fall or rise a. Trend b. Shift c. Outlier d. Huhu, wala jud ko ka gets sir . maypag nag-ask nalang jud ko. huhu 38. Considered as warning rule. a. 1 2s b. 1 3s c. 2 2s d. R 4s e. 4 1s 39. It is violated when the IQC value exceeds the mean by 3SD. The assay run is regarded as out of control. a. 1 2s b. 1 3s c. 2 2s d. R 4s e. 4 1s 40. It is violated if four consecutive IQC values exceed the same limit (mean 1SD) and this may indicate the need to perform instrument maintenance or reagent calibration. a. 1 2s b. 1 3s c. 2 2s d. R 4s e. 4 1s