Professional Documents
Culture Documents
FORMpac’s
Rubber
Element
catEXX™ System
One Trip Expansion
FORMlock
EXPress
Blank
catEXX System Pipe FORMpac EXPress
Screen
Carry in Dogs
Run In Well
Dogs Release
FORMlock EXPRESS Hanger 7" 23# Yes Yes 5 In conjunction with expandable EXPRESS Screen size 4-3/4" f/ 6" & 6-1/8" Open Hole
7" 29# As needed** No YES** PDO are running very few heavy weight liners, Exploration or Deep Completion
7" 32# As Needed** No YES** PDO are running very few heavy weight liners, Exploration or Deep Completion
9-5/8" 40# Yes Yes 7 In conjunction with expandable EXPRESS Screen size 6-7/8" f/ 8-1/2" Open Hole
9-5/8" 47# As Needed** No YES** Non immediate application based upon local knowledge
9-5/8" 53.5# As Needed** No YES** Non immediate application based upon local knowledge
FORMpacXL Packers 6" Open Hole Yes Yes Zonal Isolation and or Water Shut Off (I.e. Northern fields [Al Huwaisah/Yibal/Fahud/Lekhwair] )
6-1/8" Open Hole No Yes Development pending - available Q3 2002
8-1/2" Open Hole Yes Yes Zonal Isolation and or Water Shut Off (I.e. Northern fields [Al Huwaisah/Yibal/Fahud/Lekhwair] )
EXPress Screen 4-3/4" f/ 6" Open Hole ~150 micron Yes Yes Can be used in 6-1/8" Open Hole but in conjunction with FORMpacXL to prevent annulus flow
4-3/4" f/ 6" Open Hole ~250 micron Yes Yes Can be used in 6-1/8" Open Hole but in conjunction with FORMpacXL to prevent annulus flow
4-3/4" f/ 6-1/8" Open Hole ~150 micron Yes* Yes* 5* Screen not yet manufactured, development completed. Screen delivered After Order Received (AOR)
4-3/4" f/ 6-1/8" Open Hole ~250 micron Yes* Yes* Screen not yet manufactured, development completed. Screen delivered After Order Received (AOR)
6-7/8" f/ 8-1/2" Open Hole ~150 micron Yes Yes 5** This size has been manufactured since Q1 2002, delivery upon AOR
6-7/8" f/ 8-1/2" Open Hole ~250 micron Yes Yes This size has been manufactured since Q1 2002, delivery upon AOR
The actual um rating may vary slightly from the numbers above.We will recommend a rating based on formation sand data,either "fine" or "coarse"
EXPress Blank 4-3/4" for Cladding inside 7" liner Yes Yes 5 In conjunction with EXPress Screens and Solid Expansion or Cladding in Cased and Open Hole
6-7/8" for Cladding inside 9-5/8" csg Yes Yes 5 In conjunction with EXPress Screens and Solid Expansion or Cladding in Cased and Open Hole
Actual clad size may be different.**
Solids / Cladding Cladding/Solids 7" 23# Liner Yes Yes 2 Water shut-off / casing repair in cased hole application by using EXPress Blank and FORMpac
Cladding/Soilds 9-5/8" 40# Casing Yes Yes 2 Water shut-off / casing repair in cased hole application by using EXPress Blank and FORMpac
Cladding/Patch 6-1/8" Open Hole Yes Q2-2003 5 Water shut-off in open hole application by using EXPress Blank and FORMpacXL
Cladding/Patch 8-1/2" Open Hole Yes Q2-2003 5 Water shut-off in open hole application by using EXPress Blank and FORMpacXL
PDO.Oman